National Food Safety Standard

Similar documents
NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA (Zhenghua Renmin Gongheguo Guojia Biaozhun)

GB/T Translated English of Chinese Standard: GB/T

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

GB (GB/T )

Determination of sodium, calcium, copper, iron and manganese in pulp and paper by atomic absorption spectroscopy (Five-year review of T 266 om-11)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T223.

GB/T Translated English of Chinese Standard: GB/T

Analysis of Trace Metals in Tobacco and Tobacco Ash using Atomic Emission Spectroscopy

GB Translated English of Chinese Standard: GB

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Background The document will be revised for its five year review and updated per the committee agreed upon changes.

GB/T Translated English of Chinese Standard: GB/T

Background Statement for SEMI Draft Document 4795 (Yellow Ballot) NEW STANDARD: SPECIFICATIONS FOR NITRIC ACID, USED IN PHOTOVOLTAIC APPLICATIONS

Disclosure to Promote the Right To Information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

ISO INTERNATIONAL STANDARD

ELEMENTS by ICP 7301 (Aqua Regia Ashing)

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

IRON (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 600 C

Soil Sampling, Preparation and Analysis

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA


ICP-AES Determination of 15 Kind of impurity elements in the Vanadium-aluminum alloy

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

SEMI C SPECIFICATIONS AND GUIDELINES FOR AMMONIUM HYDROXIDE

Determination of Elemental Impurities in Graphite-based Anodes using the Agilent 5110 ICP-OES

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

GB/T Translated English of Chinese Standard: GB/T

Method for Estimation of Na 2 O and K 2 O in Ores, Fluxes, Coal and Coke Ash by Inductively Coupled Plasma-Atomic Emission Spectroscopy

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

» Talc is a native, hydrous magnesium silicate, sometimes containing a small proportion of aluminum silicate.

REPORT NUMBER REPORT DATE SEND TO ISSUE DATE Apr 18, Apr 18, 2017 RECEIVED DATE Apr 05, 2017

5-4 Chemical changes Trilogy

Multi-Element Analysis of Trace Metals in Animal Feed using ICP-OES

Calcium and Vitamin D with Minerals Samples: Standard solution and System suitability Tablets

Tap Water Analysis by Atomic Absorption and Ion Chromatography Michelle Youn Chem. 31: Inorganic Quantitative Analysis Section 6

INTERNATIONAL STANDARD

ELEMENTS by ICP 7301 (Aqua Regia Ashing)

Analysis of an OTC Multivitamin Tablet Using X-ray Fluorescence Spectroscopy and Atomic Absorption Spectroscopy

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

SEMI C SPECIFICATIONS AND GUIDELINES FOR HYDROGEN PEROXIDE

Improved Antimony Recoveries in Soil Matrices by 3050B/6010B. DataChem Laboratories, Inc. Robert P. Di Rienzo Jeffery S. Ward John T.

METHOD 7550 OSMIUM (ATOMIC ABSORPTION, DIRECT ASPIRATION)

METHOD #: Approved for NPDES and SDWA (Issued 1974) Mercury (Automated Cold Vapor Technique) ANALYTE: CAS # Hg Mercury

Background Statement for SEMI Draft Document 5134 Revision to SEMI C , Specifications for Hydrofluoric Acid

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

Determination of iron content in iron oxide used for fireworks and firecrackers based on Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF

Topic Reacting masses Level GCSE Outcomes 1. To calculate reacting masses 2. To set out mole calculations in a grid format

Standard Test Methods for Rubber from Natural Sources Chemical Analysis 1

Background Statement for SEMI Draft Document 4546A REVISION OF SEMI C , with title change to SPECIFICATIONS FOR HYDROGEN PEROXIDE

1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows

ISO INTERNATIONAL STANDARD

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE

Final Exam. Physical Constants and Conversion Factors. Equations

Methods for determination of mercury in LP gas

Composition Analysis of Animal Feed by HR ICP-OES

ISO INTERNATIONAL STANDARD

ELEMENTS by ICP 7303 (Hot Block/HCl/HNO 3 Digestion)

A Tap Water Analysis Study

2017 International Conference on Materials Science and Biological Engineering (ICMSBE 2017)

One of the main ores of zinc is zinc blende, ZnS. There are two stages in the extraction of zinc from this ore.

Photochemical studies of Eichhornia crassipes (Water Hyacinth)

DRAFT EAST AFRICAN STANDARD

by: Dr. Bob Lippert and Dr. Kathy Moore Which section of the lab would you like to visit?

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

ISO INTERNATIONAL STANDARD. Iron ores Determination of cobalt Flame atomic absorption spectrometric method

Standard Test Methods for Calcium and Magnesium In Water 1

ELEMENTS by ICP 7300 (Nitric/Perchloric Acid Ashing)

Standard Solutions (Traceable to NIST)

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Standard Test Methods for Zinc and Cadmium in Paper 1

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

Standard Solutions (Traceable to NIST)

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Fields of Application / Industry:

Your Technology Resource

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

Trace elements determination AAS

EDICT ± OF GOVERNMENT

METHOD #: Approved for NPDES and SDWA (Issued 1974) Mercury (Manual Cold Vapor Technique) ANALYTE: CAS # Hg Mercury

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

DETERMINATION OF IRON IN MILK POWDER BY MICROWAVE DIGESTION AND FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY

Method Metals by Inductively Coupled Plasma Atomic Emission Spectroscopy and Atomic Absorption Spectroscopy. September 1989

SPECIFICATIONS & TEST PROCEDURES ASPIRIN USP. Molecular Weight : Reference : USP 39

TITLE: SABS PROFICIENCY TESTING SCHEME, RSA

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

APPENDICES. Appendix 1. Length, weight and age (determined from otoliths) for burbot taken from Okanagan and Skaha lakes, 1971.

Flame Atomic Absorption Spectrometer (FAAS) Brand : PERKINALMER Model : PinAAcle 900T Custodian : PRADUP MESAWAT SOOKRUTHAI WONGSUBIN

Q1. From the following list of substances, choose the substances which meet the description given in parts (i) to (v) below :

R = kc Eqn 5.1. R = k C Eqn 5.2. R = kc + B Eqn 5.3

Measuring Manganese Concentration Using Spectrophotometry

NADUF: Methods of the chemical Analysis (EAWAG)

NADUF: Methods of the chemical Analysis (EAWAG)

ICSE-Science 2 (Chemistry) 2004

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 10/14/2014

Spectro-photometric determinations of Mn, Fe and Cu in aluminum master alloys

Transcription:

National standard of People s Republic of China GB 5413.21 2010 National Food Safety Standard Determination of calcium, iron, zinc, sodium, potassium, magnesium, copper and manganese in foods for infants and young children, raw milk and dairy products Issued at 2010-03-26 Implemented 2010-06-01 Issued by the Ministry of Health, People s Republic of China

Preface This standard replace GB/T5413.21-1997, Measurement of calcium, ferrum, zinc, sodium, potassium, magnesium, copper and manganese in formulated foods and milk powder for infants and young children The main changes in this standard compared with GB 5413.21-1997 are as following: --Certified reference stock can be directly purchased in method 1 --The preparation standard stock solution and standard working solution in method 1 --The dilution steps for sample preparation in method 1. --Add the second measurement method of inductively coupled plasma atomic emission spectrometry. Versions of standard substituted by this standard are: --GB 5413-1985 GB/T 5413.21-1997.

GB Determination of calcium, ferrum, zinc, sodium, potassium, magnesium, copper and manganese in food for infants and young children and dairy products 1 Scope This standard regulate the method for the determination of calcium, ferrum, zinc, sodium, potassium, magnesium, copper and manganese in food for infants and young children and dairy products. This standard applies to the determination of calcium, ferrum, zinc, sodium, potassium, magnesium, copper and manganese in food for infants and young children and dairy products. 2 Normative cited documents The reference cited in this standard is necessary. For the cited documents which are labeled with date, all their subsequent modification sheets or modified versions are not applicable for this standard. For the cited documents which are not labeled with date, their latest versions are applicable for this standard. 3 Principle Method 1 Atomic absorption spectrometry Dry ash the samples to break down organic part. Dissolve the inorganic ions in the ash by acid. Aspirate into air-acetylene flame for atomization. Measure absorbance under specific wavelength. When measuring calcium and magnesium, lanthanum should be added as releasing agent to eliminate the interference by phosphoric acid. 4 Reagents and materials Unless additionally specified, the reagents used by this method are GR, and water is the second grade water specified by GB/T6682. 4.1 Hydrochloric acid 4.2 Nitric Acid 4.3 Lanthanum solution 4.4 Potassium chloride, molecular weight: 74.55, chromatography grade 4.5 Sodium chloride, molecular weight: 58.44, chromatography grade 4.6 Calcium carbohydrate: molecular weight: 100.05, chromatography grade 4.7 Purified magnesium, chromatography grade 4.8 Purified zinc, chromatography grade 4.9 Iron powder, chromatography grade 4.10 copper, chromatography grade 4.11 Manganese, chromatography grade 4.12 Hydrochloric acid A(2%): Dilute hydrochloric acid 2ml (4.1) to 100 ml with water. 4.13 Hydrochloric acid B(20%): Dilute hydrochloric acid 20 (4.1) to 100 with water. 4.14 Nitric acid (50%): Dilute 20 nitric acid (4.2) to 100 with water. 4.15 Lanthanum solution (50g/L): weigh 29.32g lanthanum oxide (4.3) and wet with 25 deionized water. Slowly add 125 hydrochloric acid (4.1) and dissolve the lanthanum oxide. Dilute with deionized water to 500. 4.16 Potassium standard stock solution (1000 ): Weigh 1.9067g of dried potassium chloride (4.4), Dissolve in hydrochloric acid A (4.12) and dilute to 1000 ml in volumetric flask. 4.17 Sodium standard stock solution (1000 ): Weigh 2.5420g dried sodium chloride (4.5)

Dissolve in hydrochloric acid A (4.12) and diluted to 1000 in volumetric flask. 4.18 Calcium standard stock solution (1000 ): Weigh 2.4963g dried sodium chloride (4.6) Dissolve in 100 ml hydrochloric acid B (4.13) and diluted to 1000 in volumetric flask. 4.19 Magnesium standard stock solution (1000 ): Weigh 1.0000g purified magnesium (4.7) Dissolve in 40 ml nitric acid (4.14) and diluted to 1000 in volumetric flask. 4.20 Zinc standard stock solution (1000 ): Weigh 1.0000g purified zinc (4.8).Dissolve in 40 ml nitric acid (4.12) and diluted to 1000 in volumetric flask. 4.21 Iron standard stock solution (1000 ): Weigh 1.0000g iron powder (4.9).Dissolve in 40 ml nitric acid (4.12) and diluted to 1000 in volumetric flask. 4.22 Copper standard stock solution (1000 ): Weigh 1.0000g copper (4.10).Dissolve in 40 ml nitric acid (4.12) and diluted to 1000 in volumetric flask. 4.23 Manganese standard stock solution (1000 ): Weigh 1.0000g manganese (4.11).Dissolve in 40 ml nitric acid (4.12) and diluted to 1000 in volumetric flask. 4.14 Standard stock solutions of different elements Standard stock solutions of calcium, iron, zinc, sodium, potassium and magnesium: pipette 10.0 standard solution of calcium(4.18), iron (4.21), zinc (4.20) and potassium (4.16), 5.0 standard solution of sodium (4.17) and 1.0 magnesium standard solution (4.19) into 100 quartz volumetric flask and make up to the mark with hydrochloride acid solution A (4.12) to obtain the standard stock solution of the above different elements. Concentration for calcium, iron, zinc, potassium is 100.0µg/; sodium: 50.0µg/; magnesium:10.0µg/ Standard stock solutions of manganese and copper: accurately Pipette 10.0 manganese standard solution (4.23) into 100 ml volumetric flask and make up to the mark with hydrochloric acid A(4.12), from which 4.0 is diluted with hydrochloric acid A (4.12) to 100 to obtain manganese stock solution. Accurately pipette 10.0 copper standard stock solution (4.22) into 100 ml volumetric flask and make up to the mark with hydrochloric acid A(4.12), from which 6.0 is diluted with hydrochloric acid A (4.12) to 100 to obtain copper stock solution.concentration is: manganece: 4.0µg/; copper: 6.0µg/. 5 Equipments and devices: 5.1 Atomic absorption spectrometer 5.2 Hollow cathode lamps of calcium, iron, zinc, sodium, potassium, magnesium, copper and manganese 5.3 Acetylene gas and air compressing engine 5.4 Quartz crucible or porcelain crucible 5.5 Muffule furnace 5.6 Balance: nearest to 0.1mg.

6 Analysis steps 6.1 Sample preparation Approximately weigh 5g of well-mixed solid sample or 15g (nearest to 0.0001g) in crucible (5.4) and carbonize on electric furnace with low powder until no black smoke. Heat in Muffule furnace (5.5) under 490 until the sample becomes white ash. If there are any black carbon granules, add drops of nitric acid (4.14) after cooling down. Evaporate on the electric furnace using low power and put into 490 muffule furnace again to be incinerated to white ash. After sample is cooled to room temperature, add 5 hydrochloric acid B(4.13), heat on the electric furnace to make the ash thoroughly dissolved. The sample is cooled down to room temperature and moved to 50 volumetric flask and make up to the mark with water. At the same time, at least two blank control is prepared at the same time. 6.2 Testing solution preparation of samples 6.2.1 Ca, Mg testing solution Pipette 1.0 ml accurately from 50 solution (6.1) into 100 ml volumetric flask. Add 2 ml Lanthanum solution (4.15). Make up to the mark with water. Same operation to blank solution 6.2.2 Na testing solution Pipette 1.0 ml accurately from 50 solution (6.1) into 100 ml volumetric flask. Make up to the mark with hydrochloride acid solution A (4.12). Same operation to blank solution 6.2.3 K testing solution Pipette 1.0 ml accurately from 50 solution (6.1) into 100 ml volumetric flask. Make up to the mark with hydrochloride acid solution A (4.12). Same operation to blank solution 6.2.4 Testing solution for Fe, Zn, Mn and Cu 50 ml solution (6.1) directly aspirate to the AAS. At the same time blank control solution is measured. 6.2.5 In order to make sure concentration of testing solution fall into the range of standard curve, dilution volume can be adjusted. 6.3 Determination 6.3.1 Preparation of standard curve 6.3.1.1 Preparation of standard series dilutions According to the volume listed in table 1, pipette standard stock solutions of iron, zinc, sodium, potassium, manganece and copper into 100 volumetric flask. Make up to the mark with hydrochloric acid (4.12). Pipette accurately standard stock solution of Ca and Mg into volumetric flasks and make up to the mark with water. The standard working solutions of different concentrations for different elements are prepared, concentrations are listed in table 2. Table 1 Volume of standard intermediate solutions for different elements required for the preparation of standard series dilutions Number K Ca Na Mg Zn Fe Cu Mn 1 1.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2 2.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3 3.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 4 4.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 5 5.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0

Table 2 Concentrations of standard series dilutions for different elements Number K Ca Na Mg Zn Fe Cu µg/ Mn 1 1.0 2.0 1.0 0.2 2.0 2.0 0.12 0.08 2 2.0 4.0 2.0 0.4 4.0 4.0 0.24 0.16 3 3.0 6.0 3.0 0.6 6.0 6.0 0.36 0.24 4 4.0 8.0 4.0 0.8 8.0 8.0 0.48 0.32 5 5.0 10.0 5.0 1.0 10.0 10.0 0.60 0.40 6.3.1.2 Plotstandard curve Optimize working condition of equipment according to the equipment manual Select the sensitive absorption lines K 766.5nm Ca422.7nm Na589.0nm Mg285.2nm Fe248.3nm Cu324.7nm Mn279.5nm Zn213.9nm. After the equipment is adjusted, set zero point with hydrochloric acid (4.2) aspirated with capillary tube for measurement of iron, zinc, sodium, potassium, copper and manganese. When measuring calcium and magnesium, first pipette 2.0 lanthanum solution (4.15) and diluted to 100 with water. This solution is used to set zero point through capillary tube. Measure absorbance of standard working solution. Plot the Standard curve using concentrations of standard series solution as X-axis and corresponding absorbance as Y-axis. 6.3.2 Determination of sample solutions Optimize working condition of equipment, hydrochloric acid (4.2) is used for zeroing in the measurement of iron, zinc, sodium, potassium, copper and manganese. In the measurement of calcium and magnesium, 2.0 lanthanum solution (4.15) is diluted to 100 with water to make the solution for zeroing. Absorbance of sample solution and blank solution is measured according to the following steps. Corresponding mass concentration is obtained from standard curve. 7 Result expression The content of calcium, magnesium, sodium, potassium, iron and zinc (X) is expressed as mg/100g, and calculated using equation (1): In the equation: X content of elements in the samples, mg/100g; C1 concentration of elements in the samples, µg/; C2 concentration of elements in the blank solution, µg/; V volume of the sample solution, ; A dilution times of the sample solutions; m mass of the samples, g. The content of calcium, magnesium, sodium, potassium, iron and zinc (X) in the samples is expressed as mg/100g, and calculated using equation (2): In the equation:

X content of elements in the samples,µg/100g; C1 concentration of elements in the samples, µg/; C2 concentration of elements in the blank solution,µg/; V volume of the sample solution, ; A dilution times of the sample solutions; m mass of the samples, g. The result is expressed as the arithmetic mean value of two independent measurements. The calculation results of calcium, magnesium, sodium, potassium, manganese and copper need to be accurate to one digit after the decimal point. For iron and zinc, the result is required to be accurate to two digits after the decimal point. 8 Precision The absolute difference between two independent measurements performed under repeatability conditions should not exceed 15% of the arithmetic mean value. The second measurement method of inductively coupled plasma atomic emission spectrometry 9 Principle Sample is incinerated and digested using dry method, and measured with inductively coupled plasma atomic emission spectrometry after diluted to appropriate volume. External reference method is used for quantification. 10 Reagents and materials Unless additionally specified, the reagents used by this method are GR, and water is the first grade water specified by GB/T6682. 10.1 Hydrochloride acid 10.2 Nitric acid solution 10.3 Nitric acid solution (50%): dilute 50 ml (10.2) nitric acid to 100 ml with water. 10.4 Hydrochloric acid solution A (4%): dilute 4 ml (10.1) nitric acid to 100 ml with water. 10.5 Hydrochloric acid solution B(40%): dilute 40 ml (10.1) nitric acid to 100 ml with water. 10.6 Standard stock solution of 8 elements: Standard stock solution of single element can be prepared using method specified in GB/T602 or using certified reference material.concentration is 1.0 mg/ (or 0.5 mg/). 11 Equipments and devices: 11.1 Inductively coupled plasma atomic emission spectrometry 11.2 Analytic balance: accuracy is 1mg. 11.3 Muffle furnace 11.4 Electric furnace:1~2 kw. 11.5 Porcelain crucible 12 Analysis Procedure 12.1 Sample preparation If Samples are powder and should be mixed well before analysis. If samples are granules with bigger size, then some samples should be crashed or grinded before measurement. 12.2 Sample preparation Weigh 5g samples (nearest to 1mg) into porcelain crucible and carbonize on electric furnace using low power until no smoke can be seen. Ash in muffule furnace at 550 for 2 hours. If there are any black carbon granules, drops of nitric acid (10.1) is added after cooling down. Evaporate on the electric furnace using low power and ash in muffle furnace at 490 for 0.5 hour. Cool down and add 5 ml of Hydrochloric acid solution B (10.5) Heat on the electric furnace to completely dissolve the ashes. After cooling down, the sample is moved to 25

volumetric flask and make up to the mark with water. If there are any precipitates, the solution should be filtered. 12.3 Parallel experiment The same sample is measured in parallel according to the above steps. 12.4 Blank experiment Only no sample is added, all other steps are carried out according to the sample processing and measurement steps. 12.5 Reference operation condition of equipments Power: 1.20 kw, Plasma gas flow rate: 15L/min, Pressure of the atomizer: 200kPa, Assistant gas flow rate: 1.50L/min, Stable time lag: 15s, Sample injection time lag: 20s, Frequency of reading: 3 times, Recommended analytical spectral lines of elements are listed in table 1: Table 1 Recommended analytical spectral lines of elements Unit is nanometer Element Wavelength of analytical spectral lines Ca 315.887, 317.933 Mg 279.553 280.270 Fe 234.350 238.204 259.940 Mn 257.610 Cu 324.754 327.395 Zn 202.548 206.200 K 766.491 Na 588.995 589.592 12.6 Preparation of mixed standard solution Mixed standard solutions, whose concentrations are listed in the following table, is prepared from stock solution after series dilution with hydrochloric acid solution A (10.4). Table 4 Element concentrations of mixed standard solution Serial number Ca Mg Fe Mn Cu Zn K Na 1 0 0 0 0 0 0 0 0 2 10.0 0.5 5.0 0.1 0.2 5.0 10.0 1.0 3 15.0 1.0 10.0 0.2 0.4 10.0 20.0 3.0 4 20.0 1.5 15.0 0.3 0.6 15.0 30.0 5.0 5 25.0 2.0 20.0 0.4 0.8 20.0 40.0 7.0 12.7 Determination Optimize the Equipment with reference to condition listed in 12.5. Measure standard solution, blank solution and samples in turn. If concentration of certain element exceeded the standard curve, sample solution can be measured after diluted with hydrochloric acid solutiona (10.4). 13 Result expression Element content is calculated according to equation (3): In the equation X content of elements in the samples, mg/100g; C1 concentration of elements in the samples, µg/; C2 concentration of elements in the samples, µg/; V volume of the sample solution, ; A dilution times of the sample solutions; m mass of the samples, g.

The result is expressed as the arithmetic mean value of two independent measurements. Report results to 3 effective digit 14 Precision The absolute difference between two independent measurements performed under repeatability conditions should not exceed 10% of the arithmetic mean value. 15 Others Detection limit for Method I Ca: 1.0 mg/100g, Mg: 0.3mg/100g, Fe: 0.02mg/100g, Mn: 0.001mg/100g, Cu: 0.0045mg/100g, Zn: 0.02mg/100g, K:0.2mg/100g, Na: 1.5mg/100g Detection limit for Method II Ca: 0.7 mg/100g, Mg: 0.2mg/100g, Fe: 0.003mg/100g, Mn: 0.005mg/100g, Cu: 0.002mg/100g, Zn: 0.002mg/100g, K:0.7mg/100g, Na: 1.6mg/100g