The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

Similar documents
The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1.

The following excerpt are pages from the North American Anchor Fastening Technical Guide, 2011.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

HFX Adhesive Anchor Adhesive Anchoring Systems

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

HLC. Hex head nut with pressed-on washer HLC-H. Bolt version with washer HLC-L. Torx round head HLC-SK. Torx Counter sunk head HLC-EC

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Hilti, Inc South 122 nd East Avenue Tulsa, OK

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Hilti, Inc South 122 nd East Avenue Tulsa, OK

LEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code

DRILL. DRIVE. DONE. EVERYWHERE.

DRILL. DRIVE. DONE. EVERYWHERE.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

PROJECT SUBMITTAL. Power-Stud TM. Wedge Expansion Anchor PROJECT SUBMITTAL CONTENTS APPROVALS AND LISTINGS

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

To: Firm: Project: Product Specified: Specified Location:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Used for Florida State Wide Product Approval #

CHEMICAL /4" 3/8" to 5/8" /8" 3/4" to 1-1/4" 1 10

FROM: PROPOSED SUBSTITUTION: Use HILTI X-U instead of fillet weld or arc spot puddle weld

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Lok-Bolt. Lok-Bolt TM PRODUCT INFORMATION. Sleeve Expansion Anchor FEATURES AND BENEFITS APPROVALS AND LISTINGS GUIDE SPECIFICATIONS.

l MATERIAL SPECIFICATIONS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Trusted ICC ES CONCRETE SECTION: SECTION: 05 HILTI, INC. Look. Conformity! ICC-ES Evaluation

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

Wedge Type Anchors SPECIFIED FOR ANCHORAGE INTO CONCRETE. Trubolt. Wedge Anchor ADVANTAGES

The following excerpt are pages from the Hilti North America Post- Installed Reinforcing Bar Guide.


Power-Bolt PRODUCT INFORMATION. Heavy-Duty Sleeve Anchor PRODUCT DESCRIPTION FEATURES AND BENEFITS. Hex Head Power-Bolt Assembly

the varying quality in existing substrates of older buildings. Be sure to specify the following performance criteria as a minimum.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

hors Anc Eaton's B-Line series fasteners 183

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024

Power-Bolt+ Heavy Duty Sleeve Anchor

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

SPECIFICATION & DESIGN MANUAL " AISI 1060 to 1065 Rockwell Hardness 51 to 55 Perma-Seal coated Stick-E Pin 3/4" (Step Shank) 1"

System Components. Grades. General Information Installation Information

EJOT Chemical Anchoring Systems. High strength anchoring of threaded resin studs into masonry blocks, cracked and non-cracked concrete

Strong Bolt 2 Wedge Anchor for Cracked and Uncracked Concrete

Blue-Tip SCREW-BOLT. Ratchet teeth locks head against fixture. Reverse parabolic threads privide high load capacity

SUPERPLUS M8-M16. The undercut fixing system that does not require a special setting tool. FUNCTION BENEFITS

Dock Bumpers and Support Ledgers Racking and Railing Attachments

R-RBP Rawlbolt - Bolt Projecting for use in cracked and non-cracked concrete

DOMESTIC WEDGE ANCHOR

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT

8.8 M10/15x90 50Nm. Zinc plated. Mechanically galvanised. PSA anchor. heavy duty vibration resistant removable

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

AC100+ GOLD Vinylester Injection Adhesive Anchoring System

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

HVU with HAS/HAS-E rod adhesive anchor system

Dropin TM. Hollow-Set TM PRODUCT INFORMATION. GENERAL APPLICATIONS AND USES Anchoring to Concrete Block Fastening to Precast Hollow Core Plank

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

*Corrected October 2005

Hilti HIT-HY 200-R 500 ml foil pack (also available as 330 ml foil pack) Static mixer

Declaration of Performance No. DPGEB1006 v2.1

Spike F A S T E N E R S

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

CITY OF LOS ANGELES CALIFORNIA

SINGLE ANCHOR USE FOR NON-CRACKED CONCRETE

DESCRIPTION ADVANTAGES

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

A7+ The Most Versatile Quick Cure Adhesive

R-RBP Rawlbolt - Bolt Projecting for use in cracked and non-cracked concrete.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

HRD-U 10 / - S 10 / -U 14 Frame anchor

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW BUILDEX 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

HKD Push-in anchor, Single anchor application

Trusted ICC ES HILTI, INC. SYSTEM E ANCHOR. Conformity! Look. Evaluation. ICC-ES Evaluation

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

Transcription:

The following excerpt are pages from the North merican Product Technical Guide, Volume 2: nchor Fastening, Edition 17. Please refer to the publication in its entirety for complete details on this product including data development, product specifications, general suitability, installation, corrosion and spacing and edge distance guidelines. US: http://submittals.us.hilti.com/ptgvol2/ C: http://submittals.us.hilti.com/ptgvol2c/ To consult directly with a team member regarding our fastening products, contact Hilti s team of technical support specialists between the hours of 7:00am 6:00pm CST. US: 877-749-6337 or HNTechnicalServices@hilti.com C: 1-800-363-4458, ext. 6 or CTechnicalServices@hilti.com Hilti, Inc. 7250 Dallas Parkway, Suite 1000 Plano, TX 75024 1-800-879-8000 www.hilti.com

Mechanical nchoring Systems 3.3.14 HLC Sleeve nchor 3.3.14.1 Product description 3.3.14.2 Material specifications 3.3.14.3 Technical data 3.3.14.4 Installation instructions 3.3.14.5 Ordering information 3.3.14.1 Product description HLC sleeve s are mechanical expansion s consisting of an externally thread stud or bolt, expansion cone and expanding sleeve. It is designed for age to concrete, hollow masonry, solid masonry and brick. Product features nchor suitable for through-hole installation nchor and masonry bit are the same Good selection of s, lengths and head configurations offer versatility Load data for concrete, hollow masonry, solid masonry and brick Extrusions on sleeve prevent the from spinning in hole during installation or dropping out of overhead hole prior to applying installation torque. Guide specifications Expansion s Carbon steel sleeve s are zinc plated in accordance with STM B633, SC 1, Type III. Stainless steel sleeve s manufactured from ISI Type 304 stainless steel. Expansion nchors shall be HLC sleeve s supplied by Hilti. 3.3.14.2 Material specifications Carbon steel expansion sleeves and spacer sleeves are manufactured from cold rolled steel. Carbon steel s are zinc plated in accordance with STM B633, SC 1, Type III. Stainless steel components are manufactured from ISI Type 304 stainless steel. Bolt Head (HLC-H) Hex Nut HLC-HX Flat Phillips Head HLC-FPH Tie-Wire Head HLC-T corn Nut HLC-C 3.3.14.3 Technical data Table 1- Hilti HLC Sleeve nchor specification table Setting information Symbol 1/4 5/16 3/8 1/2 5/8 3/4 Thread size UNC in. 3/16-24 1/4-20 5/16-18 3/8-16 1/2-13 5/8-11 d bit in. 1/4 5/16 3/8 1/2 5/8 3/4 nominal h nom in. 1 1 1-1/4 1 1/2 2 2 (mm) (25) (25) (32) (38) (51) (51) in. 1-3/8 1-3/8 1-3/4 2-1/8 2-5/8 2-5/8 hole depth h o (mm) (35) (35) (45) (54) (67) (67) ft-lb 12 18 35 1 T inst (Nm) (16) (24) (47) Installation torque ft-lb 2 5 10 15 60 90 2 T inst (Nm) (3) (7) (14) ((20) (81) (122) 1 HLC-H Bolt Head model 2 HLC-HX, HLC-FPH, HLC-C, HLC-RS and HLC-RC models. Combined shear and tension loading N 5/3 d V 5/3 d + 1.0 ( N rec ) ( V rec ) Round Head Slotted HLC-RS Rod Coupling HLC-RC 406 Hilti, Inc. (US) 1-800-879-8000 www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I nchor Fastening Technical Guide Ed. 17

Table 2 - Carbon steel sleeve allowable loads in concrete 1 Bolt in. Mechanical nchoring Systems HLC Sleeve nchor 3.3.14 ƒ' c = 2,000 psi ƒ' c = 4,000 psi ƒ' c = 6,000 psi Tension Shear 2 Tension Shear 2 Tension Shear 2 in. (mm) lb (kn) lb (kn) lb (kn) lb (kn) lb (kn) lb (kn) 1/4 3/16 1 (25) 225 (1.0) 305 (1.4) 250 (1.1) 305 (1.4) 250 (1.1) 305 (1.4) 5/16 1/4 1 (25) 350 (1.5) 560 (2.5) 450 (2.0) 560 (2.5) 500 (2.2) 560 (2.5) 3/8 5/16 1-1/4 (32) 450 (2.0) 870 (3.9) 565 (2.5) 870 (3.9) 700 (3.1) 890 (4.4) 1/2 3/8 1-1/2 (38) 675 (3.0) 1,250 (5.6) 925 (4.1) 1,325 (5.9) 1,100 (4.9) 1,325 (5.9) 5/8 1/2 2 (51) 1,035 (4.6) 1,750 (7.8) 1,500 (6.7) 2,295 (10.2) 1,950 (8.7) 2,295 (10.2) 3/4 5/8 2 (51) 1,125 (5.0) 1,750 (7.8) 1,500 (6.7) 3,000 (13.3) 1,950 (8.7) 3,010 (13.4) 1 Based on a safety factor of 4.0. 2 For 1/4- and 3/8-in. flat phillips and round head s, shear values should be reduced by 57% due to the potential of the shear acting through the hollow portion of the head. Table 3 - Stainless steel sleeve allowable loads 1 ƒ' c = 2,000 psi ƒ' c = 4,000 psi Hollow C-90 concrete block 2 Tension Shear Tension Shear Tension Shear in. (mm) lb (kn) lb (kn) lb (kn) lb (kn) lb (kn) lb (kn) 1/4 1-1/8 (29) 235 (1.0) 450 (2.0) 300 (1.3) 450 (2.0) 200 (0.9) 400 (1.8) 5/16 1-1/4 (32) 310 (1.4) 675 (3.0) 410 (1.8) 675 (3.0) 335 (1.5) 600 (2.7) 3/8 1-1/2 (38) 450 (2.0) 1,000 (4.4) 600 (2.7) 1,000 (4.4) 470 (2.1) 890 (4.0) 2 STM Specification C90, Type II. Table 4 - Carbon steel sleeve allowable loads in grout-filled block 1,2,3,4,5,6,7 Edge distance Tension Shear in. (mm) in. (mm) lb (kn) lb (kn) 1/4 1 (25) 290 (1.3) 305 (1.4) 5/16 1 (25) 385 (1.7) 500 (2.2) 3/8 1-1/4 (32) 435 (1.9) 725 (3.2) 1/2 1-1/2 (38) 865 (3.8) 605 (2.7) 1,145 (5.1) 5/8 2 (51) 1,050 (4.7) 710 (3.2) 1,815 (8.1) 3/4 2 (51) 1,050 (4.7) 840 (3.7) 1,970 (8.8) 1 Values are for lightweight, medium-weight or normal-weight concrete masonry units conforming to STM C90 with 2,000 psi grout conforming to STM C474. 2 Embedment depth is measured from the outside face of the concrete masonry unit. 3 Values are for s located in the grouted cell, bed joint, cross web or any combination of the above. 4 For s installed in the T joint or head joint reduce tension values by 20%. 5 Values for edge distances between 4 inches and 12 inches may be calculated by linear interpolation. 6 nchors are limited to one per unit cell. 7 Based on using a safety factor of 4. Table 5 - Carbon steel sleeve allowable loads in hollow concrete block 1,2,3,4 nchor Diameter Tension Shear in. (mm) lb (kn) lb (kn) 1/4 1 (25) 350 (1.5) 305 (1.4) 5/16 1 (25) 375 (1.7) 560 (2.5) 3/8 1-1/4 (32) 435 (1.9) 800 (3.5) 1/2 1-1/2 (38) 565 (2.5) 1,125 (5.0) 2 STM Specification C90, Type II. 3 Installation in the mortar joints is outside the scope of the published data. 4 nchors are limited to one per unit cell with a minimum edge distance of 12 inches. Table 6 - Carbon steel sleeve allowable loads in clay brick 1,2,3,4 nchor Diameter Tension Shear in. (mm) lb (kn) lb (kn) 1/4 1 (25) 350 (1.5) 305 (1.4) 5/16 1 (25) 345 (1.5) 530 (2.3) 3/8 1-1/4 (32) 375 (1.7) 850 (3.8) 1/2 1-1/2 (38) 435 (1.9) 1,230 (5.5) 2 Due to wide strength variations encountered in masonry, these values should be considered as guide values. 3 Installation in the mortar joints is outside the scope of the published data. 4 spacing shall be two (2) complete bricks in any direction. edge distance shall be the lesser of two (2) complete bricks or 16 inches in any direction. 3.3.14 Hilti, Inc. (US) 1-800-879-8000 www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I nchor Fastening Technical Guide Ed. 17 407

Mechanical nchoring Systems 3.3.14 HLC Sleeve nchor 3.3.14.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.hilti.com. Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.14.5 Ordering information 1 Round head slotted (RS) HLC-RS 1/4 x 1-1/4 1/4 3/16-24 1 1/4 100 HLC-RS 1/4 x 2 1/4 3/16-24 1 1 100 HLC-RS 1/4 x 4 1/4 3/16-24 1 3 100 Bolt head (H) HLC-H 5/16 x 1-5/8 5/16 1/4-20 1 5/8 100 HLC-H 5/16 x 2-5/8 5/16 1/4-20 1 1-5/8 100 HLC-H 3/8 x 1-7/8 3/8 5/16-18 1-1/4 5/8 50 HLC-H 3/8 x 3 3/8 5/16-18 1-1/4 1-3/4 50 HLC-H 1/2 x 2-1/4 1/2 3/8-16 1-1/2 3/4 50 HLC-H 1/2 x 3 1/2 3/8-16 1-1/2 1-1/2 25 HLC-H 1/2 x 4 1/2 3/8-16 1-1/2 2-1/2 25 Flat phillips head (FPH) HLC-FPH 1/4 x 1-3/8 1/4 3/16-24 1 3/8 100 HLC-FPH 1/4 x 2 1/4 3/16-24 1 1 100 HLC-FPH 1/4 x 3 1/4 3/16-24 1 2 100 HLC-FPH 1/4 x 4 1/4 3/16-24 1 3 100 HLC-FPH 3/8 x 2-7/8 3/8 5/16-18 1-1/4 1-1/2 50 HLC-FPH 3/8 x 4 3/8 5/16-18 1-1/4 2-3/4 50 HLC-FPH 3/8 x 5 3/8 5/16-18 1-1/4 3-3/4 25 HLC-FPH 3/8 x 6 3/8 5/16-18 1-1/4 4-3/4 25 1 ll dimensions in inches Definition of nomenclature Outside of sleeve, see tables for threaded bolt HLC-C 1/4 X 1-3/8 Nut configuration The overall length from bottom of washer to end of sleeve 408 Hilti, Inc. (US) 1-800-879-8000 www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I nchor Fastening Technical Guide Ed. 17

Mechanical nchoring Systems HLC Sleeve nchor 3.3.14 Hex nut (HX) HLC-HX 5/16 x 1-5/8 5/16 1/4-20 1 1/2 100 HLC-HX 5/16 x 2-5/8 5/16 1/4-20 1 1-1/2 100 HLC-HX 3/8 x 1-7/8 3/8 5/16-18 1-1/4 5/8 50 HLC-HX 3/8 x 3 3/8 5/16-18 1-1/4 1-3/4 50 HLC-HX 1/2 x 2-1/4 1/2 3/8-16 1-1/2 3/4 25 HLC-HX 1/2 x 3 1/2 3/8-16 1-1/2 1-1/2 25 HLC-HX 1/2 x 4 1/2 3/8-16 1-1/2 2-1/2 25 HLC-HX 1/2 x 6 1/2 3/8-16 1-1/2 4-1/2 15 HLC-HX 5/8 x 2-1/4 5/8 1/2-13 2 1/4 25 HLC-HX 5/8 x 4-1/4 5/8 1/2-13 2 2-1/4 10 HLC-HX 5/8 x 6 5/8 1/2-13 2 4 10 HLC-HX 3/4 x 2-1/2 3/4 5/8-11 2 1/2 10 HLC-HX 3/4 x 4-1/4 3/4 5/8-11 2 1-3/4 10 HLC-HX 3/4 x 6-1/4 3/4 5/8-11 2 3-3/4 10 corn head (C) HLC-C 1/4 x 1-3/8 1/4 3/16-24 1 3/8 100 HLC-C 1/4 x 2-1/4 1/4 3/16-24 1 1-1/4 100 304SS sleeve s HLC-HX 304SS 1/4 x 2-1/4 1/4 3/16-24 1-1/8 1-1/8 100 HLC-HX 304SS 5/16 x 1-1/2 5/16 1/4-20 1-1/4 1/4 100 HLC-HX 304SS 5/16 x 2-1/2 5/16 1/4-20 1-1/4 1-1/4 100 HLC-HX 304SS 3/8 x 1-7/8 3/8 5/16-18 1-1/2 3/8 50 HLC-HX 304SS 3/8 x 3 3/8 5/16-18 1-1/2 1-1/2 50 Rod coupling (RC) 3.3.14 HLC-RC 3/8 x 1-7/8 3/8 5/16-18 1-1/4 5/16 x 3/8 50 HLC-RC 1/2 x 2-1/4 1/2 3/8-16 1-1/2 3/8 x 1/2 25 Tie-wire head (T) Definition of nomenclature Outside of sleeve, see tablesfor threaded bolt HLC-C 1/4 X 1-3/8 HLC-T 1/4 x 1-3/8 1/4" 3/16-24 1-3/8 50 1 ll dimensions in inches Nut configuration The overall length from bottom of washer to end of sleeve Hilti, Inc. (US) 1-800-879-8000 www.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.com I nchor Fastening Technical Guide Ed. 17 409