Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

Similar documents
Instruction manual AS 300 CG. Waste water filtration unit. Im Geer 20, D Isselburg. Descriptioin / Type-No.: AS 300 CG Typ 539

Series description Wilo-Drain STS 40

MS SE 30AH 500 Equipment options

Industrial flue gas probes. Instruction manual

Phoenix - Mixing System MIX08/20 Inline 20

AUTOMATIC AIR VALVES For potable water

Ion exchange Unit IXU 1/4 Series

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 01

KAWAMOTO SUBMERSIBLE PUMP 2 POLES / 50 Hz SIZE 32 ~ 50 MM.

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

CONTENTS Of the ROVELD P 315 B MANUAL 1. Introduction 2. Introduction for the welding process 3. Drawings and part lists of single machine parts of th

E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water.

booster EX2 / EX3 Operating Manual Extrusion Welder Weldy AG Galileo-Strasse 10 CH-6056 Kaegiswil / Switzerland TECHSPANGROUP

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

Nessie Pumps type PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100

4-Beam-Turbidity Meter ITM-4

Process Inline Filter, Change-Over

OffLine Filter OLF 5

Proweld Equipment Owner & Maintenance Manual FIELD 12 TRENCH (Widos 4900)

OPERATING MANUAL. Conveyor belts. CB-/B-Conveyor

Return Filters D 090 D 100. In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min e

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

Nessie Pumps type PAH 2/4/6.3, 10/ /32 and PAH 50/63/70/80

A c t i v a t e d C a r b o n F i l t e r Installation Operation Maintenance Manual

LUBRICATION PUMP Z2 CENTRAL LUBRICATION

HST -B Interlocking device (Translation of Original Manual)

Whitening Lamp. Instructions for use. flaesh.com

KRIWAN Wind Sensors. Operating Instructions Accessories and Application Information

Product information. UP-DO Pump Series Normal priming, centrifugal pumps with a double mechanical seal material: stainless steel 1.

Product Range Non-Metallic Pumps

PERISTALTIC PUMPS FOR USE IN THE FIELD

The Professional Choice LAC 200. Air oil cooler SIZE MATTERS! OLAER LAC 200 The largest standard air oil cooler in the class

Operate Manual. DA-1600i Stud Welding Machine. DA-2000i Stud Welding Machine. DA-2500i Stud Welding Machine

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

HÜLLER-HILLE NBH 170-4

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. One-line aggregate GEI-B. Use:

User Guide Water-Filter-System for Treatment of Heating-System Make-Up Water

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

D 090 D 100 In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min

Pipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01)

SHREE DUJA SPRAY EQUIPMENTS

CLEAN SOLUTIONS Wastewater disposal and fresh water supply from coaches

Starch separator. Chapter contents. Starch separator for ground installation. Starch separator for freestanding. Informations.

HD 152 HD 172 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to 190 l/min

AirBench EX Operation and Maintenance

Operating pressure Atmospheric pressure 1.96 MPa (See note 2.) 981 kpa (See note 2.) General applications for purified water and wastewater

Instruction manual of Fluidized Bed Reactor FBR diameter 250 mm and larger

Modulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING.

DURMAT PTA Welding Equipment: PTA Power Sources PTA Manual Torches, Robot Torches, Special Torches PTA Accessories

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.

Series Sump and Sewage Systems

Instruction Manual C20

Water Softener softliq:mc. Intended use. Function. Design

Largo & Allegro. Air Compressors. Largo & Allegro

E 444 E 454 E 464 E 644 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 680 l/min / gpm

Translation of the original instructions. Type: PR 8-20

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

MODEL INSTALLATION INSTRUCTIONS

Gelovit 200 en English

USER S MANUAL release 1.0

N-pump, Standard Motor

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

Dirty paper take up and filter cake stripper for separation of paper and waste are optional.

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

Packaging Handbook for Suppliers. Guidelines for Packaging of Outsourced Items

WEBAC 240. Technical Information. Range of application WEBAC 240. Examples

Pre-installation Manual. Plate Processor 68/85 Thermal

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

Operating and Maintenance Manual. for. HADEF locking device for monorail trolleys

GRUNDFOS UNILIFT CC. Multi-purpose submersible drainage pumps

Close Coupled Sump Pumps Type ETLB

MODEL ZL INSTALLATION INSTRUCTIONS

PRODUCT DATA kg / 2600 kg

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF

360 Quality Code. Recommendations for Container Pre-Trip Inspections February 2015

Sealing and blister punching machines

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

geba fire damper WFK according to EN 15650

WEGO3 Cooling and filter system

SO2 measurement on flue gas desulfurization systems. Instruction manual

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

VSM/55600/N2, Hollow piston rod cylinder Magnetic piston, double acting

Heated FID OVF Portable THC/TVOC Analyzer

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

Georg Fischer Waga N.V. The reliable wide range fitting for large pipe diameters DN450 - DN600 MULTI/JOINT XL

Installation Plan. Washer-extractor PW 6088 EL LP. en - AU M.-Nr

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

Flygt 3171, 50Hz. Technical Specification

Transcription:

Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type-No.: Type 523

Table of contents on Page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use 4 2.2 Operation 4 3 Transport 5 31. Delivery 5 3.2 Transport 5 3.3 Storage 5 4 Scope of delivery 6 5 Technical description 6 5.1 Unit description 6 5.2 Effectiveness of waste water filtration 7 6 Technical data 8 6.1 Connections, Measurement, Weights 8 6.2 Waste water pump 8 6.3 Filter system 8 7 Initial operation 9 7.1 Initial operation with waste water hose and proximity switch 10 8 Maintenance and care 12 8.1 Daily maintenance 12 8.2 Filter change 12 9 Circuit diagram 14 10 Declaration of conformity 15 Seite 2

Thank you for selecting a deconta product! 1 Introduction With this device you obtain a practical solution with simple operation, which was completed in a compact and functional way. The deconta products guarantee: Stability, durability and serviceability on site Technology with a difference Appealing design The copy right of this guide book remains the property of deconta. This guide book is destined for the field service and survey personnel. It contains instructions and drafts of technical nature which may not be used completely or in extracts for the purpose of competition and may not be distributed among others. For more information please visit our website www.deconta.com Seite 3

2 Basic safety advice The handling of the appliance technology is only allowed for instructed staff. The exact knowledge of the guide book is an important condition for your staff before handling the machine 2.1 Intended use deconta has to engage you as the user to follow the guide book and to employ this engineered technology only in accordance with the regulations and not in a inappropriate way! In the event of non-observance, deconta assumes no liability. 2.2 Operation To ensure safety during operation, the following must be observed: Do not use in hazardous areas. Necessary repairs, maintenance and cleaning, in particular in the field of electrical equipment is to be realized by qualified staff Keep Safety and protective equipment in perfect function. Attached safety instructions are to be kept in a readable state and are to be followed. To ensure safety, changes to the unit are prohibited. ATTENTION! The Waste water filtration unit is not suitable for the use in condensed, corrosive, flammable and explosive compartment air. The ambient and medium temperature must be between +5 and +50 C. Protect against moisture! Seite 4

3.1 Delivery 3 Transport If no other agreements have been made, the unit is packed safely and will be delivere d ex work. Transport damages have to be documented immediately upon delivery by the carrier or another supplier. Please note the possible damages additionally on the way bill. The Transport is to be proceeded with care to avoid damages by improper handling or carelessness. 3.2 Transport It is important to avoid exposure to violent shocks, otherwise the function and safety of the unit cannot be guaranteed. In winter and at risk of frost, the whole unit (waste water pump and filter housing) needs to be emptied before transport. 3.3 Storage In order to avoid damages, the installation has to be kept in a dry area with no access for unauthorized persons. Because of risk of frost in winter you have to observe following: Empty out water pipes and filter housing Empty out water pump through discharging screw Place the waste water filtration plant in a place protected against frost. Ventilation connection Drain screw Seite 5

4 Scope of delivery If no other agreements have been made, the scope of delivery of the waste water filtration unit contains the: Waste water filtration unit 2x Geka-coupling leak proof 2x Hose clamp Filter head wrench Guide book 5 Technical description 5.1 Unit description The waste water contaminated with asbestos fibres is cleaned via a 3 stages filtering unit composed of a rinsing filter 220, fine filter 50 (disposable filter) and fine filter 1 (disposable filter). The state of the filter is controlled by a manometer. The entire unit is located in a powder-coated steel iron housing with standard Gekaconnections. Seite 6

5.2 Effectiveness of waste water filtration unit Test: Filter separation wound candle 1 Micrometer Diameter in Micrometer 100 90 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 80 70 60 50 40 30 20 Measuring point Diameter % Effectiveness 1 0,77 84,3 2 0,97 90,4 3 1,22 93,5 4 1,54 95,0 5 1,93 96,2 6 2,44 97,4 7 3,07 98,5 8 3,87 99,7 9 4,87 99,8 10 6,14 100,0 11 7,74 100,0 12 9,75 100,0 13 12,28 100,0 14 15,47 100,0 15 19,49 100,0 16 24,56 100,0 17 30,94 100,0 10 0 30,9 24,6 19,5 15,5 12,3 9,75 7,74 6,14 4,87 3,87 3,07 2,44 1,93 1,54 1,22 0,97 0,77 Seite 7

6.1 Connections, Measurements, Weights 6 Technische Daten Power connection: Personal security: Hose connection: Dimensions (L x W x H): Weight: 230V 50Hz FI-Schalter 30mA System Geka 800 x 550 x 980 mm ca.43 kg 6.2 Waste water pump Self-priming and safe to run dry Voltage: 230V, 50Hz Capacity: 0,45 kw Flow capacity max.: 30 l/min max. medium temperature: 90 C Fuse type: IP44 6.3 Filter system 4- stage filtering unit Bag filter: 220 µ (reusable) Pre filter: 10" 220 (disposable) Fine filter: 20" 50 (disposable) Fine filter: 20" 1 (disposable) max. medium temperature: 50 C at 4bar Technical changes reserved Seite 8

7 Initial operation Before the initial operation of the sewage pump or after a long standstill you have to control if you can turn the spindle by hand. For this purpose, insert a screw driver in the slot in the shaft end of the fan side and move the shaft. If the pump is new, you will have a strong turning resistance in the running wheel, but it will relieve after some time. Fill waste water pump fully through vent connection Tighten the cap nut of the filter housing by hand Connection IN Connection OUT Coarse pre filter Cap nut Connect waste water hose with proximity switch at IN of the coarse pre filter and then connect to place of use (only use spiral hose) Connect OUT with gully Establish power supply 230V, 50Hz (Schuko plug) Seite 9

Selector switch Switch on unit (Position MAN at selector switch) and check, if filter housings are filling with water 7.1 Initial operation with waste water hose with proximity switch As an option, a waste water hose with proximity switch for electrical and automatic On/Off switch function is available. Before the initial operation of the sewage pump or after a long standstill you have to control if you can turn the spindle by hand. For this purpose, insert a screw driver in the slot in the shaft end of the fan side and move the shaft. If the pump is new, you will have a strong turning resistance in the running wheel, but it will relieve after some time. Fill waste water pump fully through vent connection Tighten the cap nut of the filter housing by hand Seite 10

Connection IN Connection OUT Coarse pre filter Cap nut Connect waste water hose with proximity switch at IN of the coarse pre filter and then connect to place of use (only use spiral hose) Establish power supply for proximity switch Connect OUT with gully Establish power supply 230V, 50Hz (Schuko plug) Selector switch Power supply Proximity switch Switch on unit (Position AUTO at selector switch) The proximity switch at the waste water hose recognizes, if there is water in the hose and switches the Waste water unit automatically on or off. The sensitivity of the proximity switch may be readjusted with help of the screw driver, added to the delivery. Seite 11

8.1 Daily maintenance Check hoses for free flow Visual check of 220µ-Pre filter for dirt Control of fine filter via manometer 8 Wartung und Pflege 8.2 Filter change The Bag filter inserted in the coarse pre filter may be removed, cleaned and reused. The Manometer controls the fine filter. We recommend a filter change at approx. 3bar. Cap nut Fine filter 5µ Fine filter 1µ Coarse pre filter with bag filter 220µ Manometer Pre filter 220µ Filter head wrench Attention: Filter change only if the device is switched off Demount dirty filters only in wet shape to avoid contamination Use only allowed filters Do not use damaged filter candles Seite 12

Filter change: Loosen cap nut with help of filter head wrench Remove filter and dispose off Insert new filter candles Pay attention to correct fit and cleanliness of the seal ring Tighten cap nut by hand The suction hoses, pumps, filter housings and filter are contaminated after the first use. Repairs and maintenance have to be executed under the observance of all relevant safety measures. All the filters mentioned have to be disposed according to the legal terms. Seite 13

9 Circuit diagram Seite 14

10 Declaration of conformity deconta GmbH Im Geer 20 D-46419 Isselburg EU-Declaration of conformity Produkt: Waste water filtration unit Type: 523 The design of the unit corresponds to the following regulations: EU- Machine directive 2006/42/EG EU- Low voltage directive 2006/95/EG Applied harmonised standards: EN 292, EN 60335-1 Applied national standards: DIN VDE 0701, DIN VDE 0702 W.Weßling Isselburg, 29.05.2013 Seite 15