Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Similar documents
UHI and Thermal Performance of Office Buildings in Bangkok

Available online at ScienceDirect. Procedia Engineering 169 (2016 )

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

Perception of Thermal Comfort for Naturally Ventilated High School Classrooms in San Rafael, CA

Air Movement Preference and Thermal Comfort A survey in classrooms during summer season in Brazil

Assessment of thermal comfort inside primary governmental classrooms in hot-dry climates Part II a case study from Egypt

IMPLEMENTATION OF ANALYTICAL MODELS FOR PASSIVE DOWN-DRAFT EVAPORATIVE COOLING (PDEC) TOWER WITH SPRAY SYSTEMS

Bio Climatic Analysis of Bhubaneswar-An Investigation to Arrive Human Comfort through Natural Ventilation

Energy and indoor temperature consequences of adaptive thermal comfort standards

Analysis of Heat Gain in Computer Laboratory and Excellent Centre by using CLTD/CLF/SCL Method

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

Analysis of Night Ventilation Potential for Residential Buildings in Hot-Humid Climate of Malaysia

Thermal Comfort in Architecture

Thermal comfort and occupant adaptive behaviour in university offices with cooling and free running modes

Thermal Comfort Evaluation of HDB flats

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Effect of insulation ground on anti-condensation in rural residence

Energy impact of ASHRAE s museum climate classes: a simulation study on four museums with different quality of envelopes

A Preliminary Study of Thermal Comfort in Malaysia's Single Storey Terraced Houses

Thermal Comfort Zone for Thai People

COOLING LOAD ESTIMATION OF A ROOM

Using phase change materials to reduce overheating issues in UK residential buildings

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

CAE 331/513 Building Science Fall 2017

Thermal Environment evaluation in Commercial kitchens: Procedure of data collection

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Potential of Indirect Evaporative Passive Cooling with Embedded Tubes in a Humid Tropical Climate Applications in a typical hot humid climate

ADAPTIVE THERMAL COMFORT IN THE WET TROPICS FOR HOUSING DESIGN WITH PASSIVE COOLING

REAL-TIME CONTROL OF OCCUPANTS THERMAL COMFORT IN BUILDINGS. Galway, Ireland

REDEFINING APPROPRIATE THERMAL COMFORT STANDARD FOR NATURALLY VENTILATED BUILDINGS IN TROPICS (SINGAPORE AND INDONESIA PERSPECTIVE)

Thermal environment and thermal comfort in a passive residential building in the severe cold area of China

An Assessment of Thermal Comfort in Hot and Dry Season (A Case Study of 4 Theaters at Bayero University Kano)

Available online at ScienceDirect. Energy Procedia 78 (2015 )

CFD and Wind Tunnel Study of the Performance of a Multi- Directional Wind Tower with Heat Transfer Devices

THERMAL COMFORT IN LECTURE HALLS IN THE TROPICS

Energy saving by ceiling fans

Shifting Comfort Zone for Hot-Humid Environments

Available online at ScienceDirect. Procedia Engineering 145 (2016 ) 18 25

International Transaction Journal of Engineering, Management, & Applied Sciences & Technologies.

International Transaction Journal of Engineering, Management, & Applied Sciences & Technologies.

Chapter 7. Passive Solar Contents

Influence of Building Orientation on the Indoor Climate of Buildings

Experimental investigation on a ceiling capillary radiant heating system

Thermal performance of biofacade with natural ventilation in the tropical climate

THERMAL PERFORMANCE USING RADIANT BARRIER AND PHASE CHANGE MATERIAL IN ROOFS

ScienceDirect. Simulation based mixed mode building design

GREEN CONCEPT OF THERMAL COMFORT DESIGN FOR SUSTAINABLE HOUSING IN THE TROPICS: Learning from Thermal Comfort in School Buildings 1 INTRODUCTION

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Comparison of the Effects of Various Countermeasures on Energy Consumption in a Residential Building

OPENING DESIGN TO IMPROVE THE NATURAL VENTILATION PERFORMANCE OF HIGH-RISE RESIDENTIAL BUILDINGS

Passive cooling effect of building features in traditional Japanese buildings

317: Thermal performance of houses located in Florianópolis, southern Brazil

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Thermal Comfort Survey in Office Buildings in Bandung, Indonesia

Airflow and temperature modelling of sustainable buildings at the design stage can prevent unintended consequences of passive features

PASSIVE SOLAR BUILDING DESIGN STRATEGIES IN LALITPUR, POKHARA AND DHARAN CITIES OF NEPAL

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

Energy simulation of traditional vs. adaptive thermal comfort for two

Thermal comfort under transient seasonal conditions of a bioclimatic building in Greece

Energy Conservation Measure in RDP House in South Africa Overen O. Kelvin, Edson L. Meyer Abstract. Introduction Methodology

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Information paper 17. Prepared by: David Clark. book:

SUSTAINABLE BY PASSIVE ARCHITECTURE, USING COURTYARDS IN NON-DOMESTIC BUILDINGS IN SOUTHEAST QUEENSLAND

Field Investigation of Comfort Temperature and Adaptive Model in Japanese Houses

ScienceDirect. Influence of the balcony glazing construction on thermal comfort of apartments in retrofitted large panel buildings

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Adaptive Thermal Comfort in Warm Dry Climate: Economical dwellings in Mexico

THE ROLE OF ENVIRONMENTAL AND PERSONAL VARIABLES IN INFLUENCING THERMAL COMFORT INDICES USED IN BUILDING SIMULATION. Stephanie Gauthier 1

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Thermal Environment of Chinese Residential Buildings with Different Thermal Insulation Materials in Hot-Summer-and-Cold-Winter Zone of China

Prediction of Thermal Comfort. mech14.weebly.com

Assessment of thermal comfort in shopping centre transitional spaces

Comfort and Weather Analysis Tool

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Simulation and Energy Analysis of Thermal Environment of Unassisted Passive Solar House

Evaluation methods for indoor environmental quality assessment according to EN15251

PREDICTION OF THERMAL SENSATION IN NON-AIR- CONDITIONED BUILDINGS IN WARM CLIMATES

Energy Analysis of Using Thermal Mass in a Hot Humid climate

Numerical Investigation on Ventilation Strategy for Laboratories: A Novel Approach to Control Thermal Comfort Using Cooling Panels

Findings of Field Survey for Thermal Comfort and Ventilation in US Office Buildings

Part 1 Review Questions on material covered in Midterms I & II

A Comparison of Calculated and Subjective Thermal Comfort Sensation in Home and Office Environment

consumption. As the first step of calculating indoor energy consumption, this study investigated the net radiation heat gain of building exterior surf

Thermal Performance Simulation of Residential Building in Tropical Climate Case Study: Housing in Bandar Universiti, Malaysia

Strategy for energy efficient buildings in tropical climate

Bio-climatic Chart for Different Climatic Zones of Northeast India

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

The Influence of Operation Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner

Analysis of indoor temperature in the workshop building during the summer: a pilot study

Impacts of energy retrofits on hygrothermal behavior of Finnish multi-family buildings

Demonstration of Load Shifting and Peak Load Reduction with Control of Building Thermal Mass

buildings ISSN

A Field Study of Thermal Comfort in Open-plan Office Buildings during Transition Seasons in Harbin. Yunsong Han 1, 2, Huixuan Sun 1, 2, Cheng Sun 1, 2

Thermal comfort conditions in outdoor spaces

Energy Consumption Simulation and Analysis of Heat Pump Air Conditioning. System in Wuhan by the BIN Method

POTENTIAL DESIGN PARAMETERS FOR ENHANCING THERMAL COMFORT IN TROPICAL TERRACE HOUSE: A CASE STUDY IN KUALA LUMPUR

Relevant indoor ventilation by windows and apertures in tropical climate: a review study

Comfort Temperatures Inside Low-Cost Housing Case: six warm climate cities in Mexico

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 00 (2017) 000 000 www.elsevier.com/locate/procedia International High- Performance Built Environment Conference A Sustainable Built Environment Conference 2016 Series (SBE16), ihbe 2016 Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand Parinee Srisuwan a,*, Kojima Shoichi a a Department of Civil Engineering and Architecture, Graduate School of Science and Engineering, Saga University, Saga 840-8502, Japan Abstract The highest possession of condominium supply among Bangkok s real estate market tends toward dramatic increase in energy consumption of the building sector. Condominium s entrepreneurs have less concerns on green building evaluation due to the barrier of complication in criteria and the investment in energy efficient technology is generally higher per square meter. From the pilot study on indoor thermal environment of a high-rise condominium in the hot-humid climate of Bangkok, Thailand, during May 9 th to June 8 th, 2015, the highest demanded one bedroom unit was selected. The room conditions during the field measurement were chosen based on the occupancy characteristics towards the use of natural ventilation (NA) and air conditioning system (AC). The results show that by applying natural ventilation during the day while using an air-conditioning system at night is an effective approach for reducing the room s environmental temperature (EnvT). During the daytime with natural ventilation, heat gain and heat loss occur rapidly because the difference between the indoor and the outdoor air temperature is marginal. Dragging EnvT into the comfort zone is possible with an indoor air velocity of 1.5 m/s. In addition, low outdoor air temperature is preferable for natural ventilation since the thermal energy absorbed by internal surfaces increases the cooling load. In a hot-humid climatic region, relative humidity is very high at night. The addition of using air conditioning system at night is likely to provide a comfortable thermal environment. 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the organizing committee ihbe 2016. Keywords: Thermal environment; Field measurement; High-rise condominium; Thermal comfort; Cooling load; Thailand * Corresponding author. Tel.: +81-806-476-4182. E-mail address: pan.parinee@gmail.com 1877-7058 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the organizing committee ihbe 2016.

2 P. Srisuwan, S. Kojima / Procedia Engineering 00 (2017) 000 000 1. Introduction Bangkok, the capital of Thailand, is located between 13º45 North Latitude and 100º35 East Longitude. As in a typical hot-humid climatic region, the air temperature and relative humidity (RH) are high for most of the year. The average mean dry bulb temperature ranges from 28.46 ºC to 30.23 ºC and RH is between 70% and 76%. The wind speed is low with its annual average at 1.0 m/s [1]. Since these weather conditions are mostly outside thermal comfort zone, people usually enhance their comfort by using air conditioning (AC) systems, especially during the hottest months around April and May. The peak demand for electricity had recently beaten the record at 29,403 MW as of April 28, 2016 [2]. The total electricity consumption of the country has been on the rising trend. The industrial sector holds 44% of the total consumption followed by the residential, commercial, small general services, and other sectors (e.g. the non-profit sector and agriculture pumping) account for a share of 23%, 19%, 11%, and 3%, respectively [3]. Meanwhile, the residential sector also holds the largest share of 89% of electricity consumers in Thailand. The expansion of real estate market has led to the increasing in electricity consumption by one-third of the total consumption. Condominiums in Bangkok account for the largest share of 63% of the new supply offered for sales [4], which caused the dramatic increase in energy consumption from using air conditioning systems during the occupancy period. Since the indoor thermal comfort significantly affects the energy usage, thermal environment related to thermal comfort should be determined. In this study, environmental factors in a typical unit of high-rise residential building in Bangkok were investigated through field measurement. The use of an air-conditioning system and windows towards the occupancy characteristic were set during the investigation. The comparative results between thermal comfort and cooling load are also discussed. The significance of the results reported here is limited as the results are based on a specific building configuration and thus, it is difficult to generalise the conclusions. 2. Methodology The location of a selected condominium is in a very high-density residential area of Thonburi, the outer area of Bangkok, and close to the mass transit line. With the price of 93,000 Baht/m 2, it is in the economy to upper-class segment (50,000-99,999 Baht/m 2 ), which has the highest shares in condominium market [4]. The field investigations were performed in 33 m 2 of one bedroom unit on the 19 th floor (27 floors in total) as shown in Fig. 1. It is a corner room facing south west. The living room has two external walls with 50% of opening facing south (1.6 m 2 operable area) and 20% facing west, which receives high radiative heat gain. One semi-external wall faces north and connects to the public corridor. About 40% of the internal wall that separates the living room and the bedroom is a 6 mm single glassing fixed window. The bedroom has one external wall with 60% of opening facing south (1.1 m 2 operable area). Monitoring equipment (Table 1) was installed accordingly to the ASHRAE standard 55 [5], see Fig. 2. For the indoor investigation, an air temperature sensor was set up at 1.1 m above the floor. Humidity, wind speed, and globe temperature sensors were set up at 0.6 m above the floor. Moreover, the surface temperature was also measured by temperature sensors attached on indoor wall surfaces, both in the living room and the bedroom. For the outdoor investigation, HOBO outdoor weather station was set up on the balcony to collect micro-climate data. The investigations were conducted from May to June 2015 as it was the hottest period of the year based on the maximum energy consumption resulted from high level of air conditioning usage. During the 24 hours investigation, the occupancy characteristic was set under 4 cases as follows: Case 1: 24 hours without ventilation, all windows were closed (from May 9 to May 13). Case 2: 24 hours with natural ventilation, all windows were opened (from May 29 to June 2). Case 3: Daytime (6:00 am to 6:00 pm) without ventilation (all windows were closed) and nighttime (6:00 pm to 6:00 am) with an air conditioning system turned on (from June 3 to June 7). Case 4: Daytime with natural ventilation (all windows were opened) and nighttime with an air conditioning system turned on (from May 24 to May 28).

P. Srisuwan, S. Kojima / Procedia Engineering 00 (2017) 000 000 3 Table 1. Monitoring equipment. Parameter Indoor weather station Outdoor weather station Temperature Thermo couple type T with GRAPHTEC GL820 data logger S-THB-M002 Temp & RH sensor with HOBO Humidity T&D TR-72 Ui sensor U30 NRC data logger Wind speed AM-14SD Anemometer S-WSET-A Wind smart sensor set Globe temperature Shibata Globe thermometer - Fig. 1. Floor plan and elevations of the test room. 3. Thermal comfort 3.1. Comfort zone Fig. 2. Installation of monitoring equipment. Thermal comfort correlations [6-8] were used to determine the comfort zone. People feel comfort sensation under neutral temperature as shown in the following equation: T 17.6 0. 31 (1) n T Oav

4 P. Srisuwan, S. Kojima / Procedia Engineering 00 (2017) 000 000 Fig. 3. Average outdoor air temperature and comfort zone where T n is thermal neutralities or neutral temperature (ºC); T Oav denotes the average outdoor air temperature (ºC). The range of comfort temperature is in the range of T n 2. 5. For tropical climate zone, upper RH limit of 80% [9] and lower absolute humidity (AH) limit of 4 g/kg dry air [10] are considered as a comfort environment. This combination effect of temperature and humidity is defined by Gagge, Fobelets, and Berglund as standard effective temperature (SET) [11]. In addition, wind speed also has an effect towards the thermal comfort, which can increase convective heat transfer and evaporative heat loss from human body. The extension of upper temperature limit is given by: T u ( v x) Tn 2. 5 dt( v x) n 2 2.5 6 V 1.6 V e e T (2) where Tu ( v is the extension of upper temperature limit at different wind velocity (ºC); V x) e denotes effective where V e V 0.2 (m/s). This equation is used when indoor wind velocity is less than or equal to 2 m/s, the applicable maximum wind speed for indoor. From the investigations, outdoor air temperature and comfort zone are shown in Fig. 3 and Table 2. The average outdoor air temperatures during the investigation period were mostly outside comfort zone. Since the effect of single-sided ventilation was poor, the outdoor air entered a room with low velocity. The upper limit of comfort range could be extended by only 0.8 ºC under natural ventilation.

P. Srisuwan, S. Kojima / Procedia Engineering 00 (2017) 000 000 5 Table 2. Average outdoor air temperature and comfort zone. Case T Oav Comfort zone T n (ºC) T u (ºC) 1 T l (ºC) 2 T u(v=x) (ºC) 3 Daytime 1 31.95 27.50 30.00 25.00 30.53 (6:00 am to 6:00 pm) 2 32.70 27.74 30.24 25.24 31.05 3 32.41 27.65 30.15 25.15 30.67 4 31.46 27.35 29.85 24.85 30.66 Nighttime 1 1 30.21 26.96 29.46 24.46 29.99 (6:00 pm to 6:00 am) 2 30.01 26.90 29.40 24.40 30.21 3 30.58 27.08 29.58 24.58 30.11 4 29.73 26.82 29.32 24.32 29.84 Table 3. Environmental temperature in living room. 4 Living room Case MRT DBT EnvT Daytime 1 33.33 33.05 33.24 (at 12:00 pm) 2 32.79 32.74 32.77 3 32.27 32.06 32.20 4 32.50 31.67 32.23 Nighttime 1 31.51 31.77 31.60 (at 12:00 am) 2 31.23 31.20 31.22 3 29.85 29.81 29.83 4 29.07 29.08 29.07 Table 4. Environmental temperature in bed room. 4 Bed room Case MRT DBT EnvT Daytime 1 33.24 33.39 33.29 (at 12:00 pm) 2 33.12 33.19 33.14 3 31.88 32.15 31.97 4 32.14 31.99 32.09 Nighttime 1 31.86 31.46 31.73 (at 12:00 am) 2 31.43 31.24 31.36 3 28.35 25.40 27.37 4 27.75 24.82 26.77 1 T u is the upper temperature limit of comfort zone (ºC). 2 T l is the lower temperature limit of comfort zone (ºC). 3 The average indoor velocity was 0.29 m/s without ventilation, and 0.34 m/s under natural ventilation. 4 In case 3 and 4, an air conditioning system was applied; 6:00 pm to 9:00 pm for the living room, and 9:00 pm to 6:00 am for the bedroom.

6 P. Srisuwan, S. Kojima / Procedia Engineering 00 (2017) 000 000 Fig. 4. Environmental temperature during daytime (left) and nighttime (right). 1 In case 3 and 4, an air conditioning system was applied; 6:00 pm to 9:00 pm for the living room, and 9:00 pm to 6:00 am for the bedroom.

P. Srisuwan, S. Kojima / Procedia Engineering 00 (2017) 000 000 7 Fig. 5. Internal surfaces temperature in living room. 3.2. Environmental temperature Similar to air temperature, humidity and wind speed, Mean radiant temperature (MRT) affects the thermal comfort. It is the result of an average internal surface temperature. When MRT is lower than indoor air temperature, radiation is emitted to the surrounding surfaces, which were cooler. In addition, a composite of MRT and indoor air temperature resulted in environmental temperature (EnvT), which is used to describe the heat exchange between the environmental point in a room and the internal surfaces [9]: 2 1 EnvT MRT DBT 3 3 (3) where EnvT is the environmental temperature (ºC), MRT is mean radiant temperature (ºC) and DBT is dry bulb temperature (ºC). Comfort sensation increases when EnvT is lower than the human skin temperature. The results are shown in Table 3, Table 4, and Fig. 4. Since the upper limit of comfort range could be extended by only 0.8 ºC as mentioned in the previously, EnvT of every cases were out of comfort zone but gradually got closer when natural ventilation and air conditioning system were applied. Therefore, the extension of upper limit temperature at the highest wind velocity was predicted. The 24 hours naturally ventilated room in case 2 was cooler than those without ventilation exhibited in case 1. EnvT was reduced and within comfort zone when high indoor air velocity of 1.5 m/s was applied. Similar to case 4, daytime naturally ventilated room (windows were closed during the night), EnvT was closer to comfort zone compared to case 3, daytime without ventilation. Moreover, natural ventilation showed high effectiveness in temperature reduction when it was a naturally ventilated room (case 2). This was because of it lost heat faster than the room without ventilation (case 1). On the other hand, when room s ventilation was mixed with air conditioning system (case 3 and case 4), EnvT during daytime had a small reduction when natural ventilation was applied (case 4). Room air temperature rose up close to outdoor air temperature simultaneously after the window was opened (see Fig. 5). Internal surface temperature gained excessive heat from outdoor air and insufficient convection from low indoor air velocity contributed towards poor cooling load.

8 P. Srisuwan, S. Kojima / Procedia Engineering 00 (2017) 000 000 Table 5. Cooling load from air conditioning processes. Case Cooling load (MJ) Day 1 Day 2 Day 3 Day 4 Day 5 Average Case 3 62,277 63,450 64,786 61,493 57,617 61,925 Case 4 79,064 56,696 75, 241 72,775 64, 273 69,610 4. Cooling load Based on thermal comfort analysis, EnvT at night lay outside comfort zone even though the maximum of applicable indoor air velocity (2 m/s) is applied. Therefore, an air conditioning system is considered for use to provide comfort. On the contrary, there is the possibility to reduce air conditioning energy consumption during the day by applying natural ventilation. In this section, the total heat transfer rate caused by ventilation from the air conditioning system in the living room, as mainly occupied area, is compared between case 3 and case 4. The basic heat transfer rate is given by: q t C Q h (4) t where q t is the total heat transfer rates (W); C t is the air total heat factor, W/(L s) per kj/kg enthalpy; Q is the air volumetric flow rate (L/s); h denotes the air enthalpy difference across process (kj/kg) [12]. The results of cooling load from air conditioning processes (at medium air flow rate of 526 CFM) are shown in Table 5. From Table 5, cooling load of the room using natural ventilation during the day, case 4, was slightly higher than the room without ventilation shown in case 3. For the room that natural ventilation and air conditioning system were applied, internal surfaces gained heat from outdoor air and therefore, the thermal energy stored in internal mass resulted in an increasing of the cooling load. However, other load components must be studied in order to increase the validity. 5. Conclusion In this study, thermal environments in one bedroom unit of high-rise condominium were investigated based on the occupancy characteristics towards the using of natural ventilation and air conditioning system. The results showed that naturally ventilated room with high air velocity (1.5 m/s) could enhance thermal comfort in some hours during the day. But in existing condition, the single-sided ventilation was insufficient for natural ventilation. The average indoor wind speed was only 0.34 m/s. The upper limit of comfort range could be extended by only 0.8 ºC. During nighttime, as in typical hot-humid climatic region, relative humidity was very high. Only 24 hours of natural ventilation might not be able to provide a comfortable thermal environment. In addition, lower temperature of outdoor air was preferred for natural ventilation in order to reduce cooling load due to thermal energy absorbed within the internal surfaces. Therefore, the integrative between passive design strategies with the addition of active system could be an alternative solution in order to reduce energy consumption from using air conditioning system and balance with occupancy thermal comfort. However, this investigation was based on field data from one specific building. Further comparison with simulation data is needed to increase the validity and the understanding of thermal performance in high-rise condominium. References [1] Thailand Meteorological Department, Bangkok s weather data 2004-2013. [2] Thailand Electricity Generating Authority, Net peak generation requirement. Available at <http://www.egat.co.th/ index.php?option=com_ content&view=article&id=348&itemid=116> 2016; [3] Energy Policy and Planning Office, Energy statistics of Thailand 2015, Available at <http://www2.eppo.go.th/info/cd-2015/index.html> 2015;

P. Srisuwan, S. Kojima / Procedia Engineering 00 (2017) 000 000 9 [4] Plus Property Co. Ltd., Plus Property focus half-year research paper: January-June 2015, Available at <http://www.plus.co.th/news-and- Articles/Plus-Property-Focus-Half-year-research-paper--January-June-2015> 2016; [5] American Society of Heating, Refrigerating and Air-conditioning Engineers, ASHRAE standard 55-2013: Thermal environment conditions for human occupancy, Atlanta, 2013, pp. 13-15. [6] M. Humphreys, Outdoor temperatures and comfort indoors, Building Research and Practice 6(2) (1978) 92-105. [7] A. Auliciums, Towards a psycho-physiological model of thermal perception, International Journal of Biometeorology 25(2) (1981) 109-122. [8] A. Auliciems, S.V. Szokolay, Thermal comfort (2 nd ed.). Available at <https://www.researchgate.net/publication/234169993_thermal_ COMFORT> 2007; [9] S.V. Szokolay, Introduction to architectural science: The basis of sustainable design (2 nd ed.), Architectural Press, Massachusetts, 2008. [10] J. Khedari, N. Yamtaipat, N. Pratintong, J. Hirunlabh, Thailand ventilation comfort chart, Energy and Buildings 32(3) (2010) 245-249. [11] A.P. Gagge, A.P. Fobelets, L.G. Berglund, A standard predictive index of human response to the thermal environment, ASHRAE Transac. (1986) 709-731. [12] American Society of Heating, Refrigerating and Air-conditioning Engineers, ASHRAE Handbook: Fundametals, Atlanta, 2013, pp. 17.1-17.6.