Ariol. Clinical IHC and FISH Breast Marker Analysis Quality. Efficiency. Confidence.

Similar documents
Smart digital pathology. Share expertise in real time, not just images

2013 Continuing Compliance Master Series Checklist Updates for Anatomic Pathology. Gerald A. Hoeltge, MD, FCAP July 17,

PATIENT PATHOLOGIST CEREBRO SPECIMEN TRACKING AND WORKFLOW MANAGEMENT. Patient Safety. Productivity. Flexibility.

PATIENT PATHOLOGIST CEREBRO SPECIMEN TRACKING AND WORKFLOW MANAGEMENT. Patient Safety. Productivity. Flexibility.

THE FREEDOM TO DISCOVER BOND RX FULLY AUTOMATED IHC AND ISH AND EMERGING TESTS RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.

Image Analysis. Tools for basic and translational research. visualize analyze interpret report archive customize

GenASIs TM Cytogenetics Suite

CapitalBio LuxScan TM. HT24 High Throughput Microarray Scanner. Exploit the full capacity of your lab

Pathology Solution IVD US. Philips IntelliSite HER2/neu IHC Digital Manual Read

2010 NORTH AMERICAN TISSUE DIAGNOSTICS PRODUCT LINE STRATEGY AWARD

GenASIs TM Cytogenetics Suite

Central Laboratory Services. Anatomic Pathology Histology Services

Laboratory Accreditation Test Validation: A Brave New World for Anatomic Pathology

MAGPIX. Multiplexed Genomic, and Proteomic Biomarker Analysis

MANAGEMENT BRIEF. How Automation is Revolutionizing White Cell Differential Analysis.

Image Analysis in Current Clinical Practice OBJECTIVES. ACCME/Disclosures 4/11/2016. Liron Pantanowitz MD

MetaXpress High-Content Image Acquisition and Analysis Software

Applied Spectral Imaging

SMART DIGITAL PATHOLOGY

The preferred choice of histology and cytology laboratories worldwide

BioView. Karyotype Suite

TECHNOLOGIES & SERVICES FOR THERAPEUTIC ANTIBODY DEVELOPMENT

DIGITAL PATHOLOGY: TECHNOLOGIES AND GLOBAL MARKETS

Risk Mitigation in Breast Predictive Factor Testing. Elizabeth H Hammond MD

MetaXpress High-Content Image Acquisition and Analysis Software

Accelerating the Pace of Understanding

Balancing versatility and value Introducing Optima MR T

AMP-6000 AUTOMATED MICROBIOLOGICAL PLATFORM

Digital Cytopathology & Interactive Case Discussion

Regulatory Challenges and Opportunities for Digital Pathology

Run critical care tests reliably and economically in low-volume settings

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

A legacy of innovation and discovery

ACCURACY THE FIRST TIME. Bring Your Esoteric Assays In-House Routinely SCIEX DIAGNOSTICS MASS SPECTROMETERS

Corning Microplates for Microscopy and High Content Imaging. Improve results with microplates for high resolution cell imaging

Digital pathology: the Swedish project

Providing the speed and quality that laboratories demand

Developing an Accurate and Precise Companion Diagnostic Assay for Targeted Therapies in DLBCL

The worldwide leader in the automation of Immunohistochemistry (IHC), in situ Hybridization (ISH), Fluorescent in situ Hybridization (FISH),

QuantStudio Dx Real-Time PCR Instrument

background digitalization

APPENDIX: TECHNICAL and OPERATIONAL ISSUES of the NEPTUNE. The FDA has not approved the use of WSI for the making primary

BUSINESS PROCESS IN PATHOLOGY

ThermoBrite Elite. Feasibility/Time Savings Study. Blood/Bone Marrow Protocol

TISSUE MICROARRAY (TMA)

Connected. The Integrated Lab. The fully integrated autoimmune laboratory.

Integrated Radiology & Pathology Diagnostic Services: The Time is Now at UCLA

Boost turnaround time for faster diagnosis

GO BEYOND THE LIMITS OF LIMS. TrakCare Lab Enterprise

Session: Innovative Technologies

TOTAL TISSUE DIAGNOSTICS PATHOS DELTA. World s first hybrid tissue processor (microwave + conventional) A fully automatic system to fit your workflow

CS Automated haemostasis testing. Medium workload high class.

Thermo Scientific ARM Automation Platform

Make the move to automated embedding

GE Healthcare. MAC 600 Resting ECG Connecting hearts and minds

TANGO. ANALYSIS TO GO. Innovation with Integrity. The next generation FT-NIR spectrometer. FT-NIR

Getting the most out of going digital: Top 5 tips for digital pathology implementation success

Interlab G26. Fully Automated Agarose Gel Electrophoresis with Positive Sample Identification from Primary Tube

GETTING THE MOST OUT OF BARCODING IN YOUR PATHOLOGY LABORATORY LORETTA SAYLES HT(ASCP) SAYLES LAB CONSULTING

WORKFLOW WITHOUT THE WORK

Inoculation efficiency is the first step in the bacteriology testing process and is the first opportunity for automation.

Accelerating the Adoption of Companion Diagnostics

Molecular Diagnosis Challenges & Solutions. Using Molecular Kits or Laboratory Developed Tests (Home Brew), Emphasis on Validation

THE ESSENTIAL ELEMENT of a

LiquidBiopsy LIQUIDBIOPSY. Automated Rare Template Isolation Platform

Completing the performance picture.

IsoFluxTM. System. The next generation of CTC Analysis is here

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Notice of Faculty Disclosure

The next generation FT-NIR spectrometer. Innovation with Integrity FT-NIR

Thermo Scientific ArrayScan XTI High Content Analysis Reader. revolutionizing cell biology with the power of high content

The New Computer Assisted Stereology Toolbox

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Discovery NM630 Innovation to expand your care.

Rhombix TM. Series Protein Crystallization Solutions. More insight and less mystery in crystallization. Analyze Detect Measure Control

GE Healthcare. The new MAC * 800

IQFISH on Dako Omnis. Panel for Lung Cancer. Dako FAST RESULTS. ALK, ROS1, RET and MET IQFISH. Dako Omnis. Agilent Pathology Solutions

227 AP and >100 CDx engagements

Where your nuclear medicine future begins. Brivo NM615

Survey of Neural Networks in Digital Pathology and Pathology Workflow

Innovative. Intelligent. Intuitive.

Rapid Capture System Proven Performance

Streamline Pre-Analytic Orchard Pathology Processes

Automation In Life Sciences and Diagnostics Applications

Lead the way. Molecular Imaging. GE Healthcare. imagination at work

WORKFLOW WITHOUT THE WORK. Power Express Clinical Automation Solution

GENESIS Edition Transforming CT

STTARR Image Analysis Core Facility UHN Pathology Validation Core

CO 2. and fiber laser product range. Laser Marking Solutions

Press Presse Press Presse

Carl Zeiss MicroImaging AIS. Digital Pathology The Future. Andrew Lesniak Director, Product Management

Digital pathology: the UMC Utrecht experience

Colorectal Cervix Breast

INDUSTRY APPLICATIONS. Cognex delivers unmatched accuracy and ease of use in Vision Guided Robotics applications. Vision Guided Robotics

CytoVision. The platform for every cytogenetics lab. Living up to Life

Changing your idea of clinical performance. Philips HD15 PureWave ultrasound system

BR-9516B. SNP genotyping analysis for medium to ultra-high throughput. GENOMELAB TM SNPSTREAM GENOTYPING SERIES

Paul Valenstein, MD Synopsis. Whole Slide Imaging: Regulation and Validation

Streamline workflow for higher productivity and patient throughput. DirectView. Classic CR System

Transcription:

Ariol Clinical IHC and FISH Breast Marker Analysis Quality. Efficiency. Confidence.

3 Behind every breast slide in your laboratory is a woman waiting for life changing answers With over 1.25 million women diagnosed with breast cancer each year *, accurate interpretation of tissue-based tests ensure that vital treatments can be started sooner. Ariol is a complete microscope-based, epathology platform, bringing quality, efficiency and confidence to breast IHC and FISH analysis so that patients receive optimal care. QUALITY Provide quantitative, objective analysis EFFICIENCY Deliver accurate answers sooner CONFIDENCE Proven clinically validated system SCAN MANAGE ANALYZE Capture precise whole slide or region of interest scans of breast IHC and FISH samples with greater levels of specimen detail as the starting point for accurate analysis and patient diagnosis. Easily and consistently create crisp, highresolution eslides for analysis and archiving without fading or slide degradation. Enhance your productivity and throughput with barcode driven sample identification and casebased workflows. Incorporate patient case information, slides and results in a central database for ease of access and review. Readily generate reports with case information, images and analysis data. Bring precision analysis of biomarkers into routine breast pathology assessment. Having quantitative IHC expression information and FISH counts available while interpreting slides is a valuable way to aid visual observations and help standardize results. * GLOBOCAN 2008, Cancer Incidence and Mortality Worldwide in 2008. Accessed at http://globocan.iarc.fr/factsheet.asp 24/09/2012

4 Quality A world leader in microscopy, histology and optimizing laboratory processes, Leica Biosystems provides the Ariol system as a complete, integrated epathology solution for today s breast pathologist. With consistent and precise interpretation of breast proteins (ER, PR and HER2) and gene expression (HER2/neu), the Ariol system provides high-quality analysis to pathologists aiding diagnosis and helping patients receive the best possible treatment. CONTROL AND OPTIMIZE FISH WITHOUT FADE CLINICALLY VALIDATED Flexible algorithm configuration for your laboratory. Ariol s trainable analytics can be optimized against control slides to accommodate for batch variation and different laboratories tissue staining processes, ensuring accurate analysis results for your slides. Don t risk sample deterioration. HER2 FISH analysis is widely used in many regions and is often considered the gold standard for HER2 assessment. However, FISH signals fade over time and with multiple reviews. Capture a permanent record of the FISH image, including z-stack and analysis data. Automated image analysis removes inter- and intra-reviewer variation, delivering standardization and consistency to clinical breast marker interpretation. For US-based laboratories, maximize return on investment with CPT reimbursement on breast IHC and FISH analysis.

7 Efficiency Satisfy increasing laboratory demands by improving efficiency, increasing throughput and delivering high-quality analysis data sooner. Ariol enables streamlined, barcode-driven workflows eliminating bottlenecks and errors caused by duplicate data entry. The batch scanning and analysis capabilities mean the system can function 24/7. CONTINUOUS PROCESSING MULTIFUNCTIONAL SOLUTION IMPROVED WORKFLOW Keep your laboratory working even after your employees go home. A high throughput system, the Ariol with optional SL200 autoloader increases slide capacity, enabling unattended slide scanning and FISH probe counting. User-defined scanning and analysis protocols enable batch processing, reducing the need for manual intervention, increasing system efficiency. When laboratory space and funding are limited, Ariol combines brightfield IHC (ER/PR and HER2) and FISH (HER2/neu) on a single, compact and affordable system. Choose from brightfield, fluorescence or a combination of both to reflect the tests in your laboratory and maximize usage of your system. Working in a dark room for FISH counting can be tiring and unpleasant work. Bring FISH into the light, improve employee working conditions and count more cells faster, with the Ariol scanning and analysis system. Easily compare serial sections of IHC and FISH staining side-by-side on one screen for improved insight into expression location. 24/7ANALYZE MORE SLIDES IN LESS TIME

9 Confidence Ensure that the right patient gets the right diagnosis. With reports suggesting that up to 20% of HER2 testing may be inaccurate*, many patients may not receive the correct treatment. Ariol provides quantitative, objective analysis of HER2, ER and PR IHC staining, as well as HER2/neu FISH, aiding in the diagnostic decision process so that the patients correct treatment can start sooner. REPRODUCIBLE ACCURATE SECURE Increase confidence in your analysis. For pathologists routinely assessing common breast cancer markers, there is a constant drive towards standardization and reproducibility. Analysis with Ariol gives the confidence of objective analysis and reproducible results in breast pathology. Accurate interpretation of breast protein and gene expression is essential for correct patient diagnosis. With the Ariol system, extract quantitative data from slides and for ease of use, express in leading scoring protocols such as HER2 0, 1+, 2+, 3+ or FISH probe ratios. Ensure only the correct people have access to patient sensitive information. Administrator-defined user accounts control system access and processes, so that only approved personnel can view data, giving peace of mind to you and security to your system. * American Society of Clinical Oncology/College of American Pathologists Guideline Recommendations for Human Epidermal Growth Factor Receptor 2 Testing in Breast Cancer. VOLUME 25, NUMBER 1, JANUARY 1 2007. JOURNAL OF CLINICAL ONCOLOGY, ASCO SPECIAL ARTICLE.

System Advantages Quality Confidence Efficiency Precise Control Carefully optimised calibration routines ensure robust, repeatable performance every day. Complete System One world leading manufacturer for the DM6000 and Ariol software means reliability and total control. High throughput The optional SL200 gives a continuous workflow to allow streamlining of slide capture and analysis. Leica Optical Engineering Ensure the best image quality by utilizing Leica s unrivalled DM6000 B microscope with advanced automation and superb clarity of capture. Proven Analysis Behind every Ariol system is a decade of development and learning in breast pathology analytics. One System, Two Applications With a small footprint and versatile application suite Ariol can seamlessly cope with Fluorescent and Brightfield slides maximizing lab space and minimizing budget.

11 Technical Specifications Clinical image analysis (USA and Europe) Brightfield Fluorescence Brightfield And Fluorescence HER2 IHC ER IHC PR IHC HER2 FISH HER2 IHC ER IHC PR IHC HER2 FISH Objective lens Leica HCX PL PL 1,25x/0.04 Leica HCX PL FL 5x/0.15 Leica HCX PL PL 10x/0.30 Leica HC PLAN APO 20x/0.70 Leica HCX PL APO 40x/0.85 CORR Leica HCX PL APO 63x/1.40-0.60 (optional) Slide capacity 4 or 8 with stage 200 with SL200 Light source Halogen Lamp 12V 100w X-Cite 120 PC including light guide Halogen Lamp 12V 100w (brightfield) X-Cite 120 PC including light guide (fluorescence) Camera Jai CVM 2 (1600 x 1200) Jai CVM 4 (1380x1030) Resolution 20x = 0.368 um/pix 40x = 0.184 um/pix Slide Processing Speed (scanning plus analysis*) Glass slide dimensions Z-stacking Barcode reader Storage Image formats Operating Voltage Mains frequency 20x magnification, 15x15 = 10min 40x magnification, 3x ROI = 15min (approximate for 3 channel FISH slide) 26 x 76 mm (thickness 0.9 to 1.2 mm including coverglass) user selectable number of layers user selectable layer thickness 1 to 30 layers Barcode Scanner, LS2208 1D, supports most 1D Industry standards e.g. Code 128, Interleaved 2 of 5 & Code 2TB RAID 5 array External user-provided network storage Ariol SCN TIFF JPEG JPEG2000 BMP 110 to 220 V (UPS included as standard) 50-60 Hz Multi-channel Ariol Multi-channel SCN TIFF JPEG JPEG2000 BMP Ariol & Multi-channel Ariol SCN & Multi-channel SCN TIFF JPEG JPEG2000 BMP 4 or 8 Slide Capacity With SL200 Dimensions L34 x D59x H68 cm L68 x D59x H68 cm Weight 26.2 KG 57.5 KG Optional Research Software Modules Rare Event Analysis (CTC, Cytospins, Lymph node analysis) Tissue Microarray Analysis Angiogenesis / Microvessel detection

www.leicabiosystems.com Aperio epathology Solutions Leica Biosystems provides excellence in tissue preparation and staining through to epathology and analysis, all of which is backed by unrivalled service, support and expertise. Tissue preparation instruments and consumables Microtomes, blades and slides Leica SCN400 F combined Brightfield and Fluorescence whole slide scanning Aperio epathology management with eslide Manager Secure NETWORK for real-time eslide viewing and collaboration, globally Precision Image Analysis for whole-slide automated research Tissue Microarray workflows through OpTMA SlidePath Gateway and epathviewer for ipad/iphone and Client Expert Service and Support LEICA biosystems Leica Biosystems is a global leader in laboratory workflow solutions for anatomic pathology, striving to advance cancer diagnostics to improve patients lives. Recognizing there is a shortage of pathology expertise worldwide, as well as increasing subspecialization, Leica Biosystems expanded its capability in pathology imaging with Aperio epathology Solutions enabling greater access for pathologists through market leading whole slide scanners, Network solutions that enables remote, real-time viewing and easy distribution of images for collaboration and Precision solutions that provide pathologists with easy-to-use quantitative image analysis to improve clinical and research productivity, reproducibility and consistency. Leica Biosystems brings together products, quality and support. Offering a complete solution that helps you advance workflows, enhance diagnostic clarity and deliver what really matters better patient care. Leica Biosystems an international company with a strong network of worldwide customer services. North America Sales and Customer Support North America 800 248 0123 Asia/Pacific Sales and Customer Support Australia 1800 625 286 China +85 2 2564 6699 Japan +81 3 5421 2804 South Korea +82 2 514 65 43 New Zealand 0800 400 589 Singapore +65 6779 7823 Europe Sales and Customer Support For detailed contact information about European sales offices or distributors please visit our website: www.leicabiosystems.com The Ariol* Microsight, Hersight, ERsight, PRsight and PathVysion digital scoring applications are for in vitro diagnostic use, all diagnostic decisions are made by the qualified clinician. All other assays are for research only, not for use in diagnostic procedures. *Reg. US Pat & TM Off and in other jurisdictions throughout the world 06MKT1008.A0 95.11709 Rev B 6/2013 Copyright by Leica Biosystems 2013, Richmond, IL, USA. Subject to modifications. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH.