ADVANCED SOFTENING MATERIAL FOR PROBLEM WATER

Similar documents
ADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium

DW Module 22 Inorganic Removal Basics Answer Key

Water Treatment & Purification Chemicals

Filtration & Pretreatment Basics

Watch Water. ANSI/NSF 61 Certified From. February 2014

TREATMENT OF WATER. A.Sateesh Chemist State Level Laboratory

ISR (IRON SPECIFIC RESIN)

Water supplied by Marafiq does not meet the process requirements.

Valve Nest Filter with Time Clock Control Installation and Operation Manual

KDF Process Media. Improve the performance and economy of your water purification system.

C-100E Strong Acid Cation Exchange Resin (For use in water softening applications)

SECTION 5 E-Treat Water Conditioning Systems

SALT EFFICIENCY FOR SOFTENER REGENERATIONS. Presented. ALBERTA Public Works, Supply and Services Management Division. Ft. Saskatchewan, Alberta

Household Water Treatment

IRON, MANGANESE AND HYDROGEN SULFIDE IN PRIVATE WATER SUPPLIES

How to Choose a Water Softener. Brought to you by

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc.

POWER OF PURITY ecosoft.com ABOUT THE COMPANY

Solving Water Problems

Treatment of all source water influent & effluent for user application, be it commercial, industrial, domestic, to defined & required standards.

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION

On-Site Sodium Hypochlorite Generation Equipment

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business

Water Treatment Solutions A - Z

WEFTEC.06. Lake Okeechobee, Actiflo, peroxone, surface water, Cyanobacteria

MAINTAINING DRIP IRRIGATION SYSTEMS

Understanding Reverse Osmosis Mark Rowzee Mark Rowzee

Lecture 1: Introduction

Water Treatment. Water Conditioning Parts - Aquatrol Pressure Tanks

Reverse-osmosis membranes were

SST-60 Salt Saving Technology Softening Resin

3/25/2015. MARCH 24, 2015 Chad T. Olsen, P.E., BCEE. WRWA 27 th ANNUAL TECHNICAL CONFERENCE. City of Chilton, Wisconsin. Chilton.

Water Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water

from the water treatment specialists

WATER CONDITIONING & ENVIRONMENTAL PROTECTION

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06

Specific Gravity 2.69 Minimum Bed Depth 24 Inches (600mm) Effective Size Freeboard 40% minimum Uniformity Coefficient 1.4 Service Flow Rate

C-100H Strong Acid Cation Exchange Resin in Hydrogen Form (For use in water demineralization)

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

SIMPLEX R-EVOLUTION SMC

Demineralization (RO, NF, UF, MF, ED, IE)

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

Membrane Technology: From Manufacture to. May Production

Aqua Pristine Global Technologies, an ISO 9001:2008 & CE certified company is a leading supplier of world class Domestic RO, Industrial RO Plant,

A-300, A-300E Strong Base Type II Anion Exchange Resin

ADVANTAGES MAIN FEATURES BENEFITS DUPLEX R-EVOLUTION 330/DCA

Exeterline. R.E. Prescott Company Water Treatment Catalog. Enter a World of Cleaner Water.

Sustainability in commercial laundering processes. Module 1 Usage of water. Chapter 3b. Water softening

Hybrid RO & Softening Birjand Water Treatment Plant

The Iron Curtain Filtration System

the faculty for factory program (FFF), Jordan

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System

Water and Wastewater Engineering Dr. Ligy Philip Department of Civil Engineering Indian Institute of Technology, Madras

PERFORMANCE DATA SHEET Water Conditioning Systems

Training Fees 3300 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch

DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50%

Technical Data. Typical Chemical & Physical Characteristics

Produced Water Treatment Systems

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

PERFORMANCE DATA SHEET Water Softening Systems

WATER RECYCLING SOLUTIONS

City of Woodbury. Red Bank Water Treatment Plant - Treatment Alternatives Analysis November 2016

» cartridges for household filter systems in combination with activated carbon.

MANUAL DUAL MEDIA FILTER (MILD STEEL)

Advanced water purifier system operation manual and setup guide

Petro-Canada Re-Uses Treated Edmonton Waste Water. Coking.com Safety Seminar Calgary September 2008

Fresh water may come from either a surface or ground source and typically contains less than 5 000ppm TDS.

WATER FILTRATION EQUIPMENT LWF Series Commercial Water Filters

Cover. Pressure Filters

Cover. Pressure Filters

1. Inspection and monitoring... 3

Collection and Treatment of Flowback and Produced Waters from Hydraulic Fracturing. Edwin Pinero Veolia Water North America

Treatment Technologies

Sources of Iron and Manganese in Drinking Water. Indications of Iron and Manganese

Concentration mg/l TDS mg/l 10, ,000 Recovery 75% Waste TDS mg/l 44,000 COD mg/l 3,500 0 BOD NTU 1,250 0 Power Used kwh/m3 2.

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

LEWATIT S 7468 PRODUCT INFORMATION

TKA MaxiTower plus. Pure water State-of-the-art Technology. WATER PURIFICATION SYSTEMS

Water Quality and Filtration. Amphibian Ark

Water softening and scale prevention

Water for Instrument Processing

CHAPTER 2 COLD WATER SUPPLY. Prof. Dr. Uğur Atikol

Making feed water for you! Advantage. Protecting any Water Treatment System against. Scaling. a Water Company WAT C H WAT E R

PERFORMANCE DATA SHEET Water Conditioning Systems

REQUEST FOR PROPOSALS DESAL ANTISCALANT/CLEAN-IN-PLACE CHEMICALS BID NO: ADDENDUM 1

Part 5: Environmental Engineering

Morton Treatment Plant Process Performance Evaluations: The Removal of Microbial Nutrients

WATER TREATMENT TRAINING. Eng. Festus Ng eno

Creating SDI Solutions WATER TECHNOLOGIES

WATER TREATMENT COMPONENTS. Ion exchange resins and filtering media

WATER TREATMENT COMPONENTS. Ion exchange resins and filtering media

WATER TREATMENT COMPONENTS. Ion exchange resins and filtering media

PERFORMANCE DATA SHEET Powerline Water Conditioning Systems

Feed Water Reduction in Industrial Water Purification Systems

Treatment Processes for Potable Water

Modular Education Program Course Catalog Certificates, Badges, and Learning Activity descriptions.

A real sense of comfort & performance.

Common Well Problems. Common Well Problems. Well Forensics. Difficult Well Problems May Require Well Forensics 12/11/2017

Product. LIFE IS BETTER with

CTB3365x Introduction to Water Treatment

Transcription:

ADVANCED SOFTENING MATERIAL FOR PROBLEM WATER SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium Used by water treatment companies globally since 1998 EUROPE

WHAT ECOMIX IS ECOMIX is a scientifically grounded technology, confirmed by 6 patents and service world-wide since 1998. ECOMIX works effectively in well water and municipal water within the allowable concentrations of iron and manganese, hardness and natural organic matter. ECOMIX consists of five ingredients, including two patented materials. 82 materials researched 1998 developing and patenting Ecomix 6 patents Ecomix purifies water from: hardness iron manganese natural organic matter ammonium Certified in compliance with the NSF/ANSI 44/61/372 standards

HOW ECOMIX WORKS Delivered and loaded as homogeneous media Top basket Stratifies into five layers after regenereation Regenerates with softener plain salt * Inert layer enhances backwash FerroSorb unique reduces iron and manganese compounds HumiSorb unique reduces natural organic matter and organic iron Do not use resin cleaner salt or chemicals Cation exchange resin softens water * Potassim chloride at a higher dosage can also be used Gravel ensures uniform flow across the vessel Bottom basket 3

REDUCING IRON AND MANGANESE FerroSorb is a proprietary sorption material for iron and manganese reduction Dissected FerroSorb bead Mechanism of iron and manganese reduction ADSORPTION OXIDATION ACTIVE LAYER FORMATION AUTOCATALYTIC OXIDATION This chain works to reduce iron in the dissolved ferrous form (clear water iron). The surface layer of FerroSorb contains active sites for reduction of manganese. For best resuts pre-treat with a sediment filter only. Aeration and oxidative pre-treatment should be avoided. Treat iron bacteria before installing ECOMIX. 4

REDUCING ORGANIC MATTER HumiSorb is a proprietary sorption material for reduction of natural organic matter (reduces color and chemical oxygen demand) Fresh HumiSorb beads HumiSorb beads after service Organic compounds and organic iron are reduced due to hydrophobic and electrostatic interactions with HumiSorb. Check the level of chemical oxygen demand before using ECOMIX when natural organic matter reduction is desired. ECOMIX is intended for the treatment of well water and chlorinated municipal water from tannins. ECOMIX is not designed for the treatment of surface water (lakes, ponds, rivers, swamps etc). Water from a shallow well located close to the surface water should be checked for organic matter concentration and microbiological safeness. Microbiologically unsafe water cannot be treated by ECOMIX. 5

ECOMIX REGENERATION ECOMIX is regenerated with the same steps as normal softeners: backwash, brine, rinse. Calcium and magnesium ions are displaced from the cation exchange resin matrix with sodium ions. Iron and manganese compounds are removed by surface friction of FerroSorb beads in fluidized bed during backwash. HumiSorb exhibits a reversible mechanism of sorption of organic molecules, and is regenerated with chloride ions. 6

ECOMIX EFFICIENCY AND LIMITATIONS Raw water quality requirements and efficiency of purification typec 5 in 1 4 in 1 type Influent limitations Type С Max. efficiency, % Type А Hardness 750 ppm CaCO 3 97 Iron 15 ppm 98 Manganese 3 ppm 98 TOC* 17 ppm C 80 50 Ammonium 4 ppm 90 *TOC (total organic carbon) is used as a measure of natural organic matter OPERATING CONDITIONS: ph 5 9 No limits on influent hydrogen sulfide or anion content Active chlorine 1 ppm TDS 4000 ppm 7

ECOMIX TECHNICAL SPECIFICATIONS When designing ECOMIX units, refer to the following figures: Parameter Value Service flow rate 20-25 m/h Backwash flow rate 10-15 m/h!!! Brine (slow rinse) flow rate 3-5 m/h Minimum bed depth 500 mm Recommended bed depth 800 mm Freeboard 40% or more Salt consumption 100 g/l Brine concentration 8-10% Water consumption per regeneration under 10 L/L Rust removal, resin cleaner salt, and chemicals will affect ECOMIX performance. If using potassium chloride increase salt dosage to 145 g/l. ECOMIX does not affect ph. 8

COMMONLY USED VESSELS BAG HALF BAG Size of vessel 1035 1054 1252 1354 1465 1665 2162 Ecomix volume, L 25 37 50 62 75 100 150 Service flow rate, m 3 /h 1.3 1.3 1.8 2.2 2.5 3.3 5.5 System capacity, kg, CaCO 3 0,88 1,32 1,7 2,2 2,6 3,5 5,25 Salt per regeneration, kg 2.5 3.8 5.0 6.2 7.5 10.0 15.0 Backwash flow rate, m 3 /h!!! 0.6 0.6 0.9 1.1 1.2 1.6 2.7 *ECOMIX is supplied in two size types: Bag - 0.88 cu. ft. (25L) Half bag - 0.42 cu. ft. (12L)!!! Pay attention to the backwash flow rate and choose the right drain line flow control (DLFC). Visit ecosoft.com/ecomix.us to use the ECOMIX calculator. 9

VOLUME CAPACITY OF ECOMIX UNIT Volume capacity can be calculated using just influent hardness and ECOMIX IX capacity. ECOMIX C - 30 g CaCO 3 / L ECOMIX A - 35 g CaCO 3 / L Volume Capacity, m 3 = Ecomix volume, L x IX Capacity, g CaCO 3 Influent Hardness, ppm CaCO 3 Average service life is 5 years No need to compensate raw water hardness for iron and manganese concentration when calculating volume capacity. 10

ECOMIX INSTALLATION SCHEMATIC Treated water Feed pressure 2.8-4.0 bar recommended Input water hardness in control valve settings Raw water Regenerate after installation Drain line tube diameter equal to tube drain connection and should not exceed 2,5 m. If longer, increase drain line tube diameter Sediment pre-filter PP cartridge filter for clear water *For water with high turbidity and iron content (over 10 ppm) application of filter with Filter Ag media is recommended 11

ECOMIX IN RESIDENTIAL ENVIRONMENT STANDARD SOLUTIONS MULTISTAGE SOLUTIONS 1 2 3 1 2 3 1 Sediment filter for sand, rust and silt removal 2 ECOMIX system for hardness, iron, manganese, natural organic matter & ammonium removal 3 Сentaur carbon system for 1 2 3 hydrogen sulfide removal 1 2 2 3 12

ECOMIX IN COMMERCIAL AND INDUSTRIAL APPLICATIONS ECOMIX is used to treat raw water supplied to reverse osmosis systems, to soften and reduce iron from boiler feed water, to purify domestic water in hotels, apartment buildings and business centers. 13

ECOMIX PRODUCTION ECOMIX is manufactured in Germany The manufacturing process includes surface activation of FerroSorb and HumiSorb. Digital control of ingredient mixing ensures consistent quality of finished product across batches. ECOMIX is certified in EU for compliance with LFGB requirements for foodcontacting materials by TÜV SÜD. ECOMIX is certified in compliance with NSF/ANSI standards: - NSF/ANSI 61 Drinking Water System Components Health Effects - NSF/ANSI 44 Residential Cation Exchange Water Softeners - NSF/ANSI 372 Drinking Water System Components Lead Content Scheme 14

ECOMIX SUPREMACY 100 % success rate up to10 years service life Most reliable technology for removal of iron and manganese Highest permissible concentration of iron and manganese Smallest regeneration salt requirement Consistent quality of purified water throughout the material s service life ECOMIX is not only a unique water treatment technology. It has been a firm platform for the corporate success of numerous companies around the globe. 15

SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium ECOMIX is certified in compliance with NSF/ANSI standards ECOMIX is certified in EU by TÜV SÜD meets the requirements LFGB ResAP(2004)3 EU Guideline 2002/72/EG Ecosoft Water Systems GmbH www.ecosoft.com www.ecomix.us Ecosoft 02-02-2017