Diagnosis Sanger. Interpreting and Troubleshooting Chromatograms. Volume 1: Help! No Data! GENEWIZ Technical Support

Similar documents
Sanger Sequencing: Troubleshooting Guide

ZR-96 Genomic DNA Clean & Concentrator -5 Catalog Nos. D4066 & D4067

Genomic DNA Clean & Concentrator -25 Catalog Nos. D4064 & D4065

Guide to Sanger Sequencing at RAMAC

Cold Fusion Cloning Kit. Cat. #s MC100A-1, MC101A-1. User Manual

Presto Mini Plasmid Kit

GenepHlow Gel Extraction Kit

2. Pyrosequencing Assay Design

GenBuilder TM Cloning Kit User Manual

GenBuilder TM Plus Cloning Kit User Manual

GenBuilder TM Plus Cloning Kit User Manual

Lecture Four. Molecular Approaches I: Nucleic Acids

Hetero-Stagger PCR Cloning Kit

Polymerase Chain Reaction (PCR)

Ligation Independent Cloning (LIC) Procedure

Genomic DNA Clean & Concentrator -10 Catalog Nos. D4010 & D4011

EZ-10 SPIN COLUMN HANDBOOK

Presto 96 Well PCR Cleanup Kit

Gene-Spin DNA Purification Kit - V3

Introduction. Kit components. 50 Preps GF-PC-050. Product Catalog No. 200 Preps GF-PC Preps GF-PC Preps SAMPLE

GENOMICS RESEARCH LABORATORY Sample Submission Requirements

Sanger sequencing troubleshooting guide. GATC Biotech AG

FAQs: PCR Polymerases from Takara Bio

SpeedSTAR HS DNA Polymerase

Presto Soil DNA Extraction Kit

PlantDirect TM Multiplex PCR System

Plus DNA Clean/Extraction Kit

7.1 Techniques for Producing and Analyzing DNA. SBI4U Ms. Ho-Lau

Updated August well High-multiplexing Tagmentation and Amplification Robyn Tanny August Company Kit Catalog Number.

Plasmid Midiprep Purification Kit

PureSpin DNA Clean Up Kit

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Gene Jockeying: Tricks of the Trade so that your Ligations work Every Time! Bevin Engelward

Product # Specifications. Kit Specifications Column Binding Capacity 25 µg

3 Designing Primers for Site-Directed Mutagenesis

1. COMPONENTS. PyroStart Fast PCR Master Mix (2X) (#K0211 for 250 reactions of 20µl) 2. STORAGE 3. DESCRIPTION

7 Synthesizing the ykkcd Mutant Toxin Sensor RNA in vitro

Genetics and Genomics in Medicine Chapter 3. Questions & Answers

Zymo-Spin Technology. The microcentrifuge column that revolutionized nucleic acid clean-up

Guide-it Indel Identification Kit User Manual

Bead Type (NaI) Gel Extraction Kits

Guide-it sgrna In Vitro Transcription and Screening Systems User Manual

YeaStar Genomic DNA Kit Catalog No. D2002

Hurricane Miniprep Kit PROTOCOL

Geneaid Maxi Plasmid Kit & Geneaid Maxi Plasmid Kit (Endotoxin Free)

Table of Contents. I. Description...2. Components...2. Storage...2. Features...2. V. General Composition of PCR Reaction Mixture...

Zymoclean Large Fragment DNA Recovery Kit Catalog Nos. D4045 & D4046

YG1 Control. YG1 PstI XbaI. YG5 PstI XbaI Water Buffer DNA Enzyme1 Enzyme2

Aurum Plasmid Mini Kit. Instruction Manual. Bio-Rad Laboratories, Inc Alfred Nobel Dr. Hercules, CA USA (510)

Large DNA Fragments Extraction Kit

TIANgel Mini DNA Purification Kit

Polymerase Chain Reaction

UltraClean Midi Plasmid Prep Kit

MgCl 2 (25 mm) 1.6 ml 1.6 ml 1.6 ml 1.6 ml

DNA Technology. Asilomar Singer, Zinder, Brenner, Berg

TaKaRa MiniBEST Plasmid Purification Kit Ver.4.0

pgm-t Cloning Kit Cat. # : GVT202 Size : 20 Reactions Store at -20

Description...1 Components...1 Storage... 1 Technical Information...1 Protocol...2 Examples using the kit...4 Troubleshooting...

Bio-Rad Laboratories, Inc Alfred Nobel Dr. Hercules, CA USA (510) Rev C

TB Green Premix Ex Taq II (Tli RNaseH Plus)

Specifications. Kit Specifications. Alcohol Precipitation: Up to 100 ml Column Purification: Up to 5 ml Column Binding Capacity 25 µg

KAPA HiFi HotStart ReadyMix PCR Kit

Mag-Bind Ultra-Pure Plasmid DNA 96 Kit. M x 96 preps M x 96 preps

Lab Book igem Stockholm Lysostaphin. Week 8

Sanger Sequencing Portfolio

I-Blue Midi Plasmid Kit. I-Blue Midi Plasmid Kit. (Endotoxin Free) IBI SCIENTIFIC. Instruction Manual Ver For Research Use Only.

PLNT2530 (2018) Unit 6b Sequence Libraries

BIO 121 LAB 10 - DNA I

TB Green Premix Ex Taq (Tli RNaseH Plus)

Presto Stool DNA Extraction Kit

Synthetic Biology for

Amplicon Library Preparation Method Manual. GS FLX Titanium Series October 2009

Roche Molecular Biochemicals Technical Note No. LC 9/2000

GenepHlow Gel/PCR Kit

MB542 HiPurA TM Soil DNA Purification Kit

PCR OPTIMIZATION AND TROUBLESHOOTING

Supplementary Methods pcfd5 cloning protocol

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085

ml recombinant E. coli cultures (at a density of A 600 units per ml)

Guide-it sgrna In Vitro Transcription and Screening Systems User Manual

Comparison of ExoSAP-IT and ExoSAP-IT Express reagents to alternative PCR cleanup methods

TIANpure Mini Plasmid Kit

PureSpin. Gel DNA Purification Kit. Micro Columns INSTRUCTION MANUAL. KIT COMPONENTS For Research Use Only. PureSpin.

Molecular Genetics Techniques. BIT 220 Chapter 20

Nextera DNA Sample Prep Kit (Roche FLX-compatible)

TIANquick Mini Purification Kit

Amplicon Sequencing Template Preparation

ExactORF cdna Clones. Application Guide. Table of Contents


DNA miniprep by Alkaline Lysis (activity)

Biol/Chem 475 Spring 2007

Presto Food DNA Extraction Kit

Lab Book igem Stockholm Lysostaphin. Week 9

Soil DNA Extraction Kit

Amplification Products for PCR and RT-PCR

BENG 183 Trey Ideker (the details )

Fast and reliable purification of up to 100 µg of transfection-grade plasmid DNA using a spin-column.

Transcription:

Diagnosis Sanger Interpreting and Troubleshooting Chromatograms GENEWIZ Technical Support DNAseq@genewiz.com

Troubleshooting This troubleshooting guide is based on common issues seen from samples within GENEWIZ laboratories in the United States. There are several possible causes for a no priming result. It does not necessarily indicate that no primer was added to the reaction or that the primer does not bind to the template. The list of potential causes is not exhaustive, but represents the most common issues. For more assistance, please contact Technical Support at 877-436-3949 ext. 2 or dnaseq@genewiz.com. The following sections are broken out by DNA template types and discusses many causes for no priming failures. Introduction... 3 Common Causes for Many Template Types... 5.Plasmids... 7 Purified PCR Products... 8.Unpurified PCR Products... 9 Bacterial Colonies... 10 Glycerol Stocks... 11 Phage... 12 BAC DNA... 13 2

Introduction One of the hardest problems to troubleshoot is a lack of data. This is called no priming in the GENEWIZ failure cause guide, but it can also be interpreted to mean a failed sequencing reaction. A no priming failure cause indicates that the primer annealed to the template with poor efficiency and/or extension from the bound primer was inhibited. As a result, little or no sequencing product was generated. To identify a no priming reaction, the chromatogram should be opened and examined. Typically, no priming reactions have an average signal intensity of less than 100. Often the signal will be garbled, with no clear or uniform peaks. Very low intensity traces can be pulled up by the analysis program through normalization/rescaling, making it difficult to distinguish true signal from background noise (which typically has an intensity of 40 to 50). Due to the lack of a sequencing product, base calling in these chromatograms is unreliable and mostly inaccurate. GENEWIZ technical support scientists recommend that any data with signal intensity under 100 should not be used for further downstream analysis. Please note that the distinction between poor quality and no priming results is sometimes arbitrary; however, the former may provide some useful data whereas the latter usually does not. Figure 1. Illustration of a no priming reaction vs. a successful reaction. NO PRIMING GOOD RESULT Overlapping, poorly defined peaks with an average signal intensity* below 100 Well-defined peaks with low background for at least 500 bp *The average signal intensity of each base (A, T, G, C) is displayed at the bottom of the online trace viewer. 3

Example Chromatograms Figure 2. No priming chromatogram examples (A) Notice the signal intensities for each nucleotide (A, T, G, C) are below 100. The chromatogram peaks are unpatterned and appear garbled; a good quality sequence will have regular, patterned chromatogram peaks with well-defined peaks and troughs. Another indication of a poor-quality reaction is the appearance of many N residues distributed through the.txt file sequence. A high occurrence of N residues in the middle portion of the.txt file sequence indicates a problem with the sequencing reaction and requires careful examination of the chromatogram file. (B) Occasionally, the.txt file sequence will actually terminate after only a handful of N residues. This means the algorithm did not detect sufficient usable sequence in the trace file and automatically stopped reading the file. A. B. 4

Common causes for many template types: no priming failures DNA template concentration is too low or high. Check that the DNA concentration is in the correct range. Review our Sample Submission Guidelines. Primer concentration is too low or high. Check that the primer concentration is in the correct range (if not using a GENEWIZ universal primer). Premix reaction: Add 5 μl of 5 pmol/μl primer to your DNA samples Pre-Defined reaction: Send your primer separately at 5 pmol/μl Note: 5 pmol/μl = 5 μm = (1.65 ng/μl) (# of bases in oligo) Primer not added. Make sure that the primer has been added if sending a premix order and not using a GENEWIZ universal primer. Poor-quality DNA template, including contamination with: Guanidine or other chaotropic salts Phenol or chloroform EDTA Ethanol or isopropanol Check the absorbance ratios on a spectrophotometer. Aim for values greater than 1.8. o A260/280 < 1.8 may indicate protein contamintion. o A260/230 < 1.8 may indicate contamination with organic chemicals (e.g. guanidine, phenol or EDTA). This ratio is critical for successful We recommend eluting your DNA in molecular biology grade water and avoiding buffers containing EDTA, such as TE, which can inhibit the sequencing reaction. Tris-Cl, sometimes called EB buffer, is safe for For preps or cleanups, be sure to dry samples well prior to elution to avoid reagent carryover. Check the integrity of your DNA on a gel. Sheared or fragmented DNA can lead to poor sequencing results. For PCR products, run your product on an agarose gel to confirm that it produces a single band of the correct size. For additional tips on how to optimize PCR for sequencing, see our Sanger Tips & Tricks series. 5

Common causes for many template types: no priming failures (cont d) Primer binding site is not present. Check that the primer binding site is present. If using a GENEWIZ universal primer, check the sequence to make sure it matches your vector. Perform a diagnostic restriction digest to verify plasmid identity and the presence of an insert. Primer binding site not present. Primer Tm is too low. Use oligo analysis software to verify the following: Melting temperature (Tm) of the primer is 50-60ºC. Primer does not have significant self-complementary, leading to self-dimersor hairpins. o Problems arise at dimer/hairpin conformations more negative than -10 kcal/mol. Primer forms a dimer or hairpin. Free online tools include OligoAnalyzer (IDT) and OligoCalc (Kibbe 2007). Template forms secondary structure near the primer binding site. Use GENEWIZ s Alternative Protocol, designed for difficult templates. This protocol helps to denature secondary structure that impedes polymerization. If you know your template is prone to forming secondary structure, simply choose Difficult Template, Hairpin, RNAi, or GC-rich from the Special Request column when placing your order. All options refer to the Alternative Protocol. Please note there is an additional charge for this service. You can repeat failed reactions with the Alternative Protocol at half price by choosing 1/2 Price with Alt. Protocol from the Repeat column dropdown menu on the Order Results page. Try sequencing with a primer that is further upstream or downstream of the current primer location, or try sequencing from the other direction. Sometimes changing the primer location can help sequence through a difficult region. 6

Problems for purified plasmids: no priming failures Plasmid is greater than 20 kb. Larger plasmids can be difficult to sequence efficiently. For >20 kb plasmids, ensure you submit highly pure samples at 100-150 ng/μl. For plasmids over 50 kb, our BAC protocol may yield better results. Alternatively, use PCR to amplify the region of interest and submit PCR products for 7

Specific problems for Purified PCR: no priming failures PCR primer is not compatible with Occasionally, a primer used in PCR amplification will not be compatible to use as a sequencing primer. When using a PCR primer for sequencing, please note that the cycling conditions of sequencing may differ from that of your PCR. For example, our sequencing protocol uses an annealing temperature of 50 C. Thus, a primer that works well in your PCR may not be appropriate for Designing a nested primer slightly downstream of the original primer binding sequence can yield better sequencing results. PCR reaction loading dye not compatible with sequencing reaction. Most PCR loading dyes are compatible with Sanger However, if the sequencing reaction fails and there is a loading dye in the reaction, a good troubleshooting step to take is to test the reaction using a different system without loading dye. Failure to inactivate enzymatic PCR clean-up reaction post-clean-up. If the PCR reaction is purified using an enzymatic purification protocol, the enzyme will need to be inactivated prior to use in the sequencing reaction. Make sure that the heat inactivation step recommended by the protocol/kit manufacturer is followed prior to setting up the sequencing reaction. 8

Specific problems for unpurified PCR products: no priming failures Low-copy plasmid used. These plasmids may not provide sufficient input DNA for efficient amplification. Use a vector with a high-copy origin of replication. Prep the DNA and submit purified plasmids. Use PCR to amplify the region of interest and submit PCR products for PCR reaction loading dye not compatible with sequencing reaction. Most PCR loading dyes are compatible with Sanger sequencing, particularly those which are included in commercial PCR master mixes. However, if the sequencing reaction fails and there is a loading dye in the reaction, a good troubleshooting step to take is to test the reaction using a different system without loading dye. Loading dyes containing EDTA can potentially inhibit the sequencing reaction. 9

Specific problems for bacterial colonies: no priming failures Possible Low-copy plasmid used. These plasmids may not provide sufficient input DNA for efficient amplification. Use a vector with a high-copy origin of replication. Prep the DNA and submit purified plasmids. Use PCR to amplify the region of interest and submit PCR products for EndA+ strain used. Certain strains of E. coli (e.g. BL21, Stbl3) contain a non-specific endonuclease in the periplasmic space that can cleave plasmid DNA when cells are lysed, leading to inefficient amplification. Use a strain with the enda mutation (e.g. DH5α, TOP10). Prep the DNA and submit purified plasmids. Use PCR to amplify the region of interest and submit PCR products for Plasmid is greater than 20 kb. Rolling circle amplification is less efficient on larger templates. Use PCR to amplify the region of interest and submit PCR products for Cells do not contain a plasmid. Only small circular templates (i.e. plasmids) can be used successfully with rolling circle amplification. Bacterial chromosomes are not efficiently amplified by the process and cannot be directly sequenced with our Sanger service. To sequence genomic DNA, use PCR to amplify the region of interest and submit the PCR products. Appropriate antibiotic selection was not used. If the selection antibiotic has degraded or was not added, the bacteria will often not retain the plasmid. Check the plates used for colony prep for antibiotic addition and expiration date. When in doubt, it is a good idea to throw out any old sleeves of plates nearing their expiration date and make a fresh batch. 10

Specific problems for glycerol stocks: no priming failures Low-copy plasmid used. These plasmids may not provide sufficient input DNA for efficient amplification. Use a vector with a high-copy origin of replication. Prep the DNA and submit purified plasmids. Use PCR to amplify the region of interest and submit PCR products for EndA+ strain used. Certain strains of E. coli (e.g. BL21, Stbl3) contain a non-specific endonuclease in the periplasmic space that can cleave plasmid DNA when cells are lysed, leading to inefficient amplification. Use a strain with the enda mutation (e.g. DH5α, TOP10). Prep the DNA and submit purified plasmids. Use PCR to amplify the region of interest and submit PCR products for Rich media used. Certain media (e.g. TB, SOB, 2YT) contain high salt concentration or ingredients that can inhibit polymerase activity during rolling circle amplification. Use LB medium. Submit bacterial colonies. Plasmid is greater than 20 kb. Rolling circle amplification is less efficient on larger templates. Use PCR to amplify the region of interest and submit PCR products for Cells do not contain a plasmid. Only small circular templates (i.e. plasmids) can be used successfully with rolling circle amplification. Bacterial chromosomes are not efficiently amplified by the process and cannot be directly sequenced with our Sanger service. To sequence genomic DNA, use PCR to amplify the region of interest and submit the PCR products. Appropriate antibiotic selection was not used. If the selection antibiotic has degraded or was not added, the bacteria will often not retain the plasmid Check the plates used for colony prep for antibiotic addition and expiration date. When in doubt, it is a good idea to throw out any old sleeves of plates nearing their expiration date and make a fresh batch. 11

Specific problems for phage: no priming failures Titer is too low or high. For phage supernatant, titers of 108 to 1012 PFU/mL can produce good results. However, you may need to perform a dilution series to determine the optimal titer for your samples. Alternatively, you can submit phage plaques. Phage with linear genome used. Only small circular templates can be used successfully with rolling circle amplification. If your phage has a linear genome, we recommend using PCR to amplify your region of interest and submitting the PCR products for Phage genome is greater than 20 kb. Rolling circle amplification is less efficient on larger templates. Use PCR to amplify the region of interest and submit PCR products for 12

Specific problems for BAC DNA: no priming failures DNA template concentration is too low. Most BAC DNA sequencing failures arise from templates that have either too low of a concentration or are low-quality. Double check that the DNA concentration is in the correct range. Review our Sample Submission Guidelines. Poor quality DNA template, including contamination with:.guanidine or other chaotropic salts.phenol or chloroform. EDTA.Ethanol or isopropanol Check the absorbance ratios on a spectrophotometer. Aim for values greater than 1.8. o A260/280 < 1.8 may indicate protein contamination. o 260/230 < 1.8 may indicate contamination with organic chemicals (e.g. guanidine, phenol or EDTA). This ratio is critical for successful We recommend eluting your DNA in molecular biology grade water and avoiding buffers containing EDTA, such as TE, which can inhibit the sequencing reaction. Tris-Cl, sometimes called EB buffer, is safe for For preps or cleanups, be sure to dry samples well prior to elution to avoid reagent carryover..check the integrity of your DNA on a gel. Sheared or fragmented DNA can lead to poor sequencing results. 13