TANK SUMPS SINGLE WALL & DOUBLE WALL

Similar documents
SINGLE-WALL TANK SUMPS INSTALLATION INSTRUCTIONS & OPERATING GUIDELINES

DOUBLE-WALL TANK SUMPS INSTALLATION INSTRUCTIONS & OPERATING GUIDELINES

OIL / WATER SEPARATORS UNDERGROUND FIBERGLASS STORAGE TANKS MODELS: CSI-10 / CSI-15 / UL 2215

FIBERGLASS TANK SUMPS

The World s Leading UST and AST Containment Leak Repair Products

FLOWTITE WATER STORAGE UNDERGROUND FIBERGLASS TANKS

The World s Leading UST and AST Containment Leak Repair Products

TAMDID PIPES GRP MANHOLE BROCHURE

Weholite LIGHTWEIGHT PIPE SYSTEM

CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE

GRP Composite Manhole Covers & Underground Containment Systems. We ve got you covered RETAIL FUELLING INDUSTRIAL COVERS TRENCH COVERS STEAM COVERS

A. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.

Adam Sweet 2KGAL DW AST DUAL FUEL STORAGE TANK FOR A GENERATOR - NO DRAWINGS 5/9/2017 False

Tank Sump Manual. Product Manual * Publication Number: TSM-0001 * Issue Date: 05/27/09 Supercedes: 11/01/07

Khalid SINCE 1997 TECHNICAL MANUAL 2017 GRP MANHOLE LINER & ACCESSORIES

DUO-THERM 505 Specification Guide

Lubrication Labeling and Identification

Tough pipe for a tough environment

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

The World s Leading UST and AST Containment Leak Repair Products

Distributed by: BEST MATERIALS Ph: , Fax:

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

HT-406 Specification Guide

T TABLE OF CONTENTS SPUNWRAP COLLAR

SECTION 39 - MANHOLES TABLE OF CONTENTS

Fuel Handling Piping Systems RED THREAD IIA, DUALOY 3000/LCX, 3000/L

INSTALLATION MANUAL. B-710/760 H20 SERIES MODULAR UST to AST TRANSITION SUMP

Overview. Advanced Dual Wall Profile Construction. Superior Polypropylene Material

Simplex Fiberglass Lift Station: Hard Piped

Utility Cabinet System (UCS)

FIBERGLASS MANHOLE Installation Instructions

FIBERGLASS MANHOLE Publication No. MAN 4033B Effective Date September 1, 2013

INSTALLATION INSTRUCTIONS BRAVO FIBERGLASS SD-AB SERIES FOR DOUBLE WALL FRP SUMPS ONLY FOR RETROFITTING ALL FLEXIBLE ENTRY BOOTS

INDUSTRIAL PIPE FITTINGS, LLC

TECHNICAL SPECIFICATION FOR CURED-IN-PLACE MANHOLE REHABILITATION LINER SYSTEM

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings

POLYMER CONCRETE 800 NON-SHRINK VINYL ESTER POLYMER CONCRETE, CONCENTRATED HYDROFLUORIC ACID RESISTANCE

WATERPROOF X 1 INJECTION HOSE SYSTEM

HONEYCOMB TOOLING PANELS HCL-180

H. Underground Transmission System Design

B-600 Commercial Series

Underground Exhaust System

TECHNICAL SPECIFICATION

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

4 ft. and 6 ft. Downstream Defender Handling and Installation Instructions

INIZIATIVE INDUSTRIALI


Captor Containment DOUBLE WALL TANK SYSTEMS.

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

An Introduction to Pressure Sewers. Copyright Submersible Wastewater Pump Association (SWPA)

INSTALLATION INSTRUCTIONS

Captor Containment. DOUBLE WALL TANK SYsTEMS.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

GREEN THREAD Piping Systems

San Antonio Water System Standard Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

Installation Instructions

3/23/2016. Happy Pi Day! What We Will Discuss. Best Practices for Precast Concrete Tank Inspections

POLYETHYLENE LINED PRODUCTS PROJECTS TABLE OF CONTENTS IMPACT BAFFLES CATCH BASINS MANHOLE MATERIALS LARGE DIAMETER ROUND MANHOLES

Hydrophilic Polyurethane Grout

Injection Systems for Concrete Structures. Causes, Remedies and Repairs

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

ANCHOR-LOK TM Lining Systems

Specifications: Simplex Fiberglass Lift Station: Rail Pipe. Simplex Fiberglass Lift Station: Pre-Packaged Fiberglass Systems

Multicell. Vikimatic MultiCell Conduit Systems MULTICELL

Presented by: Thermoplastic Piping

CS-75 Water-Based Adhesive Surface Primer

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL HEALTH ON-SITE WASTEWATER SECTION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY CAST-IN-PLACE. Section CAST-IN-PLACE CONCRETE MANHOLES

D-10 OUTLINE SPECIFICATION FOR PRE FAB Undergrd Piping System

San Antonio Water System Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

TechMech Engineering Products & Services. Rajkot, Gujarat (India) Complete Composite Solution

Hydrophilic Polyurethane Grout Cartridge Application

Method One: Liner/Bladder Assembly-Inversion Method.

The Weak Links in the Wastewater Collection System: Manholes and Access Devices. Antonio V Almeida, PE CMOM 2014 Austin Texas August 19, 2014

SECTION XXXX POLYMER CONCRETE PUMP STATIONS

Prestressed Concrete Tanks. Design & Construction

PVC PRESSURE FITTINGS

PEN SEAL. Pipe Penetration Seals

CORRUGATED METAL PIPE Rugged, Dependable, Efficient

SAMPLE SPECIFICATIONS FOR PREFABRICATED FRP LIFT STATIONS

INSTALLATION INSTRUCTIONS RC-SERIES SNAP-LOCK RETROFIT FOR FIBERGLASS CONTAINMENT SUMPS

ROTH MultiTank. Call or visit our web site at

Equipment Catalog. Most Cost Effective Longest Lasting. Manufactured by

ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

UNITED INDUSTRIES GROUP INC.

THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS TM. HP Storm Pipe 12 60

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

SECTION GRAVITY WASTEWATER LINES

CHEMICAL WASTE OVERVIEW CONTINUED

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

is Central. Gas Water & Waste Water Energy Industrial Your One-Stop Source State-of-the art manufacturing

SceptaCon Trenchless Raceway for Electrical and Telecommunication Cables

ReCote Finish System over Concrete

Operating Instructions

RETROFIT-SD-AB INSTALLATION INSTRUCTIONS

SaniTite. HP Sewer Pipe 300 mm 750 mm

Exceeding the Standards in Secondary Containment. Quality Fiberglass Secondary Containment Products CATALOG MEMBER.

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

Transcription:

TANK SUMPS SINGLE WALL & DOUBLE WALL

FIBERGLASS TANK SUMPS Containment Solutions, Inc. (CSI), pioneered a technology in 1965 to manufacture the first fiberglass petroleum storage tank to combat the shortcomings of steel tanks. The long-term performance and non-corrosive nature of fiberglass was key to the tank s success in the industry. The overwhelming popularity of fiberglass storage tanks soon created a demand for fiberglass tank sumps. Tank sumps are protective enclosures for pumps, piping and other accessories above the tank top. Tank sumps should be watertight and durable since they will protect the surrounding environment in the event of a piping leak. For nearly 20 years CSI has been perfecting the fiberglass tank sump design and installation process creating the most reliable and contractor friendly sump line available. Our proven technology has been utilized in thousands of installations. Fiberglass tank sumps are installed to protect the surrounding environment from potential leaks and provide a watertight access point to service pumps and piping. TABLE OF CONTENTS Introduction 1 CSI Tank Sumps 2 Typical Tank Sump Design 3 Watertight Lids 5 Installation 6 REASONS FOR CHOOSING A CSI TANK SUMP 30-Year Structural and Corrosion Warranty Extensive Fuel Compatibility Contractor Friendly EZ-Fit Adhesive Channel Watertight Lids and Joints 1 INTRODUCTION

FULL LINE OF PROTECTION Protecting your storage system and the surrounding environment starts with selecting the right storage tank but the tank only protects the product it contains. A complete fuel storage system should also include protecting the components that connect to the tank. Pumps and piping often require annual or semi-annual maintenance and testing. Once buried, the components are difficult to access and impossible to safeguard without watertight tank sumps. Tank sumps are available in 42, 48, and 54 diameters. SINGLE-WALL TANK SUMPS Containment Solutions tank sumps are manufactured using the same technology as our fiberglass tanks. We use a special blend of glass and resin which is carefully metered during fabrication to ensure a consistent wall thickness. Most CSI non-corrosive fiberglass tank sumps are light enough to be installed without mechanical equipment, and all are durable enough to protect critical components for decades. Tank sumps typically fit on the same truck as the tank which reduce shipping expenses, and like our tanks, CSI sumps with EZ-Fit adhesive channels carry a 30-year structural and corrosion warranty, which is the most comprehensive coverage in the industry. DOUBLE-WALL TANK SUMPS Containment Solutions has earned a reputation for double-wall reliability as a result of our hydrostatic tank monitoring technology. We have simply adapted the same expertise to the fiberglass tank sump. CSI double-wall tank sumps were designed to satisfy current regulations while anticipating future requirements. Competitor sumps bond the inner and outer sump walls with fiberglass fabrics which often cause communication errors triggering false alarms in the monitoring system. CSI double-wall sumps are built with 100% separation between sump walls. This open environment offers an unobstructed pathway for fluid monitoring which means 360º protection and true secondary containment. WATERTIGHT DEPENDABILITY CSI single and double-wall tank sumps utilize a unique EZ-Fit adhesive channel, facilitating a permanent and watertight joint. The joint allows sumps to be installed in manageable pieces making installation more convenient and avoiding confined space requirements. DOUBLE-WALL TANK SUMP JOINT SINGLE-WALL TANK SUMP JOINT CSI TANK SUMPS 2

TYPICAL TANK SUMP DESIGN 34 Lid O.D. 32 ¾ Neck O.D. Watertight Lid Enclosure Top 32 I.D. Round Body Extension EZ-Fit Adhesive Joint L 4 0 Polygon or Round Sump Body 19 2 0 EZ-Fit Adhesive Joint Containment Collar 4½ 16 42 I.D. SINGLE-WALL TANK SUMP WITH FILL/VAPOR LID MODEL: SW PTS (WT34) (FV 2/15/16) 42/8-4 TANK SUMP OPTIONS Single-Wall (SW) or Double-Wall (DW) Construction Watertight Lid (WT) 34 O.D. 40 O.D. Sump Diameter 42, 48, 54 8 Flat Panels on Polygon Base MODEL- SW PTS (WT34) (FV 2/15/16) 42/8-4 Polygon Tank Sump (PTS) Round Tank Sump (RTS) Fill/Vapor Cuff Orientation: 1 st Number - # of Cuffs 2 nd Number - Size of Cuff O.D. 3 rd Number - Radius of Cuffs Total Length (L) of Body Extension, Enclosure Top and Lid RTS - 3', 4', 5', 6', 7 PTS - 3, 4', 5', 6', 7' 3 TYPICAL SUMP DESIGN

CONTAINMENT COLLARS The protection of storage system components above the tank top begins with the containment collar. CSI containment collars are factory bonded to the tank wall and are available in single and double-wall models. The containment collars are built to fit CSI tank sumps and come with an EZ-Fit adhesive channel for hassle free installation. Double-wall containment collars, when combined with CSI double-wall sumps will continuously monitor the entire containment area for leaks from tank top to grade providing secondary containment for spilled liquids. POLYGON BODY Containment Solutions tank sump bodies are available in both round and polygon shapes. Polygon body styles are octagonal with 8 flat sides which allows piping to penetrate the sump at 45º and 90º angles. Electrical connections, submersible pumps, anything protected by the sump can be accessed easier using a flat-paneled polygon sump body. ROUND BODY EXTENSION & ENCLOSURE TOP Round fiberglass sump body extensions are available in one foot increments to accommodate the final tank burial depth. The enclosure top is a factory bonded transition point from the body extension to the lid and includes a watertight gasket. The enclosure top and lid are designed to fit inside standard manholes at grade. On hydrostatic double-wall models, the enclosure top includes a built in reservoir which houses a sensor for electronic monitoring. Fill/Vapor lids come in two popular cuff sizes and include an observation port as a standard feature. TESTABLE SUMP LID Watertight tank sumps are vacuum testable with the purchase of a testable sump lid. The ability to vacuum test is an efficient way of managing periodic sump testing and avoids costly disposal expenses of traditional integrity tests. The lid is equipped with quick-connect fittings exclusively designed for the CSI Watertight Test Kit. The kit includes a vacuum gun, gauge, and a bi-metal thermometer to monitor temperature change during the test. TYPICAL SUMP DESIGN 4

WATERTIGHT SUMP LID ASSEMBLIES Selecting the right single-wall or double-wall tank sump has never been easier. You simply choose the sump dimensions and level of protection you need for your project and then choose the lid based on the tank configuration. TURBINE LID TURBINE TANK SUMP LIDS Turbine tank sump lids are used at the submersible turbine end of the tank when access is infrequent and the area must be watertight. The turbine lid is made of rigid fiberglass and fits into place by simply pushing down on the lid. FILL/VAPOR TANK SUMP LIDS Fill/Vapor tank sump models are available for the fill end of the tank when multi-port manholes are used. We offer two access opening options to accommodate the most popular shroud boots and spill containment systems. 40 Quad Fill lids are also available for 48 and 54 tank sumps, contact a representative for more information. FILL/VAPOR LID w/ 15 ACCESS OPENINGS & 6 OBSERVATION PORT All configurations include an observation port allowing easy access for internal sump inspections. WATER TESTED AND WATERTIGHT Each lid assembly is tested to 1 of hydrostatic head pressure to ensure a watertight seal. Accessing a 34 lid (any model) is possible through a standard 36 manhole, and 40 lids through 42 manholes. FILL/VAPOR LID w/ 13 ACCESS OPENINGS & 6 OBSERVATION PORT The observation port is a convenient access point to inspect the monitoring sensor on double-wall sump models and perform a visual inspection of the sump interior. QUADFIL LID 5 WATERTIGHT LIDS

1 2 SIMPLE STEPS TO INSTALL: 1. Sand and clean all joint mating surfaces 3 5 7 4 6 2. Position sump on collar 3. Add catalyst to adhesive and thoroughly mix 4. Pour adhesive into grout bag 5. Using the grout bag, fill channel with adhesive making 2 consecutive 360º passes around each channel 6. Smooth adhesive, filling any gaps 7. Allow adhesive to cure 24 hours without moving the joined parts Follow the same procedures for all adhesive channels. THE ADHESIVE CHANNEL IS THE KEY Engineers might specify a CSI tank sump for a number of reasons including the impressive 30-year warranty, but contractors prefer CSI sumps for the ease of installation. Each sump section is manufactured with an EZ-Fit adhesive channel which has enough room for the adjoining sump component and our adhesive mix which seals and hardens, creating a permanent joint. This new joint is leak free and watertight. The two part design eliminates the need to perform a confined space entry on deeper burials. With our adhesive kits (Kit-AD), a permanent watertight connection has never been easier. INSTALLATION 6

CONTAINMENT SOLUTIONS MANUFACTURES: Underground and Aboveground Storage Tanks Urea DEF Storage Tanks Automotive Oil and Lubricant Storage Tanks Oil/Water Separators and Interceptors Flowtite Water Tanks Chemical Storage Tanks Fiberglass Manholes and Wetwells 5150 Jefferson Chemical Road Conroe, TX 77301 Phone: (936) 756-7731 www.containmentsolutions.com Copyright Containment Solutions, Inc. All Rights Reserved January 2014 Pub. No. ACC 5025C