The ecological choice. Besblock STAR PERFORMER. The multi-purpose energy saving block JULY 2014 UNIVERSAL, COST EFFECTIVE, DELIVERABLE

Similar documents
CONCRETE BLOCKS Lignacite

CONCRETE BLOCKS Lignacite

Toplite _ aircrete blocks. from Tarmac Topblock

Part E robustdetails. robustdetails. September 2015 Update Pack. Dear Colleague,

BREEDON BLOCKS.

June Residential Refurbishment Separating walls

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation

HP Partial Fill. Robust, long-lasting protection

9 Revision B

CI/SfB Ff November Product Selector & Range Guide Concrete block masonry

December 2005 Cl/SfB Ff4. Acoustic Compliance

A Handbook of thermal bridging details incorporating aircrete blocks

ROCKFLOOR. Thermal and acoustic stone wool insulation for ground and separating floors

CI/SfB. November Design Guide Concrete block masonry

A Handbook of thermal bridging details incorporating aircrete blocks

Aircrete Blocks. Product Guide. a Forterra brand

Acoustic Cradle Levelling System

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation.

Insulated Ground Floors

Thermally Broken Lintel Product Selector

A handbook of thermal bridging details incorporating Porotherm blocks

Approved Document E Technical Design Report

How glass or rock mineral wool works in a wall or floor cavity

Floors Walls Roofs. Jabfill Premium. APPLICATION: Full-fill Cavity Wall Insulation PRODUCTS: Vencel Resil Limited

Why party wall insulation is required

850 SOLID LIGHTWEIGHT READYBLOCK

CONCRETE BLOCK MASONRY

Robust details. Section 5 robust details. Robust Details Limited Davy Avenue Knowlhill Milton Keynes MK5 8NB

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes.

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

Part E robustdetails. robustdetails. January 2018 Update Pack

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

Insulation options. Calculating U-Values

Superior Performance Phenolic Insulation. SR/CW Insulation for Partial Fill Cavity Walls. Walls AS LOW AS 10/4803

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

Dwelling-houses and flats performance standards for separating walls, separating floors and stairs that have a separating function.

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes.

June Residential Refurbishment Separating floors

POLTERM MAX PLUS. Non combustible stone wool insulation for ventilated rainscreen cladding and overcladding systems. isover.co.uk

June Non - Residential New Build Partition walls

SAP Calculations. Acheson Construction. Project: Plot 8, Neils View Maiden Newton. Contact: James Frampton Trinity Architecture

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

BISON PRECAST FLOORING SPECIFICATION

FIBOLITE MAKING LITE OF PART E REGULATIONSNS

GypLyner UNIVERSAL Metal framed wall lining system

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

PIR Insulation XT/CW (T&G) Insulation for Partial Fill Cavity Walls. Walls 08/ /0183

GypLyner UNIVERSAL Metal framed wall lining system

ROCKWOOL BUILT IN CAVITY WALL INSULATION BATTS ROCKWOOL CAVITY WALL BATT

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

Aircrete blocks product guide

FIBOLITE MAKING LITE OF PART E REGULATIONSNS

June Residential Refurbishment Basements

STRESSLINE LIMITED LINTEL GUIDE JULY LINTEL GUIDE 2014

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD

DUROX AIRCRETE BLOCKS SUPABLOC 10

External Walls Thermal Performance

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm

Suspended timber upper floors

Refurbishment site guidance for solid-walled houses ground floors

Certificate No: EWWS546

June Non - Residential Refurbishment Separating floors

WARMFLOOR. Installation Guide.

June Non - Residential Refurbishment 5.5 Basements

WARMFLOOR. Installation Guide.

An introduction to Part L U-values

April Section 4.3. Separating Floors

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+

Wall lining Inner leaf blockwork. K106 Cavity Board. Flexible sealant STANDARD DETAILS FOR 115 MM INSULATION BOARD IN A 125 MM CAVITY

Agrément Certificate 17/5474 website: Product Sheet 1

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

Concrete Blocks Product & Technical Guide. Thomas Armstrong (Concrete Blocks) Ltd. Incorporating

TCB & PWCB CAVITY BARRIERS Fire Protection for timber/steel frame & masonry cavity walls

THERMALITE AIRCRETE BLOCKS AND THIN-JOINT SYSTEM TURBO

Part E robustdetails. robustdetails. June 2018 Update Pack. Dear Colleague,

EasylationWall. External Wall Insulation System. bringing european innovation

Achieving CfSH Levels 4, 5 and 6

Resistance to the passage of sound

Resistance to the passage of sound

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183

Building Regulations

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Housing Easy Guide: Cavity Walls


a new liquid screed solution from

TECHNICAL. Cavity Wall Partial - Fill Insulation. Stylite.

April Section Party Walls

TIMBER FRAME HOUSING SOLUTIONS

Structural Products. Multideck 50-V3 Galvanised Steel Floor Decking System

Internal Wall and Floor Insulation with Marmox Multiboard

RW SEMI-RIGID AND RIGID SLABS (RWA45, RW3, RW4, RW5 & RW6)

Transcription:

Besblock STAR PERFORMER UNIVERSAL, COST EFFECTIVE, DELIVERABLE The multi-purpose energy saving block The ecological choice JULY 2014 UNIVERSAL, COST EFFECTIVE, DELIVERABLE besblock.com

Besblock STAR PERFORMER The Besblock Star Performer is a multi-purpose, one-block, on-site solution aimed essentially at the domestic housing market. Multi-purpose applications When using the Star Performer block, particularly for house building, a one-block solution is accomplished as the Star Performer meets the required criteria for: Inner leaf of external wall Sound resisting separating (party) walls Infill units for beam and block floors Use below damp-proof course level ECO credentials 24 The product contains voids (24% of total block volume) which, when built, act as unventilated air cavities within the block, enhancing its thermal and acoustic performance. % LESS aggregate in manufacture % LESS water used in manufacture % LESS energy used to cure the concrete % INCREASED payload on delivery vehicles BUILDING REGULATIONS 2010 (2013 EDITION) L1A TER / TFEE CONSERVATION OF FUEL AND POWER IN NEW DWELLINGS Thermal properties The thermal properties closely resemble those of a solid medium density (F.B.A.) block, but when built into the wall, heat loss is shown to be greatly reduced at thermal junctions when the Star Performer block s bespoke Ψ and Kappa values are entered into the SAP calculation. This has the distinct advantage of reducing the overall heat loss through the buildings envelope. A Ψ value summary for all junctions and junction detail drawings may be downloaded at www.besblock.co.uk UNIVERSAL, COST EFFECTIVE, DELIVERABLE besblock.com

Three splitter cores make cutting easy Five bridges give transverse strength of 4.5kN Plaster direct No special precautions or surface preparations required Available in standard and paint grade textures Solid mortar bed Blocks should be laid void down Dense aggregate composition provides an exceptional strength-to-weight ratio of up to 10.4N/mm 2 at 15kg Still air trapped in voids dramatically improves thermal and acoustic performance Technical specification Unit weight @ 3% moisture (approx.) 14.5 kg Weight laid / m 2 (approx.) 154 kg/m 2 Gross density of unit (approx.) 1554 kg/m 3 Net concrete density (approx.) 1900 kg/m 3 Effective lambda value Thermal resistance 0.649 W/mK 0.154 m 2 K/W *Compressive strength 3.6N/mm 2 : 7.3N/mm 2 : 10.4N/mm 2 Bespoke Kappa value Void percentage (approx.) 24% Moisture movement Number per pack 95.5 k J(m 2 K) plasterboard finish 126.1 k J(m 2 K) gypsum finish 0.5mm / m 9m 2 (90 blocks) Thickness of concrete shell 27.5mm Manufacturing category BS EN 771-3:2011 Category 1 BS EN 1996-1-1 Group 1 Finishes available Standard : Paint Grade *Note: The compression test is taken over the whole bed area of the block including the void areas.

Section 1 Thermal insulation external wall Typical external wall U-values with brick outer leaf and internal finish of plasterboard on dabs. Type of insulation Lambda value of Cavity width U-value insulation (W/mK) (mm) (W/m 2 K) Full fill blown bead 0.033 100 0.27 Full fill blown bead 0.033 125 0.23 Full fill blown bead 0.033 150 0.19 Full fill mineral wool slab 0.032 100 0.27 Full fill mineral wool slab 0.032 125 0.22 Full fill blown mineral wool 0.037 150 0.21 Full fill mineral wool slab 0.032 150 0.19 Full fill blown mineral wool 0.034 100 0.28 Full fill blown mineral wool 0.034 125 0.23 Full fill blown mineral wool 0.034 150 0.20 PU / PIR board 50mm partial fill 0.022 100 0.28 PU / PIR board 75mm partial fill 0.022 125 0.22 PU / PIR board 100mm partial fill 0.022 150 0.18 Full fill CavityTherm 95mm PIR board 0.021 100 0.19 Full fill CavityTherm 120mm PIR board 0.021 125 0.16 For other U-values not covered in the table, please contact our Technical Services Department who will provide this information: technical@besblock.co.uk Section 2 Sound resisting separating walls: Approved Document E Building Regulations Part E1 Compliance with the Robust Detail Scheme demonstrates compliance with the relevant Building Regulations in England, Wales, Scotland and Northern Ireland, without the need for pre-completion testing. Robust Detail (RD) constructions must be capable of consistently exceeding the performance standards given in Approved Document E to the Building Regulations of England and Wales, at the same time as being reasonably tolerant to workmanship. The table below lists the RD s currently applicable to the Star Performer block when used in England, Wales and Northern Ireland only. RD number C.S.H. Min cavity Cavity Parge coat Internal Floor credits width (mm) insulation required finish (flats) E-WM-5 1 75 *75mm mineral wool. Yes Gypsum based Max density 40kg/m 3 (optional) board 8kg/m 2 E-WM-8 1 75 35mm Isover RD 35 No Gypsum board 9.8kg/m 2 E-WM-11 3 100 *100mm mineral wool. Yes Gypsum based Max density 40kg/m 3 (optional) board 8kg/m 2 E-WM-17 3 100 100mm Isover RD Party Wall Roll No Gypsum based or Isover Round The House Roll board 9.8kg/m 2 E-WM-26 1 100 100mm mineral wool roll quilt or No Gypsum based batts of density range board 10kg/m 3 12kg/m 3-25kg/m 3 E-FC-1 E-FC-12 E-FC-13 E-FC-14 E-FC-4 E-FC-5 E-FC-8 E-FC-9 E-FC-10 E-FC-11 E-FC-15 E-FC-16 E-WM-19 4 100 *100mm mineral wool roll quilt Yes Gypsum based This system is for MONARFLOOR or batts of max density board on dabs adjoining houses only. BRIDGESTOP system. 40kg/m 3 (optional) (8kg/m 3 ) on sand & Not suitable for use (Adjoining houses only) cement render coat. in flats. (1) The inner leaf of the external wall may be constructed of Star Performer blocks in all of the above RD. (2)*The insulation within the party wall cavity is used to reduce convection of heat into the roof space to improve the dwellings emission rate. (Part L requirement) Where the detail is marked*, the cavity insulation IS OPTIONAL. However if it is excluded the DER will increase.

Note: RD specifications refer to separating (party walls) between dwellings. Walls separating living spaces within a flat or dwelling, from other parts of the same building that are not used exclusively with that flat or dwelling, e.g. separating walls forming stairwell walls, service corridors, and hallways etc., are not covered by RD protocol. Regulation E1 requires that these walls have a Dn,Tw + Ctr rating of 45dB. Whilst Approved Document E does not require that these walls be subject to on-site testing, the terminology Dn,Tw + Ctr does refer to an on-site test. Building Control need to be satisfied that corridor and stairwell walls etc. comply with the requirements of E1, and building in accordance with an RD specification is one way of achieving this. 275mm cavity separating wall Access corridor unheated Flat/apartment heated Stairwell unheated 275mm cavity separating wall Building Regulation E2(a) E2(a) refers to dwelling-houses, flats and rooms for residential purposes. It requires that walls within, between a bedroom or a room containing a water closet, and other rooms provide reasonable resistance to sound. (Exclusion: an internal wall separating an en suite toilet from the associated bedroom.) Wall designation Approved Doc wall reference Requirement Solution Internal wall between Internal wall type C: Concrete Rw 40dB Single skin Besblock a bedroom, or a room block wall plaster or plasterboard Star Performer plastered containing a water closet: on both sides or dry lined both faces and any other rooms. Section 3 Beam and block floors The 7.3 N/mm 2 Star Performer block is suitable to act as infill units for beam and block flooring systems surpassing the minimum loading requirements stated in Table 1 BS 6399-1: 1996 for domestic and residential activities, and those required by the Precast Flooring Federation. Fig 6 The Precast Flooring Federation require that blocks for use within floor beams should be of 7.3N/mm 2 compressive strength or capable of sustaining a central load applied via a 100mm 2 steel plate of 3.5kN on a span of 420mm. The 7.3N/mm 2 Star Performer block is able to support a central point loading of 4.5kN on a 420mm span. 7 Fig 7 We are able to supply infill slip and cavity closer blocks to maintain coursing height if required. See diagrams for guidance in use. Guidance notes: Always specify blocks with 7.3N/mm 2 for this application. Where it is necessary to cut blocks to size always cut to and not beyond a bridge (see fig 6). If inconvenient use a Bescrete solid block 440 x 215 x 100 from which to cut portion size required. Where the block bears on, and forms part of the foundation wall, the laid flat compressive strength of the areas that are likely to be subject to load, assuming the bearing wall to be of 100mm thickness is:- Fig 8 1. 440 x 100 = 5.0N/mm 2 (see fig 7) 2. 215 x 100 = 4.0N/mm 2 (see fig 8) Ensure that the floor is constructed and finished in accordance with the manufacturer s instructions.

Section 4 Star Performer in walls below damp-proof course Introduction: Star Performer blocks have been used below damp-proof course for many years where they have proved to be durable, efficient and economical. They permit fast on-site working since their dimensions are equivalent to six bricks. Requirement: Star Performer Blocks comply with the requirements of BS 5628: Part 3: 2005: table 12 and PD6697 Table 15 and as such are suitable for use below ground level damp-proof course. Having a gross density of 1554kg/m 3 and being manufactured from dense aggregates to BS EN 12620 and having a concrete strength of 7.3N/mm 2, renders them suitable for use below damp-proof course in both the internal and external leaves of a cavity wall. Where sulphate soils have been identified, Star Performer blocks can be used in up to and including class DS-3 equivalent sulphate soil classification (see table below). Sulphate soil classification Requirements DS-1 Aggregate concrete blocks meeting the requirements of BS 5628: Part 3: Table 12 and PD 6697 Table 15. Star Performer blocks meet the criteria. DS-2 and DS-3 Aggregate concrete blocks meeting the following requirements. a) Specified block strength 7.3N/mm 2.. b) Blocks should be manufactured from dense aggregates to BS EN 12620. For this soil application specify the Star Performers to 7.3N/mm 2. Mortar A mortar containing 1:1:5-6 cement: lime: sand (or equivalent) or a general purpose mortar is commonly used below ground level. Points to watch: ALWAYS lay blocks void down. Do not lay blocks flat. Section 5 Cutting and chasing the Star Performer Ten per cent of all Star Performer blocks come with three in-built splitter cores. These enable the block layer to easily achieve ¼, ½, or ¾ of a block. If cutting is required where splitter blocks are not selected from the pack, always use a mechanical cutter. Likewise, where walls require chasing to accommodate service pipes etc. always use a mechanical cutter. The chases in the image (right) are typically 35mm wide. It is quite acceptable to cut a chase through to the void within the block. Testing has demonstrated that this does not affect the block s structural integrity. Section 6 Fixing to cellular blocks There is a common misconception within the industry that solid blocks will accept and provide a stronger and more rigid fixing than will cellular blocks (blocks containing voids). As one of the UK s foremost manufacturers of cellular blocks we have long suspected that there is little physical foundation or evidence to support this theory. Recent comparative tests have been conducted for both Tensile and Shear on 440mm x 215mm x 100mm Besblock Solid Medium Density blocks and Besblock Cellular Star Performer blocks. Standard M8 Anchor fixings were inserted into the blocks. In the case of the Cellular Star Performer block, the fixing passed through the 27.5mm shell, penetrating approx. 25.5mm into the void. Tensile tests were conducted in accordance with the requirements of BS5080: Part 1: 1993. Shear Tests were conducted in accordance with the requirements of BS 5080: Part 2: 1986. The tests were conducted by Lucideon Ltd. Lucideon is a UKAS accredited laboratory. The face size of the blocks tested was 440mm x 215mm.

Block type Max Load (kn) Max load (kg) SUMMARY OF TEST RESULTS: TENSILE STRENGTHS OF FIXINGS INSTALLED INTO BLOCKS (MEAN of 5) 100mm Cellular Star Performer 6.39 652 100mm Solid Besblock Medium Density 5.12 522 SUMMARY OF TEST RESULTS: SHEAR STRENGTHS OF FIXINGS INSTALLED INTO BLOCKS (MEAN of 5) 100mm Cellular Star Performer 15.33 1556 100mm Solid Besblock Medium Density 15.16 1545 Full test report available on request The strength of the concrete and its ability to retain fixings will depend on the concrete mix and its cement content. Very importantly however, the efficiency of the block machine and how it vibrates binding the concrete mix together, will determine the final strength and performance of the concrete product. At Besblock we employ American Columbia block machines. These are world renowned for their unicontrolled vibration systems. Where cellular blocks such as the Star Performer are being manufactured, case hardened steel core bars will be present in the steel mould box. When the vibration is applied to compact the concrete mix therein, the mix material will be forced against the outer constraints of the mould box, but also against the core bars within the mould, thereby receiving compaction from four sides. As a result, the concrete contained in the cellular block will have a greater density than its equivalent in solid format, thereby providing greater strength. Section 7 Technical services We re pushing the boundaries on customer service With the ever increasing complexity of the Building Regulations and the continual changes being made to them, Besblock has long realised the requirement that customer service should exceed purely the on-time delivery of a good quality building block. The product has many stringent regulations to satisfy in the thermal, acoustic and structural fields. To enhance our customer service, Besblock Technical Services began in 1995. Their purpose is to guide house builders through this labyrinth of regulations with a view to obtaining a Pass for the developer by the most cost effective of specifications. As members of National Energy Services AND Stroma, we are fully qualified to offer: Full energy advisory service. Our assessors never adopt the fast and easy default method. They will give a great degree of thought in every case to how to meet the regulations by the most cost effective method. Where necessary, this will involve full discussions with you, the client. Full documentation for presentation to Building Control to get you started on site. This includes a Building Regulations check list, a SAP Data Sheet, full SAP Work Sheet and a Predicted Energy Assessment (PEA). Air Leakage Testing. When your project is complete, our fully qualified and BINDT (British Institute of Non Destructive Testing) approved test engineers are on hand to assess the Air Tightness of the finished building. Results are usually issued electronically on the same day as the test, enabling fast CML completion. AND FINALLY. Production of your EPC, conforming to the as built specification necessary for the signing off of your dwelling(s) before you can offer for sale/occupation. For Air Leakage Testing book on line at www.besblock.co.uk or telephone Technical Services 01952 685000

Besblock STAR PERFORMER Better acoustic insulation Greater thermal insulation Smarter multi-purpose, one-block, on-site solution Greener 24% less water, aggregate, and energy used in manufacture If you would like further information about the Besblock Star Performer please contact us Besblock Ltd Heslop Halesfield 21 Telford Shropshire TF7 4NF technical@besblock.co.uk besblock.com 01952 685000 Every effort has been made to ensure that the information in this brochure is correct at the time of going to press. However, to improve product performance and ensure its on-going compliance with the Building Regulations, the manufacturer reserves the right to change the specification of the product or amend published construction details relating to its use without prior notice. It is the responsibility of the specifier to ascertain the suitability of Besblock products for a given project or application prior to purchase or use. (Our Technical Services department will be pleased to advise on this at any time.) UNIVERSAL, COST EFFECTIVE, DELIVERABLE besblock.com