MATTE CONTRACTOR CHOICE PAINT The Matte Contractor Choice C paint is designed for the contractor; it has good performance and opacity. No odor. Has very good brushability, leveling, durability, adhesion and weather resistance. In this line you can collect up to 472 different colors. It has the advantage that each color preparation can be repeated as often as needed, without color variation. This line works with 2 bases: Pastel and Tint. Depending on the color intensity the base will be selected. Due to the high quality of the dyes used, very sharp and clean colors are obtained. Once applied the product, no odors will be detected. TECHNICAL DATA Finishing: Matte Hegman finesse: 3-4 ph: 8.5-9.5 Colors: Available bases: 472 colors Pastel and Tint Theoretical yield: 64 to 75 ft²/l (Note 1) Solids in weight (white): 41 ± 2 % ASTM D 2369-97 Solids in volume (white): 30 ± 2 % ASTM D 2697-86 Presentation: Storage stability: Durability paint film: Bucket, gallon and liter 1 year ASTM D 1849-95 (Note2) 4year in dry environment (Note3) Viscosity @ 25 C: 100-105 UK ASTM D 562-90 Drying at touch times: 60 min. 2 hours to cover (Note4) VOC (pastel base): 15-25 grs/l ASTM D 6093 Density (pastel base): 1.260 ± 0.02 ASTM D 1475-98 Lead and mercury content: 100% free
Resin Type: Vinyl-Acrylic Washability: Greater than 1800 cycles (DIN-53778) It fulfills the NMX-C-423-ONNCE-2003 statements as a C quality paint (Note 1): Applied to 25.4 microns (1 mil) dry on smooth surfaces without waste (white). The actual performance of the paint may vary due to the type of surface to be painted, roughness and porosity of the surface, application method used, working conditions, film thickness, paint waste, among others. There is no guarantee that the practical performance for the user is the expressed in this data sheet, because enforcement operations and surface preparation are out of HRC Inc. control. In vivid colors the actual performance of the paint may decrease by 50% compared to white yields. It is recommended to anchor with an HRC sealer or primer before applying the paint. In spray applications, material losses can reach up to 70%. (Note 2): In tightly closed container stored in a cool, dry place under roof. (Note 3): The durability indicated corresponds to tests made by HRC Inc. under controlled conditions indoors and in dry conditions. Durability depends on environmental conditions, weather, type of substrate, substrate conditions, the form of surface preparation and the application method. The durability may decrease due to natural phenomena -of which HRC Inc. has any controls- such as strong winds, hurricanes, salt, sand, high rainfall, high exposure to ultraviolet rays. This durability means that the paint film does not have the following problems or failures: peeling, blistering or chalking. Shall not be considered as a problem or failure other problems or failures in paintings or outside the product as improper surface preparation, misapplication, wear or failure of the substrate, poor follow installation instructions, discoloration, among other flaws. Some shades may vary over time, especially in applications outside. (Note 4): At 25 C, 50% relative humidity applied at 150 wet microns. SURFACE PREPARATION Every surface before coating should cover the following conditions: must be clean. Remove from the surface any material that prevents paint from adhering to the surface, such as dust, grease, loose paint, rust, mildew, dirt, etc.
Remove all with a wash water pressure, allowing perfectly dry the surface before painting or by mechanical methods such as a wire brush or carding machine all loose or damaged paint. There must be no surface moisture. METHODS OF SURFACE PREPARATION FOR MEDIA TYPE NEW SURFACES Masonry surfaces, concrete, and similar materials. NOTE: These surfaces must be at least 28 days after being cast. Wash the surface with a solution of 1 muriatic acid part by 3 water parts. The solution will effervesce on the surface. Rinse the surface with water to remove the excess of acid. Repeat the procedure until effervescence has stopped. Rinse the surface with water and let dry completely. Measure the ph of the surface and if it is greater than 9, apply a coat of Alfa primary vs high alkalinity PSA-0; if more than 12 apply 2 coats. PREVIOUSLY PAINTED SURFACES Make sure the surface does not present paint peeling, chalking problems or moisture, otherwise remove the materials into the substrate presenting this problems, since may cause failure adhesion of the paint. It should be treated as new surface. Patching holes and cracks and dry the surface. Apply solution of 1 part of muriatic acid by 3 parts of water over the repairs made with cement materials. Rinse perfectly with clean water. Let dry completely and apply the Alfa primary vs high alkalinity PSA-0 on you repair. CONCRETE SURFACES WITH EFFLORESCENCES Identify the source of moisture. Eliminate or control the flow of moisture through the surface. Sometimes it will require a specialist as a plumber, architect or engineer. Remove efflorescence, loose paint and flattened damaged. Repair damaged areas; sometimes it will require a specialist. Treat the surface as new surface. GYPSUM SURFACES WITH CHALKING OR DUSTING PROBLEMS This problem can occur in both old plasters were wetted by water seepage, and new casts that were not installed properly (casts that went wrong diluted to prepare the plaster-water or casts that were beginning to forge mixture.
This results a powdery and soft surface). In the case of new plasters can detect the problem by sanding the walls to eliminate imperfections. The sandpaper will clog and dust will stick as dough in the sandpaper. In these cases should apply the Alfa adhesion promoter primary solvent based. Apply the product diluted 20 to 30% with solvent and allow to dry for 4 to 6 hours. Then apply two coats of paint. Also make sure to clean the dust from sanding the surface with a clean, damp cloth until the surface does not present dusting because otherwise the adhesion of the system will fail, appearing as flaking. APLICATION METHODS Brush, regular roller or microfiber roller. Dilute the paint up to 15% with clean water. Airless Spray: Dilute the paint maximum 20% with clean water. PRECAUTIONS TO CONSIDER BEFORE APPLYING PRODUCT The ambient temperature must be above 10 C and substrate temperature should not exceed 30 C. Relative humidity should be below 85%. Never apply against the sun. Apply in hours where this does not happen, either, use tents or tarps for shade. Do not apply outside if there is rain forecast in the application the following 72 hours. MATERIAL PREPARATION Mix the paint with a clean shovel and stir in a circular motion from the bottom of the container out, trying to seamlessly incorporate all the material until it is free of settlements and have a uniform color. Strain before application. WARNING: DO NOT SMOKE AND NOT TO EAT DURING APPLICATION. IF SWALLOWED DO NOT INDUCE VOMITING. SEEK MEDICAL ATTENTION IMMEDIATELY. AVOID DIRECT CONTACT; THE USE OF THIS PRODUCT BY
CHILDREN SHOULD BE SUPERVISED BY ADULTS. Do not mix with any other material or products other than those listed on this sheet. In the event that during application of the coating, the client came to see any obvious problem in the product such as color difference, product contamination problems in the implementation, freeze, cream, among others, it is your responsibility to suspend the application before it has been applied no more than 100 m², give immediate notice to HRC Inc. and present the facts in writing. Otherwise, HRC Inc. will cover only the amount equivalent to an area not exceeding 100 m² if the product claim is approved. HRC Inc. recommends doing preliminary tests to ensure the results and determine the actual performance in each particular case. Disclaimers According to our best knowledge and research, the technical information contained in this form is true and accurate to date, but subject to change without notice. We guarantee our product according to the specifications outlined above. We make no other warranty including trade and private purposes. The liability is limited to replace the product or refund the purchase amount in case HRC Inc. proceeds to and by presenting the relevant purchase invoice. Labor or the cost of labor and other consequential damages are excluded. Recommended systems for decorative finishes New and Unpainted Masonry (stucco, cement or mortar flattened) Alfa Primary vs high alkalinity psa-0 (ph higher than 10 and maximum 12), 1 to 2 coats. Alfa Sealant vs alkalinity (ph maximum 10), 1 to 2 coats. Already Painted Masonry Alfa Sealant vs alkalinity, 1 coat. New drywall White vinyl tintable primary (at least 1 coat on the pastel tone of the selected color). Already painted sheetrock New plaster Sealant or primary: if while sanding the new plaster the pore of the sand paper completely covers, and also you see dusting in the Wall while cleaning it, use the Alfa Primary adhesion promoter to solve the problem. If this problem is not present, use the Alfa Sealant vs alkalinity.
Already Painted Plaster Alfa Sealant vs alkalinity, 1 coat. New Iron Alfa Workshop Background (solvent based), 1 coat. Already Painted Iron Alfa Workshop Background (solvent based), 1 coat. Glossy surfaces (ceramic, bright enamels) Alfa Primary adhesion promoter. Weathered galvanized sheet least 6-8 months Alfa Primary adhesion promoter. New and Already Painted Wood (only interiors) Alfa Sealant vs alkalinity, 1 coat. Finishing: Selected HRC satin or hi-gloss water based coating, 2 coats.