Online data sheet MCS100E HW-C
A B C D E F H I J K L M N O P Q R S T Ordering information Type MCS100E HW-C Part no. On request The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. Our regional sales organization will help you to select the optimum device configuration. Other models and accessories www.sick.com/mcs100e_hw-c Product description The MCS100E HW-C uses infrared technology to analyze exhaust gas. From probe sampling to cell, all components that come in contact with the sample gas are heated to a temperature above the acid dew point to prevent corrosion. The sampling probe uses two-stage filtration, and the inlet to the analysis cell is also filtered, ensuring safe use of the system. A built-in high-temperature bellows allows for faster gas exchange, minimizing adsorption effects of HCl and NH 3. The device can be used for environmental emissions monitoring and also industrial process monitoring. An optional FID may be added to measure VOCs. At a glance Measures up to 8 IR-active gas compounds Gas paths completely heated to prevent corrosion and measurement error produced by condensation Optional zirconium dioxide sensor for O 2 measurement Supports calibration of the full system or direct calibration of the analyzer Multi-stage filtration allows safe sampling Automatic zero and span point calibration, and internal calibration filter allows for calibration without test gas Regular back-purging Incorporates temperature and flow control and automatic sampling cut-off if malfunction occurs Automatic purging protects the instrument in case of malfunction Your benefits One analyzer measures several gas components Maintenance intervals as long as six months Directly measures NO 2 with no converter required Especially low measurement ranges for SO 2, NO x, and HCl Internal calibration filter minimizes use of test gas 2 ANALYZER SOLUTIONS SICK Online data sheet 2016-11-30 09:46:27 Subject to change without notice
Detailed technical data MCS100E HW-C system Measured values Performance-tested measurands CH 4, CO, CO 2, H 2 O, HCl, NH 3, NO, NO 2, N 2 O, SO 2, O 2, gas velocity, temperature, pressure, dust concentration CO, CO 2, HCl, H 2 O, NO, NO 2, O 2, SO 2, gas velocity, temperature, pressure, dust concentration Maximum number of measurands 9 Measurement principles Gas filter correlation Spectral range 1 µm... 16 µm Length of measuring path Gas flow rate Measuring ranges Certified measuring ranges Response time (t 90 ) Accuracy CH 4 CO CO 2 HCl H 2 O NH 3 NO NO 2 N 2 O O 2 SO 2 CO CO 2 HCl H 2 O NO NO 2 O 2 SO 2 2 m 200 l/h... 1,000 l/h 0... 70 ppm / 0... 1,400 ppm 0... 60 ppm / 0... 2,000 ppm 0... 25 Vol.-% / 0... 100 Vol.-% 0... 10 ppm / 0... 1,900 ppm 0... 1 Vol.-% / 0... 40 Vol.-% 0... 30 ppm / 0... 660 ppm 0... 150 ppm / 0... 1,900 ppm 0... 50 ppm / 0... 500 ppm 0... 50 ppm / 0... 1,000 ppm 0... 1 Vol.-% / 0... 21 Vol.-% 0... 25 ppm / 0... 5,000 ppm 0... 200 mg/m³ 0... 25 Vol.-% 0... 200 mg/m³ 0... 40 Vol.-% 0... 1,000 mg/m³ 0... 500 mg/m³ 0... 25 Vol.-% 0... 750 mg/m³ 200 s 2 % Of measuring range full scale Sensitivity drift 2 % of the measuring range full scale value per maintenance interval Zero point drift < 1 % of the measuring range full scale value per month Reference point drift ± 2 % of the measuring range full scale value per month Detection limit < 2 % of measuring range full scale Process temperature +1,300 C 2016-11-30 09:46:27 Online data sheet Subject to change without notice ANALYZER SOLUTIONS SICK 3
A B C D E F H I J K L M N O P Q R S T Sample gas temperature +220 C Process pressure Process gas humidity 900 hpa... 1,100 hpa Non-condensing Ambient temperature +5 C... +35 C Storage temperature 20 C... +60 C Ambient pressure 900 hpa... 1,100 hpa Ambient humidity 90 % Relative humidity; non-condensing Conformities HJ/T 76-2007 Enclosure rating IP 65 Analog outputs Analog inputs Digital outputs Digital inputs Indication Input Operation Menu languages Model Dimensions (W x H x D) Weight 4 outputs: 0/4... 20 ma, 500 Ω 4 inputs: 0/4... 20 ma 12 outputs: 40 V, 1 A 4 inputs: 50 V AC, 4 A / 24 V DC, 4 A LC display Functional keys Menu-driven operation via LC-display and membrane keyboard English Indoor analyzer cabinet 800 mm x 2,200 mm x 800 mm 300 kg Material in contact with media PTFE, CaF 2 Power supply Sample gas connections Voltage Frequency Current consumption Power consumption 220 V 50 Hz Auxiliary gas connections DN 6/8 Corrective functions Test functions System components Integrated components Options Depending on type and length of sample gas line Analyzer: 850 W Swagelok 8 mm Manual or automated adjustment with test gases Internal zero and reference point check Analyzer Sampling probe Sample gas line Control unit Sample gas pump Pressure sensor Flow sensor Zirconium dioxide sensor (oxygen measurement) 4 ANALYZER SOLUTIONS SICK Online data sheet 2016-11-30 09:46:27 Subject to change without notice
Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is Sensor Intelligence. Worldwide presence: Contacts and other locations www.sick.com SICK AG Waldkirch Germany www.sick.com