SPP at a Glance. Located in Little Rock. Approximately 600 employees

Similar documents
SPP101. An Introduction to Southwest Power Pool. SouthwestPowerPool SPPorg southwest-power-pool

PJM Wholesale Markets. Hisham Choueiki, Ph.D., P.E. Ohio PUC Staff October 20-24, 2014 Tbilisi, Georgia

CURRENT FEDERAL AND REGIONAL ELECTRIC POLICY ISSUES FOR THE ILLINOIS COMMERCE COMMISSION

Key Issues and Consideration in Market Design, Operational and Oversight

Regional Transmission Organizations. D. William VanderLaan Illinois Commerce Commission January 30, 2014

BEFORE THE PUBLIC SERVICE COMMISSION OF THE STATE OF MISSOURI

Competitive Markets 1

Competitive Markets. Facilitated Dialogue: Market Restructuring & Renewable Energy. June 10-12, 2013 Mexico City, Mexico. Hisham Choueiki, Ph.D., P.E.

With funding provided by the US Department of Energy, NREL, and the Utah Office of Energy Development

Draft Whitepaper to Platte River Board of Directors

Energy Markets - The Basics

Wholesale Electricity Markets. New England Independent System Operator. Commissioner Mark Vannoy Maine Public Utilities Commission

PJM Organization and Markets. Saudi Delegation Columbus Ohio May 22, 2012

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION. SOUTHWEST POWER POOL, INC.'s REPORT REGARDING FUEL ASSURANCE ISSUES

PJM Overview: PJM Structure and Cross-Border Examples PJM 2010

Growing Wind. Final Report of the NYISO 2010 Wind Generation Study. John Adams Principal Electric System Planner New York Independent System Operator

New England Power Sector Overview

AEP Transmission Local Planning Assumptions, Models, and Criteria

2016 Summer Reliability Assessment

ELECTRIC TRANSMISSION 201: Markets, ISO/RTOs and Grid Planning/Operations

Definitions O - P. Open Access Same-Time Information System (OASIS) or PJM Open Access Same-time Information System:

ISO/RTO Metrics Initiative

Designing Energy Solutions

Status Update Assessment of ICT/RTO Options and Issues

BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION

Illinois State Institute for Regulatory Policy Studies Conference

PJM Markets. Energy and Ancillary Services. PJM State & Member Training Dept. PJM /29/2014

The State of Wind Energy in New England

Recent Development in Reliable Energy Market in the US and Singapore

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

Eligible Intermittent Resource Dispatch Operating Target EIR DOT

MIDWEST ISO UPDATE. Sherman Elliott Manager State Regulatory Affairs

Wind Power Forecasting Process Development

ELECTRIC TRANSMISSION 101: Regulation. Jeff Dennis Office of Energy Policy and Innovation Federal Energy Regulatory Commission

Introduction to the Energy Imbalance Market (EIM Module 1)

Transmission & Ancillary Services Formula Rates. Public Information Forums November 19, Omaha, NE November 20, Fargo, ND

June 21, Southwest Power Pool, Inc., Docket No. ER Order No. 755 Compliance Filing

Glossary of Terms Used in Reliability Standards. Preliminary Draft Version 0 Reliability Standards September 1, 2004

CALIFORNIA INDEPENDENT SYSTEM OPERATOR CORPORATION FERC ELECTRIC TARIFF Sheet No. 691 ORIGINAL VOLUME NO. III

Making Sense of U.S. Energy Markets

Standards Authorization Request Form

The Evolution of the PJM Market in the United States: Looking Back to Look Forward

Fred Stoffel. Tri-State Generation and Transmission Association, Inc. May 19, Utility Resource Planning Fundamentals

FirstEnergy Solutions Energy Market Update AEE Meeting March 20, John Ogurchak PE/CEM Manager, Commercial/Industrial Energy Sales

Managing Director Transmission Operations

Mountain West Transmission Group Frequently Asked Questions Updated through September of 2017

October 18, Southwest Power Pool, Inc., Docket No. ER Submission of Tariff Revisions

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

The Role of the ISO/RTO in Today s. Robert B. Burke Principal Analyst ISO New England Inc.

ERCOT ISO: Current Market and Trends in Future Market Design

Seminar on African Electrical Interconnection. Module 7 - Market Operational Structures

Distributed Energy Resources Roadmap

The Year to Date in PJM: Operations and Markets

Business Practice Manual for the Transmission Planning Process

LOAD SERVING ENTITIES PJM REGION

TARIFF FOR WHOLESALE TRANSMISSION SERVICE SHARYLAND UTILITIES, L.P. SHARYLAND UTILITIES, L.P North Akard Dallas, Texas 75201

Transmission ITP. Introduction. PJM State & Member Training Dept. PJM /10/2018

NERC Reliability Functional Model

Demand-Side Resources and Electricity Markets

PJM Wind Integration Initiatives

SPP and the EPA Clean Power Plan. Carl A. Monroe Exec VP & COO

RTOs, ISOs and Wholesale Electricity Markets

Federal Energy Regulatory Commission/RTO Training Session

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION

STANDARD CONTRACT RIDERS - (Continued) RIDER NO. 9 DAY-AHEAD HOURLY PRICE SERVICE

Winter Reliability Assessment

MOD-001-1a Available Transfer Capability Implementation Document

Journey in supporting important energy and environmental policies while maintaining reliability through a resilient power grid system

Midwest ISO EIM Start-up and Exiting Issues Todd Ramey, Executive Director Market Administration. March 7-8, 2011

NORTHERN MAINE INDEPENDENT SYSTEM ADMINISTRATOR, INC.

Mid-Continent Independent System Operator (MISO) Overview. INCMA February 15, 2017

NORTHERN MAINE INDEPENDENT SYSTEM ADMINISTRATOR, INC.

5.1 Transmission Congestion Charge Calculation Calculation by Office of the Interconnection.

2016 Probabilistic Assessment. December 5, 2016 Southwest Power Pool

Introduction to the PJM Markets

S P P T P L S t e a d y S t a t e A s s e s s m e n t

Glebe to Potomac River Proposed 230kV Line & Substation Project Dominion

Transmission Planning at the Midwest ISO. Mr. Eric Laverty Senior Manager of Transmission Access Planning Midwest ISO June 26 th, 2008

Business Practice Manual for Reliability Requirements. Version 34

Gregory McAuley Direct Testimony

Journey in supporting important energy and environmental policies while maintaining reliability through a resilient power grid system

Market Liberalization - Electricity Market Competition (wholesale) Mark Vannoy, Chairman. Maine Public Utilities Commission

Participation in the monthly auction and the capability period auction shall consist of:

Imperial Irrigation District Manager Energy Department

From Restructuring to Decarbonization: Operational and Market-Design Challenges in New England

Overview. IEEE Boston Chapter ISO New England Inc.

Overview of PJM: Looking Back to Look Forward Tokyo Power Market Summit

PJM briefing. Greater Philadelphia Chapter of the Association of Energy Engineers. PJM Interconnection

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION. Reliability Technical Conference ) Docket No.

Transmission Cost Allocation in the Midwest

Last revised: March 1, 2018 TRANSMISSION FUNCTION TITLES AND JOB DESCRIPTIONS

Integrating Renewables

Open Access Technology International, Inc. (OATI)

Job Descriptions. Title & Job Functions: Transmission Function Employees

Renewable Integration at ERCOT

Advancing Renewable Alternatives

Market Monitoring Dr. Robert Sinclair Georgian Energy Policy Delegation

PG&E s General Comments on Demand Response Vision Update. January 11, 2008

SERC. Regional Reliability Plan

Transcription:

SPP at a Glance Located in Little Rock Approximately 600 employees Primary jobs electrical engineering, operations, settlements, and IT 24 x 7 operation Full redundancy and backup site 2

Regulatory Environment Incorporated in Arkansas as 501(c)(6) non-profit corporation FERC - Federal Energy Regulatory Commission Regulated public utility Regional Transmission Organization Must comply with applicable FERC Orders and SPP s approved transmission tariff NERC - North American Electric Reliability Corporation Founding member Regional Entity Must comply with applicable NERC Reliability Standards 3

What is an RTO? Regional Transmission Organizations (RTOs) are independent, non-profit organizations that ensure transmission grid reliability, provide non-discriminatory access to the transmission system, and optimize supply and demand bids for wholesale electric power Minimum characteristics and functions of an RTO are specified in FERC s Order 2000 Participation by electric utilities in RTO encouraged by FERC but not mandated Services provided in accordance with a FERC approved transmission tariff Reliability functions performed in accordance with mandatory FERC approved reliability standards 4

Independent System Operator (ISO) / Regional Transmission Organization (RTO) Map 5

SPP s Membership Profile Category Number Investor Owned Utilities 14 Cooperatives 13 Marketers 12 Municipals 11 Independent Power Producers/ Wholesale Generation 11 Independent Transmission Companies 10 State Agencies 5 TOTAL 76 As of April 11, 2014 6

SPP s Current Operating Region 370,000 miles of service territory 627 generating plants 77,366 MW of generating capacity 46,136 MW of peak demand 4,103 substations 48,930 miles transmission: 69 kv 12,569 miles 115 kv 10,239 miles 138 kv 9,691 miles 161 kv 5,049 miles 230 kv 3,889 miles 345 kv 7,401 miles 500 kv 93 miles 7

2013 Energy Consumption and Capacity Capacity Consumption 12% annual planning capacity requirement 8

Generating Resources in SPP 9

Generating Resources in Arkansas Fossil 10

Annual Average Wind Speed - 80 meters 11 11

Renewable Portfolio Standards 12

SPP s Future Expanded Operating Region Adding 3 new members in fall 2015: Western Area Power Administration, Basin Electric Cooperative, and Heartland Consumers Power District Adds approximately 5-6,000 MW of peak demand Adds about a 50% increase in SPP s current hydro capacity 13

FUNCTIONS 14

SPP s Services and Reliability Functions Today Congestion Management Reliability Coordinator Energy & Ancillary Serv. Markets Balancing Authority Market Monitoring Interchange Coordinator Transmission Service Transmission Provider Generation Interconnection Transmission Planner Transmission Planning Planning Coordinator Future Pursuant to SPP s Transmission Tariff Pursuant to NERC Reliability Standards 15

NERC Functional Definitions Reliability Coordinator Maintains the Real-time operating reliability of the Bulk Electric System within a Reliability Coordinator Area. Balancing Authority Integrates resource plans ahead of time, maintains generation-load-interchange balance within a Balancing Authority Area, and contributes to Interconnection frequency in real time. Interchange Coordinator Ensures communication of Arranged Interchange for reliability evaluation purposes and coordinates implementation of valid and balanced Confirmed Interchange between Balancing Authority Areas. Transmission Provider Administers the transmission tariff and provides transmission services to customers under applicable agreements. Transmission Planner Develops a long-term (generally one year and beyond) plan for the reliability of the interconnected bulk electric transmission systems within a Transmission Planner area. Planning Coordinator Coordinates, facilitates, integrates and evaluates (generally one year and beyond) transmission and resource plans within a Planning Coordinator area and coordinates those plans with adjoining Planning Coordinator areas. 16

Timing of Our RTO Functions Balancing Authority 17

TRANSMISSION PLANNING: BASIC CONCEPTS 18

SPP s Planning Role Perform near and long-term reliability assessments of the transmission system in accordance with NERC TPL Standards Develop annual transmission expansion plans in accordance with Attachment O of the SPP Tariff Recommend transmission expansion plans and projects to the Board for approval Direct construction of Board approved projects (Notification to Construct) 19

What role do state regulators play in SPP? Regional State Committee - Retail regulatory commissioners from: Arkansas Nebraska Oklahoma Kansas New Mexico Texas Missouri Louisiana maintains active observer status Primary responsibility for: Cost allocation for transmission upgrades Approach for regional resource adequacy Allocation of transmission rights in SPP s markets 20

Projects Constructed 2005- May 2014 21

Transmission Construction Statistics # of Upgrades by Voltage Class SPP (All States) Total Cost by Voltage Class # of Upgrades by Voltage Class SPP (Arkansas) Total Cost by Voltage Class Voltage Class Reliability Other Total Reliability Other Total Reliability Other Total Reliability Other Total 500 2 1 3 $51,877,771 $14,000,000 $65,877,771 0 1 1 $0 $14,000,000 $14,000,000 345 45 117 162 $981,590,698 $3,578,969,303 $4,560,560,001 7 4 11 $166,872,100 $51,510,000 $218,382,100 230 53 21 74 $485,166,186 $112,070,425 $597,236,611 0 0 0 $0 $0 $0 161 71 14 85 $254,972,594 $33,512,943 $288,485,537 24 4 28 $95,337,589 $6,552,000 $101,889,589 138 146 88 234 $732,867,750 $391,938,297 $1,124,806,047 0 0 0 $0 $0 $0 115 211 67 278 $1,127,601,376 $337,264,466 $1,464,865,842 1 5 6 $100,000 $3,786,893 $3,886,893 69 158 33 191 $456,240,160 $64,513,405 $520,753,565 0 2 2 $0 $8,321,000 $8,321,000 Totals 686 341 1027 $4,090,316,535 $4,532,268,839 $8,622,585,374 32 16 48 $262,309,689 $84,169,893 $346,479,582 Average Time to Complete Projects* (Years) 100-300 kv 345 kv SPP 3.6 2.4 Arkansas 3.7 4 Longest Time to Complete Projects* (Years) 100-300 kv 345 kv SPP 6.2 5.3 Arkansas 6.2 4.8 *Time to complete is measured from time Notification to Construct is issued, i.e., after project has been approved by SPP Board and completion of competitive bidding process to determine project constructor. It typically takes about one year to perform a planning study and another year to perform competitive bidding process. 23

MARKET OPERATIONS: BASIC CONCEPTS 24

Market Concepts What is a Market? (cont d.) Wholesale Energy Market: Sellers/ Producers Buyers/ Consumers Locational Prices Products Utilities Municipals Independent Power Producers Generators Power Marketers Utilities Municipals Load Serving Entities (LSEs) Power Marketers Driven by Supply and Demand at defined locations Energy Operating Reserves Congestion Rights 25

How SPP s Energy Market Works SPP receives operational pricing information from participating suppliers of energy SPP forecasts how much demand it will have in the upcoming dispatch intervals SPP determines how much energy it needs to meet the demand and dispatches the least cost supplies while respecting operating constraints Utilizes Security-Constrained Economic Dispatch algorithm SPP has the responsibility and ability to dispatch out of economic order for reliability reasons 26

What is congestion? Congestion or bottlenecks happen when you can t get energy to customers along a certain path Desired electricity flows exceed physical capability Congestion caused by: Lack of transmission, often due to load growth Line and generator maintenance outages Unplanned outages such as storms or trees on lines Too much generation pushed to grid in a particular location Preferred energy source located far from customers Results in inability to use least-cost electricity to meet demand 27

Congestion prevents access to lower-cost generation 1/3/2014 01:37:51 PM 500 kv 345 kv 230 kv 28 28