Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type-No.: Type 523
Table of contents on Page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use 4 2.2 Operation 4 3 Transport 5 31. Delivery 5 3.2 Transport 5 3.3 Storage 5 4 Scope of delivery 6 5 Technical description 6 5.1 Unit description 6 5.2 Effectiveness of waste water filtration 7 6 Technical data 8 6.1 Connections, Measurement, Weights 8 6.2 Waste water pump 8 6.3 Filter system 8 7 Initial operation 9 7.1 Initial operation with waste water hose and proximity switch 10 8 Maintenance and care 12 8.1 Daily maintenance 12 8.2 Filter change 12 9 Circuit diagram 14 10 Declaration of conformity 15 Seite 2
Thank you for selecting a deconta product! 1 Introduction With this device you obtain a practical solution with simple operation, which was completed in a compact and functional way. The deconta products guarantee: Stability, durability and serviceability on site Technology with a difference Appealing design The copy right of this guide book remains the property of deconta. This guide book is destined for the field service and survey personnel. It contains instructions and drafts of technical nature which may not be used completely or in extracts for the purpose of competition and may not be distributed among others. For more information please visit our website www.deconta.com Seite 3
2 Basic safety advice The handling of the appliance technology is only allowed for instructed staff. The exact knowledge of the guide book is an important condition for your staff before handling the machine 2.1 Intended use deconta has to engage you as the user to follow the guide book and to employ this engineered technology only in accordance with the regulations and not in a inappropriate way! In the event of non-observance, deconta assumes no liability. 2.2 Operation To ensure safety during operation, the following must be observed: Do not use in hazardous areas. Necessary repairs, maintenance and cleaning, in particular in the field of electrical equipment is to be realized by qualified staff Keep Safety and protective equipment in perfect function. Attached safety instructions are to be kept in a readable state and are to be followed. To ensure safety, changes to the unit are prohibited. ATTENTION! The Waste water filtration unit is not suitable for the use in condensed, corrosive, flammable and explosive compartment air. The ambient and medium temperature must be between +5 and +50 C. Protect against moisture! Seite 4
3.1 Delivery 3 Transport If no other agreements have been made, the unit is packed safely and will be delivere d ex work. Transport damages have to be documented immediately upon delivery by the carrier or another supplier. Please note the possible damages additionally on the way bill. The Transport is to be proceeded with care to avoid damages by improper handling or carelessness. 3.2 Transport It is important to avoid exposure to violent shocks, otherwise the function and safety of the unit cannot be guaranteed. In winter and at risk of frost, the whole unit (waste water pump and filter housing) needs to be emptied before transport. 3.3 Storage In order to avoid damages, the installation has to be kept in a dry area with no access for unauthorized persons. Because of risk of frost in winter you have to observe following: Empty out water pipes and filter housing Empty out water pump through discharging screw Place the waste water filtration plant in a place protected against frost. Ventilation connection Drain screw Seite 5
4 Scope of delivery If no other agreements have been made, the scope of delivery of the waste water filtration unit contains the: Waste water filtration unit 2x Geka-coupling leak proof 2x Hose clamp Filter head wrench Guide book 5 Technical description 5.1 Unit description The waste water contaminated with asbestos fibres is cleaned via a 3 stages filtering unit composed of a rinsing filter 220, fine filter 50 (disposable filter) and fine filter 1 (disposable filter). The state of the filter is controlled by a manometer. The entire unit is located in a powder-coated steel iron housing with standard Gekaconnections. Seite 6
5.2 Effectiveness of waste water filtration unit Test: Filter separation wound candle 1 Micrometer Diameter in Micrometer 100 90 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 80 70 60 50 40 30 20 Measuring point Diameter % Effectiveness 1 0,77 84,3 2 0,97 90,4 3 1,22 93,5 4 1,54 95,0 5 1,93 96,2 6 2,44 97,4 7 3,07 98,5 8 3,87 99,7 9 4,87 99,8 10 6,14 100,0 11 7,74 100,0 12 9,75 100,0 13 12,28 100,0 14 15,47 100,0 15 19,49 100,0 16 24,56 100,0 17 30,94 100,0 10 0 30,9 24,6 19,5 15,5 12,3 9,75 7,74 6,14 4,87 3,87 3,07 2,44 1,93 1,54 1,22 0,97 0,77 Seite 7
6.1 Connections, Measurements, Weights 6 Technische Daten Power connection: Personal security: Hose connection: Dimensions (L x W x H): Weight: 230V 50Hz FI-Schalter 30mA System Geka 800 x 550 x 980 mm ca.43 kg 6.2 Waste water pump Self-priming and safe to run dry Voltage: 230V, 50Hz Capacity: 0,45 kw Flow capacity max.: 30 l/min max. medium temperature: 90 C Fuse type: IP44 6.3 Filter system 4- stage filtering unit Bag filter: 220 µ (reusable) Pre filter: 10" 220 (disposable) Fine filter: 20" 50 (disposable) Fine filter: 20" 1 (disposable) max. medium temperature: 50 C at 4bar Technical changes reserved Seite 8
7 Initial operation Before the initial operation of the sewage pump or after a long standstill you have to control if you can turn the spindle by hand. For this purpose, insert a screw driver in the slot in the shaft end of the fan side and move the shaft. If the pump is new, you will have a strong turning resistance in the running wheel, but it will relieve after some time. Fill waste water pump fully through vent connection Tighten the cap nut of the filter housing by hand Connection IN Connection OUT Coarse pre filter Cap nut Connect waste water hose with proximity switch at IN of the coarse pre filter and then connect to place of use (only use spiral hose) Connect OUT with gully Establish power supply 230V, 50Hz (Schuko plug) Seite 9
Selector switch Switch on unit (Position MAN at selector switch) and check, if filter housings are filling with water 7.1 Initial operation with waste water hose with proximity switch As an option, a waste water hose with proximity switch for electrical and automatic On/Off switch function is available. Before the initial operation of the sewage pump or after a long standstill you have to control if you can turn the spindle by hand. For this purpose, insert a screw driver in the slot in the shaft end of the fan side and move the shaft. If the pump is new, you will have a strong turning resistance in the running wheel, but it will relieve after some time. Fill waste water pump fully through vent connection Tighten the cap nut of the filter housing by hand Seite 10
Connection IN Connection OUT Coarse pre filter Cap nut Connect waste water hose with proximity switch at IN of the coarse pre filter and then connect to place of use (only use spiral hose) Establish power supply for proximity switch Connect OUT with gully Establish power supply 230V, 50Hz (Schuko plug) Selector switch Power supply Proximity switch Switch on unit (Position AUTO at selector switch) The proximity switch at the waste water hose recognizes, if there is water in the hose and switches the Waste water unit automatically on or off. The sensitivity of the proximity switch may be readjusted with help of the screw driver, added to the delivery. Seite 11
8.1 Daily maintenance Check hoses for free flow Visual check of 220µ-Pre filter for dirt Control of fine filter via manometer 8 Wartung und Pflege 8.2 Filter change The Bag filter inserted in the coarse pre filter may be removed, cleaned and reused. The Manometer controls the fine filter. We recommend a filter change at approx. 3bar. Cap nut Fine filter 5µ Fine filter 1µ Coarse pre filter with bag filter 220µ Manometer Pre filter 220µ Filter head wrench Attention: Filter change only if the device is switched off Demount dirty filters only in wet shape to avoid contamination Use only allowed filters Do not use damaged filter candles Seite 12
Filter change: Loosen cap nut with help of filter head wrench Remove filter and dispose off Insert new filter candles Pay attention to correct fit and cleanliness of the seal ring Tighten cap nut by hand The suction hoses, pumps, filter housings and filter are contaminated after the first use. Repairs and maintenance have to be executed under the observance of all relevant safety measures. All the filters mentioned have to be disposed according to the legal terms. Seite 13
9 Circuit diagram Seite 14
10 Declaration of conformity deconta GmbH Im Geer 20 D-46419 Isselburg EU-Declaration of conformity Produkt: Waste water filtration unit Type: 523 The design of the unit corresponds to the following regulations: EU- Machine directive 2006/42/EG EU- Low voltage directive 2006/95/EG Applied harmonised standards: EN 292, EN 60335-1 Applied national standards: DIN VDE 0701, DIN VDE 0702 W.Weßling Isselburg, 29.05.2013 Seite 15