HYDROGEN H2 SS SOLID ELECTROCHEMICAL SENSOR

Similar documents
Nemoto Sensor Engineering Company Ltd

Nemoto Sensor Engineering Company Ltd

ME2-CO Electrochemical Carbon Monoxide sensor with UL certificate. Manual. (Model:ME2-CO) Zhengzhou Winsen Electronics Technology Co.

Contents Principles of Operation General Specifications... 4 Outline Drawing and construction.. 5 Performance Measurements. 6 Gas Sensitivity/Li

Recommended Land Pattern: [mm]

I. INTRODUCTION. II. OBJECTIVE OF THE EXPERIMENT. III. THEORY

Sensor unit MC2 for toxic gases and oxygen with analog output

SP3S-AQ2-01 AIR QUALITY SENSOR S March, 2004

RESP_IRR_20 P Package

Applications. Capacitance Code Version. The last two digits represent significant figures. The first digit specifies the total number of digits.

Characteristic and efficiency of PEM fuel cell and PEM electrolyser

Why Does Rust Occur? 7.1 IN GENERAL

CO2 transmitters. Introduction 44. CO 2 transmitters 45. CO 2 and temperature transmitters 46. CO 2 transmitters for special applications 47-48

Electricity. Characteristic and efficiency of PEM fuel cell and PEM electrolyser Stationary currents. What you need:

REDOX AND REFERENCE ELECTRODE USER MANUAL

What is Electrochemical Migration Dendrite Shorting of Electronic Circuits?

Electrolysis, electrode polarisation, decomposition voltage, galvanic elements, Faraday s law.

Continuous Gas Measurements Greater Measuring Accuracy Lower Maintenance Costs Reliable Measurement. From ENOTEC

Application Information Chemical Exposure of Devices Introduction Reducing the Potential of Corrosion Non-Hermetic Epoxy Packages

bans the use of lead, mercury, cadmium, hexavalent chromium and polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).

Sensor Technologies used in Portable Gas Monitors. HA University

Midterm Exam. on your way out. Sign - in. Pick up the TAKEHOME Midterm. Complete by Wednesday 8:30am. Turn in beginning of class Wednesday

Extended Life Tantalum Hybrid Capacitor

LA PD120HP1. Premium Edition Standard PIN photodiode 120 mil

20 W Power Resistor, Thick Film Technology, TO-220

Material/Product Safety Data Sheet (MSDS-PSDS)

Quality and Reliability Report

MS763 Pressure Sensor Die (0-300 mmhg)

Process Variables. Process Variables. Temperature Strain Level Flow Pressure

Extracting Metals by Reduction

Optical DO Whitepaper: Technology

Process Electrodes and Probes

O N T H E Q U A L I T Y L I N E PERMEABILITY TESTING: THE CHALLENGES AND SOLUTIONS

HBLED packaging is becoming one of the new, high

Sensor Cartridge SC2 for toxic gases and oxygen

Sensor Cartridge SC2 for toxic gases and oxygen

CPC1967J. i4-pac Power Relay INTEGRATED CIRCUITS DIVISION. Description. Characteristics. Features. Applications. Ordering Information

CPC1908. Single-Pole, Normally Open i4-pac Power Relay INTEGRATED CIRCUITS DIVISION. Description. Characteristics. Features.

The MiCS-4514 is a compact MOS sensor with two fully independent sensing elements on one package.

LMM-H04 Mass Air Flow Sensor

What is ph? ph is the measurement of the Hydrogen Ion concentration in a particular solution. Indicates the Acidity or Alkalinity of a solution.

Materials are all substances and include metals, ceramics and plastics as well as natural and new substances.

Gas Analyzer Spare Part Recommendations

Model LMM-H03 Mass Air Flow Sensor

DATA SHEET. 1. Scope of Application This data sheet is applied to the LED package, model CLL C1-28GV1J4.

HT829 Humidity Transmitter HT839 Humidity and Temperature Transmitter Installation and Operating Instructions

an ISO9001/14001 company

REDOX AND REFERENCE ELECTRODE USER MANUAL

Mark schemes. for 1 mark. for 1 mark. An arrow indicating a position between aluminium and zinc. electrolysis

an ISO9001 company TECHNICAL INFORMATION FOR TGS2600 Technical Information for Air Quality Control Sensors

an ISO9001/14001 company

Portable Humidity Solutions

Portable Instruments. Fast, accurate and stable measurements in the most demanding industrial environments.

H2scan Market Overview

MFM Metal Film MELF Resistor

CFL Series User Manual

3M Anisotropic Conductive Film 5363

Spotlight on Photovoltaics & Fuel Cells: A Web-based Study & Comparison (Teacher Notes)

Development of microsensors for chloride concentration in concrete

Degassed Cation Conductivity

Fluxless soldering using Electron Attachment (EA) Technology

Automotive gas sensors. Christophe PIJOLAT, Ecole des Mines de St-Etienne, France

Quality and Reliability Report

Metallization deposition and etching. Material mainly taken from Campbell, UCCS

3M Anisotropic Conductive Film (for Touch Screen Panel)

Model LMM-H03 Mass Air Flow Sensor

General Introduction to Microstructure Technology p. 1 What is Microstructure Technology? p. 1 From Microstructure Technology to Microsystems

H-100 Fuel Cell Stack User Manual

H-300 Fuel Cell Stack User Manual

LA WW40WP6. Premium Edition Warm White 40 mil

MICRO FUEL CELLS for MOBILE POWER Thermal Management in Fuel Cells

Enhanced Water Vapour Permeability Tester for High Barrier Materials. Alyce Hartvigsen, PBI Dansensor A/S, Ringsted, Denmark

Topic 9 National 4 Chemistry Summary Notes. Metals and Alloys. Materials

2 of 13 pages Directory 1. Outline Drawing 3/13 2. Features 3/13 3. Typical Applications 3/13 4. Specifications 3/13 5. Capacitor series code informat

GasLab SAN-100 Micro Carbon Monoxide Monitor User Manual

CORROSION of Metals CORROSION CORROSION. Outline ISSUES TO ADDRESS... Why does corrosion occur? What metals are most likely to corrode?

an ISO9001 company TECHNICAL INFORMATION FOR TGS2602 Technical Information for Air Quality Control Sensors

Note Fabrication of Flexible Micro CO Sensor for Proton Exchange Membrane Fuel Cell Applications

Quality in Electronic Production has a Name: Viscom. System Overview

DATA SHEET CLL B2-353M1C5

Dynamic and Cooler. Duet F200. Best Lumen / Watt Plant Growth COB Module

DATA SHEET CLL B2-50CM1A2

Compact Electro Plating Machine - CEPM-2A USER MANUAL

DESCRIPTION STANDARD RANGES

Thin Film Circuit Substrate(RUSUB TM )

SERIES 60 DETECTORS-TRANSMITTERS FOR FLAMMABLE, TOXIC GASES AND OXYGEN ATEX. Your environment, your safety, let s master them together

CHEQUERS ELECTRONIC (CHINA) LIMITED. Quartz Crystal Oscillator Specification

VpCI PROTECTION SYSTEM FOR ELECTRICAL/ ELECTRONIC ENCLOSURES

1.6mm Round Subminiature Reverse Package Phototransistor PT26-21C/TR8

INTENSITY CODES TECHNICAL. INTENSITY CODES. Intensity Code for Standard LEDs (Ta=25 C Tolerance +/-15%)

Power Resistor for Mounting onto a Heatsink Thick Film Technology

P21 WHITE PAPER FUNCTIONAL DESCRIPTION PREMION T FUEL CELL SYSTEM. Copyright 2006 P21 GmbH. All rights reserved.

Chlorine Dioxide Amperometric 4-20mA Sensors

Transcription:

1. Description of Technology The Hydrogen Sensor is based on the electrochemical gas detection principle. This technology can be used to detect chemicals or gases that can be oxidised or reduced in chemical reactions. Hydrogen: The following reaction takes place when Hydrogen diffuses into the sensor: H 2 diffuses into the working electrode, which holds free places for Hydrogen molecules. At the point where the Hydrogen and Electrolyte mix, H 2 will break up into 2H+ and 2 electrons. The amount of electrons (Current) is directly proportional to the concentration of Hydrogen. Protons (H+) move through the electrolyte to the Counter Electrode where H+ and Oxygen form water. The Reference Electrode is isolated and maintains the base potential to stabilise the sensor output, even when the sensor is exposed to high concentrations of Hydrogen. Three electrode sensors have a wider detection range with good direct linearity. Oxygen is not required for the chemical reaction but this does not mean that the sensor can work in environments without Oxygen. An atmosphere without Oxygen will cause the free Oxygen inside the electrolyte to disappear slowly. This process absorbs only the Hydrogen and since the H 2 is the fuel for the reaction, the life expectancy of the sensor is over five years. 2. Design Raw Sensor Dimensions: 8.8 mm 10 mm Size: 8mm wide x 10mm high x 1mm thick. Contact separation: 2.5mm between pads Contact size: 2mm x 1mm. Material: Gold - can be soldered or bonded 2.5 mm

Operation: H 2 GAS Gas enters through a diffusion and protection filter from the back. This filter protects the sensor from dust and water, allowing the gas to flow through. It is nearly impossible to keep gas from entering into the sensor unless the filter is completely blocked. Composition: The left electrode is the Reference electrode (R). The middle electrode is the Measurement Electrode (M). The right electrode is the Counter Electrode (C). The final layers are electrolyte and a protective skin. R M C A RAW single sensor is part of a wafer which contains 48 RAW Sensors. Single RAW sensors or a complete wafer can be purchased. Every wafer is gas tested prior to shipment. The sensors are separated through pre-manufactured break lines as shown on the illustration below. If ordering a wafer of 48 RAW sensors, it is important to break the sensors away from the wafer in the following order. The separation process is very easy if this order is followed: 1. Break the wafer at the RED lines first. It is not important which one is used first. 2. Next break the wafer at the GREEN lines.

3. DIFFERENCES TO STANDARD S a) Acid electrolyte like H 2 SO 4 is replaced by a solid electrolyte. What happens with the previous system? Standard sensors require a sealed housing to protect the surrounding from the aggressive acidic electrolyte. As acid takes in and releases water, there is a risk of leakage in humid atmospheres or a drying out effect in dry atmospheres. Therefore, the biggest part of such a sensor is a reservoir for the acid electrolyte. Acid based sensors are therefore larger due to the need for a large electrolyte reservoir. There is a potential for damage to electronic circuits should the sensor leak. Production of acid based sensors is complicated. Acid is dangerous. Benefits of the new system: The solid electrolyte is not dangerous and much easier to handle. No housing is needed. No reservoir is needed. The reading is very fast and promptly reacts to gas leaks in the environment. Adjustment to humidity and temperature variation is immediate. b) Plastic housing is not required - the sensor is built on a ceramic wafer. What does this mean in the old system? Plastic housing needed to be sealed or glued together. Acid and change of temperature may cause damage to the plastic over time. Sensor construction is more complex, with contacts and pins connected via wires to the electrodes through the housing. The process is risky and can reduce sensor life and quality. Benefits of the new system: Sensors can be produced in parallel in one production step. Ceramic electrodes and electrolytes can be built up in layers. Production is fully automated, increasing quality and stability. c) Differences in connection What happens with the old system? Electrodes are produced separately. The connection is made with a platinum wire, which needs to be connected to contact pins. Contact pins must be protected from the acid electrolyte. Benefits of the new system: The wire and the electrode are printed on layers. The last layer is gold, which can be soldered to directly.

3. Temperature and Humidity Dependence Temperature dependence differs from the common electrochemical sensor. Normally temperature changes also cause changes in relative humidity in ambient air. Solid electrolyte sensors adjust immediately to humidity changes and will adapt to the new temperature in minutes. All materials used for the H 2 sensors are suitable for use in temperatures up to 80 o C and down to -20 o C. However, 80 o C and very dry air reduce the humidity inside the electrolyte and may result in less sensitivity.

The standard humidity range for the solid electrolyte sensor is between 15% RH and 90% RH noncondensing. Water drops cannot block the diffusion opening but may cause a momentary change in the behaviour of the sensor. The graph below shows no change in the sensor output when the humidity changes from 15% RH to 90% RH at minute 30. The spike is a result of a high gas concentration during mass flow adjustments from dry air to wet air. The gas concentration was 1300ppm H 2 and the test was conducted at room temperature of ~23 o C. There is a drop of signal during the first 10 minutes due to stabilisation to the dry air. The switch to 90% RH shows no change. The red line at 1µA represents a standard electrochemical style sensor used for reference. These types of sensors will not normally show a large change due to different humidity caused internally by the acid reservoir. They will dry out very slowly but consistently. If they dry out completely, the sensors will no longer react to gas. Our solid electrolyte sensor may change behaviour but it will quickly adapt to the changed environment. In addition, it will not show further drying out problems.

4. Lifetime of the Hydrogen Sensor The Sensor is made of materials that do not have a limited lifetime. There is no poisoning from silicon materials and no consumable materials. Due to the long lasting materials used for the construction of the sensors, aging is not a significant factor. The sensor warranty is 2 years from despatch of order, which is soon to be extended. 5. Sensitivity and Response Time From newest Sensor Generation The latest revision has a much bigger dynamic range and performs faster than the prior generation. The graph below shows sensors from a production run from December 2008. The revision level can be identified from the gold contacts and the hole on the counter electrode. NOTE: The red sensor with no. 999 at 3µA is the reference sensor and the first six were sealed and protected sensors.

6. SENSOR OPTIONS AND HOUSING The H 2 SS is available in different options. The sensor can be purchased as Raw, Micro and 4 Series sensors or with integrated circuitry: RAW sensor Micro sensor 5V transmitter part no. 2112B010210 part no. 2112B012710 part no. 2112B013410 For standard pin requirements, the H 2 SS sensor is available as a standard 4 series size sensor with 3 pins: 4 Series part no. 2112B010410 For H 2 transmitter and housing requirements, there are different options available: H 2 SS 4-20mA or 1-4Vdc transmitter including Raw sensor: H 2 SS Gas measuring system in aluminium housing: part no. 2112B24421 part no 2112B24420 The data contained in this document is believed to be accurate and reliable. The data given is for guidance only. Euro-Gas Management Services Ltd accepts no liability for any consequential losses, injury or damage resulting from the use of this datasheet or the information contained in it. Customers should test the sensors under their own conditions to ensure that the sensors are suitable for their own requirements and in accordance with the plans and circumstances of the specific project and any standards/regulations pertaining to the country in which the sensors will be utilised. This datasheet is not intended to form the basis of a contract and in the interest of product improvement, Euro-Gas reserves the right to alter design features and specifications without notice. 01/13