Insulation Retrofit Options

Similar documents
Cladding Attachment Through Exterior Insulation Using Long Screws PHIUS 10 TH ANNUAL NAPHC, CHICAGO COLIN SHANE M.ENG, P.ENG 11 SEPTEMBER 2015

Structural and Hygrothermal Field Monitoring of Thick Continuously Insulated Wall Assemblies Utilized in a Multi-Story Residential Building

Insulation Fastener Guide IKO Ener-Air & IKO Enerfoil Wall Insulation

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

Cladding Attachment Over Thick Exterior Insulating Sheathing

Thermal Bridging in Building Thermal Envelope Assemblies: Repetitive Metal Penetrations

Thermal Bridging From Cladding Attachment Strategies Through Exterior Insulation

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

Pre-WWII Buildings. Performance? Environmental Separation. Mold, Rot, Corrosion, Decay, Recladding

Gold Bond BRAND Gypsum Sheathing

Attaching Cladding with Long Screws. Presented by: Michael Aoki-Kramer LEED AP

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

3/24/2017. Kohta Ueno. Building Science of Walls. March 24, Background Rhode Island AIA Presentation 2

FERO RAP TIE AND FAST SYSTEM THERMAL ANALYSIS

Attaching Cladding with Long Screws

Impact Resistance of Advanced Framed Wall Systems with Insulating Sheathing as the Primary Sheathing

Building Enclosure Concept Design Checklist

Continuous Insulation and Air Barriers for High Performance Walls

Rainscreen Gaps in Exterior Walls

Installation Guidelines

THERMAL BRIDGING OF MASONRY VENEER CLADDINGS & ENERGY CODE COMPLIANCE

Rainscreen. Insulation. Easy.

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION

Evolution of Wall Design for Controlling Rain Penetration

ENCLOSURE: SIMPLE LAYERS

UL Design System HW-D-1012 continued

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Building Envelope

2013 COMMERCIAL PRODUCTS

WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK )

SECTION NON--STRUCTURAL METAL FRAMING

BUILDING SCIENCE CORPORATION DIGEST OF INSULATED METAL PANELS PERFORMANCE REDEFINED

Cladding Attachment and Support

EE13-3 Improving Building Enclosures Thermal Performance as a Goal of Energy Efficiency. Paul E. Totten, PE Marcin Pazera, Ph. D.

1/2 in. (12.7 mm) and 5/8 in. (15.9 mm) glass mesh. It has an exceptionally hard, durable surface that can withstand prolonged exposure to moisture.

HIGH PERFORMANCE FIRE RETARDANT TREATED WOOD PRODUCTS

Technical Data Sheet

Background. Building Science of Walls. Environmental Separator. What Separation Roles? 1/25/2018. January 25, 2018

R-Matte Plus-3: Insulation for the Building Envelope

Insulated Metal Panel (IMP) Systems

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

Compliance for Continuous Insulation, Water Resistive Barriers & NFPA-285 What you need to Know

Thermal Control Layers: Insulation Materials and Systems

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

Framing Methods Structural Components

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE

Masonry Veneer - Chapter 6. Masonry Veneer Anchored Veneer

National Institute of Building Sciences

LIGHT-GAUGE PANELIZED WALL SYSTEMS. Michael Waggoner Mark Schroeder

Impact of NFPA 285 on Air Barrier Specification and Design

Building Enclosure Details and Assemblies for Wood-Frame Buildings

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

CONNECTOR B L O C K S H E A R. Design for Composite Structural Action BLOCK SHEAR CONNECTOR APPLICATION. Airspace

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

Wall Selection Guide Section 1.1

ProGUARD Guide Specification

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Chapters 4 through 10 address the prescriptive methods. Building Construction PART. Chapters 4 through 10

Prescriptive Wind Pressure Performance of Foam Plastic Insulation Used as Insulating Sheathing in Exterior Wall Covering Assemblies. TER No.

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

BEARING METAL STUD FRAMING

FIRE RATING MATERIAL FIXING NOTES

New Air and Vapor Barrier Technologies

Mid-Rise Wood Construction Builder s Guide ROCKWOOL COMFORTBOARD TM

Moisture Considerations for Insulated Building Assemblies

Welcome to this con-nuing educa-on seminar. This is the second of two parts of the High-Performance Building series.

Versetta Stone Panelized Stone Veneer Applications Over Continuous Insulation. TER No Boral Stone Products LLC

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

EXPLORE GEOMETRY AND SPACE

NFPA 285 Compliant Wall Systems and Assemblies

Better Buildings. Performance. Fundamentals. The Rules

TER No Cultured Stone & ProStone Applications Over Continuous Insulation

The better way to build TM. Installation Manual NAILBASE PANELS

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

The Importance of Slab Edge & Balcony Thermal Bridges

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

TER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Beginning of the Course

Thermal Performance of Northern Facades ISO Clip System Summary

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

Vertigo Cladding Board


Armatherm Structural Thermal Bridging Solutions

Investigation of Wind Projectile Resistance of Insulating Concrete Form Homes. by Ernst W. Kiesling, Ph.D., P.E. Russell Carter, BSCE, EIT

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

Sept 30, 2004 Page 1

NFPA 285 Assemblies. Table of Contents

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

SECTION GYPSUM BOARD ASSEMBLIES

Fastener Guidelines. Issued: 2015 Technical Communication - Fastener Guidelines DESIGN BASIS

STRUCTURAL TESTING OF SCREWS THROUGH THICK EXTERIOR INSULATION

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Transcription:

Overview Peter Baker Exterior Insulation: Strategies and Cladding Attachment Building Insulation Retrofit Strategies Exterior Insulation Approaches Insulation and Separate Cladding Exterior Insulation and Finish System (EIFS) Insulated Metal Panels Cladding Attachment Research November 16, 2017 Insulation Retrofit Insulation Retrofit Options Existing buildings are often un insulated/poorly insulated Insulation options are: Cavity fill Interior insulation Exterior insulation 1

Cavity Fill Insulation Cavity fill insulation is most common retrofit but has limitations 4 cavity for older wood frame ¾ cavity for mass masonry Interior Insulation Interior insulation retrofit concerns Continuity of insulation (partition walls, floors, etc.) Loss of floor space Occupant disruption Desirable if exterior appearance is needed/wanted to be maintained Often the best approach for historic buildings Not ideal from a building physics perspective Exterior Insulation Exterior insulation retrofit Ideal from a building physics perspective Can be completed with less disruption to occupants May come at a higher cost than other approaches Exterior Insulation New approach! New approach? Not a new approach Pesky Canadians Benefits discussed in Canadian Building Digests produced by the National Research Council of Canada in the 1960 s 2

Exterior Insulation CBD 44 (W.P. Brown, A.G. Wilson) Published in 1963 Application of insulation over the entire exterior of a wall provides an ideal solution to the problems presented by thermal bridges. It should be stressed that many of the thermal bridges occurring in present day construction can be avoided, or their effects minimized, if they are recognized in the early stages of design. The Perfect Wall Increase overall thermal performance Minimize thermal bridges Minimize potential for air leakage condensation Improve air tightness? Improve rainwater management? Exterior Insulation 1980s ON a weird builder 1990s ON a good builder 3

2000s ON a typical builder Exterior Insulation Approaches Insulation and cladding (discrete components) Exterior Insulation Approaches Exterior Insulation Approaches Insulation and cladding (discrete components) Exterior Insulation and Finish System (EIFS) 4

Exterior Insulation Approaches Insulation and cladding (discrete components) Exterior Insulation and Finish System (EIFS) Insulated Metal Panels (IMP) Used as a complete enclosure Exterior Insulation Approaches Insulation and cladding (discrete components) Exterior Insulation and Finish System (EIFS) Insulated Metal Panels (IMP) Used as a complete enclosure Used as an insulated cladding Brick Veneer Brick Veneer Brick veneer has some of the longest history with exterior insulation Long history = more common More common = less questions Not always well done 5

Brick Veneer Brick Veneer Brick Veneer Brick Veneer Alternate details and support options exist Support systems for brick can be modified for other building elements Decks Balconies Canopies Etc. 6

Brick Veneer Brick Veneer Other Claddings For insulation less than 1.5 direct attachment of cladding though insulation back to the structure is practical For insulation greater than 2 a secondary cladding support structure is often needed. Other Claddings Lighter weight claddings (metal/wood/fiber cement) Less common = less experience Less experience = more questions Cladding support systems historically done poorly Systems are getting better 7

Single z furring Other Claddings Poor thermal performance (steel stud wall on the exterior why bother?) Other Claddings Other Claddings Single z furring Double z furring Can be made to function reasonably well provided that two layers of insulation are used. Often designed with first layer bridging insulation and second layer creating a gap behind the cladding = single z furring Single z furring Double z furring Other Claddings 8

Single z furring Double z furring Clip and z furring or hat channel Metal clip Fiberglass clip Other Claddings Other Claddings Other Claddings Other Claddings Single z furring Double z furring Clip and z furring or hat channel Metal clip Fiberglass clip Attach furring directly back to structure through insulation 9

EIFS Exterior Insulation and Finish System (EIFS) Lightweight Cost effective Water managed Minimal Thermal Bridging R 4 per inch System has a tainted history Commonly installed using adhesive The adhesive can also form the drainage gap in water managed systems EIFS EIFS Insulated Metal Panels Insulated Metal Panels (IMP) Lightweight Moderate cost Water managed Minimal Thermal Bridging R 7.5+ per inch Can be an excellent enclosure system Requires some consideration for retrofit applications 10

Insulated Metal Panels Can be used as both a complete enclosure system Insulated Metal Panels Can be used as both a complete enclosure system Can also be used as an insulated cladding system Insulated Metal Panels Attachment often to metal hat channel or z furring In retrofit applications out of plane walls can require special adjustable systems or shims Insulated Metal Panels IMP as a complete enclosure system Provides all enclosure functions into a single system System design as intended by panel manufactures 11

Insulated Metal Panels IMP as a complete enclosure system May require special detailing for compartmentalization at floors or partition walls, particularly in retrofit applications Insulated Metal Panels IMP as an insulated cladding system Provides thermal insulation and cladding Rain water management and air tightness are provided by other elements Modification to manufacturers intended design Insulated Metal Panels (Retrofits) IMP as an insulated cladding system Need to fill space between the panel and back up wall to prevent air by pass of the insulation Can simplify certain details such as interfaces at balconies, lower roofs, and compartmentalization More in line with common construction detailing Cladding Support System: Direct Attachment Through Insulation 12

Background Industry trend to using exterior rigid insulation Increased thermal value Condensation resistance Increased air tightness (possibly) Increased rainwater management (possibly) Need to develop a means to attach cladding over thick layers of exterior insulation that can meet the following requirements: Provides good thermal performance Low cost Easy to construct/install (low cost) Background Current pneumatic nailers have maximum fastener lengths of 3 to 3.5 which limits insulation thicknesses to 1.5 max 3.5 fastener, ¼ to ½ siding, 1 ½ embedment (3.5 0.5 1.5 = 1.5 max insulation) Therefore, for insulation greater than 1.5 direct attachment of cladding though the insulation back to the structure is often not practical Direct Attachment Through Insulation Direct Attachment Through Insulation Wood structure 2 to 4 of exterior rigid insulation 1x3 wood furring strips Masonry Structure 2x4 framing attached to surface of masonry 2 to 4 of exterior rigid insulation 1x3 wood furring strips 13

Direct Attachment Through Insulation Lots of practical experience with this approach for lightweight cladding systems over thick layers of insulation (several decades). Approach has demonstrated very good long term performance High resistance from industry Compression resistance of insulation Long term creep Myths Does the insulation crush under load? YES! Loading a system until failure (500lbs to 1000lbs or more per screw fastener) will crush most rigid insulations..unfortunately that is the wrong question Myths Does the insulation crush under a load similar to what will be imposed on it in a cladding support application? The answer is no!... Typical Loads Typical cladding weights (psf) low high Vinyl 0.6 1.0 wood 1.0 1.5 Context is important fiber cement 3.0 5.0 stucco 10.0 12.0 adhered stone veneers 17.0 25.0 14

Typical Loads Typical weights per fastener (lbs) fastener spacing (in) 16" x 16" 16" x 24" 24" x 24" area/fastener (ft2) 1.78 2.67 4 vinyl 1.8 2.7 4.0 wood 2.7 4.0 6.0 fibercement 8.9 13.3 20.0 Design Criteria Acceptable deflection not ultimate capacity governs What is acceptable deflection? Movement a cladding system can accommodate without physical damage or exceeding aesthetic tolerances Proposed limit of 1/16 vertical deflection stucco 21.3 32.0 48.0 adhered stone veneers 44.4 66.7 100.0 BSC Cladding Attachment Research Began in 2011 Looking to expand on previous research Broken into two sections: mechanics of the cladding attachment system long term environmental exposure Full System Laboratory Tests Looked at initial response full system capacity as well as long term sustained loading Used full scale samples to limit variations in fastener installation 15

Full System Laboratory Tests Results Insulation type not a significant influence on system capacity System capacity is a function of the number of fasteners used High measured capacities and stable performance under controlled environmental conditions Load (lbs) 1000 950 900 850 800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 50 Full System Laboratory Tests Total Load vs. Vertical Displacement of Furring Strip over 4" of PIC Insulation 8 oc (13 Fasteners) 16 oc (7 Fasteners) 24 oc (5 Fasteners) 0 0.00 0.02 0.03 0.05 0.06 0.08 0.09 0.11 0.12 0.14 0.15 0.17 0.18 0.20 0.21 0.23 0.24 deflection (in) 4" Thermax 24" OC 4" Thermax 16" OC 4" Thermax 8" OC 75 70 Full System Laboratory Tests Per Fastener Load vs. Vertical Displacement of Furring Strip over 4" PIC Insulation BSC Cladding Attachment Research System Mechanics 65 60 55 50 45 Load (lbs per fastener) 40 35 30 25 20 15 10 5 0 0.00 0.02 0.03 0.05 0.06 0.08 0.09 0.11 0.12 0.14 0.15 0.17 0.18 0.20 0.21 0.23 0.24 defelction (in) 4" Thermax 24" OC 4" Thermax 16" OC 4" Thermax 8" OC 16

Cantilever Double Bending Screw Shaft Bearing Screw Bending Screw Bending Double bending resistance was significantly higher (~4 times) than simple cantilever. Double bending is more in line with the expected performance of the assemblies but still only accounted for a fraction of the total measured system capacity Screw shaft bearing on the insulation was hard to quantify, but appeared to be significant in short term (initial response) tests Load per fastener (lbf) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Screw Bending Load vs. displacement for #10 wood screws under simple cantilever and double bending y = 65.263x y = 13.223x 0 0.015 0.03 0.045 0.06 0.075 0.09 0.105 0.12 0.135 0.15 0.165 0.18 0.195 0.21 0.225 0.24 Deflection (inches) Compression Forces Coefficients of Friction System Friction #10 Cantilever #10 Double Bending Linear (#10 Cantilever) Linear (#10 Double Bending) 17

System Friction Compression Forces were measured at around 150lbf/fastener to drive a #10 wood screw flush with face of furring Coefficients of frictions were typically around 0.25 Compression forces were also measured to drop off over time (around 20% to 30%) after initial loading and be highly sensitive to environmental conditions Function of fastener tension and insulation compression Measured insulation compression properties Difficult to measure directly Fastener bending present Hard to create a frictionless system May have a more significant contribution in the form of additional friction than compression resistance Compression Strut Exterior Exposure Testing Looked at long term movement of systems under sustained loads in an exposed environment Deflection (in) Exterior Exposure Testing Vertical deflection movement of a wood furring strip (loaded to 8lbs/fastener) over time in an exposed environment 0.50 100 0.48 0.45 0.43 0.40 80 0.38 0.35 0.33 0.30 60 0.28 1/4" 0.25 0.23 0.20 MF and PIC assemblies 40 0.18 loaded at this time 0.15 1/8" 0.13 0.10 20 0.08 1/16" 0.05 1/32" 0.03 0.00 0 0.03 0.05 1/32" 0.08 0.10 20 7/1/12 8/31/12 10/31/12 12/31/12 3/2/13 5/2/13 7/2/13 9/1/13 Date MF installed but not loaded during this time Temperature (F) / Relative Humidity (%) XPS EPS MF PIC Temperature RH 18

Deflection (in) Exterior Exposure Testing Vertical deflection movement of a wood furring strip (loaded to 15lbs/fastener) over time in an exposed environment 0.50 100 0.48 0.45 0.43 0.40 80 0.38 0.35 0.33 0.30 60 0.28 1/4" 0.25 0.23 0.20 MF and PIC assemblies 40 0.18 loaded at this time 0.15 1/8" 0.13 0.10 20 0.08 1/16" 0.05 1/32" 0.03 0.00 0 0.03 0.05 1/32" 0.08 0.10 20 7/1/12 8/31/12 10/31/12 12/31/12 3/2/13 5/2/13 7/2/13 9/1/13 Date MF installed but not loaded during this time Temperature (F) / Relative Humidity (%) Deflection (in) Exterior Exposure Testing Vertical deflection movement of a wood furring strip (loaded to 30lbs/fastener) over time in an exposed environment 0.50 100 0.48 0.45 0.43 0.40 80 0.38 0.35 0.33 0.30 60 0.28 1/4" 0.25 0.23 0.20 MF and PIC assemblies 40 0.18 loaded at this time 0.15 1/8" 0.13 0.10 20 0.08 1/16" 0.05 1/32" 0.03 0.00 0 0.03 0.05 1/32" 0.08 0.10 20 7/1/12 8/31/12 10/31/12 12/31/12 3/2/13 5/2/13 7/2/13 9/1/13 Date MF installed but not loaded during this time Temperature (F) / Relative Humidity (%) XPS EPS MF PIC Temperature RH XPS EPS MF PIC Temperature RH Relative Deflection (in) Exterior Exposure Testing Diurnal Movement of the Furring Strip with Respect to the Stud Framing (recorded over a three day period) 0.03 100 0.025 90 0.02 80 0.015 70 0.01 60 0.005 4E 17 50 0.005 40 0.01 30 0.015 20 0.02 10 0.025 0.03 0 12/31 00/01 12/01 00/02 12/02 00/03 12/03 Time and Date (hours/day) Temperature and Relative Humidity ( C, %) Conclusions (System Mechanics) Initial load response measurements are on the order of 40 to 50lbf/fastener at 1/16 deflection and 4 of insulation Insulation type does not appear to be overly significant Capacity is a function of the number of fasteners used. Capacity would be expected to increase for less insulation due to higher fastener component at a smaller cantilever Friction component is significant, but highly variable due to initial clamping magnitudes and thermal expansion and contraction of materials Compression strut component is present, however the magnitude of the impact is difficult to quantify. Deflection T Corrected (in) Ambient Air Temperature ( F) Relative Humidity (%) 19

Conclusions (Long Term Exposure) System creep was apparent at high per fastener sustained loading (30lbs/fastener) At low per fastener loads (8lbs/fastener) the system demonstrated stable performance At moderate per fastener load (15lbs/fastener) the system demonstrated relatively stable performance, though there is some possible slight indication of system creep Recommendations Based on the results of the testing it is currently recommended to use a maximum load per fastener of no more than 10lbs for up to 4 of insulation Vertical fastener spacing (in) per cladding weight Cladding weight (psf) 16 oc Furring 24 oc Furring 5 18 12 10 9 6 15 6 4 20 4 3 25 3 2 20