Mounting instructions for Multifunctional trainer wood

Similar documents
Mounting instructions for Multifunctional trainer

Mounting instructions for Fitness bike

Mounting instructions for calisthenics

Mounting instructions for slide xena

Mounting instruction climbing equipment Tamino 1

Mounting instruction climbing equipment Tamino 2

Performance, Beauty & Long Life STAINLESS STEEL CARE & MAINTENANCE. Stainless Steel Performance. Stain less Steel

SlimLine Neo-Angle Base & Q-Wall-2

FitTech UP171F ELLIPTICAL (FOOTING) UP171I ELLIPTICAL (IN GROUND) UP171S ELLIPTICAL (SURFACE) Parts List

SlimLine Single Threshold Base & Q-Wall-5.1 BASE & BACKWALL INSTALLATION INSTRUCTIONS

Profiles for wooden and laminate floors Projoint T

FitTech UP166F CHEST PRESS (FOOTING) UP166I CHEST PREES (IN GROUND) UP166S CHEST PRESS (SURFACE)

Stainless Steel Maintenance Guide

Aqua Swing Tub Door & EX/RT Panel

FRANKFURT BIN.


INSTALLATION GUIDE DUOFUSE DECKING

Cornerview Shower Enclosure & Base

assembly and installation guide

Boulders Product: (Med), (Large)

CORNERVIEW SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Conergy SolarFamulus II

Movement joints and joint coverings Projoint DIL Cerfix Projoint DIL NT - ST

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

SURFACE PREPARATION INSTRUCTIONS: CONCRETE

Freestanding or Wall Mounted Taps

OPERATION & MAINTENANCE MANUAL

QUADLUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

TRUSSCORE PVC INTERLOCKING LINER PANEL

OPERATIONS & MAINTENANCE MANUAL

KENT SLIMLINE BOLLARD KSLB-75/1.5

Assembly and users manual. Pallet racking Alfa

Fallen Tree Bench. Product:

OPERATION & MAINTENANCE MANUAL

QUATRALUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

NOTES FOR THE PERFORMANCE BASED SPECIFICATION FOR TRAFFIC SIGNS

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

PRISMLUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

pro-t Data sheet Recommended use: Materials Substrates Features

Advantix bathroom drain. Instructions for Use from 01/2008. en_int

Safety Documents > Safety Manual > Scaffolds

SPECIFICATIONS: Architectural Aluminum Railings

OPERATION & MAINTENANCE MANUAL

Pittsburgh Corning Glass Block Shower System Mortar Installation Standard Fit Shower Instructions

10 EXTREME BASEMENT PANELS

Design Quality and Service

SECTION CAST-IN-PLACE CONCRETE

There are many surface contaminants that can interfere with coating adhesion. The following are the most common:

1993 SPECIFICATIONS CSJ SPECIAL SPECIFICATION ITEM 4110 CONCRETE ENCASED DUCT BANK

Underground Exhaust System

RESIDENTIAL FENCE STANDARDS

SECTION ALUMINUM HANDRAIL SYSTEMS

Huck Seiltechnik GmbH Aßlar/Berghausen Germany

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

Installation Instructions SE-Serie

San Antonio Water System Standard Specifications for Construction ITEM NO. 808 REINFORCED CONCRETE VAULTS

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

American Metal Specialties, Inc.

SKYLINE HOUSE CONDOMINIUM 3711 SOUTH GEORGE MASON DRIVE FALLS CHURCH, VIRGINIA

Prime Shower Enclosure & Base

MONOLITH. Basin System. installation + maintenance

ECCOFENCE KIT

Tactile Pad Installation Guide. All Surfaces.

Tender specification KLAUS Multiparking MultiBase 2072 outdoor installation EB MultiBase 2072 outdoor installation DB

PANELITE. Bonded Series Fabrication Guide

LIQUID PENETRANTS USER S MANUAL in accordance to specifications: EN 571, ASTME 1417, AMS 2644, MIL, ASME, DIN, UNI, BS, AFNOR, etc..

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

PHILIPP Power Box Installation Instruction

Installation Instructions

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SOLID DECKING PRODUCT GUIDE INSTALLATION TECHNICAL SPECIFICATIONS CARE & MAINTENANCE

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

QUATRA LUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Wall Hung WC Pan Model CWC_100 Series

blu stone freestanding basins Installation Guide

Installation Instructions Easy Climb 1 Art

SLIMLINE SHOWER BASE

One-Piece, Center Drain Shower Installations

MTI BATHS BOUTIQUE COLLECTION ENGINEERED SOLID STONE SHOWER BASES OWNER S MANUAL INSTALLATION GUIDE EFFECTIVE JANUARY 1, 2013

EVOCOAT HYBRID

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

One-Piece Barrier-Free Tub/Shower Installations

Porcher Solutions Wall Mount, Pedestal and Above Counter Lavatories

Prime Shower Enclosure, Base & Backwall

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

NOTICE XX/2017 SUPPLY AND ERECT PRE-CAST CONCRETE PALISADE FENCING WITHIN THE KOUGA MUNICIPAL AREA

Standard Parts. Ganter. Highlights Standard Parts in Hygienic Design

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

Installation instructions. LORO-ATTIKASTAR siphonic drains

STANDARD PRACTICE INSTRUCTION

Prime Shower Enclosure & Base Kit

Playground Review and Maintenance Process

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Glenlake Modular Railing System

AQUA UNO TUB DOOR INSTALLATION INSTRUCTIONS

Installation Data PSL/R, PSML/R, PSTL/R, PSTML/R, PSL/R, PSML/R, PSTL/R, PSTML/R

FIVE STAR PRODUCTS, INC. (800)

Assembly instructions Fortuna Play Course Art part

4 EXTREME FOUNDATION PANELS

Double Tidy Rail. Assembly Instructions- Please keep for future reference. Important - Please read these instructions fully before starting assembly

Transcription:

Diagram 1: Overall view of the fitness equipment stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid Tel. +49 (0) 2689 92790-0 Alle Rechte und Produktmodifikationen vorbehalten State: 08.02.2017 p. 1

Beton Concrete Erde Ground 1. Select the fitness equipment location in consideration of the required safety area (see diagramm 4: 0 mm). 400 150 3630 4030 60 Kies Gravel 2. Carry out excavation work for the foundation anchor as shown in Diagram 2. After excavation, compress the foundation floor. Note: The fitness equipment is built in on the ground level. Pay attention to items marked ground level of the fitness equipment! 3. Set up the three concrete foundations acc. to the dimensions indicated (Lx- BxH x x 400mm) with central, horizontal reinforcement (BST 500 S) in the quality class C 20/25. Reinforcement plan: Concrete foundation with reinforcement Main foundation: BSt 500S Ever 4 stirrups Ø 8 mm lengthwise and cross Concrete cover h = 3 cm Concrete quality class B25 4654 4254 4. Select the postition of the fitness information sign. Attention: Because of the risk of injury, the instruction sheet has to be arranged outside of the minimum zone of the Multi-functional trainer wood. 1925 1927 3561 30 400 3337 4237 4030 5037 Diagram 2: Foundation plan with dimension details Multi-functional trainer wood stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid Tel. +49 (0) 2689 92790-0 Alle Rechte und Produktmodifikationen vorbehalten State: 08.02.2017 p. 2

Head part 5. Carry out excavation work for the instruction sign for the two foundations as shown in Diagram 5. After excavation, compress the foundation floor. 6. Set up the concrete foundations acc. to the dimensions indicated (LxBxH 300 x 300 x 300 mm) in the quality class C 20/25. 7. After the setting period of 10-14 days - depending on weather conditions and foundation size - clean the surface of the foundation, and start with the mounting of the fitness equipment. Composite lumber 8. Connect the three composite lumbers at the provided ends with the head part with the screws included in the delivery. Do a rough aligning at the foundation Note: Do not screw the base plates onto the foundations yet! Connection of the fitness element 9. Connect the fitness elements at the intended locations acc. to the Diagram 1 and 3 with the screw included in the delivery. 10. Adjust the sports equipment and screw the base plate of the fitness equipment onto the foundation anchor with the included heavy-duty dowels. Diagram 3: Detailed elements stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid Tel. +49 (0) 2689 92790-0 Alle Rechte und Produktmodifikationen vorbehalten State: 08.02.2017 p. 3

Extent of the minimum zone = safety area 11. Place the instruction sheet as well onto the foundation and anchor with the included heavy-duty dowels. NOTE: We suggest to align the instruction sheet with the result that the instructions are visible during the use of the fitness equipment. 12. Fill up the existing gaps between the foundation and foundation hole with excavated soil and compact and built am even ground level. 0 13. Seal the foundation with the safety cover required for the height of fall indicated. Critical drop height: about 2650 mm Recommended surface material: synth. fall protection. 14. Do not allow to use the equipment before the installation has been finished. Attention: If the fitness equipment has been incompletely installed or partly dismantled when carrying out maintenance and repair work, this may lead to particular risks of injury for the user. For this reason, make clearly visible that the equipment shall not be used in such cases. Diagram 4: Top view Multi-functional trainer wood stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid Tel. +49 (0) 2689 92790-0 Alle Rechte und Produktmodifikationen vorbehalten State: 08.02.2017 p. 4

Beton Concrete Erde Ground Füllmaterial Filling NOTE: Fitness equipment, which contain components made of stainless steel should not come with normal steel parts in contact. Those steel parts may rub off and leave small steel particles in combination with moisture brown rust stains.if such corrosion occur on stainless steel parts, they are fine with an abrasive (240 grit) to remove. Please take care when transporting and setting up the fact that the components are made of stainless steel with no normal steel parts in contact. 300 300 400 300 Diagram 5: Foundation plan of the instruction sheet stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid Tel. +49 (0) 2689 92790-0 Alle Rechte und Produktmodifikationen vorbehalten State: 08.02.2017 p. 5

In order to preserve a good visual appearance of your stilum playground equipment over a long period one should take care of maintenance of the stainless surface even despite of their corrosion resistance. Especially areas, which can not be reached by rainfall should be frequently cleaned from dirt and deposits due to air pollution and dirt caused by the atmosphere. Light soiling can easily be romoved by using a high pressure cleaner. For persistent deposits use a clean cloth moistened with a special liquid cleaner (e.g. on phosphoric acid) and rinse off with clear water after a short application time. During cleaning with mild abrasive components, only wipe over stainless steel surface in polishing direction. For heavily soiled surfaces, polishes can be used (e.g. for cleaning chrome on cars) or for greasy and oily dirt alcoholic cleaning agents and solvents (e.g. ethyl alcohol, isopropyl alcohol or acetone). However, it should be noted that the dissolved soiling is not spread over the surface again. Do not use any chlorid or hydrochloric containing cleaning products nor scouring powder, bleaching - or silver polish cleaner. Cleaning intervals depend on type and degree of soiling as well as on demands made on optical characteristics. Therefore cleaning is advisable at intervals of six to twelve months whereby in the case of strong soiling it is appropriate to clean the playground equipment at intervals of 3 to six months. General Information DIN 16630:2015-06_4.1: DIN EN1176 specifies that fitness equipment should not be installed in the immediate vicinity of children s playground equipment. In cases where they are erected in playgrounds or similar establishments near children s playground equipment, they must be separated by adequate distance, fencing or other structural means from the general play zone. Movement area DIN 16630:2015-06_4.3.14.4 The free space allowed as movement area must be a minimum of 2.2m. The movement area must be clear of fences, and observers should not wait in this space. The space should be free of all objects that the user could fall on and be injured. E.g. injuries could be caused by posts that are not flush with adjacent parts or by protruding footings. In cases where the equipment has a forced movement, the free area must be extended about 0.5m. Where fitness units are installed on or adjacent to a wall which is at least as high as the exercise space, the movement area may be reduced. Movement areas of adjacent equipment may overlap except for equipment with forced movement. stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid Tel. +49 (0) 2689 92790-0 Alle Rechte und Produktmodifikationen vorbehalten State: 08.02.2017 p. 6