WoodTrends Acoustical Wood Ceiling System BASIC Specification

Similar documents
Ceiling Tiles C200B - Specification

RULON ACOUSTICAL CEILING SYSTEM ALURATONE 100 ARCHITECTURAL SPECIFICATIONS

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

Submittal Transmittal

Section Wood Veneer Ceiling Tiles Micro Perforated

WOODFIT ACOUSTICS PERFORATED CEILING SYSTEM P007 ARCHICTECTURAL SPECIFICATION

Section SoundPly RF M25 Acoustic Wall Panels

Section Wood Grille Ceiling Panels

ACOUSTICAL WALL TREATMENT SECTION 09840

Section Wood Veneer Ceiling Planks Linear

Geometrik Manufacturing Inc.

Section SoundPly LR M25 Acoustic Ceiling Panels

DiSorb Diffuser Product Specifications Section Sound Diffuser-Absorber for Ceilings and Walls (DiSorb Diffuser-Absorber)

SECTION SOUND-ABSORPTIVE PANELS

RULON LINEAR OPEN SUSPENDED WOOD CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

SECTION (09800) - Suspended Acoustic Baffles. This Section is based on TECHLITE Accent Linear Ceiling Baffles.

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

SECTION SOUND-ABSORPTIVE PANELS

Wood Veneered Acoustic Panels Standard & Trend Technical Specifications

Geometrik Manufacturing Inc.

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

STANDARD & TREND WOOD VENEERED ACOUSTIC PANELS

EXTERIOR PLANK SERIES SPECIFICATION DATA

SECTION ACOUSTICAL PLASTER CEILINGS

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

SECTION ACOUSTICAL PLASTER CEILINGS

Florock Seamless Flooring Systems

SECTION ACOUSTICAL CEILINGS

SECTION / / BULLET RESISTANT SOUND CONTROL WINDOWS

STANDARD & TREND WOOD VENEERED ACOUSTIC PANELS

SECTION SONEX Acoustical Wall Treatment

SECTION / STC 52 METAL SOUND CONTROL DOORS

Florock Seamless Flooring Systems

Panelized Linear Walls Installation Guide

Florock Seamless Flooring Systems

Guide Specifications Section Wood Ceiling Coffers

GUIDE SPECIFICATION: DUCT LINER

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

SECTION ACOUSTICAL PLASTER CEILINGS

Florock Seamless Flooring Systems

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

Florock Seamless Flooring Systems

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS

HIR 1 ACOUSTICAL, IMPACT RESISTANT, TACKABLE WALL PANEL SPECIFICATION

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

SECTION COMPOSITE CORE ACOUSTICAL PANEL CEILINGS. Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3

SECTION INTUMESCENT MASTIC FIREPROOFING

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

Note: Delete any section below not relevant to this project; add others as required.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

BASIC, SYSTEM & SELECT WOOD VENEERED ACOUSTIC PANELS

Guideline Specifications GORDON MARQUIS LINEAR CEILING PANEL SYSTEMS

THIS SECTION IS BASED ON ROCKFON S SPANAIR HOOKON METAL CEILING PLANKS.

Curvalon and Curvatone Ceilings Installation Guide

SECTION GLASS FIBER REINFORCED GYPSUM FABRICATIONS

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

SECTION SOUND CONTROL DOORS

FYPON, LLC. February 2014

Florock Seamless Flooring Systems

Union County Vocational - Technical Schools Scotch Plains, New Jersey

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

Technical Data VARIABLES

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE D LAY-IN METAL CEILING PANELS.

Showcase Your Space. Not Your Access Panel. Product Features. Shop online at or call

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Series 3000 Pocket Doors

Florock Seamless Flooring Systems

SECTION ACCORDION FOLDING PARTITIONS

KOSTER AMERICAN CORPORATION

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

ACOUSTICAL WALL TREATMENT 09840

Product Guide Specification

HPL CSI 3-PART SPECIFICATION FORM

UPHOLSTERED WALL SYSTEM UPHOLSTERED WALL SYSTEM

Guide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [ ] or Section [ ]

PRODUCT SPECIFICATIONS

Florock Seamless Flooring Systems

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

INFINITY MAX TILE SPECIFICATION

Technical Data VARIABLES

5. Division 9 Section "Site-Built Stretched Fabric Wall System" for site-built stretched fabric

Acrylitex Tilt UP Primer Guide Specification Revised August 1, 2008

Architectural Components Group, Inc.

ENKASONIC FLOOR UNDERLAYMENT 9110

FINA Stoneworks NATURAL STONE HONEYCOMB REINFORCED PANEL SYSTEM

SECTION Silane Water Repellents. Vexcon

SECTION DETECTABLE GUIDE TACTILES

Product Guide Specification

Transcription:

WoodTrends Acoustical Wood Ceiling System BASIC Specification SECTION 09570 WOOD CEILING / WALLS PART 1 GENERAL 1.00 GENERAL 1.01 SCOPE A. WoodTrends Acoustical Wood Systems covered by this specification shall be the products of Acoustical Solutions, 2420 Grenoble Road, Richmond, VA 23294; Phone (800) 782-5742 (804) 346-8350; Fax (804) 346-8808 Website: https://acousticalsolutions.com A. Sound Seal shall furnish all WoodTrends acoustical wood panel assemblies necessary to complete installation by contractor in accordance with plans and specification. 1.02 RELATED WORK BY OTHERS A. Substrate walls systems and structure and miscellaneous attachment devices other than those specified herein, are not included. 1.03 QUALITY ASSURANCE A. Installer Qualification: The installer shall be a firm with a minimum of two (2) years of successful experience in installation of products with similar requirements. The installer shall be acceptable to the architect, manufacture, and owner representative. B. Fire Performance Characteristics: WoodTrends acoustical wood panels should be constructed using fire retardant components meeting or exceeding the requirements of the ASTM E-84 Class (A, B, C) 1. Flame Spread: (25 or less, 26 to 75, 76-200) 2. Smoke Developed: 450 or less C. Noise Reduction Coefficient: The WoodTrends BASIC panels will have a minimum NRC value of, with a (perforation, slot) pattern measuring, when tested in accordance with ASTM C-423. 1.04 PROJECT CONDITIONS Installation shall be done only when the temperature and humidity closely approximate the interior conditions that will exist when the building is occupied. The heating and cooling systems shall be operating before, during, and after installation, with the humidity of the interior spaces maintained between min. 45% - max. 65%. Prior to installation panels shall be allowed to stabilize on site 72 hours prior to installation, the site must be free of wet and dusty trades and the climate conditions stabilize to normal operational levels.

1.05 SUBMITTALS A. Submit shop drawings prepared by the manufacturer showing all necessary details and dimension requirements which will subsequently be field verified and revised as required by the Architect. B. Samples: Submit (3sets) 8 x 11 sample panels of each type of product and finish as specified. Product shall be original production in veneer finish specified for final use. C. Certification: Submit to the owner a certificate of compliance to specified acoustical and fire performance criteria signed by an officer of the panel manufacturer and attach independent laboratory test results for each product used, showing that the products supplied as components meet or exceed the specified requirements. D. Single Source: All custom acoustical wall and ceiling panels shall be purchased from a single manufacturer. 1.06 DELIVERY, STORAGE, AND HANDLING A. Panel assemblies shall be delivered to the project site in original, unopened packages. B. Prior to panel installation the site must be free of all wet and dusty trades and the climatic conditions stabilized to normal operational levels. C. The panels shall be stored in a fully enclosed space. For a minimum of seventytwo (72) hours immediately prior to installation, store the panels in the room in which they will be installed. The temperature and humidity of the room shall closely approximate those conditions that will exist when the building is occupied. Store the panels off the floor. D. Care in handling MUST be exercised to avoid damage. 1.07 WARRANTIES A. Manufacturer: All materials supplied by the manufacturer shall be guaranteed against manufacturing defects for one year. B. Contractor: All work shall be guaranteed for one year from final acceptance of completed work.

PART 2 PRODUCTS 2.01 WOODTRENDS ACOUSTIC PANELS A. Furnish and deliver prefabricated BASIC panels as described in this section for installation in areas as shown on drawings meeting or exceeding the following requirements: Description: WoodTrends BASIC panels, as supplied by: 2.02 PANELS Acoustical Solutions, 2420 Grenoble Road, Richmond, VA 23294 Phone (800) 782-5742 (804) 346-8350; Fax (804) 346-8808 Website: https://acousticalsolutions.com A. Substrate of fire-retardant 13 mm thick MDF with blind veneer backer B. 0.6 mm thick real wood veneer face C. Edge detail a) 5 mm deep x 8 mm wide rabbet for drop-in mounting D. Acoustics 2.03 PANEL FINISHES a) Achieved by means of (round perforation measuring ), or (elongated slot measuring ) b) Acoustic textile adhered to back of panel A. Veneers to be: B. Lacquer a) First Quality select veneer from manufacturer s standard selection of 24 real wood species. b) Additional 40 species available with special veneers staining and lacquering to match architect s samples. a) Two coats UV- polyacrylate 2.04 SUPPORT SYSTEMS

A. (24 x 24, 24 x 48 ) BASIC ceiling panels shall be installed by means of drop-in mounting on intermediate duty (9/16 or 15/16 ) T-grid. PART 3 EXECUTION 2.05 ACOUSTICAL PERFORMANCE 3.01 PREPARTION Sound Absorption: Per ASTM C 423 Sound Absorption Coefficient per Octave Band Center Frequency (Hz) 125 250 500 1000 2000 4000 NRC See Acoustic Test Data page for selections A. Layout: If required, prior to manufacture, field dimensions shall be taken to determine panels sizes. The contractor shall measure applicable areas prior to installation to confirm application and location of panels supports, in accordance with installation instructions. B. Coordination: The contractor shall coordinate with other trades the location of devices which will penetrate the panels of interfere with the installation. Recessed or surface devices located within the panels are to be located and out in the field. 3.02 INSTALLATION A. General: Install materials in accordance with manufacturer s printed instructions and approved shop drawings. The installation shall comply with applicable regulations and industry standards. B. Provide shimming and adjustments as required to maintain consistent alignment of joints and of finished panel faces. 3.03 ADJUSTMENT, CLEANING, AND REPAIR A. The contractor shall make final adjustments to level or contours. B. Upon completion of installation, all BASIC panels shall be cleaned free of dirt, dust, grease, oils, and fingerprints. Wood surfaces shall be wiped with furniture polish to enhance the surface finish. C. All work, which cannot be successfully cleaned or repaired, shall be removed and replaced. 3.04 INSPECTION

A. Upon completion of installation, the owner s representative shall inspect all finished surfaces to ensure that work has been performed in a manner satisfactory to the owner. Any deficiencies in the installed panels shall be corrected by the contractor at no additional cost to the owner, or to the manufacturer.