Flow Characterization of a Piezo-Electric High Speed Valve

Similar documents
CHAPTER 6 : GAS SAMPLING SYSTEMS

Study on magnetic separation device for scale removal from feed-water in thermal power plant

FEATURE ARTICLE. The MDLT-1302T Partial-Flow Dilution Tunnel for Transient Test Cycle PM Sampling. Yutaka Yamagishi

Numerical and Experimental Modeling of Producer Gas Carburettor

Pitot Tubes and Industrial DP Transmitters (Optional Exercise)

Solar Flat Plate Thermal Collector

A STUDY ON FLOW BEHAVIOR INSIDE A SIMPLE MODEL OF EJECTOR

Laboratory Testing of Safety Relief Valves

Model 140MX Flowmeter Functional Overview

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

Gilflo ILVA flowmeters for steam, liquids and gases

FLOW PATTERN IN CO 2 -LUBURICANT TWO-PHASE FLOW AT SUPERCRITICAL PRESSURE

Flow Meter Calibration

Problems with Pitots. Issues with flow measurement in stacks.

MEASURMENT OF THE FILM THICKNESS, FILM VELOCITY AND ENTRAINMENT FRACTION IN A LIQUID-AIR ANNULAR FLOW USING A CONDUCTANCE FLOWMETER

RUNYI GROUP. Main Features. STLU Vortex Flow Meter

ISO INTERNATIONAL STANDARD

Gilflo flowmeters. for steam, liquids and gases

Journal of Mechanical Science and Technology 25 (8) (2011) 1961~ DOI /s

Design, Fabrication & CFD Analysis of Multi-Hole Orifice Plate

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

MEASUREMENT OF AIRFLOW

3. EXPERIMENTAL. 3.1 The Designed ESP

flow measurement Methods

Hydrogen Production Characteristics from Ammonia by Plasma Membrane Reactor

Universities of Leeds, Sheffield and York

Flow Conditioning for Irrigation Propeller Meters

Pipe Flow Hydraulics

Lab #3 Conservation Equations and the Hydraulic Jump CEE 331 Fall 2004

Flow Conditioning Why, What, When and Where. Gas Flow Conditioning Why, What, When and Where

VENTURI FLOW METER CALIBRATIONS SERIAL NUMBERS: , , , Prepared for. Imperial Flange and Fitting.

Study on a High-Power Stirling Cryocooler

Profile SFR-52 SWAT JAPAN. Japan Atomic Energy Agency, 4002 Narita, Oarai-machi, Ibaraki, Japan.

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)

CFD Analysis for Production of Carbon Nanotubes

ME 215. Mass and Energy Analysis of Control Volumes CH-6 ÇANKAYA UNIVERSITY. Mechanical Engineering Department. Open Systems-Control Volumes (CV)

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

ASME PTC Flow Measurement

Survey on the Techniques of Flow Measurement

International Journal of Advance Engineering and Research Development

ABB Measurement & Analytics Flowmeter technologies

Performance Testing of A Parabolic Trough Collector Array

Studies on Atmospheric Non-Thermal Plasma Jet Device

I. CHEM. E. SYMPOSIUM SERIES NO. 85 THE SMALL-SCALE RELEASE RATE OF PRESSURISED LIQUEFIED PROPANE TO THE ATMOSPHERE

EXERGY LOSS ANALYSIS OF THE REGENERATOR IN A SOLAR STIRLING ENGINE

Feature Article. Indirect Methods to Calculate the Fuel Consumption. Configuration of the Measuring Instrument

Cavitation Effect to the Hydraulic Piston Pump Flow Pulsation Zhang Huan 1, a

Effect of Injection Pressure and Size of Nozzle Throat of a Cavitating Jet on Cavitation Peening

Solar cell junction temperature measurement of PV module

FLOW REGULATING SYSTEM USING WEIR AND ORIFICE IN A MANHOLE

Experimental study of plasma window 1*

Lab #3 Conservation Equations and the Hydraulic Jump CEE 331 Fall 2003

Fluid Flow Conditioning. August 2015

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

VAPORIZER PRODUCTS. Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U.S.A.

Katsuyuki Edahiro d, Toshihiro Oka d

High-Volume Low-Turbulence Inlet for Aerosol Sampling from Aircraft

EXPERIMENTS WITH THE THERMODYNAMIC METHOD

Design and distribution of air nozzles in the biomass boiler assembly

Experimental Analyses on Parabolic Solar Collector at Various Operating Conditions

Fabrication and Study of the Parameters Affecting the Efficiency of a Bladeless Turbine

Production of High Power and Large-Area Negative Ion Beams for ITER

OSCILLATING HEAT PIPE COUPLED WITH PHASE CHANGE MATERIAL (OHP/PCM) USED FOR BATTERY THERMAL MANAGEMENT

VERIS Accelabar. Superior Flow Measurement Accuracy

Static Mixers. Operation, Installation and Maintenance Instructions. Custom Engineered Solutions. to Meet Your Specific Industry Needs

Electrothermal efficiency, temperature and thermal conductivity of plasma jet in a DC plasma spray torch

GUIDANCE NOTE. Performance of Electromagnetic Meters Designed for Use in Part-Filled Pipes.

f=sr.v/d Thereinto f----fre quency of Karman Vortex shedding Sr----Strouhal number v----velocity d----width of column object

HYDRAULIC DEMONSTRATION CHANNEL

Averaging PITOT Tube 5RD series

Model LMM-H03 Mass Air Flow Sensor

Quenching steels with gas jet arrays

Application Note. Operating Micropumps at Low Flow Rates

Title: Standard Operating Procedure for Measurement of CO in Ambient Air by Gas Filter Correlation (GFC)

Critical Consideration on Wall Thinning Rate by Liquid Droplet Impingement Erosion

Performance Study of Solar Air Heater with Baffled Duct

Hydrogen Release Deflagrations in a Sub-Scale Vehicle Tunnel

Further Development of Low Pressure Drop Duct Burners

measurement sensor and data transmission technology innovation has reduced installation costs, simplified maintenance and enhanced plant performance

Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy

A Study of a New Oil Injection to Compression Chambers on Scroll Compressors

EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET

Performance Characteristics of Low-Power Arcjet Thrusters Using Low-Toxicity Propellants of HAN

Second stage cooling from a Cryomech PT415 cooler at second stage temperatures up to 300 K with cooling on the first-stage from 0 to 250 W

SURFER (the Surfaces Analyzer) Draft product specifications

2.4 CO 2 storage change

Supersonic Nozzle Flow in the Two-Phase Ejector as Water Refrigeration System by Using Waste Heat

Flow and Heat Transfer Characteristics in High Porosity Metal Foams

Experimental development and analysis of a high force/volume extrusion damper

International Journal of Emerging Trends in Science and Technology Optimization of soot blower control

Superposition method for multi rows of a film cooling hole on a turbine stationary vane surface

Slurry Jet Pump Performance: Under Different Design and Operational parameters

Vortex EX DELTA lowmeter Technical Specifications

Tracer Dilution Measurements for Two-Phase Geothermal Production: Comparative Testing and Operating Experience

DISPLACEMENT EFFICIENCY OF WATER IN A CYLINDRICAL TANK

MODELING THERMODYNAMIC ANALYSIS AND SIMULATION OF ORGANIC RANKINE CYCLE USING GEOTHERMAL ENERGY AS HEAT SOURCE

Study on the Characteristic of External Conformal Turbine for Underwater Moving Body Measurement

APPLICATION NOTE: AN-100. Selecting Strain Gages Silicon vs Metal Foil

The Effects of Liquid Properties and Bed Hydrodynamics on the Distribution of Liquid on Solid Fluidized Particles in a Cold-Model Fluidized Bed

Performance of an Air-Assist Nozzle Using Heated Air

Transcription:

Flow Characterization of a Piezo-Electric High Speed Valve T. Takiya*, N. Fukuda*, M. Yaga** and M. Han*** *( Hitachi Zosen Corporation, Osaka 551-0022, Japan) ** (Department of Mechanical Systems Engineering, University of the Ryukyus, Okinawa 903-0213, Japan) *** (Department of Materials Science and Engineering, Nanjing University, Nanjing 210093, China) ABSTRACT Injecting a gas into fusion reactors or semiconductor manufacturing systems, one has to quickly control the flow rate by a piezoelectric valve. In order to construct a gas injection system with high speed valves in the future, performance tests have been conducted on a commercial piezoelectric valve. An orifice flowmeter for measuring time average flowrate and a hot wire anemometer for instantaneous flowrate were manufactured. The total flow coefficient of the orifice flowmeter was obtained experimentally under a low pressure of a 10-2 Pa and a low flowrate of a few mg/s, although they are smaller than the values specified by Japanese Industrial Standards. It is found that the hot wire anemometer installed downstream in the vicinity of the valve is suitable for detecting the change in flowrate with the response time of less than 1 ms. Keywords - Compressible Flow, Flow Rate, Hot Wire Anemometer, Orifice Flowmeter, Piezoelectric Valve, Pipe Flow I. INTRODUCTION In the large helical-flow device of a fusion reactor or the gas supply device of a semiconductor manufacturing facility, it is required that various types of gases be injected into the devices under vacuum and rapidly mixed up to a specified component ratio[1][2][3]. To provide a solution for the requirement, a piezoelectric valve has been generally used to control flowrate of each component of the gas in such devices. However, because of the hysteresis inherent of piezoelectric elements, the valves are not suitable for regulating flowrate by means of ordinary feedback control; PWM (Pulse Width Modulation) control is, therefore, used often as a substitute[4][5]. Before any sort of practical application using a piezoelectric valve with the PWM control, it is necessary to investigate the basic characteristics of a single pulse flow discharged from the valve. Moreover, in order to control flowrate in real-time using a piezoelectric valve, a high speed flowmeter is needed to spontaneously monitor flowrate. Although there is a JIS(Japanese Industrial Standards)-conforming orifice flowmeter as a possibility, the discharged flow from the piezoelectric valve is so infinitely minute that the JIS flowmeter would be unsuitable for the situation. On the other hand, a hot wire anemometer might be a good choice as a flowmeter because of its higher response. But, it has yet to be ascertained whether today's commercially available hot wire anemometers are applicable to flows under vacuum condition. We made prototypes of each an orifice flowmeter and a hot wire anemometer, to measure time-averaged flowrate and instantaneous flowrate respectively, with the ultimate objective of using them as practical sensors in future control systems. We also investigated flowrate characteristics of a commercially available piezoelectric valve using the prototype flowmeters, and verified the applicability of the two prototypes as flowrate monitors. II. EXPERIMENTAL Figure 1 shows a schematic view of the experimental apparatus for measuring the one pulse-averaged flowrate and instantaneous flowrate of a piezoelectric valve. An enlarged drawing of the hot wire anemometer is also indicated in the same figure. The piezoelectric valve is a commercial model, which has a maximum flowrate of 20 l/min in high-purity nitrogen gas equivalent. High voltage is imposed on the piezoelectric valve by a dedicated power driver whose control voltage is supplied from a pulse generator. The entrance of the piezoelectric valve is open to the atmosphere, while the exit is directly connected to a hot wire anemometer of constant temperature type we made by ourselves. The output signal from the controller of the hot wire anemometer is transmitted to a multi-channel data analyzer along with the input signal from the pulse generator. The hot wire anemometer is connected further downstream to a vacuum chamber. The vacuum chamber is a stainless steel tube of 1000 mm in length and 36 mm in inner diameter, and has a port 14 P a g e

located 200 mm upstream from its end flange. The port is connected to a vacuum pump and a vacuum gauge via valve 1 and valve 2, respectively. of the flowmeter is 5.0 mm. In order to measure the pressure difference between the upstream and downstream sides of the orifice, a digital pressure gauge is installed. Another pressure gauge is also embedded to measure pressure upstream of the orifice. (a) hot wire anemometer Fig.2 Schematic Apparatus for Measuring Flow Rates with the Provided Orifice Flowmeter III. RESULTS AND DISCUSSION Experimental results obtained by using the above mentioned setup are discussed in section Ⅲ. The threshold voltage to operate the piezoelectric valve, the critical pulse width to completely open and flow gas through the valve, the total flow coefficient to be modified for our experimental conditions and the validity of the prototype of hot-wire anemometer are explored with experimental data in the following sections. (b) measuring system for the piezo-valve performance Fig.1 Schematic of Apparatus for Measuring Flow Rates Resulted from the Pulsation of the Piezoelectric valve Figure 2 shows a schematic view of the experimental setup used to measure the time-average flowrate of the piezoelectric valve. In this setup, the exit of the valve is connected to a vacuum chamber in which an orifice flowmeter with D D/2 tap is installed at a distance downstream of the piezoelectric valve. The vacuum chamber is shaped like a tube 1600 mm long and 70.0 mm in diameter, while the orifice diameter Ⅲ-1 Basic Characteristics of the Piezoelectric Valve Figure 3 shows the typical static flow characteristics of a piezoelectric element. Because of the hysteresis inherent to the elements, the relationship of the valve aperture to the applied voltage is generally not unique. 15 P a g e

Fig.3 Variation in Mass Flow Rate against Control Voltage (a) dependence of pulse width (pulse period: 55ms) pulse width and the pulse period on the threshold voltage E th (control voltage) by using the hot wire anemometer, as shown in Fig.4, we found that E th decreased as pulse width increased in the case of a constant period, as was the case with the control voltage in Fig. 4(a). On the other hand, with a constant pulse width, threshold voltage E th increased as the period became longer in Fig. 4(b). In order to come up with a piezoelectric valve for PWM control, the next step is to learn the flowrate feature for a single pulse operation. The vacuum chamber was initially depressurized to an order of 10-2 Pa and then pressure in the chamber was gradually raised as the piezoelectric valve was operated by single pulsedriving. The relationship between pressurization rate Δp/Δt and mass flowrate Q is expressed with the following equation, V p Q (1) RT t Here, V is the volume of the vacuum chamber, R the gas constant of air and T the air temperature. Figure 5 shows the flowrate, which is converted from the pressure increase detected by a Pirani gauge when pressure equilibrium was reached, against the pulse width of the pulse generator. The flowrate is actually calculated from the average pressure increase which is obtained from a 10 times pulse discharge. The variable Δt means the pulse width, so the flowrate shown here is given as the time averaged flowrate for one pulse discharging. From the Fig.5, it can be understood that the mass flowrate increases as the voltage applied to the piezoelectric valve increases under a constant pulse width. When the pulse width was varied under the condition of a constant control voltage, the mass flowrate increased as pulse width became longer in the range of more than 20 ms. It is also found that the mass flowrate becomes nearly constant above the pulse width of 70ms in case of the control voltage of 2.5 V. (b) dependence of pulse period (pulse width: 25ms) Fig.4 Pulse width and period dependence on the threshold voltage of the piezoelectric valve For a piezoelectric valve, there is a minimal voltage required to actually operate the valve, that is, a threshold voltage. Measuring the dependence of the 16 P a g e

C 4 1 (3) Fig.5 Mass flow rates of air versus pulse width of control voltage This fact would suggest that it takes some little time occupied to obtain the expected valve aperture corresponding to a given applied voltage. And also, when even the control voltage is more than 3.0 V, the graph shows a tendency that flowrate reaches at a constant value for a certain pulse width. From these facts, it can be proved that the critical pulse width which makes flowrate constant depends on the control voltage and that the higher the control voltage is, the longer the critical pulse width is. We further learned that the flowrate is almost zero, regardless of the control voltage, when the pulse width of the control voltage is shorter than 20 ms. This is attributed to the fact that the variations in flowrate of the gas discharged from the valve are too small to detect the pressure by the Pirani gauge. Where β is the ratio d/d, in which d is the orifice diameter and D is the tube inner diameter. In the standard, JIS Z9762, both the coefficients C and ε are defined in detail as the function of β, and an application range of the orifice diameter and Reynolds number are also specified. From the viewpoint of the application ranges, the manufactured flowmeter is no adopted for the standard. Also, if we compute the compensation coefficient by the equation provided by JIS using the experimental data obtained here, we find it would be between 0.98122 and 0.99855. However, being calculated by substituting the experimental data into Eq. (2), the actual total flow coefficient is considerably lower than these values. So it is plausible that the actual phenomena are greatly affected by gas compressibility because of reduced orifice diameter. Figure 6 shows the relationship between the actual total flow coefficient and the pulse width using pulse voltage as a parameter. Though the coefficient of flowrate is dependent on both the pulse width and pulse voltage, the total flowrate coefficient changes monotonically for the most part when pulse voltage is constant. Accordingly, by experimentally investigating the relationship between pulse width and this total flowrate coefficient in advance, it is possible to measure minute and low pressure flowrates using our test apparatus. Ⅲ-2 Orifice Flowmeter The relationship between the mass flowrate Q and differential pressure Δp can be expressed as the following equation Q 1 A 2 p (2) Here, ρ 1 is the gas density upstream of the orifice, A the area of orifice aperture and η the total flowrate coefficient of the orifice. The coefficient η is designated by the flowrate coefficient for incompressible flow, C, and the compensation coefficient of the gas, ε, as follows: Fig.6 Total flow coefficients versus pulse width of control signal 17 P a g e

Ⅲ-3 Flowrate Measurement Using a Hot Wire-Anemometer Flowrate can be controlled to some extent using an orifice flowmeter, but it is necessary to monitor instantaneous flowrate for high speed response control. A hot wire anemometer is a suitable sensor for this purpose. In this research, the hot wires were connected downstream near to the piezoelectric valve and tests were made to see if we could measure instantaneous flowrate. The hot wires were made of platinum and mounted in the V-shape inside an electrically insulated tube of a 5 mm inner diameter as shown in Fig.1. The heat H radiated from the hot wires to the surrounding medium can be expressed using King's equation [6] as follows. a b U T W T f H (4) Here, a and b are constants, while U is the averaged flowrate in cross-section, T w the temperature of the hot wires and T f the temperature of the medium. In general, the sensitivity to changes in resistance in the hot wires is affected by the averaged flowrate, but it has been electrically linearized by using Eq. (4). The flowrate is obtained by multiplying the crosssectional volume by the average flowrate. The time constant of the flowmeter M can be estimated from the following equation [7]: probably due to turbulence in the flow. The graph certainly indicates that the response time of the hot wire is within the 1 ms. Although the changes in the graph shows a 25 ms period flow repeatedly discharged by the valve, an offset signal remains in the graph, never returning to zero. This indicates that the piezoelectric valve cannot operate follow the fast movement of the input signal. Fig.7 Flow rate variances measured by the hot-wire anemometer mcvr M (5) 2 I R 2 f Here, m is the mass of the hot wires, c v the specific heat of the hot wires, R f the resistance of the hot wires at the medium's temperature, ΔR the deviation in resistance from R f caused by the flow, α the temperature coefficient of resistance, and I the electric current flowing through the hot wires. Substituting representative values for a platinum wire of 30 μm in diameter, the time constant results in approximately 0.25 ms. Figure 7 shows an example readout of instantaneous flowrate measured at a pulse period of 25 ms and pulse width of 15 ms. No delay time of sensor response can be recognized at this time scale, therefore the chart would appear to exactly reflect the change in flowrate based on the piezoelectric valve operation. As control voltage becomes higher, that is, as flowrate becomes higher, short-period tiny variations are seen in the detected signal, which are Fig.8 Response of the piezo-electric valve estimated by the relation between an input signal of the pulse generator and an output signal of the hot-wire anemometer Figure 8 shows the input control voltage and output signal from the hot wire anemometer for a control voltage of 2.5 V, pulse period of 160 ms and pulse width of 110 ms. The output signal exhibits a delay 18 P a g e

time of approximate 70 ms with respect to the input voltage during the valve opening. As already described in section Ⅲ-1, a constant flowrate in measuring the flowrate of a single pulse could not be obtained with a shorter pulse width, because of valve operation delay. According to Fig.5, the pulse width for obtaining the constant flowrate at a control voltage of 2.5 V was 70 ms at minimum. The minimum pulse width in the previous case, 70 ms, is nearly consistent with the value as detected by the hot wire anemometer, telling us that flowrate can be correctly measured using a hot wire anemometer. As a result, it was found that the prototype hot wire anemometer of ours could sufficiently monitor flowrates of a piezoelectric valve in the circumstances of the minute and low pressure. IV. CONCLUSION In this work, we investigated the characteristics of a piezoelectric valve at low flowrate and low pressure, with the ultimate goal of designing a high speed gas supply control system for use in fusion reactors and semiconductor manufacturing systems. As a part of the work, we built prototypes of an orifice flowmeter and a hot wire anemometer to use as the sensors in the eventual control system. The threshold voltage of the piezoelectric valve was firstly investigated by changing the pulse width and the pulse period. As a result, it was found that the threshold voltage decreases with increasing of pulse width and increases with increasing of pulse period. Secondly, the averaged flowrate of single pulse was investigated by changing the pulse width and the control voltage. As a result, it was found that there is a critical pulse width which makes the flowrate constant and then keeps the constant level, and that the critical pulse width becomes larger with increasing of the control voltage. That is to say, the time needed to completely open the piezoelectric valve depends on the control voltage, with the higher the voltage, the longer the time needed. When control voltage is 2.5 V, it takes approximately 70 ms. Thirdly, it is possible to measure time-average flowrate using the prototype orifice flowmeter under the conditions of a low pressure of an order of 10-2 Pa and a low flow rate of a few tens mg/s. However, because this type of flowmeter did not conform to JIS, the total flowrate coefficients were modified and actually identified through the present experiments. The prototype of hot wire anemometer were finally built, capturing suitably the changes in flowrate under our experimental conditions and proving effective toward real-time measurement in the response time of less than 1 ms. REFERENCES [1] A. Masiello, S. Dal Bello, M. Fincato and F. Rossetto, Performance of modified pulseoperated piezoelectric valves for the gas inlet system of RFX, Fusion Engineering and Design, 82, 2007, 2282-2287. [2] M. Oldaker and K. Wright, Control of the D-T gas injection system for TFTR neutral beams, Fusion Engineering, 1991 Proceedings, 14th IEEE/NPSS Symposium, 1992, 54-57. [3] S.C. Bates and K.H. Burrell, Fast gas injection system for plasma physics experiments, Review of Scientific Instrument, 55-6, 1984, 934-939. [4] W. Huang, Z. Zhao, Y. Zhao, Q. Qi and Q. Huang, Dynamic characteristic research for piezo pneumatic intelligent valve positioned, Industrial Electronics and Applications, ICIEA 2008. 3rd IEEE Conference, 2008, 665 669. [5] P. Sichta, J. Chu and D. Mueller, TFTR realtime control applications using the digital plasma control system, Fusion Engineering, 17th IEEE/NPSS Symposium, 1997, 501 504. [6] L.V. King, On the Convention of Heat from Small Cylinders in a Stream of Fluid, Phil. Trans. Roy. Soc., A214, 1914, 373-432. [7] R.F. Blackwelder, Hot-wire and hot-film anemometers, Meth. Exper. Phys.: Fluid Dynamics, 18A, (Academic Press, 1981)259-314. 19 P a g e