AppNote 5/2006 ABSTRACT

Similar documents
Rapid Determination of Drug Protein Binding Affinity using Solid Phase Microextraction

Online LC Sample Preparation with BioTrap 500 C18

Investigation of Solid Phase Microextraction as an Alternative to Dried Blood Spot

Quantitatitive Analysis of Phosphorothioate Oligonucleotide in Human Plasma Using LC-MS/MS with On-Line Extraction

EVOLUTE ABN FOR EXTRACTION OF DRUGS FROM BIOLOGICAL FLUIDS

NISTmAb characterization with a high-performance RP chromatography column

Solutions Guide. MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications

Mimetic Blue Affinity Adsorbents Mimetic Blue 1 P6XL, Mimetic Blue SA P6XL Mimetic Blue SA HL P6XL, Mimetic Blue ELISA Kit

SPE in Disk Format. Experimental. Table 1 Comparison of Typical SPE Cartridge and Empore Disk

Rapid Extraction of Therapeutic Oligonucleotides from Primary Tissues for LC/ MS Analysis Using Clarity OTX, an Oligonucleotide Extraction Cartridge

Hichrom Limited 1 The Markham Centre, Station Road, Theale, Reading, Berkshire, RG7 4PE, UK Tel: +44 (0) Fax: +44 (0)

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Additional guidance on: TNsG on Data Requirements, Part A, Chapter 2, Point 4. Analytical Methods for Detection and Identification.

3 Empore. High Performance Extraction Disk Cartridges October Answers to Frequently Asked Questions. Product Description

Agilent Sample Preparation Portfolio ACCURATE, REPRODUCIBLE RESULTS RIGHT FROM THE START

High-throughput solid-phase microextraction in multi-well plate format

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Experimental. Instrumentation

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

The system has an optimized porosity distribution and acts as a depth filter, retaining the precipitated protein without well blockage.

ITSP Extraction of Cortisol from Plasma

Simplifying ImmunoAffinity Capture Workflow

BioTrap 500 C18/C8 INSTRUCTION MANUAL. for direct injection of up to 500 µl plasma in HPLC. Illustration of a BioTrap 500 particle

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

Universal Solution for Monoclonal Antibody Quantification in Biological Fluids Using Trap-Elute MicroLC-MS Method

A Generic Approach to the Extraction of Multi-functional Drugs using Mixed-mode SPE with LC-MS/MS Analysis

Ultra-Sensitive Quantification of Trastuzumab Emtansine in Mouse Plasma using Trap-Elute MicroLC MS Method

High Speed, Ultra-High Sensitivity, and Robustness Needed for the Quantitation of Pharmaceuticals in Blood Plasma. Application Note. Authors.

High-Throughput, Simplified Protein Precipitation: A Novel 96-Well Format for Precipitation and Filtration EAS 2003

PAL SPME Fibers Optimized for Automation

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

PAL SPME Fibers Optimized for Automation

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

RAM Direct Injection. (Restricted Access Media) A Tool for the Separation of Small Molecules in the Presence of Large Biomolecules

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

SIMPLE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR DETERMINATION OF NORFLOXACIN IN PLASMA AND APPLICATION IN BIOEQUIVALENCE STUDY

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2

Developing Quantitative UPLC Assays with UV

Impurity Control in the European Pharmacopoeia

Validation of a concentration assay using Biacore C

GUIDANCE NOTES ON ANALYTICAL METHOD VALIDATION

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

quantification of an oligonucleotide

Microflow Liquid Chromatography Mass Spectrometry System. Nexera Mikros C146-E350

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Fusion Analytical Method Validation

The Benefits of SOLAμ Technology in Sample Preparation. Jon Bardsley and Ken Meadows Thermo Fisher Scientific, Runcorn, UK

for water and beverage analysis

TSK-GEL BioAssist Series Ion Exchange Columns

HARMONIZATION TEAM A6 (STABILITY) UPDATE. Yoshiaki Ohtsu 8 March 2012

Understanding the Effects of Common Mobile Phase Additives on the Performance of Size Exclusion Chromatography

Journal of Pharmaceutical and Bioanalytical Science

DETERMINATION OF ORGANIC PRIORITY POLLUTANTS AND EMERGING COMPOUNDS IN WASTEWATER BY MICRO SOLID PHASE EXTRACTION COUPLED TO GCMS

PPS (Human) ELISA Kit

Application Note. Authors. Abstract. Biopharmaceuticals

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

(Refer Slide Time: 00:16)

EAG.COM MATERIALS SCIENCES APPLICATION NOTE. By J. Tompkins 1, T. Spurgeon 1, R. Tobias 1, J. Anders 1, E. Butler-Roberts 2, and M.

BIOANALYSIS CONSUMABLE SOLUTIONS. Sample Preparation and Liquid Chromatography Solutions for Quantitative BIOANALYSIS

Sample Prep - Solid Phase Extraction

Bioanalytical Concentrations Below the LLOQ:

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

TECHNICAL INFORMATION

RAM DIRECT INJECTION (RESTRICTED ACCESS MEDIA)

Research Paper Development of Stability Indicating Reverse Phase HPLC Method for Aripiprazole from Solid Dosage form

Validation of a Dual Wavelength Size Exclusion HPLC Method with Improved Sensitivity to Detect Aggregates of a Monoclonal Antibody Biotherapeutic

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

ISSN India; g,secunderabad. Abstractt. a flow rate. of 1ml/min. di hydrogen. which acts. and chronic. including minimize (5) Figure

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE.

A fast and simple workflow for surrogate peptide bioanalysis: NISTmAb case study

Fusion Analytical Method Validation

SYMBIOSIS LAB EFFICIENCY OF UNLIMITED DIMENSIONS

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

Analysis of styrene leached from polystyrene cups using GCMS coupled with Headspace (HS) sampler

Validation of Analytical Method of Irbesartan Plasma in Vitro by High Performance Liquid Chromatography-Fluorescence

Chapter 2 deals with LC-ESI-MS/MS studies on forced degradation of abacavir sulphate an anti HIV drug.

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

Automation for Improving the Workflows for LC-MS/MS. Francois Espourteille, Ph.D. Manager, Applications

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Analysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System

Analysis of wear metals and contaminants in engine oils using the 4100 MP-AES

ultra why micro-lc? product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc

B r i n g i n g e x p e r t s t o g e t h e r TELOS neo Polymeric Solid Phase Extraction Columns Simple and Effective SPE

ENVIRONMENTAL CHEMICAL ANALYSIS III

Optimizing Purified Sample Recovery on Reverse-Phase HPLC Systems

Ion Exchange Chromatography. Learning Objectives:

Agilent 6430 Triple Quadrupole LC/MS System

Transcription:

AppNote 5/26 Stir Bar Sorptive Extraction Based on Restricted Access Material for the Direct Extraction of Drugs and Metabolites in Biological Fluids Wayne M. Mullett and Elizabeth Kwong Merck Frosst, Pharmaceutical Research and Development, 16711 Trans Canada Highway, Kirkland, Quebec, Canada, H9H 3L1 ABSTRACT An experimental biocompatible stir bar sorptive extraction (SBSE) device was prepared using a restricted access material (RAM) as the SBSE coating. The biocompatible SBSE approach was advantageous in terms of simplifying the sample preparation procedure. The RAM-SBSE bar was able to simultaneously fractionate the protein component from a biological sample, while directly extracting caffeine and its metabolites; overcoming the present disadvantages of direct sampling in biological matrices by SBSE, such as fouling of the extraction coating by proteins. Analytical Figures of Merit for Caffeine Determination in Plasma: - Limit of detection (s/n = 3) for caffeine = 25 ng/ml - Linear over the range of.5-1 μg/ml (R 2 =.9981) - Injection repeatability and intra-assay precision % R.S.D. < 8% The RAM-SBSE device was simple to use, robust and reuseable with over 5 direct extractions of caffeine and its metabolites in biological fluids without significant signal loss.

INTRODUCTION Stir bar sorptive extraction (SBSE) is a novel extraction technique that utilizes glass stir bars coated with polydimethylsiloxane (PDMS) for extraction of organic compounds, such as environmental contaminates, in aqueous samples. The device operates similar to a conventional magnetic stirring rod, with the PDMS coating enabling direct sample clean-up and analyte preconcentration while stirring. The higher extraction phase ratio of SBSE also provides better recovery and sample capacity over microextraction approaches such as solid phase microextraction (SPME). Although SBSE has been used for biological sample analysis, limitations with the available PDMS coating exist and include lack of selectivity for more polar compounds and potential fouling of the coating from protein adsorption during extraction in biofluids. This leads to poor reproducibility and recovery of analytes from biological fluids. The applicability of the SBSE approach to bio logical fluid analysis was extended via a bio compatible absorbent coating of particles, known as restricted access materials (RAM). The RAM coating was able to fractionate a sample into the protein matrix and the analytes, while simultaneously extracting low molecular weight compounds into the phase s interior (see Figure 1). Various extraction phases, such as C 4, C 8, C 18 and ion exchange are available to provide a wide range of selectivity. The novel RAM SBSE device could be directly stirred in biological fluids for analyte extraction without fouling of the coating from proteins and therefore minimizing sample preparation and extraction solvents requirements. Its ability to directly extract a model compound (caffeine) and various metabolites from plasma, followed by liquid desorption and HPLC-UV analysis was studied. EXPERIMENTAL RAM coated stir bars (17 mm x 2 mm o.d.) were prepared with various coating procedures using a 2 part epoxy as a binding agent for the RAM particles. Extraction: - An extraction time profile was obtained by stirring the RAM SBSE bar at 1 RPM in spiked rat plasma samples for various periods of time and measuring the levels of caffeine extracted. - After the extraction is completed, the bar is removed with a steel rod and placed in the desorption vial. Desorption: - A desorption time profile was obtained by stirring the RAM SBSE bar at 1 RPM in 75:25 (v/v) H 2 :ACN. - After desorption was complete, the stir bar is removed and the sample is injected for HPLC-UV analysis. Figure 1. Schematic representation of a restricted access material (RAM). AN/26/5-2

RESULTS AND DISCUSSION The coating immobilization procedure is critical since it must withstand the frictional forces associated with high stirring rates during SBSE, providing multiple extractions (> 5) in complex sample matrices. A fairly uniform coating of the RAM particles on the SBSE device was observed in contrast to the initial smooth surface topography of the glass stir bar support (Figure 2). A B Figure 2. Scanning electron micrographs of glass stir bar (A) and RAM-SBSE bar coating (B). An extraction time profile was prepared by stirring the RAM-SBSE device in caffeine solutions over a period of time, followed by desorption and analysis (Figure 3). 25 2 15 1 5 5 1 15 Extraction Time (min) Figure 3. RAM-SBSE extraction time profile of caffeine spiked in rat plasma. Approximately one hour of extraction was required for the RAM-SBSE bar to reach equilibrium. Since equilibrium is not required for analysis, the developed method utilized an extraction time of 3 minutes to limit the overall analysis time. Desorption of the extracted analytes was accom plished by stirring the RAM SBSE device in an appropriate solvent. The composition of the desorption solvent was investigated to ensure complete removal of the analytes from the C 18 extraction coating of the stir bar. A desorption time profile was recorded to determine the time required to ensure quantitative removal of the extracted analytes (Figure 4). 38 36 34 32 3 28 26 24 22 2 1 2 3 4 5 Desorption Time (min) Figure 4. RAM-SBSE desorption time profile of caffeine spiked in rat plasma. Sample carry-over was evaluated by completing successive desorption steps in fresh solvent; with no detectable amount of caffeine observed in subsequent desorptions. AN/26/5-3

The robustness of the stir bar was illustrated with over 5 extractions with minimal loss of extraction efficiency (Figure 5). The RAM-SBSE device could withstand repeated and direct exposure to plasma, while providing a consistent HPLC peak area for caffeine extraction. 25 23 21 19 17 15 Extraction #1-2 Extraction #55-56 Figure 5. HPLC RAM-SBSE method for caffeine extraction from plasma. The effect of plasma matrix on the recovery of caffeine was evaluated by comparison to extraction of caffeine in PBS. As shown in Table 1, multiple extractions in both matrices produced similar results indicating complete recovery of caffeine from plasma with good reproducibility (R.S.D. = 8 %). Table 1. Recovery and Reproducibility of Caffeine Extraction by RAM SBSE. Sample No. HPLC Peak Area Caffeine* (PBS) Caffeine* (Plasma) 1 24 32 2 25 3 3 25 27 4 28 32 5 3 3 Average 27 3 % RSD 8. 8. *Caffeine concentration = 5 µg/ml A calibration curve was prepared for caffeine analysis in rat plasma using the RAM-SBSE approach. The curve showed very good linearity over a 2 order of magnitude concentration range. 3 25 2 15 1 5 y = 2.8223x +.3517 R 2 =.9981 2 4 6 8 1 12 [caffeine] in g/ml Figure 6. RAM-SBSE calibration curve for caffeine spiked rat plasma. Blank extractions from plasma were performed to rule out the presence of interferring compounds from the biological matrix extracted by the RAM-SBSE bar that could co-elute with caffeine. An absence of chromatographic peaks at the analyte s retention time confirmed the selectivity of the method. The results from the RAM-SBSE extraction were compared to results obtained from a standard protein precipitation method. The RAM SBSE provided a much cleaner extract than protein precipitate plasma as can be clearly seen when comparing the resulting chromatograms (Figure 7A and figure 7B). This effect was very pronounced early in the chromatogram, which is significant since many metabolites (polar compounds) will elute early on commonly used C 18 analytical columns. The plasma spiked with metabolites was successfully extracted using the RAM SBSE device. Caffeine recovery in Plasma compared to phosphate buffer saline (PBS) = 11%. AN/26/5-4

Figure 7. HPLC sample chromatograph of caffeine, 1,7-dimethylxanthine (1,7-DX), 1-methylxanthine (1-MU) and 1-methyluric acid (1-MX) in plasma (a) RAM-SBSE extraction and (b) protein precipitated plasma sample. CONCLUSIONS An experimental RAM-SBSE bar was developed for direct extraction and desorption of caffeine and metabolites from biological samples. The binding capacity, ex traction efficiency and reproducibility of extraction were suitable for UV determination over a wide range of caffeine concentrations in plasma. The bar was reusable (> 5 times), providing cleaner extracts than existing sample prep methods and simplified sample handling. Selectivity towards many classes of drugs is possible using with C 4, C 8, C 18 or ion exchange extraction phases located inside the pores of the coating. The simplicity and compatibility of SBSE with many analytical systems such as HPLC and GC extends the versatility of the RAM-SBSE device for bioanalysis. To enable a more automated procedure, extractions by RAM-SBSE bar coupled to thermal desorption GC/MS are considered for future work. ACKNOWLEDGEMENTS Jean-Philippe Lambert (University of Ottawa, Ottawa, Ontario, Canada) Rafik Naccache (Merck Frosst, Kirkland, Quebec, Canada) Eike Kleine-Benne and Andreas Hoffmann (GERSTEL, Mülheim an der Ruhr, Germany) AN/26/5-5