PG Series Gaskleen Purifier Assemblies and Manifolds

Similar documents
NANOCHEM Purifiers. Complete Purification Solutions with

PRESSURE REGULATOR AND VALVE SELECTION GUIDE

Your Authorized West Coast Distributor:

TKF GAS FILTER SERIES. Hastelloy Gas Filter Stainless Steel Gas Filter PTFE Gas Filter IGS Gas Filter Gasket Filter

0.01 Micron Membrane Filters

Mott GasShield Filters made with Hastelloy C-22 alloy For unsurpassed strength and resistance to corrosion

Equipment. Description. Features. Ordering Information. indicating oxygen trap Series 6200

For highest levels of purity

TKF Gas Filter Series. Hastelloy Gas Filter Stainless Steel Gas Filter PTFE Gas Filter IGS Gas Filter Gasket Filter

MATERIALS OF CONSTRUCTION

SEMI Draft Document 4538 REVISION OF SEMI F GUIDE FOR METALLIC MATERIAL COMPATIBILITY IN GAS DISTRIBUTION SYSTEMS

Sherwood Valve Specialty Gas Products

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

mott corporation High Purity Products IGS Porous Metal Filters and Flow Restrictors.

APPLICATIONS BENEFITS INTELLIGENT

Variable Area Flowmeters Model 28

TRACE ANALYTICAL. ta7000 Series UHP Gas Purity Monitors At the critical link in your manufacturing process. Features /Benefits

Aeronex Gas Purification System HX Series

Cash Valve. Type C-776. ASME Section VIII Air/Gas and Cryogenic, UV National Board Certified Safety Valve. Flow Control

HEALTH ISOBUTANE PHOSPHINE HELIUM OXYGEN NEON ENVIRONMENT SULFUR DIOXIDE CARBON DIOXIDE MEDECINE N-BUTANE ETHYLENE BEVERAGE TETRAFLUOROMETHANE

Super Clean Gas Filters Simply the best

Dräger Gas Filtration SUPER CLEAN GAS FILTERS. Dräger: Technology for Life

Pall PROFi Craft System Best Filtration for Best Beers

Advanced Spectroscopic Solutions for Fuel Cell Hydrogen Analysis

3M Meridian Sensor Specifications

Profile A/S Series Filter Elements

Gas Filtration Catalogue

Hydrogen fuel Product specification. Part 2:

HD and HDL Two-Stage Non-Lube Gas Compressors

CYLINDER CONNECTORS.

Gases & Applications

INDUSTRIAL AND ULTRA PURE GAS PURIFICATION

Super Clean TM Gas Filters

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND

Positioned for the next challenge in ultra-pure filtration.

SERIES AK 1400T SINGLE STAGE PRESSURE REGULATOR TIED DIAPHRAGM SAFETY AND RELIABILITY

Measuring moisture in ultra-high-purity gases

Super Clean Gas Filters Simply the best

Lab Design or Renovation Plans Interview/ Review

HIGH PURITY REGULATORS

Calibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors

PROCESS ANALYZERS FOR PURIFIED BULK GAS QC/QA: ENTERING THE PPT RANGE

TECH 50 SPECIFICATION

Fast Refinery Gas Analysis Using the Agilent 490 Micro GC QUAD

High Brightness Light Emitting Diode (HBLED) Total Value Chain

Moisture removal from hydrogen chloride (HCl) gas

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

Special Applications. Special Applications. ENVIRONMENTAL MONITORING. EPA Instrumental Test Methods as Defined by 40 CFR Part 60

Series SFA100/200/300

Background Statement for SEMI Draft document 4734A NEW STANDARD: SPECIFICATION AND GUIDE FOR BORON TRICHLORIDE (BCl3)

GAS CHROMATOGRAPH FOR MULTIPLE IMPURITIES

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

organic gases and vapors with a boiling point > 65 C particles brown white

MODEL PFC-80. Flow Solutions

Filtration and Purification Solutions for the Total Photovoltaic Value Chain

Crossflow Filtration for Ink Jet Fluids

For our Environment GWP 1. Chemical nomenclature Formula / Composition. Industrial nomenclature

pressure regulators Single Stage Pressure Regulators Safety Warning Inside Front Cover Index

Compressed Air Filters Sample Filters

RESP_IRR_20 P Package

On-Line Gas Analysis In Air Separation Plants

Performance Data on Jet Compressors

CONOFLOW HIGH-PRESSURE REGULATOR - HP500 Pressure Reducing - Diaphragm Type - High Purity

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas

Leading in electronic gases. Supplying the semiconductor, solar, display, and LED markets

March 2016 ARM, Inc. white paper: Safe Approach to Gas Purification. Abstract

Premium Performance Direct Spring Valves Series 60 and 80 - Sizing ANDERSON GREENWOOD. Note. How to Size a Valve

SCOTTY Brand Transportables Convenient, Cost-Effective Calibration Gases

3M Purification Inc. 3M High Flow Series Filter Systems

Electron Capture Detector for GC-2010 Plus

pressure regulators HPR-2 Series Introduction Steam Heated Regulators

DUPLEX SERIES. Ultra-High Purity Diaphragm Valves (DPC) Ultra-High Purity Bellows Valves (DFC) Ultra-High Purity Block Bellows Valves (DBC)

OXYGEN TRAPS MOISTURE

Gas purification systems for the highest level of purity

Advanced Melt Blowing Technolog y

CSI G SYSTEMS CSI GAS DELIVERY SUPPORT. Chemical Vapor Deposition (CVD)

Compact design Smaller housing minimises capital expense requirements Reduces system footprint. Up to 50% smaller than competitively sized housing.

Practical Gas Chromatographic Analyses Using ICP-MS Detection

Trace PRODUCT NOTE

Miniature Helium Purifier and Nitrogen Purifier Instruction Manual

SPARK TM MOISTURE ANALYZER VALIDATION Performed in Conjunction with Air Products and Chemicals, Inc.

TTE N TTE N

A LOW PRESSURE DROP SINTERED METAL FILTER FOR ULTRA-HIGH PURITY GAS SYSTEMS

JRHL Series. Pressure Reducing Valves for Low Flow and Low Pressure Process Gas GAS PRESSURE REDUCING VALVE. Features

Agilent 490 Micro GC Biogas Analyzers

MODEL PFC-50 AND PFC-60. Flow Solutions

Large Valve Oven Analyzers for Refinery Gas Analysis. ASTS 2015 Houston Shannon Coleman Application Specialist Agilent Technologies

Austro Energy Systems Int. AG. Gas reformer AES3000

The MIDAC Low Moisture in Corrosive Gases Process Analyzer for Continuous On-Line Applications

GAS DETECTION SYSTEMS

FIBA Technologies, Inc.

Appendix 1 PROPERTY TABLES AND CHARTS (SI UNITS)

D DAVID PUBLISHING. Hydrogen Gas Purifiers for Fuel Cells. 1. Introduction. 2. Scientific Approach

Online dissolved gas analysis sensor

Item Hydrogen Gas Plant

Recent developments on quality assurance of fuel cell hydrogen

IR4015 Stainless Steel High Pressure Regulator, Internally Threadless Design Regulator

Sho-Rate TM Models 1250 & 1255

Transcription:

Gas Purification Assemblies Data Sheet MEPGGPENd PG Series Gaskleen Purifier Assemblies and Manifolds Description Pall s Gaskleen PG purifier assemblies have been designed to handle process flow rates up to, slpm. An optional bypass manifold is available complete with isolation valves and backplate for easy mounting. Pall s purification materials are available in every standard configuration. All purifier assemblies contain an integral 3L stainless steel particle filter. % helium leak and pressure tested. No detectable metal contribution above background in HCl gas with HCLP material No detectable metal contribution above background in HBr gas with HBRP material Specifications Assembly Flow Rates PG55: 75 slpm PG: 5 slpm PG:, slpm List of Purifiable Gases Particle Filter Options PG55/PG:. µm or.3 µm PG:. µm Connections in or in gasket seal (VCR or compatible) male/male Inlet/outlet isolation valves (for PG) Assembly Material Electropolished 3L SS <.5 µm/< µin Ra internal surface finish Operating Conditions Maximum operating pressure PG55/PG: 3.5 MPa/5 psig PG:.7 MPa/5 psig Maximum operating temperature: C/ F (INP, SIP, FCP, SFP), C/ F (NH3P, GEHP, OXP, CLXP, HCLP, HBRP, CDAP) EU Pressure Equipment Directive: Assemblies have been evaluated for compliance with the European Union s Pressure Equipment Directive 97/3/EC and are CE-marked. VCR is a trademark of Swagelok Co. Gas Family Material Effluent Specification Nitrogen, argon, helium, xenon, krypton, neon INP < ppb H O, O, CO and CO Silane, hydrogen, methane, cyclopropane, propane, dimethyl ether SIP < ppb H O, O, CO and CO Carbon monoxide SIP < ppb H O, O, CO, Ni(CO), and Fe(CO) 5 Fluoromethane, difluoromethane, trifluorine, tetrafluoroethane, FCP < ppb H O, O, CO and CO pentafluoroethane, heptafluoropropane, carbon tetrafluoride, perfluoropropane, perfluorocyclobutane, hexafluoroethane Ammonia NH3P < ppb H O, O, CO and CO Germane GEHP < ppb H O, O, CO and CO Sulfur hexafluoride SFP < ppb H O, O, CO and CO Air, carbon dioxide, oxygen, nitrous oxide OXP < ppb H O Boron trichloride, chlorine, trichlorosilane, dichlorosilane CLXP < ppb H O Hydrogen chloride HCLP <5 ppb H O Hydrogen bromide HBRP < 5 ppb H O Photolithography clean dry air CDAP < ppb H O, < 3 ppt organics (as C ), < ppt acid gases (as SO ), < 5 ppt basic gases (as NH 3 ), < ppt refractory compounds (as HMDSO) As tested in inert gas.

Pressure Drop vs. Gas Flow Rate..5..5..5 5. 7 5. 3 kpa/5 psig inlet. 35. 3. 5. 5. 3 7 kpa/3 psig inlet 5.. 5.. 55 kpa/ psig inlet.5 5. 37.5 5..5 75. Nitrogen flow rate (in slpm @ C and atm) PG55 with.3 µm filter..5..5..5.. 3 kpa/5 psig inlet.5...75.. 7 kpa/3 psig inlet 55 kpa/ psig inlet.5.5..5 5. 37.5 5..5. 75. Nitrogen flow rate (in slpm @ C and atm) PG55 with. µm filter.......... 3 kpa/5 psig inlet.. 7 kpa/3 psig inlet 55 kpa/ psig inlet... 5 5 5 3 35 5 5 Nitrogen flow rate (in slpm @ C and atm) PG VMM with.3 µm filter.......... 3 kpa/5 psig Inlet 7.. 7 kpa/3 psig Inlet 5.. 3. 55 kpa/ psig Inlet... 5 5 5 3 35 5 5 Nitrogen flow rate (in slpm @ C and atm) PG VMM with.3 µm filter.......... 7.. 5.. 3. 3 kpa/5 psig inlet 7 kpa/3 psig inlet.. 55 kpa/ psig inlet. 5 5 5 3 35 5 5 Nitrogen flow rate (in slpm @ C and atm) PG VMM with. µm filter.......... 7.. 3 kpa/5 psig inlet 5.. 3.. 7 kpa/3 psig inlet. 55 kpa/ psig inlet. 5 5 5 3 35 5 5 Nitrogen flow fate (in slpm @ C and atm) PG VMM with. µm filter. 5.. 5.. 5. 3. 35.. 7. 3 kpa/5 psig Inlet. 5.. 3.... 3 5 7 9 Nitrogen flow rate (in slpm @ C and atm) PG Series assembly 7 kpa/3 psig Inlet 55 kpa/ psig Inlet Note: For pressure drop information for a specific application, please contact Pall Microelectronics.

Lifetime Calculations 75..5 5. 37.5 5..5 ppm ppm ppm.,,,,, Gaskleen PG55 purifier assembly, part # GLP9INPVMM Inlet pressure: 7 kpa (3 psig) contaminant challenge as H O 5 5 35 3 5 5 5 ppm ppm ppm,,,,, Gaskleen PG purifier assembly, part # GLPINPVMM/VMM Inlet pressure: 7 kpa (3 psig) contaminant challenge as H O 9 7 5 3 ppm ppm ppm,,,,, Gaskleen PG purifier assembly, part # GLPINPVFM Inlet pressure: 7 kpa (3 psig) contaminant challenge as H O Note: For lifetime calculations in a specific application, please contact Pall Microelectronics. Nominal Assembly Dimensions. mm. in 99. mm 39. in.7 mm 7.9 in 39. mm 7.3 in ø7. mm ø3. in PG55 Note: For manifold dimensions, please contact Pall Corporation. ø. mm ø. in PG ø5. mm ø. in 5. mm. in PG

Technical Information Impurity Removal as Tested in Specific Gases Specific Gas Inert gases: nitrogen, argon, helium, xenon, krypton, neon Flammable gases: silane, hydrogen, methane, ethane, cyclopropane, propane, dimethyl ether Carbon monoxide Ammonia Fluorocarbons: fluoromethane, difluoromethane, trifluoromethane, tetrafluoroethane, pentafluoroethane, heptafluoropropane, carbon tetrafluoride, perfluoropropane, perfluorocyclobutane, hexafluoroethane Germane Sulfur hexafluoride Oxygenated gases: carbon dioxide, oxygen, nitrous oxide, clean dry air Chlorinated gases: boron trichloride, chlorine, trichlorosilane, dichlorosilane Halogenated gases: hydrogen chloride, hydrogen bromide Photolithography clean dry air Impurity Removal Efficiency < ppb H O, CO, O, and CO, as tested in argon and < ppb H O, CO, O, and CO, as tested in argon, nitrogen and hydrogen using APIMS analyzer < ppb H O, as tested in carbon monoxide using trace moisture analyzer H O and siloxanes removed to trace levels, as tested in silane using APIMS < ppb Ni(CO), and < ppb Fe(CO) 5, as tested in carbon monoxide using GC-ECD analyzer < ppb H O, CO, and O, as tested in argon using APIMS < ppb H O, as tested in ammonia using NIR-TDLAS Removal of O and CO to trace levels, as tested in ammonia using GC-DID < ppb H O, CO, O, and CO, as tested in argon and < ppb O, as tested in trifluoromethane using trace oxygen analyzer < ppb H O, as tested in trifluoromethane using trace moisture analyzer and FTIR < ppb H O, CO, O, and CO, as tested in argon and < ppb H O, CO, and O, as tested in argon using APIMS < ppb H O < ppb H O, and CO, as tested in argon using APIMS analyzer < ppb H O < ppb H O, and CO, as tested in argon using APIMS analyzer < 5 ppb H O as tested in hydrogen chloride using CRDS < 5 ppb H O as tested in hydrogen bromide using CRDS < ppb H O as tested in argon using APIMS analyzer < ppb H O as tested in argon using APIMS analyzer < 3 ppt C H as tested in argon using APIMS Analyzer < ppt SO as tested in nitrogen using ion chromatograph < 5 ppt NH 3 as tested in nitrogen using ion chromatograph < ppt HMDSO as tested in argon using APIMS analyzer and baseline subtraction Unit conversion: bar = kilopascals

Part Numbers / Ordering Information Series Part Number 3 Description PG55 GLP9xxxxFVMM Purifier assembly, 75 slpm,.3 µm filter, in gasket seal (VCR or compatible) male/male GLP9xxxxFMAN GLP9xxxxFVMMGCMAN Bypass manifold with GLP9xxxFVMM assembly Gas cabinet manifold with GLP9xxxFVMM assembly GLP9xxxxVMM Purifier assembly, 75 slpm,. µm filter, in gasket seal (VCR or compatible) male/male GLP9xxxxMAN GLP9xxxxVMMGCMAN Bypass manifold with GLP9xxxVMM assembly Gas cabinet manifold with GLP9xxxVMM assembly PG GLPxxxxFVMM Purifier assembly, 3 slpm,.3 µm filter, in gasket seal (VCR or compatible) male/male GLPxxxxFVMM GLPxxxxFMAN Purifier assembly, 3 slpm,.3 µm filter, in gasket seal (VCR or compatible) male/male Bypass manifold with GLPxxxxFVMM assembly GLPxxxxVMM GLPxxxxVMM Purifier assembly, 5 slpm,. µm filter, in gasket seal (VCR or compatible) male/male Purifier assembly, 5 slpm,. µm filter, in gasket seal (VCR or compatible) male/male GLPxxxxMAN Bypass manifold with GLPxxxxVMM assembly PG GLPxxxxVFM Purifier assembly,, slpm,. µm filter, in gasket seal (VCR or compatible) female inlet/male outlet GLPxxxxMAN Bypass manifold with GLPxxxVMM assembly 3 See list of purifiable gases on page. Example: GLP9INPFVMM. The PG stainless steel assembly (used with all GLP part numbers) is fabricated in accordance with the ASME BPVC Section VIII, Division, and has a U-stamp. If the user determines that an L-stamp is required for a lethal service application, please contact Pall Microelectronics for cost and availability. 5 Harbor Park Drive Port Washington, New York 5 USA +..3.755 toll free (toll free in USA only) +.5..3 phone +.5.5.3 fax microelectronics@pall.com Visit us on the Web at www.pall.com/micro Pall Corporation has offices and plants throughout the world. For Pall representatives in your area, please go to www.pall.com/contact.asp Because of technological developments related to the products, systems, and/or services described herein, the data and procedures are subject to change without notice. Please consult your Pall representative or visit www.pall.com to verify that this information remains valid. Products in this document may be covered by the following patent number: US 7,5,9 Copyright 7,, Pall Corporation. Pall,, and Gaskleen are trademarks of Pall Corporation. Indicates a Pall trademark registered in the USA. Filtration. Separation. Solution.SM is a service mark of Pall Corporation. MEPGGPENd December