THE USE OF LIGHT PIPES FOR DEEP PLAN OFFICE BUILDINGS A case study of Ken Yeang's bioclimatic skyscraper proposal for KLCC, Malaysia

Similar documents
An assessment tool for selection of appropriate daylight solutions for buildings in tropical and subtropical regions:

Veronica Garcia-Hansen Gillian Isoardi Michael Hirning John Bell

New solar shading system based on daylight directing solar glass lamellas

ANALYSIS AND MITIGATION OF THERMAL EFFECTS ON A LARGE FACADE-MOUNTED PV ARRAY

Introduction to basics of energy efficient building design

THERMAL ANALYSIS OF A FACADE-MOUNTED PV ARRAY

The Assessment of Advanced Daylighting Systems in Multi-Story Office Buildings Using a Dynamic Method

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

Poor distribution & glare

An enhancement of the daylighting from side-window using two-section venetian blind

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.2 Replacement of glazing

Solar Shading System Based on Daylight Directing Glass Lamellas

546: High Altitude Design, Optimising Residential Architecture in the Alborz Mountains, Iran

COMPARATIVE EVALUATION OF SIDE-DAYLIGHTING STRATEGIES

THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING AND ENERGY PERFORMANCE FOR AN OFFICE BUILDING IN CANBERRA

COPYRIGHTED MATERIAL. Contents Overview WHAT'S IN THE SWL PRINTED WHAT'S IN THE SWL ELECTRONIC I NAVIGATION 20 VIII DETAILED DESIGN STRATEGIES E.

DAYLIGHTING PERFORMANCE OF TOPLIGHTING SYSTEMS IN THE HOT AND HUMID CLIMATE OF THAILAND

Energy Saving Benefits of Daylighting Combined with Horizontal Exterior Overhangs in Hot-and-Humid Regions

Utilization of Combined Daylighting Techniques for Enhancement of Natural Lighting Distribution in Clear-Sky Residential Desert Buildings

INTUITIVE AND OBJECTIVE APPROACHES TO DAYLIGHTING A NEW ENGLAND ELEMENTARY SCHOOL Michael Rosenfeld 1

NRC CONSTRUCTION TECHNOLOGY UPDATE

Managing Light & Daylight Efficiently for Tropical Office Buildings

5.0 Daylighting Analysis (Breathe Study)

Daylight Harvesting in Tropic

PARAMETRIC MODELLING FOR THE EFFICIENT DESIGN OF DAYLIGHT STRATEGIES WITH COM- PLEX GEOMETRIES

Effect of Building Orientation and Window Glazing on the Energy Consumption of HVAC System of an Office Building for Different Climate Zones

Field measurements of performance of roof solar collector

Daylighting Design 12 th Annual Building Codes Education Conference March Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design

SHIMOGA KARNATAKA INDIA 1000 Person Naturally Ventilated Office

Chapter 7. Passive Solar Contents

Better Daylight and Natural Ventilation by Design

Design and retrofitting of a hybrid building in Athens

Menara Mesiniaga. Ken Yeang. Architecture 489 Erica Leigh Walczak. Structure Innovations 40

Young Cities Research Briefs 07 Architectural Energy Efficiency

EXTERNAL SHADING DEVICES

Enhancing visual comfort in classrooms through daylight utilization

STOP & SHOP, NEW PALTZ, NY

Lecture 3: Utilization of Passive Solar Technology

The Performance of External Shading Devices and Daylighting Rule of Thumb for a Tropical Climate

Part 1 Review Questions on material covered in Midterms I & II

CONTROLITE. Intelligent Daylighting System FACADE SKYLIGHT

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

Daylighting Strategies and Case Studies

climatic responsive tall buildings a sustainable design approach

HOW TO CREATE AFFORDABLE PASSIVE HOUSE DESIGN. Andrew Lundberg Passivate

Thermal Performance of Toplighting Systems in a Hot and Humid Climate: Thailand

Comparative Performance of Internal Venetian Blind and Roller Blind with Respects to Indoor Illumination Levels

3C.1 Passive Solar Design National Sustainable Building Advisor Program

Energy Savings Benefit from Passive Architecture

Perception of Thermal Comfort for Naturally Ventilated High School Classrooms in San Rafael, CA

Technical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept.

Application of Innovative Daylighting in High-rise Buildings (Malaysia)

The effect of shading design and control on building cooling demand

Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 1

International Journal of Advance Engineering and Research Development

Glass in Solar Energy: Enhancing Quality of Life and Conserving Energy

C C: Taff Vale Redevelopment

Ventilated Illuminating Wall (VIW): Natural ventilation and daylight experimental analysis on a 1:1 prototype scale model

BUILDING INTEGRATION OF RENEWABLE ENERGY SYSTEMS TOWARDS ZERO OR NEARLY ZERO ENERGY BUILDINGS

Daylight Factor Analysis with Slat Angle Control for Glare Reduction in a Three Storied Office Building

Office Building-G. Thesis Proposal. Carl Hubben. Structural Option. Advisor: Dr. Ali Memari

The Role of Roof Shapes in Design of Green Building Systems (Case Study: Iran, Tehran)

SAGEGLASS VARIABLE TINTED GLAZING INPUT SHEET FOR DIAL+ SOFTWARE

optimize daylighting Opportunities

Project 2 : Integration with Design Studio 5 Lighting Analysis

Assessment of shading devices with integrated PV for efficient energy use

Architectural Integration of Solar PV into Building Design

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

Compact cities in a sustainable manner

Annexing Green Building Rating Points through Multipurpose Vertical Light Pipes

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

SOLAR ENGINEERING OF THERMAL PROCESSES

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

Influence of Building Orientation on the Indoor Climate of Buildings

Part 1 Review Questions on material covered in Midterms I & II

Bradley Sisenwain Final Report Gateway Community College Lighting Electrical Option Architectural Breadths New Haven, CT

SOLAR PHOTOVOLTAIC ENERGY

171: An urban office designed for the southern Brazilian climate

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

SIMPLE INVESTIGATIONS OF TENSILE MEMBRANE ACTION IN COMPOSITE SLABS IN FIRE

User Interactions with Environmental Control Systems in Buildings

Alternative Sources of Energy

Characterization and performance evaluation of solar shading devices

THE CARBON NEGATIVE BUILDING FAÇADE

Buildings with large glazed surfaces: optimization of solar control strategies in relation to the building's thermal inertia

St Loyes Extra Care Facility PHPP Pre-Assessment Report

The feasibility of natural ventilation in plus energy houses in Germany

BEHAVIOUR OF REINFORCED CONCRETE STRUCTURES IN FIRE

Optimization of Thermosiphon Solar Water Heating systems working in a Mediterranean Environment of Cyprus

Monitoring of Advanced Facades and Environmental Systems

INTEGRATION OF LIGHTING PERFORMANCE INDICATORS INTO A DASHBOARD FOR DAYLIGHTING ASSESSMENTS. Beatriz Piderit 1, Daniela Besser 2

Solar Flat Plate Thermal Collector

An Analysis of Variation of Ceiling Height and Window Level for Studio Architecture in Malaysia

Passive cooling in the works of A.N. Tombazis and associates

carbon-neutral architectural design Pablo La Roche CRC Press Taylor & Francis Croup Boca Raton London NewYork CRC Press is an imprint of the

UT Zero-Energy House Divide University of Tennessee, Knoxville Arc 572 I Spring 2008

productive architecture Kiss + Cathcart, Architects 44 COURT ST. TOWER C, BROOKLYN, NY t f

Irvine CA MAE ROW ROW ROW. Office Lighting Plan. Page 93

Solar Energy Technologies

Transcription:

THE USE OF LIGHT PIPES FOR DEEP PLAN OFFICE BUILDINGS A case study of Ken Yeang's bioclimatic skyscraper proposal for KLCC, Malaysia Veronica Garcia Hansen*, Ian Edmonds**, Richard Hyde*** *School of Design and Built Environment, Queensland University of Technology ** Centre for Medical, Health and Environment Physics, Queensland University of Technology ***The Centre for Sustainable Design, The University of Queensland v.garciahansen@qut.edu.au, i.edmonds@qut.edu.au, r.hyde@mailbox.uq.edu.au SUMMARY The case study examines development work on the application of light pipe technology for a new bioclimatic high rise building in Kuala Lumpur, Malaysia. The paper outlines the architectural and environmental issues associated with the design of this building. It presents theoretical modelling and simulation work done to test the feasibility of using light pipes to increase daylight in the building and reduce the need for electric lighting. The benefits of this strategy are discussed. INTRODUCTION Waterfront House is a high-rise building proposed for Kuala Lumpur, Malaysia (Figure 1). It will be located in the commercial centre of the city and is sited adjacent to the world tallest building, Petronas Towers (Figure 2). The site has prominence in terms of its physical position and its architectural iconography. Trying to balance an economically driven commercial development with the environmental and social needs of the international move towards sustainability has created the intrinsic challenges of the design problem. This paper argues that this challenge can be met through innovation in the development of technical systems, appropriate technical synthesis with the integration of these technologies in the building design and the work of a multidisciplinary team. The first part of the paper explains the design problem, describes the design parameters and outlines the daylight strategy. This is followed by the science principles and experimental work to test the feasibility of the solution proposed. Finally, discussion on the general applicability of this solution is provided. THE DESIGN PROBLEM To meet the prescribed economic criteria there is a need to minimize a number of the physical parameters of the building, for example, external wall thickness, vertical support size, horizontal support, vertical circulation and floor-to-floor height (Yeang, 1996). These economic criteria result in a high-energy consumption solution and a building that relies on active systems for climate control. The bioclimatic building type, as defined by Yeang (Yeang, 1999) has a passive low energy design approach that makes use of the ambient energies of the climate of the locality to create conditions of comfort for the users of the building, and it challenges some of the economic criteria in favour of a reduced energy solution through mixed mode design- active and passive systems. A different strategy has been devised which seeks to make significant savings to the power demand from electric lighting and air conditioning. Waterfront House design parameters are: floor to floor height of 4.6 m west located core (as a thermal buffer) ambient lighting level of 300lux with task lighting of 600lux deep plan floor plate of 2000 m 2 light directing shading to provide daylight to the edge of the floor plate light pipes to provide daylight in the centre of the floor plate natural ventilation through wind wall features

The focus of this paper is on the daylight strategy for natural lighting enhancement in the building. This strategy includes the use of light shelves to increase the passive illuminated zone, and the use of horizontal light pipes to decrease the dependence on electrical light of the active zone (centre of the floor plate). The paper will particularly discuss the proposal of introducing light pipes in the building, including experimental work performed at Queensland University of Technology (QUT). The technical design integration work will be carried out at University of Queensland (UQ). Figure 1: Waterfront House elevations (source Ken Yeang) Figure 2: Site plan (source Ken Yeang) PROPOSED LIGHT PIPES For economic reasons (i.e. high land price in the inner city) the Waterfront House building has a large floor plate. A 20 m deep plan floor is not susceptible to good natural lighting, and therefore four light pipes per floor, coupled with laser cut panels have been proposed to improve the daylighting performance of office space in the building (figure 3). The light pipes are designed to channel sunlight into the deep zone of the office plan as sunlight falls on the western façade of the building. Figure 3: Light pipes in plan (yellow), aligned to come through the westerly core, (source Greg Evans). Passive zone: spaces located on the perimeter that can benefit from the ambient environment (daylight, solar gain, ventilation, view), it is normally twice the floor to ceiling height (Baker and Steemers, 2000).

The light deflecting panel at the aperture of the light pipes enhances the performance by redirecting sunlight more directly along the axis of the light pipes (figures 4 and 5). Figure 4: Light pipe with clear glazing. Light at any high angle coming into the pipe will be lost due to multiple reflections. Figure 5: Light pipe with LCP. LCP redirects the light along the pipe reducing the number of reflections and therefore loss of intensity. This report summarizes the theory of the light pipes, outlines the application of light pipe technology for the Water Front building, presents the scale modelling of the light pipes, the results and finally the conclusions. APPLICATION OF LIGHT PIPE TECHNOLOGY TO THE WATER FRONT HOUSE BUILDING The design for the Water Front house building places the utilities zone of the building against the windowless West wall with the workplace zone extending three quarters of the way across the building from the Eastern side of the building as illustrated in Figures 3 and 6. As it is expected that the Eastern perimeter zone will be well illuminated during the morning and less adequately illuminated during the afternoon the objective of the light piping system is to illuminate the inner zone of the work area- more particularly in the afternoon. The light pipe takes light incident on the Western facade through the plenum area above the utilities zone and distributes light into the inner zone of the building. The performance of the long light pipes (24 metres long and 4 per floor) is enhanced with: 1) a laser cut panel light deflector at the input aperture to deflect high elevation light more directly along the axis of the pipe, 2) a light extraction system to extract the required proportion of piped light into the inner zone and 3) a light spreading system (shown in Fig. 12 and Fig.14) to distribute the light away from the area directly below the light pipe and more evenly over the zone. Figure 6: light pipes section

Laser cut panel (Edmonds, 1993) is produced by making parallel laser cuts in transparent acrylic panel each cut becoming a thin mirror, which provides powerful deflection of off-normal light as illustrated in Fig.7. The fraction of light deflected, fd, depends on the angle of incidence, i, and the cut spacing to cut depth ratio, D/W, as shown in Fig. 8 for three nominal D/W ratios. Figure 7: laser cut panel section. Incoming light deflected and transmitted. Figure 8: Fraction of incident light deflected for different spacing to depth ratios, D/W. For effective light collection and deflection of incident sunlight into the light pipe the laser cut panel is placed at an angle to the input aperture as shown in Fig. 9. Incident sunlight is split into a deflected beam, (fd), and an undeflected beam, (fu = 1 fd). High elevation sunlight is deflected more axially down the pipe and therefore makes fewer reflections in traversing the pipe than the undeflected beam. The transmission of light through the pipe is given by T = r N, where r is the reflectance of the pipe surface and N is the number of reflections along the pipe which bring the light to the point of interest. In the model used in this work the reflectance of the pipe material (aluminium) was 0.85. For example, if the defected beam makes two reflections before reaching an output aperture, the transmission is T = 0.85 2 = 0.72, while for the undeflected beam, for example, making 12 reflections before reaching an output aperture, the transmission is T = 0.85 12 = 0.14. Figure 9: Detail of the laser cut panel as light collector, and deflection of incident sunlight into the light pipe.

In the present application the pipe input apertures are on the Western façade and sunlight enters the apertures from 12 noon through the afternoon as illustrated in Fig. 10. It is evident from this illustration that the amount of light incident on the apertures and transmission of this light through the pipes depends in a fairly complicated way on the sun elevation angle and, therefore, on time of day. 12:30 pm 3:00 pm Incident light 2:00 pm laser cut panel 4:00 pm deflected beam of light undeflected beam of light Figure 10: Transmission of the light through the pipes for the deflected and undeflected beam of light at different times of the day. As the light traverses the pipe specified proportions of the light must be extracted at intervals along the light pipe to provide the desired light distribution (usually uniform distribution) below the light pipe. The principle of a light extraction system is illustrated in Fig. 11. In this example the same amount of light is extracted at each aperture. To achieve this the first extractor panel is made sufficiently reflecting to deflect one quarter of the light. The second deflects one third of the remaining light, the third panel deflects one half and the final extractor deflects all of the remaining light. More complicated ratios may be derived to account for transmission loss in the pipe that occurs between each extractor (Edmonds et al., 1997). As is evident in Fig. 10 the transmission loss will vary with incidence angle of the light and hence with time of day. Therefore it is expected that the distribution of light from the light pipe will also vary with time of day. Figure 11: light extraction in the light pipes Figure 12: Laser cut light spreading panel.

As the light is directed near axially and is extracted by reflection off planar extractors it follows that the extracted light is emitted into the room as an approximately vertical and fairly well collimated beam (figure 13). In this case, only the area directly below the apertures is well illuminated. To distribute the light more widely a light spreading system comprising a triangular arrangement of laser cut panels was used. Fig. 12 shows a cross-sectional view of the light pipe and light spreading arrangement. A high proportion of downwardly directed light is deflected by the panels over the ceiling to either side of the light pipe thereby improving the distribution of light in the room by spreading the light more evenly over the interior, and approaching more closely the design target of a uniform 300 lux illuminance (Fig.14). Figure 13: Distribution of the light without emitters. Figure 14: Light redirected to the ceiling by LCP emitters. SCALE MODELING OF THE LIGHT PIPING SYSTEM A 1/20 th scale model of the system was fabricated, figure 15, and measurements made under direct sunlight conditions. While only one light pipe was modelled the effect of multiple light pipes was simulated by making the vertical sidewalls of the model reflecting. The grid of measurement points within the model interior is shown relative to the light pipe in fig. 16. Figure 15: scale model testing Figure 16: Measurement grid Measurements of workplace illuminance made at various sun elevations are shown in Figures 17a to 17d. It is evident that the amount of light delivered, ranging between about 200 and 300 lux over the time period from 12 noon to 4 pm contributes significantly to the illuminance level (design level 300

lux) required in the building. That the area directly below the light pipe receives up to 3 times as much light as areas to the side is due to a less than optimal design of the light spreading system. This will be improved by using laser cut panels with cut spacing to provide maximum deflection of light to the side. The emitted light shows a moderate reduction in strength with distance along the light pipes. This is due, primarily to the fact that the proportions of light extracted by the extractor panels cannot be varied to adjust for varying transmission in the light pipe as the sun elevation and time of day change. However the reduction is moderate and it is expected to be compensated by a fall off in illumination from the window walls on the Eastern façade of the building. Figure 17a: measured values for 81 o elevation sun Figure 17b: measured values for 57 o elevation sun Figure 17c: measured values for 45 o elevation sun Figure 17d: measured values for 27 o elevation sun The elementary theory of light pipe performance outlined above may be summarised as follows. Calculate: 1) the number of lumens incident on the input aperture, 2) the fraction of incident light deflected and undeflected, 3) the transmission of both components to each of the four light pipe apertures, 4) the average workplace illuminance by dividing the lumen output from each aperture by the area of workplace associated with each aperture, 30m 2. The calculations are compared with the average measured values in figure 18 for the four different solar elevations for which measurements were made. Given the simplified theory used the fair agreement between theory and measurement is encouraging.

Comparison between measured values and theorical calculations Lux 500 450 400 350 300 250 200 150 100 50 0 1 2 3 4 Apertures 81º model measurement 81º theory 57º model measurement 57º theory 45º model measurement 45º theory 27º model measurement 27º theory Figure 18: Comparison between measured values and theoretical calculations DISCUSSION The study showed that light pipes coupled with laser cut panels have a good performance for deep plan buildings, reaching illuminance values ranging from 200 to 300 lux over a period from 12pm to 4pm thereby contributing to the 300 lux required for the Water Front House Building. The best performances were obtained for the higher sun angles where the deflected fraction of the incoming light is greater, and is transported through the pipes with fewer reflections. For lower angles the performance diminished as a consequence of the reduction of the light deflected and the increase in the number of reflections suffered by the off axis beam. It appears that the 55º tilt angle of the input LCP is near optimum for a fixed system, however some form of tracking which adjusts the LCP angle could improve the performance of the system. Thus the analysis indicates the use of the light pipes will increase the passive zone in the building and hence reduce energy consumption by the use of daylight, but further study needs to be done in other to obtain a better distribution of the out coming light in the space, and also the integration of the system with electrical light. The design integration may include use of a reflective lighting ceiling in a similar manner to the Johnson Wax building. REFERENCES Baker, N. and Steemers, K. (2000) Energy and environment in architecture: a technical design guide, E&FN Spon, New York. Edmonds, I. R. (1993) Solar Energy Materials and Solar Cells, Performance of laser cut light deflecting panels in daylighting application, 29, 1-26. Edmonds, I. R., Reppel, J. and Jardine, P. (1997) Lighting Res. Technol., Extractors and emitters for light distribution from hollow light guides, 29, 23-32. Yeang, K. (1996) The skyscraper bioclimatically considered: a design primer, Academy Editions, London. Yeang, K. (1999) The green skyscraper: the basis for designing sustainable intensive buildings, Prestel, Munich, Germany London New York. ACKNOWLEDGEMENTS Dr Ken Yeang for his involvement in this project, and Dr Bill Lim for his input into the draft report.