ARIS D 5.2 Evaluierungsbericht

Similar documents
Getting Started with Your First Project: Considering Rules

Commercial Building Performance Evaluation System for HVAC Diagnostics and Commissioning

Meeting the Variable Needs of Energy- Efficient Mechanical Ventilation When and Where You Need It

Demand controlled ventilation (DCV) for better IAQ and Energy Efficiency

A MODEL-BASED METHOD FOR THE INTEGRATION OF NATURAL VENTILATION IN INDOOR CLIMATE SYSTEMS OPERATION

Setback efficiency of limited-power heating systems in cold climate

Trane VRF. variable refrigerant systems

Why use VSD in existing HVAC installations

INNOVATIONS IN VENTILATION TECHNOLOGY 21ST ANNUAL INTERNATIONAL AIVC CONFERENCE THE HAGUE, NETHERLANDS, SEPTEMBER 2000

Voyager kw rooftop units Plug and Play comfort in commercial applications

Load Management with Ripple Control Technology

The energy benefits of View Dynamic Glass

PRODUCTIVITY AND SICK LEAVE INTEGRATED INTO BUILDING PERFORMANCE SIMULATION. Wim Plokker and Aad Wijsman Vabi Software bv, Delft, The Netherlands

201 Charlotte Street, Brisbane, Queensland

Energy savings in commercial refrigeration. Low pressure control

Energy Efficiency. best in class

Traffic insights ATSPM Flashcards

Opportunities and Limitations of Building Precooling

Work Package 2: Performance of naturally ventilated buildings

More is Better? Analyzing the Relation between Metering Duration and Accuracy of Results for Residential Lighting Evaluations

Slagging Mitigation Executive Summary

Smart Personal Environment Regulator

Energy efficient ventilation systems

Higher National Unit Specification. General information for centres. Building Management Systems. Unit code: DP0Y 34

Ventilation. Demand-controlled ventilation (DCV) Demand-Controlled. With ASHRAE Standard Based

Context-Aware Energy Efficiency in Smart Buildings

Testing of a Tracer Gas Based Measurement Procedure to Assess Air Change Rates in Buildings

FCR prequalification design note

Guide to Using the SegenSolar Battery Calculator

Building Controls Strategies Conference. Retro-Commissioning with BAS Overview. 10 March Steve Brown, CAP ESD Controls Team Leader

Chilled Water System Optimization

V entilation control using carbon dioxide

Biberach University of Applied Sciences Institute for Building and Energy Systems

Operations and Supply Chain Management Prof. G. Srinivasan Department of Management Studies Indian Institute of Technology, Madras

CHILLED WATER SYSTEM OPTIMIZER

Characteristics of Energy Consumption by building type of a U.S. Navy Installation in Hot and Humid Climate

Load Management System Optimization For Northern Virginia Electric Cooperative (NOVEC)

UNIT HYDROGRAPH AND EFFECTIVE RAINFALL S INFLUENCE OVER THE STORM RUNOFF HYDROGRAPH

Optimizing Buildings Using Analytics and Engineering Expertise

A Systematic Approach to Performance Evaluation

Achieving Near Net-Zero Energy Usage in Laboratory

Coincidence Factor Study Residential and Commercial & Industrial Lighting Measures. Prepared for; New England State Program Working Group (SPWG)

PRODUCTS SOLAR PLEXICON PRODUCT: ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

ENSURING IDEAL PORT UTILIZATION ON AVAYA AURA EXPERIENCE PORTAL WHITE PAPER

CASE STUDY OF APPLYING DIFFERENT ENERGY USE MODELING METHODS TO AN EXISTING BUILDING

Forecast based energy management for trigeneration subnets in smart grids

Improving the efficiency, occupant comfort, and financial well-being of campus buildings

Performance Analysis of Hotel Lighting Control System

STATISTICAL TECHNIQUES. Data Analysis and Modelling

Introduction to Simulink & Stateflow

Methane emission from naturally ventilated livestock buildings can be determined from gas concentration measurements

PID Aeration Control

Example graphs. Features: System data Component data Hierarchies Hierarchy data links Comment (about function) Status

Energy Toolkit How to guide. Analysis. Helpingourcustomers. We reonit.

Model-based control through co-simulation for intelligent Building Energy Management Systems design

Trane Water-Source Variable Refrigerant Flow

OUR EXPERIENCE WITH RCX SOFTWARE: TRIUMPHS AND CHALLENGES

You Can t Afford Discomfort. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

In the last few years, the concerns about global

CHAPTER 8 PERFORMANCE APPRAISAL OF A TRAINING PROGRAMME 8.1. INTRODUCTION

Field Commander. Overview. Operations. Custom Solution. Building Startup/Shutdown

Fundamentals of Test & Balance for Engineers, Cx & Energy Providers Course Number: CXENERGY1619

Demand-Controlled Ventilation: A Design Guide

Constant Temperature Lab Equipment and Thermoelectric Technology

Building Retro-Commissioning

The impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, 2009 All Rights Reserved

KNX-based Energy Efficient Heating and Lighting in Educational Buildings

Teague Research Center

Energy Modeling Applications for Existing Buildings

Optimizing BAS Information for Operator Effectiveness and Optimal Control

TDWI strives to provide course books that are contentrich and that serve as useful reference documents after a class has ended.

HC900 Hybrid Controller When you need more than just discrete control

The future of outbound is Precision Dialling How to optimise your outbound contact activities

OUTSIDE AIR REDUCTIONS

Integration of Controls

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

The nzeb as the active element of an energy system 20 months of operation!

A Simulation-based Control Approach in a Mechanical Ventilation. System

ABB Cement Fingerprint Holistic Approach for Cement Industries

The impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, plc, All Rights Reserved

Optimal Light Integral and Carbon Dioxide Concentration Combinations for Lettuce in Ventilated Greenhouses

P. Rohdin 1, M. Johansson 2, J. Löfberg 3, M. Ottosson 4. Abstract

Featherston Groundwater Infiltration Investigation

FIRST LARGE-SCALE SOLAR SEASONAL BOREHOLE THERMAL ENERGY STORAGE IN CANADA

Acutherm was spec d here. Building Automation Guide for Therma-Fuser Systems

The Building Systems Detective

The future of outbound is precision dialling How to optimise your outbound contact activities

RE<C: Brayton System Performance Summary

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

Building Management Systems for Building Services Engineering

WebCTRL BUILDING ANALYTICS

Knowledge is Power Belimo Energy Valve CHW DELTA T MITIGATION STUDY AHR Expo Innovation Award Winner in the Category of Building Automation

Level II - Whole Building Interval Electric Data with Tenant Plug Load System

DEVELOPMENT OF DYNAMIC SIMULATION MODEL FOR BUILDING ENERGY MANAGEMENT SYSTEMS.

Occupancy-Based Control of Indoor Air Ventilation: A Theoretical and Experimental Study

Karl Helmink, P.E., CEM Retrocommissioning Manager University of Illinois. Retrocommissioning Saving the Planet One Building at a Time

NOVEC Project Proposal

USING A LARGE RESERVOIR MODEL IN THE PROBABILISTIC ASSESSMENT OF FIELD MANAGEMENT STRATEGIES

Transcription:

ARIS D 5.2 Evaluierungsbericht Projekt Referenz FFG Projekt Nr. 845143 Projekt Akronym Projekt Titel Programm Ausschreibung ARIS Anwendung nichtlinearer Regelungstechnik und intelligenter Sensorik zur Effizienzsteigerung in Gebäuden ENERGIE DER ZUKUNFT SdZ 1. Ausschreibung 1

Table of Contents 1 Introduction 3 2 HIL-Run ENERGYbase 3 2.1 Data collection 3 2.2 Ventilation system model 3 2.3 Predictive optimization controller 3 2.4 Analysis 3 3 E+E Office Building 9 2

1 Introduction The present deliverable illustrates the results from the EnergyBase field test. The ventilation system that feeds fresh air into the seminar rooms from the Fachhochschule was actuated on the basis of a model based energy management. The goal was to improve the overall air quality while taking the energy consumption for the actuation of the whole process into further consideration. A survey was conducted to gather information from the students that were present in the seminar rooms that day. 2 HIL-Run ENERGYbase On December 2, 2016 a field test has been performed in the ENERGYbase building. The goal of the test was to validate the behavior of developed components, and to test drive the predictive controller in the human-in-the-loop mode. The field test had to be operated partly manually, since a coupling of the controller with the supervisory control system proved unfeasible and would have required significant refurbishment of the ventilation system controller, which was not foreseen. The approach therefore was to let the controller run using the acquired data for volume flows, pressure and CO2 levels and calculate the setpoints for the volume flows of the rooms. These volume flows then had to be entered manually into the supervisory control system. In the test the building ventilation system model (pressure drop model), the predictive controller and the virtual occupancy sensor were validated. The experiment was performed between 8:00 and 16:00h, on a workday, when, based on the FH Technikum room scheduling, it was estimated that the space usage will be as usual for the duration of the experiment. 2.1 Data collection All the data is collected in a database that was set up by partner AutomationX. The indoor parameters are directly recorded from the BACnet datapoints and provided to the controller. Furthermore they are stored in the database for further analysis. 2.2 Ventilation system model The ventilation system of the building has been modeled as described in Deliverable 4.1 and 4.2 in the MATLAB-based system created by AIT. Also the CO2 room models are provided in MATLAB, and the models are all executed in the same framework in which the controller operates. 2.3 Predictive optimization controller Predictive optimization model is configured to maintain the CO2 concentration below the set point. This is accomplished by actively balancing the system based on the current and forecasted CO2 generation in rooms. CO2 forecast is generated using the provided lecture schedules and norms for CO2 emissions from people based on the activities they are performing. System is balanced in such a way as to have at least one variable air volume (VAV) controller fully open at all times. Ideally, control parameters are VAV controller settings (volume of air in time unit for each of the rooms) and the main fan air pressure. In our experiment, the main fan pressure was considered fixed. However, one manual change has been made to the pressure when it seemed that the actual pressure at the time wasn t high enough to provide sufficient flow to the whole system. 2.4 Analysis Figures 1 to 5 shows the combined graph with measured CO2 value and CO2 set point, required and provided fresh airflow volume on the left scale, and estimated, counted and occupancy information derived from the calendar on the right scale. Occupancy counting was done in discrete time intervals, so it was expected that it won t follow the actual occupancy closely. Required and provided airflow volumes were calculated for each room based on the readings of the room s VAV controller using the following formulas: 3

Vneeded = Volumeflowcontrollersupexh/100 * VAV_Configured_setpoint_value; Vprovided = EXHcontrolsignal/100 * VAV_Nominal_flow Table 1 contains room-specific values used to calculate the needed and provided airflow into the rooms. Room number stored in DESIGO Table 1 Room-specific data for calculation of needed and provided airflow Name of the room in FH Diameter of the VAV (meters) Nominal flow (m3/h) Configured value for the setpoint (m3/h) E1.04 Seminar 1 0,2 1357 1200 E1.11 IT Lab 1 0,2 1357 600 E1.12 IT Lab 2 0,2 1357 600 E1.13 Office 0,2 1357 600 E1.14 Lecture room 1 0,3 3567 1200 E1.15 Lecture room 2 0,3 3567 1200 E1.22 Office 0,3 3567 1200 From these graphs several conclusions can be drawn. In general, the comfort in the room is considered optimal if CO2 concentration is kept under the set point most of the time. For two rooms (Room 11 Figure 2, Room 12 Figure 3) CO2 concentrations were above the set point almost for the whole duration of the experiment. For other rooms, set point value was satisfied, except for the period between 13:00 and 15:00 where the value peaked and then plateaued at around 1000 ppm for all the rooms except for room 112 (Figure 3), where it didn t exceed 900, but where it was also above the set point most of the time. On several graphs it looks like the local VAVs are being saturated (i.e. requesting locally defined maximal airflow), almost all the time, e.g. room 104. The actual data shows however that the reached value always falls short of configured maximums for VAVs. In case of Room 104, the configured maximum value is 1200m^3/h and the calculated value peaks at 600 m^3/h. In comparison to room 104, the room 111 shows quite the same amount of desired fresh air (needed airflow) - Figure 2. Despite the fact that an equal number of people is detected by the occupancy estimator the amount of fresh air remains the same. Apparently the controller limits the amount of fresh air taking also the energy consumption into consideration. The following effect of a rising CO2 concentration is hence clear. The actual value for CO2 goes beyond the CO2 set-point, however is accepted as such due to the constraints with regards to the energy consumption of the ventilation system fans. Room 112 see Figure 3 shows a similar behavior compared to rooms 104 and 111. However, the weights of the controller regarding the energy consumption were higher to see the effect of the energy efficient actuation (the needed airflow calculated by the controller is less than the one calculated for the rooms 104 and 111). Obviously the CO2 concentration is higher though, however accepted this way at the cost of lower energy consumption. There is also a mismatch between the calculated air flow and the actual one. The reason for that behavior could be the mismatch in the settings of the VAV (internal) controller and the model used to calculate the desired air flow of the model based controller. Room 114 shows an obvious behavior having only little need for fresh air as the estimation is calculating a count of 2 people see Figure 4. The controller is reacting to that accordingly, however, the process reaction does not happen instantaneously such that the results are visible straight away. As the test run was abandoned at around 4 pm the reaction to the actuation is not visible in these results. Room 115 shows equals behavior as room 114 see Figure 5. Figure 6 to Figure 8 show the cumulative needed, provided and needed/provided difference air flow respectively. Especially the graph showing the difference between required and provided is interesting as it shows how the difference gap develops over time. It is a good way to depict the overall fresh air needs for each room. 4

Figure 1 Airflow and CO2 concentration (Room 104) Figure 2 Airflow and CO2 concentration (Room 111) 5

Figure 3 Airflow and CO2 concentration (Room 112) Figure 4 Airflow and CO2 concentration (Room 114) 6

Figure 5 Airflow and CO2 concentration (Room 115) Figure 6 Cumulative needed airflow 7

Figure 7 Cumulative provided airflows Figure 8 Cumulative difference between needed and provided airflows 8

3 E+E Office Building In E+E building it was not possible to perform a test similar to the one in ENERGYbase building. Therefore only the data collection was performed and occupancy estimation was performed using the available data. 3.1 Heat Map Visualzations Figure 9 - Figure 14 represent the collected available dataset for room 8244 (one of the five rooms for which the monitoring data was collected). Data is represented in the form of an hourly heat map. Data is completely collected for the period of 2 months and 10 days between 1 st of February and 11 th of March. Collected datapoints include CO2 concentration, two temperature sensors for each room, provided airflow in cubic meters per hour, and calendar-based occupancy of each room. Estimated occupancy is then calculated using this data, and is represented here as well. It is clear from the graph that there is a strong correlation between airflow and estimated number of people, even in this coarse representation. Figure 9 CO2 concentration heat map for room 8233 9

Figure 10 Temperature heat map for room 8233 Figure 11 Temperature heat map for room 8233 10

Figure 12 Airflow heat map for room 8233 Figure 13 Estimated occupancy heat map for room 8233 11

3.2 Occupancy Estimates Figure 14 Calendar occupancy heat map for room 8233 Additionally, Figure 15 - Figure 19 are combined graphs of provided airflows and CO2 concentrations on the left scale, and calendar-based occupancy and estimated occupancy on the right scale. While the calendar-based occupancy time series is created from the room booking listing, it should not be considered a very precise measure of real occupancy. It is possible, and as can be seen from the graphs, quite usual, that people are present in the room even when there is no room booking in the system (Figure 16, around 9AM), or that number of people foreseen in the calendar differs significantly from the actual number of people (although we do not know the exact number of people, looking at Figure 15, the increased airflow, and CO2 trend it seems that the number of people present is significantly more than 1). The system is coping well with the load. The CO2 concentration is within the standard range, although the estimated occupancies are not exceeding 6 people, so it can be said that system was not exposed to high loads. 12

Figure 15 Combined plot for room 8229 Figure 16 Combined plot for room 8232 13

Figure 17 Combined plot for room 8233 Figure 18 Combined plot for room 8236 14

On Figure 19 it can be seen that, even though there is an announced occupancy, and an increase in CO2 level (between 8:00-13:00), the airflow remains almost zero. The actual airflow is increased early in the morning, and later in the evening and during the night. Figure 20 shows that this was typical for ventilation in this room, especially during February. CO2 concentration is, however, still inside the allowed range. This indicates some problem in the system configuration or in the monitoring system. Figure 19 Combined plot for room 8426 15

Figure 20 Airflow heat map for room 8426 showing strange behavior 4 Conclusion The upper graphs show good performance of the deployed model based controller for the EnergyBase building. Besides the possibility to actuate the VAV boxes according to the actual needs, which are apparently calculated upon the presence of people in the controlled rooms, there is also the option to take the energy efficiency into consideration. This is done by including weights into the control algorithms. Additional constraints in the control algorithms make sure that energy (electric) is not wasted. Naturally as the models used to run the controllers are fairly simplified, a tradeoff is made between control quality and computational power required to execute the algorithms. Due to technical restrictions no tests were performed for the E+E building. Nevertheless, a detailed energy analysis was performed to find the required correlations between the required volume flows and the people count. The upper figures show a good description of the correlations, pointing out the necessity to improve current situation with the coordinated, model based control of the VAV box configuration for the fresh air supply of the offices in the E+E building. 16