AORC Technical meeting 2014

Similar documents
ISSN Vol.09,Issue.04, March-2017, Pages:

DISTRIBUTED GENERATION AND POWER QUALITY

Capacity and Location Effects of Wind Turbine Energy Systems on Power Systems Stability

ISSN Vol.07,Issue.16, November-2015, Pages:

Hybrid Wind-Diesel Generation System

Comparative Analysis between IG and DFIG for Wind Energy Conversion Systems using STATCOM

Design and Modeling of Wind Energy Conversion System Based on PMSG Using MPPT Technique

CENTRE FOR WIND ENERGY TECHNOLOGY CHENNAI INDIAN WIND GRID CODE

Adjustable Speed Hydro Generation

Control of a Microgrid in Islanded Mode

Impacts of the Decentralized Wind Energy Resources on the Grid

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Power Flow Control Scheme for Wind Energy Conversion System

IMPACT OF THE WIND POWER PLANTS TO THE SETTING OF STEP 2 DISTANCE PROTECTION

Power Quality Improvement in Distribution System Using Distribution Static Compensator

Study on the Application of Advanced Power Electronics in Smart Grid

Varspeed Pump Storage Power Plants: Technology and Operation

MODELING AND SIMULATION STUDY OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND TURBINE SYSTEM IN MICRO-GRID APPLICATION

A Power Quality Improvement for Microgrid Inverter Operated In Grid Connected and Grid Disconnected Modes

WIND ENERGY GENERATION

Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25, 2012

EFFECT OF WIND SPEED VARIATIONS ON WIND GENERATOR OUTPUT IN TROPICAL CLIMATE WEATHER CONDITION

Comparative Analysis of Wind Energy Conversion System using DFIG and IG

WIND ENERGY CONVERTERS AND SOME ASPECTS OF POWER QUALITY

Master Thesis Department of Electrical Engineering. The Effect of a Short- Circuit Current in a High Voltage Installation With a Synchronous Machine.

Enhancement of power quality of Grid connected wind energy system using STATCOM

Real-time Cosimulations for Hydropower Research and Development

Refinement of Hydel power by implementing FACTS at Narangwal hydroelectric power plant

All Rights 1

SYNOPSIS OF THE THESIS. Enhanced Power Quality Management of Grid Connected Wind Farm

AGGREGATED MODELLING ANALYSIS OF POWER FLOW FROM WIND POWER PLANT INTO GRID SYSTEM USING MATLAB/ SIMULINK SOFTWARE

GE Energy. Power Conversion. Offshore Renewable Energy Porto May We re at work making change happen

ENABLING FREQUENCY AND VOLTAGE REGULATION IN MICROGRIDS USING WIND POWER PLANTS

Impact of Different Types of Wind Turbines Generators on Voltage Sag

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw)

STUDY AND ANALYSIS OF WIND TURBINE FOR POWER QUALITY ASSESSMENT

Utility Integration of Wind Energy Systems. Prof. Dr. Ali M. Eltamaly SET Center, King Saud University

Modeling and Control of MPPT Based Grid Connected Wind-PV Hybrid Generation System

Economic Selection of Generators for a Wind Farm

Technical and economical analysis of the wind turbines interconnection with the windfarm substation

Different Options for Multi-Rotor Wind Turbine Grid Connection

Wind Farms in Weak Grids Compensated with STATCOM

MEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM

GATE SOLUTIONS. From ( ) Office : F-126, (Lower Basement), Katwaria Sarai, New Delhi Phone :

Modeling of Wind Power Plant with Doubly-Fed Induction Generator

Voltage Quality Improvement Using Solar Photovoltaic System

ECE 333 GREEN ELECTRIC ENERGY. 6. Limits on Conversion of Wind Into Electricity

Renewable Energy in Power Systems

Operation of Power Systems with High Shares of Variable Renewables. Manuel Coxe. Progarmme Officer - Grid Integration

POWER QUALITY IMPROVEMENT FOR GRID CONNECTED WIND ENERGY SYSTEM USING UPFC

Grid Power Quality Improvement and Battery Energy Storage in Wind Energy System by PI and Fuzzy Based STATCOM Controller

Planning the Interconnection of Islands to the Mainland Grid via Submarine Cables

Applied Energy 87 (2010) Contents lists available at ScienceDirect. Applied Energy. journal homepage:

Analysis of Wind Power Integration for Power System Transient Stability

Mitigation of Voltage Fluctuations in Power System Using STATCOM

Army Sustainability Workshop

RESEARCH ON THE VIRTUAL SYNCHRONOUS GENERATOR CONTROL STRATEGY OF GRID-CONNECTED PERMANENT-MAGNET DIRECT-DRIVEN WIND POWER SYSTEM

Shunt Active Power Filter Wind Energy Conversion System

Harnessing Renewables in Power System Restoration

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

HEAD TANK (FOREBAY TANK)

Wind-Solar-Hydel Cogeneration Systems in Remote Areas

The Simulation And Control Of A Grid-connected Wind Energy Conversion System

VFDs driving the boiler feed water pump of #11-13 Combined Cycled Generation Unit in Yangpu Thermal Power Plant by Bin Li

Effects of Unbalanced Faults on Transient Stability of Cogeneration System

ISSN MIT Publications

Effects of Renewable Distributed Generation on the Operational Characteristics of Meshed Power Distribution Systems

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw)

Modelling of a PMSG Wind Turbine with Voltage Control

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION

STATCOM for Improved Dynamic Performance of Wind Farms in Power Grid

Analysis of DG Influences on System Losses in Distribution Network

POWER QUALITY IMPROVEMENT OF A GRID CONNECTED WIND ENERGY SYSTEM USING STATCOM-CONTROL

Experimental Study of Transducer Harmonics Effect on Pump Unit Energy Consumption

3. Design of Generation Equipment. 3.1 Turbine (1) Turbine Types Turbines are classified into two types according to their water energy utility:

ADVANCES in NATURAL and APPLIED SCIENCES

ELG4126 Distributed Generation and Renewables

Power Quality and Voltage Stability of Power Systems with a large share of Distributed Energy Resources

M.E POWER ELECTRONICS AND DRIVES Course Outcome R2009 ( BATCH)

Large Hydro ensuring Grid Stability with rapidly expanding Wind Generation

Generation Application Part B: Technical Form

Critical Load Serving Capability by Microgrid using 100% Renewable Energy

California Independent System Operator Renewable Integration Study

8 th Annual Electric Power Industry Conference

STOCKAGE HYDRO. 7 decembre 2018

Harmonic Reduction and Power Transmission Enhancement in a Grid Interface of Wind Power Using Shunt-Connected FACTS Device

IMPROVEMENT OF POWER QUALITY IN WIND ENERGY SYSTEM USING STATCOM

Connection Study Requirements

Reduction of Harmonics in Microturbine Generation System

R2 TESTING GUIDELINE. PREPARED BY: Network Models Systems Capability VERSION: Final RELEASE DATE: 28 June 2013

EMTP Modeling of Cogeneration System for Transient Stability Analysis

A REVIEW ON POWER CONTROL SYSTEM INVERTERS WITH VARIATION POWER SYSTEM

Strathprints Institutional Repository

Renewable Integration in India

ReliabilityFirst Regional Criteria 1. Verification and Data Reporting of Generator Gross and Net Reactive Power Capability

Emulation of a Wind Turbine with a DC Motor controlled by Fuzzy Logic controller

2012 Grid of the Future Symposium. The Role of HVDC for Wind Integration in the Grid of the Future

Lesson Learned Loss of Wind Turbines due to Transient Voltage Disturbances on the Bulk Transmission System

Operation and performance of grid-connected solar photovoltaic power system in Kocaeli university

Solar PV, Wind, and Storage System Design. Ilya Chernyakhovskiy, NREL April 26, 2018 Dushanbe, Tajikistan

Transcription:

http : //www.cigre.org B4-053 AORC Technical meeting 204 Optimized Operation of Hydropower Plant with VSC HVDC Unit Connection Xiaobo Yang, Chao Yang, Chengyan Yue, Dawei Yao, Chunming Yuan Corporate Research, ABB (China) Limited China SUMMARY Among various renewable sources, hydropower is still the cheapest clean energy. As most of the new constructed hydropower plants are located at remote areas, HVDC lines are usually employed for hydropower transmission. In this paper, hydropower plant with VSC HVDC unit connection is proposed, in which the generator(s) of a hydropower station is connected to a voltage source converter (VSC) station directly and the power is transmitted by DC line. By using VSC HVDC unit connection, the hydraulic turbine realizes variable speed operation and thereby improves the hydraulic turbine efficiency substantially. In the paper, the progress of hydropower unit connection is reviewed and a typical configuration of hydropower plant with VSC HVDC station unit connection is introduced; the advantages of employing VSC HVDC unit connection technology are presented. A calculation model is established to calculate the maximum hydraulic turbine efficiency. Finally, the turbine efficiencies are compared between the variable speed operation of hydropower plant with VSC HVDC unit connection and fixed speed operation of a conventional hydropower plant; the power frequency variation range during variable speed operation is analyzed. KEYWORDS DC rid- HVDC- Hydropower- Unit Connection- Variable Speed- VSC HVDC xiaobo.yang@cn.abb.com

. Introduction The synchronous generators used in the conventional hydropower plants are usually operated to match the rated power frequency of integrated AC grid, i.e. 50 Hz or 60 Hz. The turbines are also designed to run at the speed specified by the frequency, under rated hydraulic head and power. It means that the design and control of hydropower plant are strictly constrained. Any deviations of hydraulic head or power order will result in decrease of efficiency. However, if the rotating speed of turbine can be adjusted, the efficiency of hydropower generation will be increased significantly. It is estimated that by applying appropriate variable speed control to the hydraulic turbines, the annual average efficiency of the power plant can be increased from 2% to 5%, the larger the water head may change, the higher the efficiency can be increased []. Variable speed operation of hydropower plant results in a substantial improvement in system efficiency and performance. It also brings benefits from additional control flexibility, optimized reservoir siting, less environmental impact, relaxed turbine design parameter and hydraulic turbine service time, etc. By far, there are basically 3 solutions in terms of variable speed operation of hydropower plant, namely based on doubly fed induction generator, full power converter and HVDC converter station, respectively.. Hydropower plant with doubly fed induction generator The adjustable speed operation of hydraulic turbine can be achieved by using doubly fed induction generator (DFI). Today, two converter technologies for DFI control are available, viz. thyristor based cycloconverter and forced turn-off device based PWM converter, as shown in Figure (a) and (b) respectively. Although the power of cycloconverter or the PWM converter connected to the generator is only a part of the rated generation power (depending on the variable speed range requirement), the DFI is an expensive wound rotor asynchronous machine. Therefore existing commercialized DFIs are only installed for pumped storage power plants which have relatively small power. AC grid Smoothing reactor Pw Pm Asynchronous generator Rectifier (a) DFI with cycloconverter Inverter AC grid Pw Pm Capacitor Asynchronous generator Rectifier Inverter (b) DFI with PWM converter Figure Hydro power plant with DFI for variable speed operation.2 Hydropower plant unit connection with a back-to-back full power converter Figure 2 shows a hydropower plant with connection of a back-to-back full power PWM converter (FPC). In past years, ABB had commissioned two FPC systems for pumped storage power plants (60MW Panjiakou pumped storage, China, 99 and 4 265MW oldisthal pumped storage, ermany, 2004). By using FPC, the generator is fully decoupled from the AC grid. The nominal power of the generator can be reduced because the additional capacity for negative sequence component during grid fault is not needed. The whole system performance is also improved because of the decoupled control of active power and reactive power at grid side converter.

AC grid Pw Pm Capacitor enerator Turbine Rectifier Inverter Figure 2 Hydro power plant with full power PWM converter.3 Hydropower plant unit connection with HVDC converter station Nowadays, more and more HVDC lines are employed for hydropower transmission due to most of the new constructed hydropower plants are located at remote areas. The coordination of hydropower plant and HVDC converter station brings the possibility to develop variable speed operation technologies for considerably large hydraulic turbines at conventional hydro power plant without additional investment. The direct connection of hydropower plant and HVDC was referred to unit connection in some earlier literature [8, 2, 5]. A typical hydro power unit connection scheme with line commutated converter HVDC (LCC HVDC) is shown in Figure 3, in which a is the guide van opening and n is the turbine speed. overnor a Hydrolic Turbine n Synchronous Machine uabc Converter Transformers + HVDC converter station AC grid uabc Excitation System Aux. Power supply Unit Connection Figure 3 Hydropower plant unit connection with LCC HVDC Hydropower plant unit connection with HVDC was firstly presented by Brown Boveri & Cie (BBC) in 973 [2], but the turbine was assumed to operate at a fixed speed. Since 980s, many literatures had proposed HVDC converter station for adjustable speed operation of hydropower plant [3-2], including variable speed pumped storage power application [3, 4], harmonic measurement and analysis of generator [6, 0, ] and unit connection system design [7, 9,, 2, 5]. In all these papers, only LCC HVDC system for hydro power unit connection was studied. The applications of VSC HVDC for hydropower unit connection were rarely discussed, because the capacity and voltage rating of VSC HVDC were thought as major limitations for transmission level application. However, in recent years, the VSC HVDC technology has been developed significantly and its application has been extended from sub-transmission and distribution level to transmission level. In 2008, a short discussion on application of VSC HVDC technology in hydropower exportation was published [3], while no in depth information, such as circuit topology, control and protection scheme, has been introduced. In this paper, hydropower plant with VSC HVDC unit connection is addressed. Firstly, the advantages of employing VSC HVDC unit connection technology are presented in Section 2; then in Section 3, a calculation model is established to calculate the maximum hydraulic turbine efficiency; finally, the turbine efficiency of variable speed operation is compared with that of fixed speed operation, based on a typical conventional hydropower plant. The frequency variation range during variable speed operation is also analyzed, to investigate the requirement on the generator circuit breaker. 2. Hydropower plant with VDC HVDC unit connection A VSC connected hydropower plant to DC grid will give fully advantages of variable speed operation of turbines and bring additional commercial interests. The hydropower plant with direct VSC HVDC connection can be regarded as a DC source in the DC grid, in which the DC voltage and DC power will be adjusted according to the power order from the dispatch center of the DC grid. Further, it s - 2

possible to connect several hydropower plants into one DC grid. This is particularly profitable when several hydropower plants are located along one river and cascaded constructed. The hydropower plant with VSC HVDC unit connection is proposed as shown in Figure 4. Hydrolic Turbine a overnor a* Synchronous Machine VSC HVDC Unit Connection n u abc Excitation System I exc* VSC HVDC Converter Station Converter Transformers u abc Power plant controller U dc_ref + - Pord U dc Hydraulic head DC grid Figure 4 Hydropower plant with VSC HVDC unit connection and its integration to the DC grid The major advantages of hydropower plant with VSC HVDC unit connection come from variable speed operation of hydropower plant, as listed below: Significant energy savings because of higher efficiency of hydraulic turbine; Longer life time of turbine thanks to reduced noise, vibration and cavitation problems; New flexibility in site selection and sizing of hydro units; Relaxation of parameter requirements on turbine design; Fast generation control for wind/solar power integration; Less environmental impacts, etc. Figure 5 Hill Chart curves of a normalized Francis type turbine The characteristic of variable speed operation with higher efficiency can be explained by the so called Hill Chart curve. Figure 5 presents the Hill Chart curve of a Francis type hydraulic turbine [4], in which is the unit water flow quantity and is the unit hydraulic turbine speed. In this example, for the constant rotating speed operation of the hydraulic turbine at certain water head, the efficiency of the turbine will decrease from 89% to 87% (point A to B) when unit flow changes from about 0.62 m 3 /s to 0.55 m 3 /s. In contrast, with variable speed operation, approximately 2% efficiency increase is obtained by adjusting the turbine speed from 69 r/min to 62 r/min (Point B to C) under the same flow quantity. Consequently, the adjustable speed of turbine permits a maximum efficiency tracking. 3. Calculation model for operation optimization Based on the Hill Chart in Figure 5, a calculation model for the Francis turbine is established to calculate the maximum efficiency from variable speed operation of hydropower plant with VSC HVDC unit connection. The model consists of the following calculation sections: 3

[m 3 /s] [r/min] ) Unit power P : P P / ( H D ), () 3 2 e where P is the electric power; η e is the efficiency of generator; H is the water head and D is the nominal diameter of hydraulic turbine. 2) Maximum efficiency curve f : f ( Q ), (2) H max where is the maximum turbine frequency, which is a variant of unit flow quantity The curve is obtained from the turbine Hill Chart. 3) Maximum Power curve f 2 The unit flow quantity Q for given unit power P can be expressed as Considering (2), Hmax Q. Q P / 9.8. (3) P becomes function of Q : P 9.8 Q f ( Q ) f ( Q ) (4) 2 Then Q can be obtained from inverse function of (4): Q f2 ( P ). (5) 4) uide opening curve f 3 : a0 f3( Q ), (6) where a 0 is the guide van opening angle. The curve is obtained from the turbine Hill Chart. 5) Efficiency peak curve f 0 n f0(q ), (7) H H max where n is unit turbine rotating speed. The curve is obtained from the turbine Hill Chart. 6) Rotating speed n: n n H / D. (8) The efficiency peak curve f 0, maximum efficiency curve f, maximum power curve f 2 and guide vane opening curve f 3 are shown in Figure 6 (a)-(d), respectively. 70 0.95 0.95 68 0.93 0.93 n 66 64 Hmax 0.9 0.89 Hmax 0.9 0.89 62 0.87 0.87 60 0.5 0.6 0.7 0.8 0.9 Q [m 3 /s] 0.85 0.85 0.5 0.9 0.6 0.5 0.6 0.7 0.8 0.9 Q [m 3 /s] (a) (b) f ( Q ) n f0(q ) H H max H max 0.9 24 24 0.8 22 20 22 20 0.7 8 8 Q 0.6 a 0 6 a 0 6 0.5 4 2 4 2 0.4 4 5 6 7 8 P [kw] 0 0 0.5 8 0.6 0.5 0.6 0.7 0.8 0.9 Q [m 3 /s] (c) Q f2 ( P ) (d) a0 f3( Q ) Figure 6 Hydraulic turbine characteristic curves 4

The calculation model is established in Matlab/Simulink to calculate the maximum efficiency during variation of water head or power order. The calculation diagram is shown in Figure 7. ηmax=f(q) Maximum Efficiency a0=f3(q) uide vane opening Water Head Turbine diameter Power order H(m) D(m) P(kW) P(kW) Unit Unit power flow Q=f2 - (P) n=f0(q) Unit rotating speed H(m) n D(m) n (r/min) f (Hz) Rotating speed Power freqency Figure 7 Simplified diagram for maximum efficiency calculation under variable speed operation The turbine efficiency under fixed rotating speed is also calculated and compared with the maximum efficiency under variable speed. The simplified calculation diagram for efficiency under fixed rotating speed is shown in Figure 8, in which the 2-dimensional interpolating method is used for calculation of unit flow and efficiency. Rated rotating speed Water Head Turbine diameter Power order n0 (r/min) H(m) n (r/min) D(m) Unit rotating speed calculation H(m) D (m) P(kW) P (kw) Unit rotating speed Unit power n (r/min) P (kw) Q (m 3 /s) Unit flow n (r/min) Q (m 3 /s) η Efficiency Figure 8 Simplified diagram for efficiency calculation under fixed speed operation 4. Benefits from variable speed operation Three calculation cases are studied in this section. In Case and Case 2, the efficiencies of variable speed operation and fixed speed operation are compared, in terms of water head variation and power order variation, respectively. Case 3 is performed to investigate the frequency variation range during the variable speed operation. Main parameters of the hydropower plant that used in the calculation cases are shown in Table I. Table I Main parameters of the hydropower plant Nominal power of turbine 306 MW Nominal power of generator 300 MW Pole pair number 28 enerator synchronous speed 07. r/min Efficiency of generator 0.98 Nominal diameter of turbine D 6 m Maximum water head H max 39.2 m Weighted average water head H av 9.9 m Optimized unit rotating speed 62 r/min 4. Case - Efficiency during water head variation The turbine efficiency vs. water head curves of both optimized variable speed operation and fixed speed operation are presented in Figure 9, including three scenarios with different power orders i.e. pu, 0.5 pu and 0.25 pu respectively. It can be observed that in each scenario, the variable speed operation will have higher efficiency than the counterpart of the fixed speed operation. The efficiency difference is getting larger when the water head is lower. At the nominal operation point (nominal 5

Frequency [Hz] Efficiency [%] Efficency [%] power and nominal water head), the efficiency difference is minimum, whereas there is still about.7% higher efficiency obtained. 0.9 0.8 0.7 0.6 pu (Variable speed) pu (Fixed speed) 0.5 0.5pu (Variable speed) 0.5pu (Fixed speed) 0.4 0.25pu (Variable speed) 0.25pu (Fixed speed) 0.3 60 70 80 90 00 0 20 Water Head [m] Figure 9 Case : The relationship of efficiency and water head under different power orders: variable speed and fixed speed 4.2 Case 2- Efficiency during power generation variation The turbine efficiency vs. power order curves of both optimized variable speed operation and fixed speed operation are presented in Figure 0, including three scenarios with different water heads, namely 40 m and 20 m respectively. It can be observed that compared with fixed speed operation, variable speed operation always has higher efficiency. Under certain water head, a maximum efficiency point can be obtained by variable speed operation. 0.95 0.9 0.85 0.8 40m Variable Speed 40m Fixed Speed 20m Variable Speed 20m Fixed Speed 0.75 60 80 200 220 240 260 280 300 320 340 Power [MW] Figure 0 Case 2: The relationship of efficiency and water head under different water heads: variable speed and fixed speed 4.3 Case 3- Impact of frequency variation on CB selection The power frequency of gerneator will impact the selection of the generator circuit breaker (CB) which connected between generator and converter transformer. enerally, CBs are designed and tested for normial power frequencies of 50 Hz or 60 Hz. For operation under norminal frequency, the magnitude of the current to be interrupted has to be reduced as the duration of the cycle would be longer than that at norminal frequency. According to [5], convential circuit breakers can operate over a frequency band but are subjected to a lower frequency limit of about 45 Hz on account of arc extincition times. It is necessary to investagte the frequency variation range of the generator and determine whether a commerialized CB can be used. In Case 3, the power frequency band of variable speed operation is calculated, under differenct power orders ( pu, 0.5 pu and 0.25 pu respectively). The calculation results are depcited in Figure. It is showed that in this example, a frequency band between 45 Hz- 60 Hz permits a large water head variation range. The frequency variation may not be critical issue for CB selection. Finially, because of the unit connection of VSC HVDC, the generator is not directly connected to the AC grid. Thus it should be evaluated that if a CB is really necessary in the system. 60 55 50 45 40 pu 35 0.5pu 0.25pu 30 80 90 00 0 20 30 40 Water Head [m] Figure Case 3: the power frequency vs. water head under different power orders 6

5. Conclusions The hydropower plant with VSC HVDC unit connection has an attractive prospect for hydropower integration and DC grid application. The major advantages of VSC HVDC unit connection come from variable speed operation of hydropower plant, as well as lower total initial investment and faster response etc. The maximum efficiency is calculated by using the Hill Chart of a typical Francis turbine. The calcualtion results show that the variable speed operation of of hydropower plant with VSC HVDC unit connection always has higher efficiency than that of fixed speed operation, under varaious of power order or water head. Based on the calculation, at least.7% higher efficiency can be obtained. The frequency variation band of generator is also analysed and it shows that the frequency variation may not be critical issue for CB selection. 6. Reference [] F. H. Shihang Duan, "Integrated Design of Speed Regulating Operation of Large-sized Hydropower Plant Conventional enerating Units and High Voltage DC Power Transmission," Yunnan Water Power, vol. 7, 200: pp. 4. [2] J. Kauferle, "Infeed from Power Station with enerators and Static Converters in Unit Connection," Brown Boveri Review, vol. 60, 973: pp. 205-2. [3] R. J. Kerkman et al., "An Inquiry into Adjustable Speed Operation of a Pumped Hydro Plant Part I - Machine Design and Performance," IEEE Transactions on Power Apparatus and Systems, vol. 99, 980: pp. 828-837. [4] R. J. Kerkman et al., "An Inquiry into Adjustable Speed Operation of a Pumped Hydro Plan Part II - System Analysis," IEEE Transactions on Power Apparatus and Systems, vol. 99, 980: pp. 838-844. [5] J. Arrillaga et al., "Direct Connection of enerators to HVDC Converters: Main Characteristics and Comparative Advantages," ELECTRA, vol. 49, 993: pp. 9-30. [6] D. Nhut-Quang, "Harmonic Domain Modelling of Direct Connected enerator and HVDC Convertor Units," Ph.D., University of Canterbury, 998. [7] J.. Campos et al., "uide for Preliminary Design and Specification of Hydro Stations with HVDC Unit Connected enerators," presented at the CIRE JW /4-09, HVDC Unit Connected enerators, 997. [8] M. Naidu and R. M. Mathur, "Evaluation of Unit Connected, Variable Speed, Hydropower Station for HVDC Power Transmission," Power Systems, IEEE Transactions on, vol. 4, 989: pp. 668-676. [9] L. Ingram, "A Practical Design for an Integrated HVDC Unit-Connected Hydro-Electric enerating Station," IEEE Transactions on Power Delivery, vol. 3, 998: pp. 65-62. [0] S. J. Macdonald et al., "Harmonic Measurements from a roup Connected enerator HVDC Converter Scheme," IEEE Transactions on Power Delivery, vol. 0, 995: pp. 937-943. [] S. Sankar, "Dynamic Simulation of AC/DC Systems with Reference to Convertor Control and Unit Connection," Ph. D., University of Canterbury, 99. [2] X. Pang, "Some Aspects of HVDC Unit-Connected eneration Scheme," Master of Science in Electrical Engineering, Faculty of raduate Studies, The University of Manitoba, 992. [3] Y. L. Wei Wang, Lihua Zhao, "Discussion on Application of High Voltage Direct Current Light Technique in Hydropower Exportation Delivery," Shanxi Electric Power, vol. 5, 2008: pp. 5. [4] S. Xu, C. uo, and W. Wang, "Optimum Load Regulation of the Variable Speed Hydrogenerator with AC Excitation," Large Electric Machine and Hydraulic Turbine, vol. 2, 995: pp. 0-3. [5] Joint Working roup /4.09. uide for Preliminary Design and Specification of Hydro Stations with HVDC Unit Connected enerators. IRE, August, 997: pp. 4. 7