Optimization of COD and Colour Removal From Landfill Leachate by Electro-Fenton Method

Similar documents
Treatment of Palm Oil Mill Effluent by Electrocoagulation with Aluminium Electrodes

REDUCTION OF COD IN WASTEWATER FROM A TEXTILE INDUSTRY BY ELECTRO-FENTON PROCESS

RecShow '08. Middle East Recycling, Waste & Environmental Management Exhibition & Congress. Kempinski Hotel, Dead Sea - Jordan February 2008

HKICEAS-671 Optimization of Reactive Dyes Degradation by Fenton oxidation Using Response Surface Method

A Research on treatability of leather industry wastewater by using electro-fenton process

Application of a hybrid Electrocoagulation-Fenton process in yarn dye wastewater: Kinetic study

Using an anodic Fenton process for degradation of nitrobenzene in waste water

DECOLOURISATION OF REACTIVE BLUE 28 FROM DYE WASTE WATER BY PHOTO FENTON PROCESS AND SONO FENTON PROCESSES

Fenton Oxidation Process Control Using Oxidation-reduction Potential Measurement for Pigment Wastewater Treatment

Removal of Water Turbidity by the Electrocoagulation Method

Investigation of Color Removal of Sunflower Oil Industrial Wastewater with Fenton Process

Electrochemical Degradation of Acridine Orange Dye at Ru-Doped Platinum Anode in Aqueous Solution

COMPARISON OF FE AND AL ELECTRODES IN THE TREATMENT OF BLUE CA DYE EFFLUENT USING ELECTRO COAGULATION PROCESS.

Distillery Wastewater Decontamination by the Fenton Advanced Oxidation Method

Removal of COD and Colour from Sanitary Landfill Leachate by using Coagulation Fenton s Process

Advanced Treatment of Pistachio Processing Industry Wastewater by Fenton Process

The Performance of Electro-Fenton Oxidation in the Removal of Pesticides from Wastewater Using Stainless Steel Electrodes

INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES Volume 6, No 6, Copyright by the authors - Licensee IPA- Under Creative Commons license 3.

Study on the Treatment of Effluents from Paint Industry by Modified Electro-Fenton Process

Removal of Malachite Green Dye from aqueous solution by Fenton Oxidation

Composting Plant Leachate Treatment by Coagulation-Flocculation Process

Available online at Scholars Research Library. Archives of Applied Science Research, 2011, 3 (2):

SUBSEQUENT FENTON PROCESS AND NEUTRALIZATION FOR WASTEWATER TREATMENT OF TEXTILE HOME INDUSTRY

Electrocoagulation of Drinking Water in Continuous Flow Mode for Fluoride Removal

International Journal of Innovative Research in Science, Engineering and Technology. (An ISO 3297: 2007 Certified Organization)

Treatment of Municipal Landfill Leachate by Oxidants

Advances in Environmental Biology

Azmi Aris, Ooi Boon Siew, Kon Suh Kee, Zaini Ujang

OPTIMAL CHEMICAL DOSING RATES FOR HEAVEY METALS REMOVAL FROM LEATHER WASTE WATER EFFLUENT

Landfill Leachate Treatment Using Hybrid Up-Flow Anaerobic Sludge Blanket (HUASB) Reactor

DECOLORIZATION OF LANDFILL LEACHATE USING ELECTROCHEMICAL TECHNIQUE

Complete oxidation of organic substances in wastewater using an Advanced Oxidation Process with synthetic diamond electrodes

Treatability studies on bleach effluent of pulp and paper industry by ultraviolet/hydrogen peroxide process with titanium dioxide as catalyst

Treatment of non-biodegradable wastewater by electro-fenton method

Color and COD removal from waste water containing acrylic water base color using Fenton's oxidation process

Assessment of Electrocoagulation for Groundwater Purification

Characterization of Ammonia Removal from Municipal Wastewater Using Microwave Energy: Batch Experiment

Iraqi Journal of Chemical and Petroleum Engineering Vol.9 No.3 (December 2007) ISSN:

Aerobic Sludge Digestion in the Presence of Chemical Oxidizing Agents Part II. Fenton's Reagent

Fenton's catalytic oxidation process to treat landfill leachate

Treatment of landfill leachate from Fez city (Morocco) using Fenton and photo-fenton processes

TREATMENT OF TEXTILE EFFLUENT USING PHOTO-FENTON PROCESS IN PRESENCE OF BANANA PEEL AS AN ADSORBENT

Journal of Engineering Science and Technology Review 9 (1) (2016) Research Article

Electrocoagulation. Achieving clean, clear, treated and reusable water: The process, technology and benefits. CALL US (631)

Process water treatment by oxidative and electrolytic

Suspended Solids Sedimentation of River Water Influenced by Electrocoagulation

OXIDATIVE TREATMENT BY HYDROGEN PEROXIDE FOR THE REMOVAL OF COD AND SULPHIDE FROM TANNERY LIMING WASTEWATER

Oxidation of Pre-Coagulated Semi Aerobic Leachate

Original Research The Modified Fenton Process for Decolorization of Dye Wastewater. K. Barbusiński*

Treatment of Compost Leachate by Sequential Coagulation and Photo Fenton Process

International Journal of Advance Engineering and Research Development TREATMENT OF SUGAR INDUSTRY WASTE WATER BY ELECTROCOAGULATION (EC) TECHNIQUE.

Influence of operating parameters on ammonia nitrogen removal from micro-polluted water by electro-coagulation-flotation with aluminum electrodes

Vitor J. P. Vilar Principal Researcher Associate Laboratory LSRE/LCM Faculty of Engineering University of Porto

Pelagia Research Library

Short-term and long-term studies of the co-treatment of landfill leachate and municipal wastewater

Experimental Design for the Elimination of Fluoride from Pretreated Photovoltaic Wastewater by Electrocoagulation

ELECTROCOAGULATION OF PALM OIL MILL EFFLUENT USING ALUMINIUM ELECTRODES

Electrochemical Treatment Of Rice Grain Based Distillery Effluent Using Iron Electrode

Removal of Dye from Textile Wastewater by Electrolytic Treatment

Decolorization of Textile Wastewater by Electrochemical Process in the Presence of Hydrogen peroxide and Poly Aluminum Chloride

TREATMENT OF TEXTILE EFFLUENT USING HETEROGENEOUS FENTON AND MICROFILTRATION

Treatment of Dye Intermediate Waste-Water by Fenton and Electro-Fenton Treatments

LANDFILL LEACHATE TREATMENT USING FENTON PROCESS: COD LOADING vs TREATMENT EFFICIENCY

Analytical & Bioanalytical Electrochemistry

International Journal of Science, Environment and Technology, Vol. 4, No 5, 2015,

Electrocoagulation Of Distillery Spentwash For Complete Organic Reduction

Study the Efficiency of Various Metal Powder Composition Electrodes Based on Landfill Leachate Treatment

APPLICATION OF IRON NANOPARTICLES FOR INDUSTRIAL WASTEWATER TREATMENT. Martina SUKOPOVÁ*, Jana MATYSÍKOVÁ*, Ondřej ŠKORVAN*, **, Marek HOLBA*,***

Landfill Leachate Treatment Using PAC Supplemented SBR Technique-Influence of Input Air

Chapter - 6 Treatment for Recycling of Segregated Wastewater Generated from Dyes, Dye Intermediates and Textile Dyeing and Printing Industries of

Chemical Precipitation and Ballasted Flocculation

Water Purification by Electrocoagulation

ENVIRONMENTAL ENGINEERING LECTURE 3: WATER TREATMENT MISS NOR AIDA YUSOFF

EXPERIMENTAL EVALUATION OF PHYSICAL CHEMICAL TREATMENT OPTIONS FOR DENIM PROCESSING WASTEWATER

EFFECT OF FERROUS SULPHATE ON THE SIMULTANEOUS ORGANIC MATTER AND NUTRIENT REMOVAL PERFORMANCE OF SEQUENCING BATCH REACTOR

Using Microwave Energy for the Removal of Ammonia From Municipal Wastewater: Continuous Flow Lab-Scale System

Tehran, Iran. Bandar Abbas, Iran. Tehran, Iran. Tehran, Iran.

Removal of Heavy Metal from Landfill Leachate Using Vertical Flow Construction Wetland

Removal of Organic Pollutants from Reverse Osmosis Concentrate by Electro-Fenton Process

Photo-Oxidation Process Application for Removal of Color from Textile Industry Effluent

Cuvette Test LCK 555 BOD 5 /BOD [n]

Electrochemical Treatment of Oily wastewaters (shipyards) for removal of organics and water Reclamation

Electro-Pure Technology. Advanced Water Treatment Technology. Ability to treat a wide range of contaminants simultaneously

DECOMPOSITION OF NON-IONIC SURFACTANT SYMPERONIC NP10 BY THE FENTON PROCESS IN THE PRESENCE OF IRON-OXIDE NANOPARTICLES

[Multani, 3(2): February, 2014] ISSN: Impact Factor: 1.852

Textile wastewater treatment: colour and COD removal of reactive black- 5 by ozonation

Domestic Wastewater Treatment by Electrocoagulation Using Copper and Aluminum Electrodes

Study of Electrochemical Degradation of Bromophenol Blue at Boron-doped Diamond Electrode by Using Factorial Design Analysis

Evaluation of Electrocoagulation and Fenton's reagent for Arsenic removal from drinking water

Decolorization of the dye reactive black 5 using Fenton oxidation

Combined Adsorption and Biological Treatment for Landfill Leachate Management

Characterization and Design of Sewage Treatment Plant in Bidar City

REMOVAL OF 254 NANOMETER IRRADIATION QUELLING POLLUTATNS FROM PRETREATED LANDFILL LECHATES BY FENTON PROCESS AS A POST-TREATMENT SYSTEM

Study On Treatment Of Municipal Solid Waste Landfill Leachate By Fenton Process

Photolysis, Sonolysis and Ozonolysis for Degradation of 2,4-dichlorophenoxyacetic acid (2,4-D)

Cuvette Test LCK 555 BOD 5 /BOD [n]

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Disposal of Sludge with Solid Wastes in Aerobic and Anaerobic Landfill Areas

On-Site Sodium Hypochlorite Generation Equipment

Reduction of Biochemical Oxygen Demand and Chemical Oxygen Demand of Metalworking Fluid Wastewater by Electrochemical Oxidation

Transcription:

Australian Journal of Basic and Applied Sciences, 7(8): 263-268, 2013 ISSN 1991-8178 Optimization of COD and Colour Removal From Landfill Leachate by Electro-Fenton Method 1 Zawawi Daud, 1 Nur Fatihah Muhamad Hanafi, 2 Halizah Awang 1 Faculty of Civil and Environmental Engineering 2 Faculty of Technical and Vocational Education Universiti Tun Hussein Onn Malaysia, 86400 Batu Pahat, Johor, MALAYSIA Abstract: The contamination of untreated leachate effluent is a potential source to effect of soil, surface and groundwater.in this study, the treatment of landfill leachate by electro-fenton (EF) method was studied. The objectives of the study are to determine the optimum current density, the optimum treatment time, the optimum ph, the optimum hydrogen peroxide (H 2 O 2 ) dosage and the optimum ferrous sulphate heptahydrate (FeSO 4 7H 2 O) dosage of landfill leachate samples using aluminium electrode. From the results, it is verified that electro-fenton method (EF) can used efficiently to degrade leachate organics. The best removal efficiencies were obtained when current density value is 200 A/m 2, treatment time is 25 min and ph value is 4. The optimum dose of hydrogen peroxide (H 2 O 2 ) is 800 mg/l which was obtained 78% and 96% of COD and colour removal efficiency respectively. The optimum ferrous ion (Fe 2+ ) is 1000 mg/l which was obtained 75% and 94% of COD and colour removal efficiency respectively. Key words: landfill leachate, electro-fenton, COD, colour, aluminium electrodes INTRODUCTION Recently, the industrial and commercial growth in many countries has been affected in the increases of both municipal and industrial solid waste generations. Percentage composition of solid waste is different between areas because it is influenced by several factors such as location, community attitudes, frequency of collection, legal systems, population characteristics, socio-economic and lifestyle. Up to 95% of solid waste generated worldwide is currently disposed in landfill (Bohdziewicz and Kwarciak, 2008). Leachate is a high strength wastewater which has been recognized as one of the most concerned pollution sources. Landfill leachate is the hazardous and heavily polluted wastewater, formed as a result of percolation of rainwater and moisture through solid waste in the landfill site (Bohdziewicz and Kwarciak, 2008; Amuda, 2006). Landfill leachate contain high load of organic matter, high content ammonia nitrogen, heavy metals, inorganic salts and chlorinated organic. The composition of leachate depends on age of landfill, hydrogeology of the site, quality and quantity of solid waste, site climate, season, biological and chemical processes occurring in the landfill and the amount of precipitation and percolation of rainwater, landfill morpology, waste depth, landfill condition and operation of facilities (Li et al., 2010). Lately, advanced oxidation processes (AOPs) have been studies because of their ability to generate radical intermediate compounds. The radical intermediate compounds contain highly oxidative species which are capability to oxidize toxic pollutants into harmless species. Technologies of oxidation processes such as Fenton oxidation, photo-oxidation and electro-oxidation are recurrently applied to increase efficiency of electro-chemical methods in order for degradation and decolourization of wastewater. Today, there has been an increases focus on the use of electro-chemical methods which can produce OH as the main oxidizing agent ( Brillas et al., 2000; Kraft et al., 2003; Mohajeri et al., 2010). One of the promising of ability to degrade pollutants effectively is electro-fenton (EF). Electro-fenton (EF) method has been applied with combination of fenton oxidation and electrochemical are carried out together and each of them is a powerful treatment method (Atmaca, 2009; Brillas and Casado, 2002; Mohajeri et al., 2010). This process is use of electrically assisted Fenton reaction will produce more OH radicals and the oxidation of the organics to CO 2 can be enhanced in the same period (Mohajeri et al., 2010; Liu et al., 2007). Normally, there are two different electro-fenton (EF) applications. In the first one the Fenton s reagents (Fe (II) and H 2 O 2 ) are added to the reactor from outside and inert electrodes having high catalytic activity are used as anode material. In the second one, H 2 O 2 is added from outside and Fe (II) is provided from sacrificial cast iron anodes. In the electro- Fenton process, hydrogen peroxide (H 2 O 2 ) is produced in the required amount from the electrochemical reduction of oxygen. Hydroxyl free radical is generated by interaction of H 2 O 2 with ferrous salts namely the Fenton reagent. The objective of this study was to examine the efficiency of electro-fenton process for removal of COD and colour from landfill leachate. The experiments involved with the determination of current density, treatment time, ph, dose of hydrogen peroxide (H 2 O 2 ) and ferrous sulphate heptahydrate (FeSO 4 7H 2 O) on identification Corresponding Author: Zawawi Daud, Faculty of Civil and Environmental Engineering E-mail: zawawi@uthm.edu.my 263

of the optimum experimental conditions for the efficient application of these processes. In this study, the used of aluminium plate as electrodes. MATERIALS AND METHODS Preparation of Sample: The study was conducted on leachate samples from Simpang Renggam municipal landfill site in Johor. This site located at latitude 1 0 53 41.64 North and longitude 103 0 22 34.68 East in Kluang district, Johor State, Malaysia. Sample has been taken and stored according to the Standard Methods for the Examination of Water and Wastewater (APHA, AWWA, WEF, 2005). Leachate samples were taken from landfill site by using a submersible pump is submerged at a depth 1500 mm from the surface leachate site. Landfill leachate samples are collected and stored in bottles and kept in a room at 4 C prior to use to avoid degradation or changes to its characteristics. The initial characteristics of COD and colour for landfill leachate samples were determined. Table 1 were shown the initial characteristics of the raw landfill leachate. Table 1: Characteristics of landfill leachate collected from Simpang Renggam Municipal Landfill Site Parameter Initial Characteristics Chemical Oxygen Demand (COD) 13166-13500 Suspended Solids (SS) 270-1200 Ammonia Nitrogen (NH 3-N) 755-2670 Colour 2393-12400 ph 8.31-8.47 *All units are in mg/l except for ph and Pt.Co for colour Experiment Set Up: The electro-fenton experiments were using 1000 ml beakers as reactors with the diameter of 11 cm by vertically positioned Al-Al electrode spaced by 5 cm which carried out on laboratory scale. The electrodes dimension of each electrode was 200 mm 50 mm 1 mm made of aluminium are connected to a digital direct current (DC) power supply (MPS 3030DD Model) in bipolar (Al-Al) electrode modes. A direct current (DC) power supply was used to provide the desired current. Initial leachate ph was adjusted to the desired values with concentrated sulphuric acid or sodium hydroxide before adding Fenton reagents. The anodes and cathodes are connected to the positive and negative outlets of a DC power supply. The total effective working areas are 0.010 m 2 when immersed 10 cm into the leachate sample. In each run, a pre-decided amount of ferrous sulphate heptahydrate (FeSO 4 7H 2 O) and hydrogen peroxide (H 2 O 2 ) were added into leachate samples to activate electro-fenton reactions before the electrical current was turned on. The leachate was stirred thoroughly with a magnetic stirrer. At an appropriate time intervals, DC power supply was turned off and the reactions was terminated. At the end of each run, the sample were allowed to stand 30 minutes settling time and the supernatant was then taken for water quality measurements. COD was measured using a DR5000 spectrophotometer (HACH spectrophotometer) and colour was measured using same spectrophotometer at 465nm wavelength. Apparatus: Reactor (glass tank): One liter glass beaker is used as the reactor tank in the experimental studies. Electrodes: Aluminum electrodes are used in the electrocoagulation process as plates for the anodes and cathodes with the dimension of 200 mm high 50 mm wide 1 mm thick. ph: HACH Sension3 ph meter is used to determine the ph of the POME samples. To obtain the optimum ph value, the ph of landfill leachate samples was adjusted by adding sodium hydroxide (NaOH) or sulphuric acid (H 2 SO 4 ). Chemical Oxygen Demand and Colour Analyses: COD and colour analyses are performed in accordance to the standard methods described in (APHA, AWWA, WEF, 2005) with the use of DR 5000 spectrophotometer. 264

RESULTS AND DISCUSSION Optimum Current Density: Figure 1 was shown the optimum current density on the removal efficiency of COD and colour for Al-Al. In this study, the optimum current density is 200 A/m 2 which was obtained 74% and 96 % of COD and colour removal respectively. Amount of current density is an important operation condition to electrodes. According to Atmaca (2009), since the current was applied to electrodes increases, production of Fe (II) required for Fenton oxidation becomes higher. Nevertheless, under high DC current applying, the efficiency may not change significantly while energy consumption of the method increased. From the results, there are closed readings each other of 150 A/m 2, 200 A/m 2 and 250 A/m 2. As expected, it was found that the removal efficiency increased with the increase of current density. However, after 200 A/m 2 the removal efficiency for COD and colour was decreased. COD removal increases when the high of current use but speed of the COD removal will be slow down when the current higher than 200 A/m 2. There is similar result with Atmaca (2009) and Zhang et al., (2006). This phenomenon was caused by the interfere reactions. However, interfere reactions can be reduced by using the proper Fe (II)/H 2 O 2 and Fe (III)/H 2 O 2 ratios and initial ph. According to Boye (2003) and Brillas et al., (2004) the decreased in current efficiency is because of the formation of hardly oxidizable products. Fig. 1: Effects of current density on COD and colour for Al-Al at ph 3, treatment time 30 minutes, H 2 O 2 600 mg/l, Fe 2+ 600 mg/l, distances between electrodes 5 cm and settling time 30 minutes. Optimum Treatment Time: Figure 2 were shown the optimum treatment time on the removal efficiency of COD and colour for Al- Al.The best removal efficiencies were obtained when treatment time is 25 minutes. COD and colour were achieved 73 % and 95 % removal respectively. The results showed that the removal efficiency of COD and colour has decreased when treatment time over than 25 minutes. Zhang (2007) has been investigated of hydrogen peroxide added in a single step and in a continuous mode with feeding time. From their results, the initial COD removal rate increased with the decreasing feeding time and it reached highest when hydrogen peroxide was applied all at once. Also that, the decrease of feeding time, the concentration of hydrogen peroxide during the initial period would increase. This phenomenon will be more hydroxyl radicals would be generated resulting from the chain reaction between hydrogen peroxide and ferrous ion. According to Lin and Chang (2000) the treatment time is to complete the oxidation reaction largely due to the dosage of H 2 O 2. In general, the time to terminate the electro- Fenton can vary significantly with the increases amount of H 2 O 2. Besides that, Zhang et al., (2006) was indicated the process of electro-fenton very fast in the first 15-30 minutes and then slowed down till it was complete in 75 minutes. 265

Fig. 2: Effects of treatment time on COD and colour removal efficiency for Al-Al at current density 200 A/m 2, ph 3, H 2 O 2 600 mg/l, Fe 2+ 600 mg/l, distances between electrodes 5 cm, and settling time of 30 minutes. Optimum Initial ph: In the electro-fenton process, ph is an important operation parameter on removal of COD and colour. The function of ph is to controls the production of the hydroxyl radical and the concentration of ferrous ions in the solution. Figure 3 were shown the optimum ph on the removal efficiency of COD and colour for Al-Al. The optimum ph was found at ph 4 which was achieved 74 % and 96 % of COD and colour respectively. From the results, the low removal COD and colour decreased at ph>4. It is similar by Lin and Chang (2000) were obtained the removal decreased for initial ph>4. From this results, it is clearly seen that ph 3, 4 and 5 is very closed each other on removal efficiency of COD and colour. In general, many researcher have been found that Fenton s reaction occur in low ph values between 2 and 4 (Mohajeri et al., 2010; Atmaca, 2009; Zhang et al., 2006; Gosh et al., 2011; Aziz et al., 2012; Lopez et al., 2004; Deng, 2007). When the ph value has been increased, the iron ions of Fe 3+ precipitate, which slow down the regeneration of ferrous ions. As a result, the amount catalyst of Fenton s reaction will be decreases. In fact, hydrogen peroxide is unstable in basic solution and possibly will itself rapidly decompose to water and oxygen as ph >5 (Mohajeri et al., 2010; Nidheesh and Gandhimathi, 2012). It is show that the stable hydroxyl radicals are produced at ph values of 2-4 and that high oxidizing potential was exhibited in this ph range ( Zhang, 2007; Badawwy and Ali, 2006). According to Zhang (2006) and Rivas et al., (2004) the ph>4, H 2 O 2 decomposes in a different manner without any contribution to oxidation reactions. Fig. 3: Effects of ph on COD and colour removal efficiency for Al-Al at current density 200 A/m 2, treatment time 25 minutes, H 2 O 2 600 mg/l, Fe 2+ 600 mg/l, distances between electrodes 5 cm and settling time of 30 minutes. Effect of H 2 O 2 Dosage: The dosage of H 2 O 2 is an important part in the electro-fenton process. The increased of H 2 O 2 concentration ability to remove more pollutants in wastewater. It is due to the increase in hydroxyl radical concentrations as a result of the addition of H 2 O 2. According to Zhang (2007) the efficiency of hydrogen peroxide for degrades 266

organic pollutants in the leachate decreased with the increase of Fenton s reagent dosage. At the high dosage of H 2 O 2, the decrease in removal efficiency was due to the hydroxyl radical scavenging effects of H 2 O 2 and the recombination of the hydroxyl radical. The results showed that the best removal efficiency of COD and colour is 800 mg/l of H 2 O 2 dosage which are obtained 78% and 97% of COD and colour removal respectively. It is seen that, the removal efficiency were increased when the dosage has been increased. However, a higher oxidant doses higher than optimum dose cannot provide adequate results. It is similar results reported by Ghosh et al., (2011). From their study, they were obtained 1530 mg/l of optimum H 2 O 2 dosage and a higher oxidant dose of 3825 mg/l did not lead to higher COD reduction. Fig. 4: Effects of H 2 O 2 dosage on COD and colour removal efficiency for Al-Al at current density 200 A/m 2, treatment time 25 minutes, ph 4, dose of Fe 2+ 1200 mg/l, distances between electrodes 5 cm and settling time of 30 minutes. Effect of Fe 2+ Dosage: In electro-fenton process, ferrous ion concentration is requirement to generate this process (Zhou et al., 2007). Figure 5 has been showed the effect of Fe 2+ concentration on removal of COD and colour. The optimum Fe 2+ concentration is 1000 mg/l for 75% of COD and 95% of colour removal respectively. Usually, the efficiency of electro-fenton process increases with Fe 2+ concentration because the concentration hydroxyl radical (Wang et al., 2010). The main oxidizing agent (H 2 O 2 ) in the electro-fenton process increases with the increase in Fe 2+ concentration. The excess of ferrous ion use in the electrolyte solution can consume the hydroxyl radicals and affect the extent of degradation (Nidheesh and Gandhimathi, 2012). After the electro- Fenton process the excess amount of Fe 2+ / Fe 3+ will be contamination for soil and groundwater because the excess amount of Fe 2+ / Fe 3+ produces extra amount of sludge and increase total dissolved solids and electrical conductivity. Fig. 5: Effects of Fe 2+ dosage on COD and colour removal efficiency for Al-Al at current density 200 A/m 2, treatment time 25 minutes, ph 4, dose of H 2 O 2 1200 mg/l, distances between electrodes 5 cm, and settling time of 30 minutes. 267

Conclusion: Optimum condition for electro-fenton process were found at current density 200 A/m 2, treatment time 25 minutes, ph 4, H 2 O 2 dosage 800 mg/l and Fe 2+ dosage 1000 mg/l. Hence, electro-fenton is recommended as a powerful technique for the degradation and decolorization of landfill leachate. ACKNOWLEDGEMENT The authors would like to acknowledge the Ministry of Higher Education Malaysia and Universiti Tun Hussein Onn Malaysia for financially supporting this study. REFERENCES Amuda, O.S., 2006. Removal of COD and Colour from Sanitary Landfill Leachate by using Coagulation Fenton s Process. J. Appl.Sci.Environ. Mgt, 10(2): 49-53. Atmaca, E., 2009. Treatment of Landfill Leachate by using Electro-Fenton method. Journal of Hazardous Material, 163: 109-114. Aziz, H.A., O.M. Othman, S.S. Abu Amr, 2012. The Performance of Electro-Fenton Oxidation in the Removal of Coliform Bacteria from Landfill Leachate, Waste Management. Badawy, M.I., M.E.M. Ali, 2006. Fenton s Peroxidation and Coagulation Processes for the Treatment of Combined Industrial and Domestic Wastewater, J. Hazard. Mater, 136: 961-966. Bohdziewicz, J., and A. Kwarciak, 2008. The Application of Hybrid System UASB Reactor-RO in LandfillLeachate Treatment, Desalination, 222: 128-134. Brillas, E., J.C. Calpe, J. Casado, 2000. Mineralization of 2, 4-d by Advanced Electrochemical Oxidation Processes, Water Res., 34: 2253-2262. Brillas, E., J. Casado, 2002. Aniline Degradation by Electro-Fenton and Peroxide-coagulation Processes using a Flow Reactor for wastewater Treatment. Chemosphere, 47: 241-248. Boye, B., M.M. Dieng, E. Brillas, 2003. Anodic Oxidation, Electro- Fenton and Photoelectro-Fenton Treatment of 2, 4, 5- trichlorophenoxyacetic acid. Journal of Electro analytical Chemistry, 557: 135-146. Brillas, E., B. Boye, I. Sir es, J.A. Garrido, R.M. Rodr ıguez, C. Arias, P.L. Cabot, C. Comninellis, 2004. Electrochemical Destruction of Chlorophenoxy Herbicides by Anodic Oxidation and Electro Fenton using a Boron-doped Diamond Electrode. Electrochim. Acta, 49: 4487-4496. Ghosh, P., A.N. Samanta, S. Ray, 2011. Reduction of COD and removal Zn 2+ from Rayon Industry Wastewater by Combined Electro-Fenton Treatment and Chemical Precipitation, Desalination, 266: 213-217. Deng, Y., 2007. Physical and Oxidative Removal of Organics during Fenton treatment of Mature Municipal Landfill Leachate. Journal of Hazardous Materials, 146: 334-340. Kraft, A., M. Stadelmann, M. Blaschke, 2003. Anodic Oxidation with Doped Diamond Electrodes: A New Advanced Oxidation Proces. J. Hazard. Mater, 103: 247-261. Li, W., Q. Zhou, T. Hua, 2010. Removal of Organic Matter from Landfill Leachate by Advanced Oxidation Processes: A Review, International Journal of Chemical Engineering. Lin, S.H., and C.C. Chang, 2000. Treatment of Landfill Leachate by Combined Electro fenton oxidation and Sequencing Batch Reactor Method. Water Resource, 34(17): 4243-4249. Liu. H., X.Z. Li, Y.J. Leng, C. Wang, 2007. Kinetic Modeling of Electro-Fenton Reaction in Aqueous Solution. Water Research, 41: 1161-1167. Lopez, A., M. Pagano, A. Volpe, A.C.D. Pinto, 2004. Fenton s Pre-treatment of Mature Landfill Leacahte. Chemosphere, 54: 1005-1010. Mohajeri, S., H.A. Aziz, M.H. Isa, M.A. Zahed, M.N. Adlan, 2010. Statistical Optimization of Process Parameter for Landfill Leachate Treatment using Electro-Fenton Technique. Journal of Hazardous Materials, 176: 749-758. Nidheesh, P.V. and R. Gandhimathi, 2012. Trends in Electro-Fenton Process for Water and Wastewater treatment: An Overview. Desalination, 299: 1-15. Rivas, F., F. Beltra, O. Gimeno, F. Carvalho, 2004. Fenton-like Oxidation of Landfill Leachate. Journal of Environmental Science and Health, 38(2): 371-379. Wang, C.T., W.L. Chou, M.H. Chung, Y.M. Kuo, 2010. COD removal from real dyeing wastewater by electro Fenton technology using an activated carbon fiber cathode. Desalination., 253: 129-134. Zhang, H., D. Zhang, J. Zhou, 2006. Removal of COD from Landfill Lechate by Electro-Fenton Method. J. Hazard. Mater, 135: 106-111. Zhang, H., C. Fei, D. Zhang, F. Tang, 2007. Degradation of 4-Nitrophenol in Aqueous Medium by Electro Fenton Method. Journal of Hazardous Materials, 145: 227-232. Zhou, M., Q. Yu, L. Lei, G. Barton, 2007. Electro-Fenton Method for the Removal of Methyl Red in an Efficient Electrochemical System. Separation and Purification Technology, 57: 380-387. 268