ENGINEERED SOLUTIONS. Terre Arch Concrete Detention/Infiltration. Solutions Guide

Similar documents
ENGINEERED SOLUTIONS. CON/SPAN Concrete Detention/Infiltration. Solutions Guide

ENGINEERED SOLUTIONS

ENGINEERED SOLUTIONS

ENGINEERED SOLUTIONS

ENGINEERED SOLUTIONS. Filterra Bioretention System Solutions Guide

ENGINEERED SOLUTIONS. ChamberMaxx. Open-Bottom Infiltration

A-2000 PVC Pipe for Storm Sewers and Drainage

STORMWATER PIPE STRUCTURES

ENGINEERED SOLUTIONS

ENGINEERED SOLUTIONS. low impact development application guide

Metal Detention/Retention Products

Underground Systems: Workshop & Info Session

Stormwater Solutions Overview

ENGINEERED SOLUTIONS. StormFilter Inspection and Maintenance Procedures

A-2000 PVC Pipe for Sanitary Sewers

ENGINEERED SOLUTIONS. CDS Guide Operation, Design, Performance and Maintenance

ENGINEERED SOLUTIONS. DuroMaxx. Rainwater Harvesting Cisterns

A Forterra Company UrbanPond

ENGINEERED SOLUTIONS. The Stormwater Management StormFilter. Solutions Guide

ENGINEERED SOLUTIONS. The Stormwater Management StormFilter. Solutions Guide

ENGINEERED SOLUTIONS. CDS Inspection and Maintenance Guide New Jersey

ENGINEERED SOLUTIONS. Airport Solutions

Jensen Deflective Separator (JDS) Stormwater Treatment Unit

A-2000 PVC Pipe for Sanitary Sewers

Design Manual. StormKleener Filter Cartridge System for Storm Water Management

ENGINEERED SOLUTIONS. Wastewater Solutions

STORMWATER MANAGEMENT

PEDESTRIAN & VEHICULAR STEEL TRUSS BRIDGES REFERENCE GUIDE ENGINEERED SOLUTIONS TRUSS BRIDGE SOLUTIONS.

CDS THE MOST EFFICIENT AND COMPACT. hydrodynamic separator for storm sewers

DuroMaxx Steel Reinforced Polyethylene Technology. Sanitary & Storm Sewer Reline Irrigation Stormwater/CSO/SSO Detention ENGINEERED SOLUTIONS

SECTION DOWNSTREAM DEFENDER

Under the green roof. Stormwater detention using geosynthetics. in northern California. Reviving. Geosynthetic applications.

ULTRA FLO Storm Sewer Pipe

March 21, Derek M. Berg Contech Engineered Solutions, LLC 71 US Route 1, Suite F Scarborough, ME 04074

DuroMaxx. Steel Reinforced Polyethylene Pipe. Dur A STEEL REINFORCED POLYETHYLENE PIPE. Sanitary Irrigation Storm Sewer Detention

ENGINEERED SOLUTIONS INNERFLOW INSTALLATION GUIDE

Operation and Maintenance Manual

ENGINEERED SOLUTIONS

Aqua-Swirl Stormwater Treatment System

Appendix IS-5. Drainage Study

ENGINEERED SOLUTIONS. BridgeCor Overview

Innovation In Stormwater Management

Product Catalogue. Not intended for design layouts; refer to the appropriate StormTech Design Manual for specific chamber design information.

Aqua-Swirl Stormwater Treatment System

CULTEC STORMWATER CHAMBER SYSTEMS

CORRUGATED METAL PIPE Rugged, Dependable, Efficient

Product Catalog. company SC-310 DC-780 SC-740 MC-3500 MC-4500

Contactor & Recharger Stormwater Chambers

StormTech Product Catalogue

Product Catalogue. Not intended for design layouts; refer to the appropriate StormTech Design Manual for specific chamber design information.

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS

4.28 Underground Detention

MC-3500 and MC-4500 Design Manual

4.8. Subsurface Infiltration

Chapter 5 Hydraulic Structures

CENTRALIZED BMPS TYPICALLY PUBLICLY OWNED & MAINTAINED BMPS, TREATING A LARGE (>20 ACRES) URBAN DRAINAGE WITH MULTIPLE LAND

Hydrodynamic Separation Product Calculator

PRIVATE STORM DRAINAGE FACILITIES REQUIREMENTS

Corrugated Metal Pipe Design Guide

BMP 6.4.4: Infiltration Trench

Features: The Most Advanced Name in water management solutions TM

STORMWATER MANAGEMENT

Retention/Detention Inspection & Maintenance

STORM AND SURFACE WATER 4-1 GENERAL...4-1

Bio-Filter TM Stormwater Biofiltration System

4.8. Subsurface Infiltration

Operation and Maintenance Manual

Section 403. DRAINAGE STRUCTURES

EnviroModule TM 2. modular underground tank systems. rainwater harvesting infiltration on-site detention bio-remediation filtration

Drainage structure refers to manholes, catch basins, leaching basins, inlets and drop inlets. Drainage structures are designated as follows.

PERKFILTER. Design Guide

ARMTEC.COM. Proven quality and dependability in drainage solutions and water treatment

4.4.6 Underground Detention

207 TEMPORARY SEDIMENT AND EROSION CONTROLS

ENGINEERED SOLUTIONS. Contech Slotted Drain

WQ-06 SAND FILTER. 1.0 Sand Filter. Greenville County Technical Specification for: 1.1 Description

Underground Stormwater Detention and Rainwater Harvesting System for Northbrook Park District. Brett Holmes, P.E., CPSWQ

Features: The Most Advanced Name in water management solutions TM

6 STORMWATER IMPROVEMENTS

Aqua-Swirl Stormwater Treatment System

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

Model Results Operation and Maintenance (O& M) Results Cost-Benefit Analysis Results Conclusions

Chapter 6 Sand Filtration Treatment Facilities

6 STORMWATER IMPROVEMENTS


and Green Infrastructure

Advanced Stormwater Biofiltration. MWS Linear

Appendix J: Storm Conveyance Design Parameters

SECTION STORM DRAINAGE DESIGN, GRADING, AND WATER QUALITY TECHNICAL CRITERIA TABLE OF CONTENTS PAGE 402 STORM DRAINAGE DESIGN CRITERIA 400-1

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE.

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Subsurface Infiltration SMP One-Sheet - download a summary of this tool, with quick reference facts for. clients and developers.

Table 1: Water Quality Event (WQE) Design Intensities. i 1 (t c 5 min) (in/hr) a b. tc c

EFFECTIVE AND EASILY MAINTAINED TREATMENT SOLUTIONS

TABLE OF CONTENTS SECTION 700 STORM DRAINAGE STANDARDS...

MATERIALS STORM DRAIN PIPE TABLE OF CONTENTS

PRODUCT CATALOG MC-4500 SC-740 MC-3500 THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS

PRECAST CONCRETE ON-SITE WASTEWATER TANKS

Transcription:

ENGINEERED SOLUTIONS Terre Arch Concrete Detention/Infiltration Solutions Guide

Stormwater Solutions from Contech Selecting the Right Stormwater Solution Just Got Easier... It s simple to choose the right stormwater solution to achieve your goals with the Contech Stormwater Solutions Staircase. First, select the runoff reduction practices that are most appropriate for your site, paying particular attention to pretreatment needs. If the entire design storm cannot be retained, select a treatment best management practice (BMP) for the balance. Finally, select a detention system to address any outstanding downstream erosion. Learn more about all of our stormwater technologies at www.conteches.com/stormwater 2015 Contech Engineered Solutions LLC DYODS Design Your Own Detention or Infiltration System The Contech DYODS is an exclusive online design tool to that allows users to quickly and easily design their own detention or infiltration system. Just input your required storage volume to calculate the quantity of the material needed for your Contech CMP, CON/SPAN, or ChamberMaxx system. To use the Design Your Own Detention or Infiltration System tool, visit: www.conteches.com/dyods 2

The Terre Arch Advantage The Lowest Installed Cost The Highest Strength and Durability Contech is the exclusive seller of Terre Arch in the U.S. and International. Terre Arch is a modular, multi-chambered, precast concrete stormwater storage system that is engineered especially for underground installation. Terre Arch utilizes a proven arch design to provide a simple solution for stormwater detention and retention-recharge. Terre Arch s patented, fiber-reinforced design is lightweight, yet incredibly strong. With a load-bearing rating of HS-25 (with 12 cover from the top of the arch to final grade), each section can support heavy gross weight trucks and machinery, allowing installation equipment direct access to the site during installation, dramatically reducing installation time and labor. Each Terre Arch installs quickly, adding several hundred cubic feet of storage in a matter of minutes. Benefits 100+ year design life Minimum 5,000 psi compressive strength HS-25 load rating No concrete foundation required 12 minimum cover above arch Simple and fast installation; install 30,000-50,000 cubic feet of storage per day Provides maintenance access to individual chambered rows 3

Application Underground Storage = More Usable Land Space Terre Arch provides flexibility for stormwater detention or infiltration, allowing you to meet runoff reduction requirements by storing runoff water in underground chambers before it is infiltrated or released at a controlled rate. Terre Arch will maximize your land space by storing runoff underground. This frees up valuable land space for buildings, parking lots or green space. Because little cover is required, Terre Arch is the best solution when the site engineer is faced with site restrictions such as high ground water tables and minimum separation between the top of the underground structure and the finished grade. Terre Arch precast concrete detention system Terre Arch can be designed in HydroCAD and Streamline Technologies ICPR Perc Pack Sizing & Storage Underground storage maximizes land space Two Configurations = Flexibility in System Design Terre Arch 26 Terre Arch 26 is a connected 4 arch precast concrete structure providing 277 CF of installed storage and 152 SF infiltration area. Since it is less than 3 high, Terre Arch 26 is great for shallow sites and low drop infiltration systems. Terre Arch 48 Terre Arch 48 is a connected 3 arch precast concrete structure providing 541 CF of installed storage and 160 SF infiltration area. Terre Arch 26 Structure Pipe Dimensions Model Volume Infiltration Area Weight (approx.) Dimensions Terre Arch 26 319 CF* 152 SF 13,500 lbs. 8-0 x 19-0 x 2-10 Terre Arch 48 608 CF* 160 CF 19,500 lbs. 8-0 x 20-0 x 4-8 * Table assumes 6 stone base for TA26 and 12 stone base for TA48, with 6 cover stone over top of arch. (40% void space typical with stone) Terre Arch 48 Structure 4

A Superior Design Distribution openings in the legs of the arches equalizes flow between sections Ventilation and draining orifices prevent ponding and air pockets Adjacent units are installed with no spacing required, reducing footprint and installation costs Ideal for shallow sites requiring minimal cover and shallow inverts Bedding and Backfill Requirements The minimum cover for both Terre Arch units is 12 above the top of the arch and the maximum cover is 16 feet. Both elevations are to the top of pavement or final grade. Both Terre Arch units are appropriate for installation on a sub-base with soil bearing capacity greater than 3000 psf. For soils less than 3000 psf, Contech recommends a geotechnical engineer be consulted for appropriate soil treatment. Terre Arch 26 is installed with a 6 (minimum) stone bedding on sub-base that has a 3000 psf bearing capacity or greater. Terre Arch 48 is installed with a 12 (minimum) stone base on soils with a 3000 psf bearing capacity or greater. The minimum stone perimeter around all Terre Arch systems is 12 Learn more at www.conteches.com/detention 5

Installation Time is Money - Terre Arch Saves Both No other concrete system can match Terre Arch s ease of installation. With a properly excavated and prepared base, a Terre Arch can be set every five minutes; with installation of up to 50,000 CF of storage in 1 day, including cover and backfill. And the just in time delivery of Terre Arch reduces material handling and eliminates on-site storage. The result reduced project time, reduced man hours and significant cost savings. Rapid installation 5 minutes per section Lower installed cost compared to plastic chamber and pipe systems due to significantly less stone. Terre Arch requires less stone Maintenance Easy, Worry-Free Maintenance The Terre Arch system is designed for ease of maintenance. It is the only chamber system on the market that provides worker access from distribution boxes that extend from grade to the inside of the installed arch, providing confined space entry for removal of sediment and debris from inside the structure. Frequency of inspections will vary significantly on the local site conditions, and individual inspection schedules should be established for each site. However, visual inspections are recommended annually. When the depth of sediment accumulates over 4 inches (102 mm), cleanout is recommended via vacuum truck or other similar device. Ease of inspection and maintenance Manhole access instead of 4 inspection port 6

Pretreatment & Pipe Pretreatment Pretreatment is an important component of all stormwater detention and infiltration systems and should be considered to reduce overall sediment loading into the system. Conventional chamber systems may have impractical maintenance methods and designs that do not appropriately address long term performance concerns. Using patented continuous deflective separation technology, the CDS system effectively screens, separates and traps debris, sediment and oil from stormwater runoff. The CDS system captures and retains 100% of floatables and neutrally buoyant debris 2.4 mm or larger, even at high flow rates. It is an ideal system for treating runoff before entering Terre Arch. GRATE INLET (CAST IRON HOOD FOR CURB INLET OPENING) CLEAN OUT (REQUIRED) DEFLECTION PAN, 3 SIDED (GRATE INLET DESIGN) CREST OF BYPASS WEIR (ONE EACH SIDE) SEPARATION CYLINDER INLET FLUME INLET (MULTIPLE PIPES POSSIBLE) OUTLET OIL BAFFLE TREATMENT SCREEN SEPARATION SLAB SUMP STORAGE The CDS System Pipe Contech offers a wide variety of pipe material, thicknesses, corrugations and coatings for varying service life, hydraulic and economic needs to convey runoff to your Terre Arch system. Each of our solutions is designed for hydraulic efficiency, ease of handling and installation, durability and, of course, economy. Choose from multiple pipe options Engineer Support - The Support You Need, From a Source You Can Trust For more than two decades, Contech has helped engineers managing stormwater at sites across the country. From design project, to concept to installation, Contech has the resources to ensure your projects are completed on time and on budget: Our Team Includes: Stormwater consultants Professional engineers Regulatory specialists Installation consultants Customer service professionals LEED accredited professionals Construction professionals Field sales representatives Terre Arch Learn more at www.conteches.com/detention 7

Dig Deeper Links to Stormwater Tools: Find all the information you need at www.conteches.com, including field and laboratory test results, approvals, brochures, design guides, standard details, and specifications within the product section of our site. To use the Land Value Calculator, visit: www.conteches.com/ (Look under the Stormwater Management section to download the Land Value Calculator) lvc Connect with Us To use the Design Your Own Detention System tool, visit: www.conteches.com/ We're here to make your job easier and that includes being able to get in touch with us when you need to. Go to www.conteches.com/ dyods ConnectWithContech. To use the Design Your Own Hydrodynamic Separator tool, visit: www.conteches.com/ While you re there, be sure to check out our upcoming seminar schedule or request an in-house technical presentation. dyohds To use the Rainwater Harvesting Runoff Reduction Calculator tool, r w h - c a l c u l at o r visit: www.conteches.com/ Start a Project If you are ready to begin a project, contact your local representative to get started. Or you can check out our design toolbox for all our online resources at www.conteches.com/ To use the LID Site Planner, visit: www.conteches.com/ LIDsiteplanner designtoolbox. COMPLETE SITE SOLUTIONS ENGINEERED SOLUTIONS Stormwater Solutions Pipe Solutions Structures Solutions Helping to satisfy stormwater management requirements on land development projects Stormwater Treatment Detention/Infiltration Rainwater Harvesting Biofiltration/Bioretention Meeting project needs for durability, hydraulics, corrosion resistance, and stiffness Corrugated Metal Pipe (CMP) Steel Reinforced Polyethylene (SRPE) High Density Polyethylene (HDPE) Polyvinyl Chloride (PVC) Providing innovative options and support for crossings, culverts, and bridges Plate, Precast & Truss bridges Hard Armor Retaining Walls Tunnel Liner Plate ENGINEERED SOLUTIONS Nothing in this catalog should be construed as an expressed warranty or an implied warranty of merchantability or fitness for any particular purpose. See the CONTECH Standard Conditions of Sale (viewable at www.conteches.com/cos) for more information. 2015 CONTECH ENGINEERED SOLUTIONS LLC 800-338-1122 www.conteches.com All Rights Reserved. Printed in the USA. Contech Engineered Solutions LLC provides site solutions for the civil engineering industry. Contech s portfolio includes bridges, drainage, retaining walls, sanitary sewer, stormwater, erosion control and wastewater treatment products. For information on other Contech division offerings, visit www.conteches.com or call 800.338.1122. Get Social With Us! Terre Arch Bro 3M 11/15 We print our brochures entirely on Forest Stewardship Council certified paper. FSC certification ensures that the paper in our brochures contain fiber from well-managed and responsibly harvested forests that meet strict environmental and socioeconomic standards. Printed with soy inks FSC