Buckling Experiments on Hollow Flange Beams with Web Stiffeners

Similar documents
Finite Element Analysis of Hollow Flange Beams with Web Stiffeners

Section Moment Capacity Tests of Rivet-Fastened Rectangular Hollow Flange Channel Beams

Angle Cleat Base Connections

Shear tests of hollow flange channel beams with stiffened web openings

Increasing the Strength and Stiffness of Coldformed

Pull-Through Failure Tests of Thin Steel Roof Battens under Wind Uplift Loads

Experimental Study on Flexural Behaviour of Cold formed Hollow Flanged Z Sections

Experiments on Stainless Steel Hollow Sections Part 2: Member Behaviour of Columns and Beams

Direct Strength Design of Cold-formed C-sections in Combined Bending and Shear

Refined Plastic Hinge Analysis of Steel Frame Structures Comprising Non-Compact Sections II: Verification

The 2008 AISI Cold-formed Steel Design Manual

New approach to improving distortional strength of intermediate length thin-walled open section columns

EXPERIMENTAL TESTING OF ARCHES WITH RECTANGULAR HOLLOW SECTIONS

Longwave Buckling of Cold-formed Steel Studs Using Direct Strength

Testing and Evaluation of CFS L-headers

Self-drilling Screwed Knee-joints for Cold-formed Steel Portal Frames in Cyclonic Regions

Load-carrying Capacity Estimation on Coldformed Thin-walled Steel Columns with Built-up Box Section

Finite Element Analysis of Failure Modes for Cellular Steel Beams

Novel Cold-formed Steel Elements for Seismic Applications

Simple Complex Simple Complex

PLASTIC DESIGN OF STAINLESS STEEL STRUCTURES

DIN EN : (E)

Improvements to the Fire Performance of Light Gauge Steel Floor Systems

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

On Design of Profiled Sheets with Varying Cross Sections

BEAMS, PURLINS AND BRACING. 5.1 General The design of beams for strength is usually governed by one of the following limit states:

Experimental Investigation of Cold-formed Steel Beam-column Sub-frames: Pilot Study

Thermal Performance of Plasterboard Lined Steel Stud Walls

Pallet Racking Using Cold-reduced Steel

Composite Beams of Cold Formed Steel Section and Concrete Slab

Structural Detailing of Openings in Sandwich Panels

Question Paper Code : 11410

Structural Performance of Bolted Moment Connections among Single Cold-Formed Channel Sections

under Buckling Behavior

The 2013 AISI Cold-Formed Steel Design Manual

Performance of Deep Leg L-headers

Local and Distortional Buckling of Cold-formed Steel Studs

STUDY ON THE EFFECT OF SPACERS ON THE ULTIMATE CAPACITY OF INTERMEDIATE LENGTH THIN WALLED SECTION UNDER COMPRESSION *

FLEXURAL BEHAVIOUR OF STIFFENED MODIFIED COLD-FORMED STEEL SECTIONS EXPERIMENTAL STUDY

BEHAVIOUR OF COLD-FORMED Z-SHAPED STEEL PURLIN IN FIRE

Pull-through Failures of Crest-fixed Steel Claddings Initiated by Transverse Splitting

CEILING DIAPHRAGM ACTIONS IN COLD FORMED STEEL- FRAMED DOMESTIC STRUCTURES

Mechanical behavior and design method of weld-free steel structure with knee brace damper using square tube column

Numerical approach to the lateral buckling of steel tied-arch bridges

Behavior of curved in plan hollow tubular flange beams with corrugated webs using experimental work

Optimum Design of Cold-formed Steel Z-shape Purlins Using a Genetic Algorithm

PORTAL FRAMES 1.0 INTRODUCTION

(a) Pin-Pin P cr = (b) Fixed-Fixed P cr = (d) Fixed-Pin P cr =

Some Improvements to the Design of Sandwich Panels Subject to Local Buckling Effects

7 LOCAL BUCKLING OF STEEL CLASS 4 SECTION BEAMS

Flexural Behaviour and Design of Coldformed Steel Beams with Rectangular Hollow Flanges

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

Modeling stiffener distortion in orthotropic bridge decks with FEM using superelements

Design of Beam-Columns

Effective Width Method Based Design for Distortional Buckling

The Effects of Perforation Length on the Behaviour of Perforated Elements in Compression

Interactive Analysis and Design of Cold-formed Steel Cladding System

NODIA AND COMPANY. GATE SOLVED PAPER Civil Engineering Design of Steel Structure. Copyright By NODIA & COMPANY

Investigation of Slenderness Ratio for Cold-Formed C-Section

Structural Steel and Timber Design SAB3233. Topic 8 Columns Design. Prof Dr Shahrin Mohammad

Overview of the Standard for Seismic Design of Cold-formed Steel Structural Systems - Special Bolted Moment Frames

Direct Strength Design of Cold-formed C-sections for Shear

Behavior of Continuous Span Purlin Systems

BUCKLING OF STEEL AND COMPOSITE STEEL AND CONCRETE COLUMNS IN CASE OF FIRE

The Local Web Buckling Strength of Stiffened Coped Steel I-Beams

FULL SCALE TESTS ON BOLTED CONNECTIONS Tests on beam-to-beam end-plate connections under bending

Effect of U-Turn in Reinforced Concrete Dog-Legged Stair Slabs


Columns under Loads of Varying Eccentricity

2 LATERAL TORSIONAL-BUCKLING OF CLASS 4 STEEL PLATE GIRDERS UNDER FIRE CONDITIONS: EXPERIMENTAL AND NUMERICAL COMPARISON

Scale testing of profiled stainless steel blast walls

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE)

FE MODELLING OF SLENDER CONCRETE-FILLED STAINLESS STEEL TUBULAR COLUMNS UNDER AXIAL COMPRESSION

Flexural Wrinkling Strength of Lightly Profiled. Sandwich Panels with Transverse Joints in the Foam Core

Experimental Study on Post Buckling Behaviour of Steel Plate Girder

Load capacity of slender reinforced concrete walls governed by flexural cracking strength of concrete

Structural performance of steel portal frame buildings subjected to fire

PERFORMANCE OF AN INNOVATIVE PRE-CAST COLD-FORMED STEEL AS COMPOSITE BEAM WITH SINGLE AND DOUBLE C- CHANNELS

Finite Element Analysis of Floor Deck Using Cold Formed Steel

STRENGTH OF PLATES OF RECTANGULAR INDUSTRIAL DUCTS

The University of Sydney School of Civil Engineering Centre for Advanced Structural Engineering NSW 2006 Australia. SupaPurlin

DISTORTIONAL BUCKLING BEHAVIOUR OF FIRE EXPOSED COLD-FORMED STEEL COLUMNS

Analysis and Design of Steel

Buckling Analysis of Cold Formed Steel Compression Members at Elevated Temperatures

Behaviour of Concrete Filled Rectangular Steel Tube Column

Tekla Structural Designer 2016

The influence of pallets on the behaviour and design of drivein steel storage racks - Part I Behaviour

Strength and Ductility of Steel Cold-Formed Section Beam to Column Bolted Connections

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

The Effect of Web Corrugation in Cold-Formed Steel Beam with Trapezoidally Corrugated Web

Behaviour of single storey frames with tapered web members accounting for manufacturing and assembling imperfections

Field and Laboratory Performance of FRP Bridge Panels

Behaviour of Cold-Formed Steel Built-up I Section Under Bending

RESILIENT INFRASTRUCTURE June 1 4, 2016

The Behaviour of Beam-Column Elements with Variable I Cross-Sections considering Lateral Restraints

Half through bridges No. 1.10

Design of Laterally Unrestrained Beams

Cold-formed Steel Special Bolted Moment Frames Capacity Design Requirements

STUDY OF CASTELLATED BEAM USING STIFFENERS: A REVIEW

FULL SCALE TESTS ON BOLTED BEAM-TO-BEAM END-PLATE

Transcription:

Missouri University of Science and Technology Scholars' Mine International Specialty Conference on Cold- Formed Steel Structures (1996) - 13th International Specialty Conference on Cold-Formed Steel Structures Oct 17th Buckling xperiments on Hollow Flange Beams with Web Stiffeners Mahen Mahendran P. Avery Follow this and additional works at: http://scholarsmine.mst.edu/isccss Part of the Structural ngineering Commons Recommended Citation Mahendran, Mahen and Avery, P., "Buckling xperiments on Hollow Flange Beams with Web Stiffeners" (1996). International Specialty Conference on Cold-Formed Steel Structures. 1. http://scholarsmine.mst.edu/isccss/13iccfss/13iccfss-session3/1 This Article - Conference proceedings is brought to you for free and open access by Scholars' Mine. It has been accepted for inclusion in International Specialty Conference on Cold-Formed Steel Structures by an authorized administrator of Scholars' Mine. This work is protected by U. S. Copyright Law. Unauthorized use including reproduction for redistribution requires the permission of the copyright holder. For more information, please contact scholarsmine@mst.edu.

Thirteenth International Specialty Conference on Cold-Formed Steel Structures St. Louis, Missouri U.S.A., October 17e18, 1996 BUCKLING XPRIMNTS ON HOLLOW FLANG BAMS WITH WB STIFFNRS by M. Mahendran and P. Avery* Summary A new cold-formed and resistance welded section known as the Hollow Flange Beam (HFB) has been developed recently in Australia. In contrast to the common lateral torsional buckling mode ofi-beams, this unique section comprising two stiff triangular flanges and a slender web is susceptible to a lateral distortional buckling mode of failure involving lateral deflection, twist and cross-section change due to web distortion. This lateral distortional buckling behaviour has been shown to cause significant reduction of the available flexural strength of HFBs. An investigation using finite element analyses and large scale experiments was carried out into the use of transverse web plate stiffeners to improve the lateral buckling capacity of HFBs. This paper presents the details of the experimental investigation, the results, and the final stiffener arrangement whereas the details of the finite element analyses are presented in a companion paper at this conference. 1. Introduction In recent years, thin-walled cold-formed high strength steel structural members are being widely used in various applications, including purlins, girts, portal frames and steel framed housing. Although cold-formed members have complicated behavioural characteristics, they are often more efficient than conventional hot-rolled steel members. One such member is the new Hollow Flange Beam (HFB) developed by Palmer Tube Mills Pty. Ltd. in December 1993 (see Figure 1). This product is unique as it is the first cold-formed, hollow flange section to be mass produced anywhere in the world. The HFB is manufactured from a single strip of high strength steel (G450 steel with a minimum guaranteed yield stress of 450 MPa) using electric resistance welding. The structural efficiency of the HFB due to the torsionally rigid closed triangular flanges combined with economical fabrication processes was the basis ofhfb development (Dempsey, 1990, 1991). The HFB, dubbed the "dogbone" because of its distinctive shape, was developed primarily for flexural applications (Dempsey, 1990, 1991, 1993, Heldt and Mahendran, 1992). However, research has identified that the flexural capacity of HFB is limited under certain restraint, span and loading conditions by the lateral distortional buckling mode of failure shown in Figure 1 (Dempsey, 1990, 1991, Dunai and Horvath, 1990). * Physical Infrastructure Centre, Queensland University of Technology, Australia 243

244 Figure 1. Lateral Torsional and Lateral Distortional Buckling Modes Unlike the commonly observed lateral torsional buckling of steel beams, the lateral distortional buckling of HFBs is characterised by simultaneous lateral deflection, twist and cross-section change due to web distortion as seen in Figure I. The cross-sectional distortion causes significant strength reductions, and is particularly severe in short to medium spans. Furthermore, because of its unique fabrication process, the HFB is not completely compliant with either the Australian Steel Structures (AS4100) or Cold-formed Steel Structures (ASI538) codes (SA, 1988, 1990). Lateral distortional buckling is not encompassed by the design formulae contained in either of these codes, and an elastic buckling analysis is required to determine its capacity. Therefore an investigation was conducted to study the lateral distortional buckling behaviour of HFBs and to quantify the associated reduction in flexural strength, and to determine ways of eliminating this problem. This investigation concentrated on the use of transverse web plate stiffeners to reduce crosssectional distortion of HFBs and improve their performance using finite element analyses and large scale experiments. It had the objective of economically alleviating the lateral distortional buckling problem of HFB by the use of a suitable type, size, location and number of web stiffeners. For these purposes, the finite element analysis was first used to investigate the effects of a number of parameters on the buckling behaviour of HFBs under a uniform bending moment. The parameters investigated were stiffener type (plate and box-stiffeners), stiffener thickness (5 to 20 mm), location and number of stiffeners (midspan, third or quarter points within a span, both sides or one side only of the web), stiffener welding (welded to flanges only, web only or both), type ofhfb section and span. It was found that stiffening an HFB with 5 mm thick transverse web plate stiffeners at third points of the span could effectively eliminate lateral distortional buckling. Although plate stiffeners welded to the flanges on both sides of web were recommended, the study indicated that plate stiffeners welded to the flanges on only one side of the web may be adequate. In order to validate the results from the finite element analysis, a detailed experimental investigation was carried out on unstiffened and stiffened HFBs under a constant bending moment with a number of web stiffener configurations. This paper presents the details of the experimental investigation, the results, and the final stiffener arrangement. Details of the finite element analysis are presented in a companion paper at this conference (Avery and Mahendran, 1996).

245 2. xperimental Investigation 2.1 xperimental Program Avery and Mahendran (1996) investigated the effect of type, thickness, location and number of web stiffeners on the lateral distortional buckling behaviour of the HFB using finite element analyses (FA) of stiffened and unstiffened HFBs, based on which they made a series of recommendations. The experimental program described in this section was designed such that the recommendations and results from the FA could be verified adequately before using them in the design of HFBs. A total of ten 6 m long HFB specimens were loaded to failure under a constant bending moment within their span of 4.5 m (see Figure 2). The details of each experiment are summarised in Table 1. The measured yield (0.2% proof) and ultimate tensile stresses were 480 and 570 MPa, respectively, for the G450 steel. Load F 0.55 m '/ r 0.55 m Load F 4.5 m Figure 2. xperimental Set-up

246 Table 1. Summary of xperiments xperiment HFB Section 1 45090HFB38 25090HFB28 2 3 4 5 6 7 8 9 10 Number of Stiffeners and Location None 4 - Both sides 2 - One side only 2 - One side only 2 - Alternate sides 2 - Alternate sides 4 - Both sides 2 - Alternate sides 2 - Alternate sides None Stiffener Connection Welded to Flanges and Web Welded to Flanges only Welded to Flanges only Welded to Flanges only Screw-fastened to Flanges only Screw-fastened to Flanges only Screw-fastened to Flanges only Screw-fastened to Flanges only - The FA results indicated that 5 mm transverse web plate stiffeners were adequate as the buckling capacity only increased marginally for thicknesses greater than 5 mm. Similarly, stiffeners at third points of the span were found to be adequate as the additional buckling capacity increase was marginal for spacings closer than one third span. However, stiffeners at midspan alone were found to be insufficient. Other types of stiffeners such as those made of Rectangular Hollow Sections (RHS) were not considered in the experimental investigation as the FA study showed that the capacity increase due to these more expensive RHS stiffeners was only slightly more than that due to web plate stiffeners. Therefore in all the experiments 5 mm transverse web plate stiffeners fabricated from mild (G250) steel plate were used at third points of the span as recommended by Avery and Mahendran (1996). xperiments 1 and 2 were conducted to verify the improvement to the lateral buckling capacity of HFBs with the use of these stiffeners. (a) Stiffener Welded only to Flanges (b) Special Stiffener Screw-fastened to Flanges Figure 3. Transverse Web Plate Stiffeners

247 The buckling results from FA were identical for HFBs with stiffeners welded to their flanges only or both flanges and web. This means that the stiffener welded to the flanges alone is effective in improving the buckling capacity of HFB, and it is unnecessary to weld the stiffeners to the web. The FA study also indicated that it may be sufficient to weld stiffeners on one side only instead of welding on both sides as the difference in buckling capacity was small. Therefore a number of experiments were conducted to verify these predictions (xperiments 2 to 5). Some experiments had stiffeners on both sides of the web at third points of the span (a total of four stiffeners) whereas others had stiffeners which were either on one side only or on alternate sides of the web (a total of two stiffeners). Since the FA predicted no difference between welding to both flanges and web, and welding to flanges only, most experiments (3 to 5 in Table I) had flange welding only. Figure 3 (a) shows a typical transverse web plate stiffener welded to flanges only. Since the finite element study predicted that welding to flanges alone would be sufficient, a special stiffener was developed that could be screw fastened to the flanges. This stiffener was fabricated by cold-bending a 5 mm plate to fit the inclined flanges of HFB and was easily fastened to the flanges using No.14 screw fasteners (see Figure 3 (b)). xperiments 6 to 9 were therefore conducted with these special stiffeners. As seen in Table I, the last experiment (10) was a repeat of xperiment I in order to confirm the reliability of the experimental set-up and method used in this series of experiments. 2.2 xperimental Set-up Two load-controlled hydraulic jacks, located on the overhangs at a distance of 550 mm from each support, were used to produce a constant bending moment over a span of 4500 mm (see Figure 2). Two special loading devices were used to transmit the jack load into the webs of the HFB specimen as shown in Figure 4. This eliminated the load height effects and flange crushing. Figure 4. Load Application

248 To enable direct comparison with the results from the finite element analyses ofhfbs (Avery and Mahendran, 1996) and other theoretical solutions, it was highly desirable that each degree of freedom be either fully fixed or free, ie., no partial restraint. The preferred restraint conditions at the supports were for the cross-section to be restrained from vertical and lateral translation, and prevented from twisting about the longitudinal axis of the member, while being free to rotate about the major and minor axes. These conditions were met by using a specially designed, but relatively simple, support configuration shown in Figure 5. Figure 5. Support Configuration As shown in Figure 5, two mild steel plates were placed between the HFB beam and each roller support. These plates were separated by a stainless steel sheet attached to the top plate and a Teflon layer connected to the bottom plate. A steel pin fixed to the top plate fitted into a hole in the bottom plate. The plates could therefore rotate freely on the low friction Teflon I stainless steel interface, but were prevented from relative translation by the pin. The bottom plate was prevented from lateral translation by the considerable friction force (due to large normal forces) at the interface with the roller. A steel plate was also clamped to the roller to ensure minimum lateral movement of the bottom plate. A Rectangular Hollow Section (RHS) web stiffener was welded to the HFB section and to the top plate over the support (see Figure 5). This stiffener prevented twist at the support, and connected the HFB specimen to the top plate, allowing rotation about the minor axis without lateral deflection. The stiffener also transmitted the reaction force from the web directly to the support, preventing local bearing failure of the bottom flange.

249 Two 5 mm strain gauges located at midspan on the top and bottom fibres of the section were used to verify the bending moment within the span, and two wire displacement transducers attached to the top and bottom fibres at midspan were used to measure lateral deflection (see Figure 2). Conventional displacement transducers were not suitable because large deflections were expected and the direction of buckling was not known. Furthermore, it was necessary to locate the displacement transducers far enough away from the beam to minimise error due to the vertical deflection of the beam. Two conventional displacement transducers, one at midspan to measure vertical deflection, and the second at a support to measure movement of the bottom plate were also used. This was implemented to monitor the performance of the support configuration, and to assess whether the assumed lateral restraint did occur. 2.3 xperimental Procedure ach HFB specimen was prepared with RHS stiffeners on both sides of the web at the supports and intermediate transverse web plate stiffeners as per Table 1. It was placed onto the roller supports and the displacement transducers, strain gauges and special loading devices were set in place. The hydraulic jacks were carefully located and aligned as any eccentric loading would be undesirable. The load was applied incrementally with reducing load steps as the expected failure load was approached. Since the load was applied using load control, particular care was required to accurately determine the ultimate load without catastrophic failure. During the loading of specimen, deflection and strain readings were taken and the failure mode carefully observed. The magnitude of the applied constant bending moment within the span of the HFB specimen was obtained by multiplying the jack load by the distance of jack from the support of 550 mm. This value was compared with the bending moment calculated using the measured midspan strains (average of top and bottom flange strains x Young's modulus of 200,000 MPa x section modulus Z of HFB section). The agreement was within 5% in most cases and thus for consistency only the former value of applied bending moment was used in all the moment versus lateral deflection curves shown in the next section. These curves were used to evaluate and compare the performance of the HFBs. These results are presented in the next section and discussed. 3. xperimental Results and Discussion All the experiments showed that HFBs have very little post-buckling strength beyond lateral buckling. This confirms the results from the finite element analysis of HFBs (Avery and Mahendran, 1996). For some experiments, attempts were made to determine the buckling moment from the moment versus lateral deflection curve using the fourth power method (Takabatake, 1988). For example, the buckling moment of unstiffened 300 90HFB28 (xperiment 1) was estimated to be 42.6 knm compared with the ultimate moment of 42.9 knm. The corresponding results from the finite element analysis were 43.3 and 44.0 knm. Therefore in the discussion of results in this section, no attempt was made to differentiate between the elastic buckling and ultimate moments. Table 2 presents the ultimate failure moments from the experiments reported in the previous section, and compares with the elastic lateral distortional buckling moments from the finite element analyses. In general, the results agreed quite well, with experimental values often being greater than the analytical values.

250 Table 2. lastic Lateral Distortional Buckling and Ultimate Failure Moments Note: 1. All xperiments except 8 and 9-300 90HFB28 2. The FA buckling moments for 450 90HFB38 and 250 90HFB28 with no stiffeners are 57.1 and 44.5 knm, respectively. 60 50 z ~ ~.. ~ '" i c II III 40 30 20 10 --...-No Stiffeners - xp!. 1 ~Stiffeners Welded Both Sides - xp!. 2...-No Stiffeners - xp!. 10 -_No Stiffeners - FA -Stiffeners Both Sides - FA 0 0 10 20 30 40 50 60 Lamral Deflection at Midspan (mm) Figure 6. Bending Moment versus Lateral Deflection at Midspan Curves for Unstiffened and Stiffened (4 Stiffeners Welded to Flanges and Webs) 300 90HFB28 Beams

251 xperiments with unstiffened HFBs (xperiments I and 10) verified the premature lateral distortional buckling failure of HFBs. The fact that experiments I and 10 were conducted three months apart and still gave the same failure moments confirmed the repeatability and reliability of the experimental results. Figure 6 presents the experimental and non-linear finite element analysis results for two 300 90HFB28 beams: the first unstiffened and the second with stiffeners on both sides (xperiments I, 2 and loin Tables I and 2). The non-linear finite element analysis was able to predict the bending moment versus lateral deflection curve, and ultimate moment capacity quite well. The results in Figure 6 and Table 2 clearly show the improvement of approximately 20% in the lateral buckling capacity of HFB when stiffeners were used on both sides of the web. The capacity of 56.4 knm in xperiment 2 is rather high and may have been due to experimental variation. The use of stiffeners appeared to have eliminated the distortion of the HFB section during its lateral buckling failure. Figure 7 shows the typical lateral buckling failures of unstiffened and stiffened HFBs. (a) Unstiffened HFB (b) Stiffened HFB Figure 7. Typical Lateral Buckling Failures ofhfbs Figure 8 presents the bending moment versus lateral deflection results from xperiments 3 to 5 for which only two stiffeners were used either on the same side of the web or on alternate sides of the web. The FA results for the HFB with stiffeners on the same side of the web are also presented in Figure 8 and compared with experimental results. It is assumed that the FA results for stiffeners on alternate sides of the web will be nearly identical to those for stiffeners on the same side of the web. As seen from the ultimate moment results in Figure 8 and Table 2, welding stiffeners on the same side (xperiment 3 and 4-48.8 and 52.3 knm) appeared to be detrimental compared to welding stiffeners on alternate sides (xperiment 5 63.8 knm). When the stiffeners were welded to the same side of the beam it was found that the welding process introduced an initial bow in the beam in the form of a single half sine

252 wave which was in phase with the expected lateral buckling mode within the span. This had the potential of reducing the ultimate moment capacity of the beams. On the other hand, when the stiffeners were welded to alternate sides of the beam, an initial bow in the form of a continuing sine wave form with two half sine waves was introduced in the beam. This initial bow was not in phase with the expected lateral buckling mode and this could have caused the higher buckling capacity of 63.8 knm. Since the finite element analysis did not include these imperfections due to welding, it could not predict this variation in capacity. For the same reason, the experimental moment versus lateral deflection curves did not agree well with the FA curve. Despite these results, xperiments 3 to 5 gave confidence in the use of only two stiffeners as the experimental capacities (48.8, 52.3 and 63.8 knm) were all considerably higher than that ofunstiffened HFH (42.9 knm) and thus confirmed the FA predictions. 70 60 z c.. C 0 :::;;..... c '6 c IQ 50 40 30 20 10 Stiffeners Welded One Side - xpt. 3 Stiffeners Welded One Side - xpt. 4 --A-Stiffeners Weldlld AM. Sides - xpl. 5 -Stiffeners One Side -!'FA 0 1l--- +----1-~~ +---+ --_+---+ --+-.--.-_ 0 10 20 30 40 50 60 70 80 Lateral Deflection at Midspan (mm) Figure 8. Bending Moment versus Lateral Deflection at Midspan Curves for 300 90HFB28 Beams with 2 Stiffeners Welded to Flanges only Since the previous experiments with stiffeners welded to the flanges only showed that they were equally effective as those welded to both flanges and webs, the special stiffener shown in Figure 3 (b) was used in xperiments 6 to 9. Figure 9 presents the results of these experiments for three different HFB sections. Results were of the same order (57.8 and 55.0 knm) for xperiments 6 and 7 with stiffeners on one side of the web (two stiffeners) and both sides of the web (four stiffeners), respectively. This confirmed that stiffeners on one side of the web were equally effective as stiffeners on both sides of the web for 300 90HFB28 sections. In fact, the experiment with two stiffeners produced a higher ultimate moment than that with four stiffeners. Both experimental results (57.8 and 55.0 knm) appeared to be of the same order as the corresponding results (52.3 and 56.4 knm from experiments 4 and 2) when stiffeners were welded. This implies that screw-fastening the special stiffener to the flanges will be adequate and can eliminate the need for welding the stiffeners to the 300 90HFB28 beams. By comparing Figures 8 and 9 it can be seen that lateral deflections prior to buckling were quite small for HFBs with screw-fastened stiffeners compared to the HFBs with welded

253 stiffeners. This is because the screw-fastening does not introduce any geometrical imperfections or residual stresses compared to welding. This is a significant advantage produced by the screw-fastening method. 80 70 60 z ~ 50 1: II> 0 40 :;;.., c '6 c II> III 30 20 10 Stiffeners All. Sides 300 90HFB28 - xpl. 6 --+--Stiffeners Both Sides 300 90HFB28 - xpl. 7 ---+-Stiffeners All. Sides 450 90HFB38 - xpt. 8 Stiffeners All. Sides 250 90HFB28 - xpl. 9 Stiffeners One Side 300 90HFB28- FA Stiffeners Both Sides 300 90HFB28 - FA 0 0 10 20 30 40 50 60 70 80 Lateral Deflection at Midspan (mm) 90 100 Figure 9. Bending Moment versus Lateral Deflection at Midspan Curves for HFB Sections with 2 New Stiffeners Screw-fastened to Flanges only xperiments 8 and 9 involving other HFB sections, the largest section 450 90HFB38 and one of the smaller sections, 250 90HFB28, also confirmed the analytical predictions and other observations, in particular the adequacy of the new screw-fastened stiffeners. The use of screw-fastened stiffeners improved the buckling moment from 57.1 knm to 68.0 knm for the larger HFB section (19% increase) and 44.5 to 51.0 knm for the smaller section (15% increase). It is to be noted that based on the finite element analysis (Avery and Mahendran, 1996), up to about 50% increase can be expected in the buckling moment of stiffened HFBs for medium spans in the range of 2 to 4 m Since the new stiffeners are simply screw-fastened to the flanges on alternate sides of the beams and improve the buckling capacity in a similar manner to those welded to the flanges, they are recommended rather than welded stiffeners. In xperiments 6 to 9, the new stiffeners were screw fastened to alternate sides of the HFB web. Since they did not introduce any residual stresses or geometric imperfections in the beam as in the case of welding, it is unlikely that screw-fastening to the same side or alternate sides of the web will make any difference to the results. However, the latter method was preferred in all the experiments in this investigation and is recommended. 4. Conclusions A detailed experimental investigation of unstiffened and stiffened HFBs under a constant bending moment was conducted in order to verify the results from a finite element study of

254 the same. Large scale experiments on 4.5 m span HFBs confirmed that HFBs underwent a premature lateral distortional buckling failure, but the web distortion was eliminated and their capacities were significantly improved when transverse web plate stiffeners were used. The experiments verified the analytical based recommendation that 5 mm web plate stiffeners welded to flanges on both sides of the web at third points of the span would be adequate to provide such improvements. Verification of the important outcomes of the finite element study implies that design charts developed using the finite element buckling results for stiffened HFBs (Avery and Mahendran, 1996) can be safely used in design practice. The experimental investigation revealed that welding 5 mm plate stiffeners welded to the flanges on alternate sides of the web was equally adequate. It also led to the development of an 'easy-to-install' special stiffener that is screw-fastened to the flanges on alternate sides of. the web for all the HFB sections. 5. Acknowledgements The authors wish to thank Justin Riley and Daren King who conducted some of the experiments reported here, QUT Structures Laboratory Staff for assisting with the experiments, and Palmer Tube Mills Pty. Ltd. for donating the test materials. 6. References Avery, P. and Mahendran, M. (1996) Finite lement Analysis of Hollow Flange Beamswith Web Stiffeners, Proc. 13th Int. Specialty Coni on Cold-Formed Steel Structures, St. Louis, USA. Dempsey, R.I. (1990), Structural Behaviour and Design of Hollow Flange Beams, Proc. of the Second National Structural ngineering Conference, Institution of ngineers, Australia, Adelaide, October, pp 327-335; Dempsey, R.I. (1991), Hollow Flange Beams: The New Alternative, Technical Presentation, AISC, June. Dempsey, R.I. (1993), Hollow Flange Beam Member Design Manual, Palmer Tube Technology Pty. Ltd., Australia. Dunai, 1. and Horvath, 1. (1990), Ultimate Load Analysis of Beams with Hollow Flanges, Proc. ofint. Conference on the Stability of Steel Structures, Budapest Hungary, pp 387-392. Heldt, T.J. and Mahendran, M. (1992), Distortional Buckling Analysis of Hollow Flange Beams, Research Report No. 92-8, Queensland University of Technology, March. Standards Australia (SA) (1988), Cold Formed Steel Structures, AS1538. Standards Australia (SA) (1990), Steel Structures, AS4100. Takabatake, H. (1988), Lateral Buckling ofi-beams with Web Stiffeners and Batten Plates, International Journal of Solids Structures, Vol. 24 No. 10, pp 1003-1019.