Electrical Protection Methods and Devices SAMPLE. Learner Workbook Version 1. Training and Education Support Industry Skills Unit Meadowbank

Similar documents
ELECTRICAL INSTALLATION DESIGN Three Day Course with option to achieve BTEC Advanced Award

* All equipment grounding conductors shall be tested for continuity and shall be electrically continuous.

Hazards. Hazards. Hazards. Effects on the Body. GA Tech Electrical Safety Presentation

Electrical Heating SAMPLE. Learner Workbook. Version 1. Training and Education Support. Industry Skills Unit. Meadowbank. Product Code: 5639

NZQA registered unit standard version 6 Page 1 of 5

Reference Information:

APPLICATION NOTE 6. Use of Decouplers for AC Voltage Mitigation. PART 2: DESIGN CONSIDERATIONS

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE:

Arc Flash Risk in Wind Energy Systems. Guidelines for analysis, mitigation and management

NZQA unit standard version 1 Page 1 of 5

HIGH RESISTANCE GROUNDING THE ONLY TECHNOLOGY THAT PREVENTS ARC FLASH

Grounding Principles. The need to ground! Definitions. Introduction. Grounding Codes and Standards. 2 Ph:

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

GN7 Amendment 3-5 Agricultural and horticultural premises

Substation Design Volume X

PREFACE. General precautions

4. POINTS ON SWITCH AND CIRCUIT BREAKER PLATFORM GROUNDING.

2017 NEC Changes for Renewable Energy Systems Session one by Christopher LaForge

COUNTY OF RIVERSIDE BUILDING AND SAFETY DEPARTMENT PHOTOVOLTAIC PERMITTING GUIDELINES

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Electrical Principles and Technologies Unit D

Electrical Grounding In Mining Applications

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

electrical engineering division Arc Flash Study Planning Kit Everything You Need To Ensure The Success of Your Arc Flash Project

PHOTOVOLTAIC (PV) SUBMITTAL REQUIREMENTS

SAMPLE. MEM05019D Weld using gas tungsten arc welding process. Learner guide. MEM05 Metal and Engineering Training Package.

INSTRUCTION MANUAL FOR WIRE WELDING MACHINE

GROUNDING SYSTEMS. Design & Application Nov 2018, Dubai Nov 2019, Dubai

Earthing in electrical network purpose, methods and measurement

Required Text Books per Unit for Course 20222

MEM05018C Perform advanced welding using gas metal arc welding process (Aluminium edition) SAMPLE

ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER:

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 705 AGRICULTURAL AND HORTICULTURAL PREMISES

Persons Working On or Near to AC Electrified Lines

GRADE 9: Physical processes 2. UNIT 9P.2 12 hours. Electricity and energy. Resources. About this unit. Previous learning.

GUIDELINES FOR SUB-SYSTEM COMPLETION CERTIFICATES AND TEST RECORDS FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

Power Plant. Project. ISU Senior Design Group: DEC Project Sponsor: CIPCO Project Advisor: Professor Mani Mina

UNIT I PHYSIOLOGYAND TRANSDUCERS

Information Document Protection System Information ID# R

Guidance on Signalling and Safety-Related Telecommunications Power Supplies and Circuits

Electrical Safety. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Electrical installations Marinas and boats

Operation & Safety manual

UPS installation safety requirements

NFPA 70E Compliance: A Systems Approach

Arc Welding and Cutting OSHA Standard

NFPA 70E 2018 TOP CODE CHANGES

INFORMATION PROVIDED TO ASSIST THE TENDERER FOR THE SUPPLY OF:

Amendment A National Electric Code

Toolkit 2 - Apprentice Training and Profiling

Part 1: On-land pipelines

DESIGN OF MV OVERHEAD LINES TO MAXIMISE BIRD SAFETY

Accreditation No: LAB 041. Electrical Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan.

AS3000:2017 Changes. What you need to know

ELECTRICAL SAFE WORK PRACTICES

Substation Grounding. Presented by: Bruce Kayser, PE Assisted by Danny Seele

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

AMENDMENT OF MALAYSIAN STANDARD MALAYSIAN STANDARD MS :2009

ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL170A USER MANUAL DEALER:

WITH THE TITLE 24. replacement. story. stories, etc. R disconnects. to, PV. unit and any. supporting frame. conditions. greater than the main

Agilent 16034E Test Fixture

High-efficiency & low consumption Solar Water Pumps ATLANTS9000SF Series Introduction:

Grounding and Bonding in Boats and Marinas A Vital Link to Safety Capt. David E. Rifkin and James D. Shafer

Safety Concerns with New

FIELD TEST AND OPERATIONAL CHECK SECTION A. Refer to Section 16010, Electrical General Requirements.

Sticklers for Safety. Sep 17, 2014Van Wilkins Electrical Construction and Maintenance

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

Basic Electrical Theory by: Brian H. Hurd. Work

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on

TECHNICAL SPECIFICATION

OPERATING MAINTENANCE INSTRUCTIONS

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Mark Rzasa & Tom Malerich Peoria Area OSHA Office

PART MATERIAL REMARK Metal Case with Pig-tail. Brass (Metal Case) Copper (Pig-tail) Star Contact Copper Silver Plated

Name: Phil Langlois Position: Lead Electrical Engineer, Ontario Operations

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

Also includes - Auxiliary Contacts & Shunt Trip - RCCB and - Distribution Boards

SECTION FIELD PANELS

GENERAL INFORMATION ABOUT RESISTANCE THERMOMETERS

6/6/2017 ELECTROSURGERY OBJECTIVES. Electro Surgery Unit Safety Copyright Chesapeake Bay Perioperative Consortium,

SRI LANKA STANDARD SPECIFICATION FOR THREE-PIN PLUGS, SOCKET-OUTLETS AND SOCKET-OUTLET ADAPTORS

Name: New Document 1. Class: Date: 87 minutes. Time: 87 marks. Marks: Comments:

Paragraph/ Figure/Table

(Condensed from National Electric Code)

Same as Client Address. 40, Havelock Close. India Way. London. Postcode: W12 7NQ

TallSlateTM Grandee Installation Manual

Same As Client Address SPECIMEN. operational limitations. of the inspection and. agreed with):

MEM05047B Weld using flux cored arc welding process

SAMPLE. Weld using flux cored arc welding process (MEM05047B) LEARNING RESOURCE MANUAL. Metal Fabrication & Welding T INDUSTRY SKILLS UNIT MEADOWBANK

SECTION 16080P - ELECTRICAL TESTING

UPS Electrical Design and. Installation. critica POWER SUPPLIES

ASSOCIATED PRODUCTS. Roof Clips (50 ea) Downspout Hanger Bracket ALSO AVAILABLE FOR PIPES

Substation Grounding Tutorial

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 11/10/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Transcription:

Electrical Protection Methods and Devices Learner Workbook Version 1 Training and Education Support Industry Skills Unit Meadowbank Product Code: 5635

Table of Contents Introduction... 5 1. Protection for Safety... 7 Review Questions... 21 2. Earthing... 23 Review Questions... 42 3. Further Protection Against Indirect Contact... 45 Review Questions... 52 4. Revision, Consolidation and Assessment 1... 55 Sample Theory Test 1... 56 5. Over Current, Undervoltage and Overvoltage Protection... 63 Review Questions... 80 6. Protection Devices Fuses... 83 Review Questions... 95 7. Protection Devices Circuit Breakers... 97 Review Questions...109 8. Protection Devices Residual Current Devices... 111 Review Questions...126 9. Revision, Consolidation and Assessment 2... 129 Sample Theory Test 2...130 Review Questions - Answers...141 Sample Theory Test 1 - Answers...147 Sample Theory Test 2 - Answers...150 Resource Evaluation Form... 155 TAFE NSW (Training & Education Support Industry Skills Unit, Meadowbank) 2012

1. Protection for Safety Purpose In any electrical installation there is an ever present risk of injury and/or damage from the physiological, thermal and magnetic effects of electric current and from mechanical movement associated with electrical devices and machines. This section introduces the methods required by the Wiring Rules to protect against these risks. Objectives At the completion of this section you should be able to: list the factors influencing the severity of an electric shock describe the effects of current flowing through a human body define the terms touch voltage and touch current explain the thermal effect of current and the hazards of overload current, fault current, arcing and poor electrical connections describe the effect of grouping cables list the precautions to be taken to protect electrical installations, structural and associated materials and persons from burns produced by heat in electrical equipment (thermal effect of current) explain how the fire (rating) integrity of a structure shall be maintained in relation to the electrical installation describe the hazards associated with mechanical movement associated with electric motors and the measures taken to mitigate the hazard define the terms direct contact and indirect contact provide examples of where and how a direct contact with live parts may occur in an electrical installation provide examples of where and how an indirect contact with conductive parts may occur in an electrical installation list the methods of protection against direct contact in an electrical installation describe the methods of protection against indirect contact in an electrical installation. TAFE NSW (Training & Education Support, Industry Skills Unit Meadowbank) 2012 Page 7 of 158

1. Introduction Learning Activities To help you learn the material in this section there are blank spaces for you to write the appropriate information from the references given. The Wiring Rules AS/NZS 3000 set out the standards for electrical installations to function safely. As an introduction to this section, complete the following statements by referring to Section 1 of the Wiring Rules. (a) The title of Section 1 of the Wiring Rules is: (b) (c) The Scope of the Wiring Rules, as outlined by Clause, sets out the minimum requirements for the design, construction and testing of electrical installations. The requirements of the Wiring Rules are intended to protect: The principal application of the Wiring Rules, as outlined by Clause, relates to electrical installations in: (d) The two major types of risk in an electrical installation described by AS/NZS 3000, under Protection against dangers and damage, are Page 8 of 158 TAFE NSW (Training & Education Support, Industry Skills Unit Meadowbank) 2012

2. Factors of Electric Shock The effects of electricity on the human body are complex and to a certain extent are not completely understood. However, the effects on lung and heart function of some measurable factors are known. These factors are: whether the current is d.c. or a.c. the amount of current flow the duration of current flow, and the current path through the body. More complex are the physiological effects, such as: interference to the nervous system and motor functions chemical effects/reactions on the human body; and thermal effects on the human body. All of the above affect the results of an electric shock in causing temporary or permanent damage to the fundamental health of a person. Further information on the effects of electricity on the human body can be found in the IEC Report number 479 written by Professor G. Beigelmeier. Touch Voltage / Touch Current When a person experiences an electric shock, they are first exposed to a touch voltage that results in a touch current. (a) (b) Touch Voltage is defined by AS/NZS 3000 in Clause as: Touch Current is defined by AS/NZS 3000 in Clause as: Current Paths Through the Human Body (c) Typical impedance values for various current paths through the human body are given below. Using these values and a touch voltage of 230 V, calculate the touch current for the each pathway. Hand to Hand: Hand to Foot: Hand to Both Feet: Hand to Seat: Both Hands to Seat: 1000 ohms 1000 ohms 750 ohms 500 ohms 250 ohms Figure 1.1 TAFE NSW (Training & Education Support, Industry Skills Unit Meadowbank) 2012 Page 9 of 158

Pathway Calculation Touch current Hand to hand 1 = V 230 = 230 ma Z 1000 Hand to foot Hand to both feet Hand to seat Both hands to seat Amount of Current As can be seen from the calculated touch current, relatively small amounts of current will flow through the human body in the event of electric shock. These values of current may be fatal! Duration of Current Flow The duration of current through the human body, along with the value of current will determine the severity of the electric shock. Time in Contact with Current Figure 1.2 is a current - duration diagram showing 4 danger zones, each zone having a different influence and damaging effect on the human body. Figure 1.2 - Diagram supplied courtesy of Clipsal Page 10 of 158 TAFE NSW (Training & Education Support, Industry Skills Unit Meadowbank) 2012

Physiological Effects Table provided courtest of Clipsal Zone Physiological Effects 1 Usually no reaction. 2 Usually no harmful physiological effects. 3 Usually no organic damage. Likelihood of muscular contractions and difficulty in breathing. Possibility of cardiac arrest increasing with value of current and time. (d) (e) 4 Including the effects of zone 3. c1 probability of ventricular fibrillation increased to 5%. c2 probability of ventricular fibrillation increased to 50%. c3 probability of ventricular fibrillation increased to above 50%. Further increases in time and/or current are likely to cause arrest and burns. Consider various durations for a touch current of 200 ma. What would be the likely hysiological effect for each of the durations given in the following table? Current Duration Zone Physiological Effect 20 ms 2 Usually no harmful physiological effect. 100 ms 500 ms 1000 ms 2000 ms Curve b is the division between zone 2 and 3. For a touch current of 20 ma, how long would it take for the body to cross the division and enter zone 3 and what would be the impedance of the body when the touch voltage is 230 V? Time = ms Impedance = ohms TAFE NSW (Training & Education Support, Industry Skills Unit Meadowbank) 2012 Page 11 of 158

3. Hazards from Thermal Effects of Current A major effect of electric current is to produce heat in the conductor through which it flows. The quantity of heat produced is given by the equation: H = I 2 Rt Where: H is the heat energy produced in joules. (a) I is the current flowing though the conductor in amperes. R is the resistance of the current path in ohms. t is the duration of current flow in seconds. You will note from the equation that the heat produced is proportional to the current squared. What heat will result if the current in a circuit is doubled? Overload and Fault Current (b) (c) (d) AS/NZS 3000 defines fault current as Clause and overload current as Clause. The Wiring Rules clause Protection against earth fault currents, Clause number requires that conductors or any other parts required to carry a fault current shall be capable of: The Wiring Rules allows for one of two methods to be used for protection against overcurrent. The two permissible methods are: AS/NZS 3000 Clause: (e) Requirements for protection against overcurrent are set out in Section of the Wiring Rules. Page 12 of 158 TAFE NSW (Training & Education Support, Industry Skills Unit Meadowbank) 2012

Heat Sources Protection Against Thermal Effects in Normal Service - AS/NZS 3000 Clause: Protection against the risk of ignition of flammable material in normal service may be provided by: Further information on the thermal effects associated with the installation of electrical equipment is given in Clause:. Electrical Equipment Requiring Protection Against Thermal Effects - AS/NZS 3000 Clause: Heat is developed during the normal operation of electrical equipment. In order to maintain the operating temperature below the rated specified limits, then shall be provided. When the surface temperature of electrical equipment reaches a temperature that may cause a fire hazard to adjacent materials, the electrical equipment will be: Name two items of electrical equipment that would be considered to be a high temperature source: Installation and Connection of Cables Loosening of Connections - AS/NZS 3000 Clause: During normal service, an electrical connection must not loosen due to vibration, alteration of materials or: TAFE NSW (Training & Education Support, Industry Skills Unit Meadowbank) 2012 Page 13 of 158