GUIDANCE DOCUMENT IGNITION RESISTANT EAVE CONSTRUCTION

Similar documents
GUIDANCE DOCUMENT IGNITION RESISTANT EAVE CONSTRUCTION

IGNITION RESISTANT EAVE CONSTRUCTION GUIDANCE DOCUMENT

Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)

SECTION R327.3 STANDARDS OF QUALITY

CITY SECTION 701A 702A. of this chapter. Protection

MEGA FIRES: The Case for Mitigation

Changes to California s Building Code for Construction in Wildfire Prone Areas: Impact on Wood and Wood-based Materials

FOR HOME REPAIR AND CONSTRUCTION

WILDLAND URBAN INTERFACE (WUI) PRODUCTS

Plug any roof openings that are not functioning as vents.

BASIC VENTILATION REQUIREMENTS

CREATING A FIRE ADAPTED HOME

NEWS LETTER MARCH 27, 2009

AG-1.0. M.E. Designs Civil & Structural Engineering Drafting & Design PATRICIA EDWARDS FAMILY TRUST SANTA BARBARA, CA TUNNEL ROAD LANE

Home Assessment Checklist

every year. It s not a matter of IF your

WUIC Proponent: Jason Thompson, National Concrete Masonry Association representing Masonry Alliance for Codes and Standards

MEETING FIRE CODE WITH ORIENTED STRAND BOARD

every year. It s not a matter of IF your

EMRGENCY EXPRESS TERMS BY THE CALIFORNIA DEPARTMENT OF FORESTRY (CDF) & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL (SFM)

Protect Your Property from Wildfire. great lakes Edition

HELP PROTECT YOUR HOME AND BUSINESS

Published by the Authorities Having Jurisdiction listed below. Participating Agencies

Protect Your Property from Wildfire. southern california Edition

Copyright Materials. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

Home Survival in Wildfire-Prone Areas: Building Materials and Design Considerations

ROWHOUSE CONSTRUCTION

Protect Your Property from Wildfire. rocky mountain Edition

Wildfire. Checklist HOME ASSESSMENT. What to know and what you can do to prepare.

Central U.S. edition. Protect Your Property from Wildfire

mid-atlantic/northeast edition Protect Your Property from Wildfire

southeast edition Protect Your Property from Wildfire

HELP PROTECT YOUR HOME AND BUSINESS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

Common Applications: FRT plywood Type X Gypsum wall board

Pacific Northwest edition. Protect Your Property from Wildfire

Montana Department of Natural Resources and Conservation Structure Assessment Form

MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR. WILDFIRE EXPOSURE

YOUR HOME AND BUSINESS

REDUCING WILDFIRE RISKS IN THE HOME IGNITION ZONE

R-Matte Plus-3: Insulation for the Building Envelope

ROME ART AND COMMUNITY CENTER

UDC Wall Bracing Provisions Emergency Rule effective date 4/1/2014. A How To guide for use of the new provisions

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

INTERIOR FINISHES CHAPTER 8

Roofing City of Owatonna BUILDING DEPARTMENT

This document was prepared by. Acknowledgements. Cover photo: Anchor Point Group, Boulder, CO

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

HELP PROTECT YOUR HOME AND BUSINESS

FIREBLOCK/DRAFTSTOPPING INFORMATION CODE INFORMATION FOR 1 & 2-FAMILY DWELLINGS FOR WOOD-FRAMED CONSTRUCTION FIREBLOCK

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Community Wildfire Hazard Assessment and Rating Field Guide

Understanding Energy Codes

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Fiber Cement Collection. AlluraUSA.com

Vulcan Vent - Self-Closing, Intumescent Exterior & Interior Vents for Fire Protection of Buildings & Homes

Presents. Roofing Basics

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

INTERIOR FINISHES CHAPTER 8 SECTION 801 GENERAL

GYPSUM BOARD AND PLASTER

Water Intrusion Into Buildings Forensic Investigations

Three Coat Stucco System

application instructions

RECREATIONAL EAGLE CENTER METAL ROOF ASSESSMENT AND SOLUTION

Natural Gas Service Installation and Meter Clearance Requirements

SOUTH AFRICAN NATIONAL STANDARD

CHAPTER 6 TYPES OF CONSTRUCTION

Differences between EnCon Insulated Precast and EIFS

EXTERIOR WALLS CHAPTER 14

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

EXHIBIT A HOMEOWNER NAME: ADDRESS: LOT NO: DATE: PROPOSED START DATE: ANTICIPATED COMPLETION DATE: NAME OF CONTRACTOR: CONTRACTOR S LICENSE NUMBER:

PLASTIC CHAPTER 26. SECTION 2602 DEFINITIONS Definitions. The following terms are defined in Chapter

FIRE SAFE SONOMA. Living with Fire And SOD In Sonoma County

NFL Building Sloped Roof Replacement

RESIDENTIAL DETACHED ACCESSORY STRUCTURES

Interior FRT Wood. References of Previous Model Building Codes

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

CHECKLIST Inspecting a Garage

FIREWISE USA RECOGNITION PROGRAM COMMUNITY WILDFIRE RISK ASSESSMENT

Copyright Materials. Fire-Rated Cementitious Coated OSB in Wall and Roof Sheathing Applications

CWPP Components associated with Structures

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

FIREWISE USA RECOGNITION PROGRAM COMMUNITY WILDFIRE RISK ASSESSMENT

Code Compliance Research Report CCRR-0231

The better way to build TM. Installation Manual NAILBASE PANELS

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: MATERIAL DISTRIBUTOR COMPANY, INC.

Envelope Highlights Mandatory Measures Prescriptive High Performance Walls 150.1

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

Fire Adapted Communities on the Plains. Master Volunteer Forest Steward Course Lisa Mason, Colorado State Forest Service April 22, 2014

Building Division Informational Handout

Home design and retrofitting. techniques for wildfire defense

Transcription:

GUIDANCE DOCUMENT IGNITION RESISTANT EAVE CONSTRUCTION Since the 1980s, the County s fire and building codes have been strengthened in successive code adoption cycles with the primary goal of protecting the safety of our citizens and enhancing a home s ability to survive a wildfire. Although such measures protected many homes located within the areas impacted by the 2003 and 2007 wildfires, analysis of the burned homes identified areas where we could improve our codes; one of these areas is eave construction. Winds in wildfires carry huge amounts of burning embers, swirling into cracks and crevices, igniting anything that is combustible. Eaves, because they are perpendicular to the wall, tend to capture blowing embers. Eave vents, which are designed to move air in and out of the attic, give opportunity for embers to ignite soffit material or enter attic areas. Once a fire starts in an attic, it goes undetected for some time and is very difficult to stop even under ideal conditions. As a result, improvements were made to the County s codes to establish a series of permissible ignition resistant eave construction details. To determine which detail will be allowed on your structure, first determine whether you are able to maintain 100 feet of defensible space completely around the structure in accordance with the Fuel Modification requirements of section 4707.2 of the County Fire Code. The fuel modification zone shall be located entirely on the subject property. When 100 foot of defensible space will be provided any of the details listed in the following Ignition Resistant Eave Construction chart may be used. When 100 foot of defensible space is not provided. While it is always desirable to have at least 100 feet of defensible space around all structures in the Wildland-Urban Interface Fire Area, there are situations where the required fuel modification cannot be achieved on the parcel, or where steep terrain, high fuel loads, or other special circumstances create additional hazard. In these cases only the most ignition resistive details may be used. Once you have determined the amount of defensible space that can be created on your property, consult the attached Ignition Resistant Eave Construction chart for a listing of the different types of eave construction that will be allowed for your structure. For every eave description in the chart there is a corresponding detail attached. In addition, each detail can be downloaded individually in AutoCAD DWG file format at: http://www.co.san-diego.ca.us/dplu/bldgforms/eaveindex.html. Eave construction on an addition may match the existing structure provided that the area of the addition does not exceed 50% of the existing structure or 2,500 square feet, whichever is less. The vents in these eaves must still comply with current County codes requiring resistance to intrusion of flames and embers. While these standards will provide a high level of protection to structures built in the wildland-urban interface area, there is no guarantee that compliance with these standards will prevent damage or destruction of structures by fire in all cases. For more information on eave construction or other fire code requirements, please refer to the Wildland-Urban Interface 2008 Code Changes handout (DPLU #664) or contact the Fire Services Division at (858) 565-5920. 5201 RUFFIN ROAD, SUITE B, SAN DIEGO, CA 92123 (858) 565-5920 (888) 336-7553 HTTP://WWW.SDCDPLU.ORG HTTP://LANDINFO.SDCOUNTY.CA.GOV DPLU #198 (09/17/2008) Page 1 of 16

IGNITION RESISTANT EAVE CONSTRUCTION # EAVE CONSTRUCTION DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 Stucco Soffit with Fascia Protected. Horizontal soffit or angled overhang and 2x fascia enclosed with 7/8 Portland cement plaster Stucco Soffit with Fascia Exposed. Horizontal soffit or angled overhang with 7/8 Portland cement plaster, exposed 2x fascia Foam Trim with Stucco. 7/8 Portland cement plaster with foam trim over brown coat and enclosed with color coat Heavy Timber. Exposed rafter tails (4 x 6 or larger), supporting 2" T&G roof decking (If fascia is used it must be 3 x 6 or larger) Exposed Wood with Drywall Underlayment. Soffit enclosed with ½ Type X gypsum wallboard under 1x smooth finished starterboard, tight-fitting or caulked. 2x fascia. Wood Soffit, Fascia Exposed, with Fire-Resistive Underlayment. 2x wood fascia as plant-on over 5/8 Type X gypsum wallboard or 7/8 Portland cement plaster or 2-2x wood blocking. Soffit may be constructed of combustible material with a 1/4 minimum thickness over 5/8 Type X gypsum wallboard or 7/8 Portland cement plaster. Cementitious Siding on Soffit and as Underlayment Behind Fascia. 1/4 min. thickness non-combustible cementitious siding on soffit. 2x wood fascia installed over backing of cementitious siding backing or other backing as approved in detail #6. Cementitious Siding on Soffit 1/4 min. thickness noncombustible cementitious siding 2x fascia without underlayment Enclosed Eave with Exposed Wood. Enclosed eave with solid combustible materials (wood) ¾ inch thickness no exposed rafter tails. All joints must be tight fitting and gaps caulked. Open Eave with Exposed Wood. 2x rafter tails with 2x blocking, and 1x exterior grade starterboard or 1/2 CCX plywood. All joints must be tight fitting and gaps caulked. Fire Retardant Treated Wood Fascia. 1/4 min. thickness non-combustible cementitious siding or 7/8 Portland cement plaster on soffit. 2x Fire Retardant Treated Wood fascia installed over 2x non- treated backing block. DPLU #198 (09/17/2007) Page 2 of 16 WITH 100 WITHOUT 100 Eave Allowed? Vent Allowed? Eave Allowed? Vent Allowed? Y Y 1 Y N 2 Y Y 1 NOT ALLOWED Y N Y N 2 Y N Y N 2 Y Y 1 NOT ALLOWED Y Y 1 Y N 2 Y Y 1 Y N 2 Y Y 1 NOT ALLOWED Y Y 1 NOT ALLOWED Y Y 1 NOT ALLOWED Y Y 1 Y N 2 1 Vents are allowed in the eave assembly only under either of the following conditions: a) The vents are constructed to resist the intrusion of flames and burning embers. b) When approved by the Building Official and the Fire Official, enclosed eaves may be vented on the underside of the eave closest to the fascia provided the closest edge of the vent opening is at least 12 inches from the exterior wall. 2 Exception: Vents are allowed in these eave assemblies only when they are constructed to resist the intrusion of flames and burning embers.