Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Similar documents
11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

11-SDMS-01 REV. 03 ( )

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

U.V resistance UL Sunlight Resistance. Flame retardant IEC

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Single core conductor BETAtherm 145

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

WIRES, CABLES AND CORDS

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

SafeX110 Single Core Flexible Tinned Copper Cable

40/69 kv to 127/220 kv XLPE

CATALOG. WIRE and CABLE. borderstates.com

Electrical Conductors Line

SPECIFICATION FOR FRLS POWER CABLES

P.V.C. INSULATED UNARMOURED COPPER CABLES

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC

RBT Cable for Industrial machinery

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems

MATERIAL STANDARD FOR CABLES AND WIRES

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

Wires & Cables for Space Applications

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media

Electric cables. CRANES APPENDIX

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

H-FLEX CABLES 10/2017

Tele-Fonika Cable Americas

project 36 MW 1.0 INTRODUCTION AND PROJECT INFORMATION

26/35kV Copper XLPE Insulation Electric Cable

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

AMENDMENT OF MALAYSIAN STANDARD MALAYSIAN STANDARD MS :2009

6A-51 DV wire (C rank)

Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES

Four Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Chapter ELECTRICAL CODE*

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

5.2 The phase conductors shall be provided with one, two & three ridges for easy identification.

6A V CVQ cable (C rank)

Construction guideline

Data sheet chainflex CF887

Excellent Integrated System Limited

Chapter ELECTRICAL CODE

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA

Technical Specification for Single Core 19/33kV Copper / TR-XLPE Underground Cable

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

Technical Specification for Substation 11kV and 22kV Single Core Underground Cable

*** Supercedes: BECO E and COM , , & ***

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

Armoured Instrumentation Cables to BS7917

Copper Cable Company Limited

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers

INDUSTRY. Welding Cables. Highly flexible, resistant and robust.

2. RATED VOLTAGE: The rated voltage of the AB cables shall be 1100 volts

America s Wire Company

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

MATERIAL STANDARD FOR ELECTRICAL HEAT TRACING ORIGINAL EDITION JAN. 1996

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

CONTENTS. B. System Design and Performance Requirements

Caledonian Cables Ltd

Kaf-Tech Product Specification

Separator, suitable tape between the braid and outer sheath

SECTION HORIZONTAL CABLING

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

JB/T Translated English of Chinese Standard: GB/T

International Tube & Conduit Company Ltd. GALVANIZING EDGE IN TUBE TECHNOLOGY

Cables ELE E L CT E C R T R IC I C A A L L

SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY)

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)

Compact Module. Enhanced Category 5 FTP Cabling System

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,

To enhance your building wire Jacketing with Ultramid

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Caledonian Industrial Cables. Italian Standard. CaledonianCables. Industrial Cables. Itanlian Standard. Addison. Addison

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Industrial Cable for Factory Automation

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Building Wire CARRYING YOUR ELECTRICITY

Transcription:

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Superastic Flex Extra sliding for extra easy installation. Superastic Flex cables are ideal for those who want to save installation time and resources, without disregarding the safety. Super flexible and extra sliding, in addition to assure greater speed and agility when installing, they exceed all the specifications of their category to protect circuits and installations. Application Superastic Flex cables are recommended in indoor installations for lighting, switchboards, panels and power supply points in general, in houses, residential, commercial, industrial buildings, etc. Description Electric cable, 450/750V, bare copper conductor, mild hardening, class 5, extra flexible, with insulation in double layer of PVC /A thermoplastic compound. Meets the standards: NBR NM 247-3 and NBR 5410. Reference Superastic Flex 750V (Section) mm² (Color) (#partnumber). Installation Conduit in insulating wall, conduit in closed channel, exposed conduit, raceway, conduit in vented channel, conduit in masonry and conduit in construction space. 2

1 2 Construction 1 CONDUCTOR Metal: Bare copper wires, mild hardening. Stranding: Class 5 - extra flexible. 2 INSULATION Double layer in PVC Antiflam. Maximum temperatures of the conductor 70 C in continuous service; 100 C under overload; 160 C in short-circuit. Differentiating features 20% more resistant to temperature, withstanding up to 85 C; Withstand twice the time under eventual overload; Reduce the risk of shortcircuit, potential generators of fire; Super flexible, Class 5, making handling and installation easier; Extra-sliding outer layer; Marking at every meter from section of 16 mm 2 ; Indelible ink printing, making the identification more legible. Applicable standards NBR NM 247-3: cables insulated with polyvinyl chloride (PVC) for nominal voltages up to 450/750V, inclusive Part 3: insulated (non-sheathed) conductors for fixed installations (IEC 60227-3, MOD). NBR 5410: Low-voltage electrical installations. Identification Superastic Flex cables have ink printing for identification. They are manufactured in double layer in colors: White, Black, Red, Gray, Green, Blue, Dark Blue, Brown, Yellow and Yellow/Green. Single-layer insulation in yellow-green color. Other colors upon consultation. 3

Superastic Flex 750V Part number Section (mm²) diameter conductor (mm) thickness insulation (mm) outer diameter (mm) weight (kg/km) Net weight of conductor (kg/km) Rcc (20ºC) (ohm/km) [1] Rca (70ºC) (ohm/km) [2] Voltage drop (fp =0.92) (V/A*km) [3] Current conduction capacity (A) [4] 23233YXX 1 1.3 0.6 2.5 14.1 8.5 19.5 23.3 43.0 14 23234YXX 1.5 1.5 0.7 2.9 19.2 11.6 13.3 15.9 29.3 1 7.5 23235YXX 2.5 1.9 0.8 3.5 30.0 19.2 7.98 9.54 1 7.6 24 23236YXX 4 2.4 0.8 4.0 43.9 30.9 4.95 5.92 10.9 32 23237YXX 6 3.0 0.8 4.6 61.7 46.5 3.30 3.95 7.3 41 23238YXX 10 3.9 1.0 5.9 105.0 80.3 1.91 2.28 4.2 57 23338YXX 16 5.5 1.0 7.5 160.8 126.7 1.21 1.45 2.7 76 23339YXX 25 6.2 1.2 8.6 247.7 196.5 0.780 0.934 1.7 101 23340YZZ 35 8.2 1.2 10.6 339.7 276.7 0.554 0.664 1.2 125 23341YXX 50 9.2 1.4 12.0 502.1 399.1 0.386 0.463 0.87 151 23342YXX 70 10.9 1.4 13.7 683.2 566.3 0.272 0.328 0.62 192 23343YXX 95 12.6 1.6 15.8 895.2 750.0 0.206 0.250 0.47 232 23344YXX 120 14.1 1.6 1 7.3 1123.9 959.6 0.161 0.197 0.38 269 23345YXX 150 16.0 1.8 19.6 1406.9 1197.6 0.129 0.159 0.31 309 23346YXX 185 1 7.5 2.0 21.5 1695.4 1457.5 0.106 0.133 0.26 353 23347YXX 240 20.0 2.2 24.4 2228.9 1932.6 0.0801 0.1037 0.20 415 23348YXX 300 24.4 2.4 29.2 2825.7 2451.6 0.0641 0.0864 0.17 477 [1] Ohmic resistance in direct current at ambient temperature of 20 C; [2] Ohmic resistance in alternating current at ambient temperature of 70 C; [3] Voltage drop calculation by considering power factor of 0.92 and trefoil cable arrangement; [4] Values extracted from standard NBR 5410 - installation method number 7, reference B1: insulated conductors or single-pole cables in round-section conduits embedded in masonry, for 2 charged conductors. Packaging Superastic Flex cables are packaged in: Box, Reel, Roll and Spool, according to the table below: Part number Section (mm²) Roll Reel Spool Box 23233YXX 1-23234YXX 1.5-23235YXX 2.5-23236YXX 4 23237YXX 6-23238YXX 10 - - 23338YXX 16 - - 23339YXX 25 - - Part number Section (mm²) Roll Reel Spool Box 23341YXX 50 - - - 23342YXX 70 - - - 23343YXX 95 - - - 23344YXX 120 - - - 23345YXX 150 - - - 23346YXX 185 - - - 23347YXX 240 - - - 23348YXX 300 - - - 23340YXX 35 - - *Other packages available upon consultation. 4

Packaging code table (Y) Roll Reel Spool Box 1 3 4 8 Color table (XX) Colors White Black Red Gray Green Light Blue Dark Blue Brown Yellow Yellow/ Green Code 01 02 03 04 05 06 07 08 09 14 Identify your cable model here! 23338YXX Color code Packaging code Standard part number for section of 16mm 2 Example: 23338402 Black color Spool packaging Standard part number for section of 16mm 2 5

PRYSMIAN GROUP Prysmian Cabos e Sistemas do Brasil S.A. Avenida Pirelli 1100 18103-085 - Sorocaba - SP - Brazil Sales Service +55 11 4998 4155 ofertas.energia@prysmiangroup.com Technical Service webcabos@prysmiangroup.com prysmiangroup.com.br Prysmian reserves itself the right of changing, without previous notice, the technical features, weights and dimensions presented in this catalog, always meeting the values prescribed in the standards mentioned. Prysmian does not assume any responsibility for personal or material damages resulting from improper and/or negligent use of the information contained in this catalog. We recommend the consultation to a certified professional for the correct sizing of your project. Images for illustration purposes only.