Detail Set: Thermax Wall System Masonry

Similar documents
Foam Vs Fiber. Air Sealing Benefit of Foam in Single Family Residential New Construction. Gary Parsons Fellow, Dow Building Solutions R&D

TECH SOLUTIONS A Prescriptive Solution to Meet Air Barrier Energy Code Requirements in Metal Buildings

TECH SOLUTIONS THERMAX Insulation in Low Humidity Metal Buildings

Ultra Wall System. CAD Detail Sets

THERMAX Wall System. CAD Detail Sets

Tech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide

Installation Procedures for the Ultra Air Barrier Wall System

Short Form Guide Specification. STYROFOAM CAVITYMATE Ultra Air Barrier Wall System

Improve Energy Efficiency and Air Sealing in Above-Grade Walls

Increase Energy Efficiency With STYROFOAM Brand CAVITYMATE Products

Above Grade Wall Systems by Dow

TECH SOLUTIONS LEED for Homes: Achieving. Points With Dow Building Solutions Products

Improve Energy Efficiency and Moisture Performance of Foundations

United States R E S I D E N T I A L. The Value of Residing With STYROFOAM Brand XPS Insulation

STYROFOAM BRAND ULTRA SL Air Barrier Wall System w/ Flashing Tape Installation of Rigid Foam on CMU Backup

Dow Building Solutions. Below Grade Systems by Dow

Figure 1 Brick & Block Cavity Wall

Improve Energy Efficiency and Moisture Performance of Foundations

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

an extensive line of science-based solutions residential. united states

For GREAT STUFF PRO Window & Door Insulating Foam Sealant

Opaque Envelope Basis of Design Rainscreen Cladding w/ Dow THERMAX Wall System

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

Technical Data Sheet

Reduce Wall Condensation Potential with Insulated Sheathing TECH SOLUTIONS 214.0

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 2

Short Form Guide Specification. THERMAL, WATER, AND AIR BARRIER WALL ASSEMBLY [Public Bid]

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 3

KNIGHT WALL SYSTEMS GUIDE DETAILS:

NFPA 285 Assemblies. Table of Contents

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 6

TECH SOLUTIONS Hot Box Testing of Four Different Metal Building Roof Assemblies Determines Insulation Efficiency

TECH SOLUTIONS Reduce Wall Condensation Potential with Insulated Sheathing

Reduce Wall Condensation Potential with Insulated Sheathing TECH SOLUTIONS 214.0

KNIGHT WALL SYSTEMS GUIDE DETAILS:

Improve Energy Efficiency and Air Sealing in Above-Grade Walls

WeatherSmart Air Barrier Installation Guide

KNIGHT WALL SYSTEMS GUIDE DETAILS:

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

NFPA 285 Compliant Wall Assemblies with Perm-A-Barrier Air Barriers Walls Containing Mineral Wool Insulation

DuPont Flashing Systems Commercial Installation Guidelines

KNIGHT WALL SYSTEMS GUIDE DETAILS:

NFPA 285 Assemblies. Table of Contents

DuPont Flashing Systems Commercial Installation Guidelines

SECTION SELF-ADHERING SHEET FLASHING

KARRIER PANEL - BRICK

Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

THERMAL AND AIR BARRIER WALL SYSTEM

STEEL STUD DESIGN GUIDE VAPOR / DEW POINT ANALYSIS

United States SELECTOR GUIDE. Metal building products

WEIGHT PER PIECE (LBS.)

Guide Specification for the OSI QUAD Window and Door Flashing System

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

CommercialComplete Wall System

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

Finestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

Acrocrete Platinum CI Stucco Ultra Typical details for a premium impact and puncture resistant rain screen design cement plaster stucco system

Insulation manufacturer to submit dew point analysis free of charge for typical wall section. Analysis by:

INSTALLATION INSTRUCTIONS ENERGYSHIELD AND RBOARD USE IN CANADA

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

INSTALLATION INSTRUCTIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Henry NFPA 285 Air Barrier Assemblies

Impact of NFPA 285 on Air Barrier Specification and Design

The better way to build TM. Installation Manual NAILBASE PANELS

Dow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green

United States SELECTOR GUIDE. Residing products

Professionally Sealed with GREAT STUFF PRO Products Seal Out Energy Loss. Seal In Comfort.

Construction Standards PAGE

Henri Fennell, CSI/CDT ABX 2015

GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50

Product and System Specifications DuPont Flashing Systems

(Project Location) (your firm's name)

Make your Mark. Make a Difference. Thermal, Air & Moisture Management for the Building Envelope

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

SECTION FOIL FACED POLYISOCYANURATE FOAM BOARD INSULATION. A. Rigid polyisocyanurate foam board insulation with aluminum facers.

Senturion TM I Wall System

Perm-A-Barrier VPS (Vapor Permeable Sheet)

HP+ Wall System X Series Technical Installation Manual

THERMAL AND MOISTURE PROTECTION

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

Senturion TM III Wall System

ProGUARD Guide Specification

DUPONT TYVEK MECHANICALLY FASTENED AIR AND WATER BARRIER INSTALLATION GUIDELINES FOR BUILDINGS GREATER THAN 4 STORIES AND HIGH PERFORMANCE

R-Matte Plus-3: Insulation for the Building Envelope

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

SRP-AirOutshield UV Issued:

Complete Solutions for Commercial Construction Thermal, Air & Moisture Management for the Building Envelope

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

MID-RISE DESIGN & CONSTRUCTION

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Transcription:

Dow Building Solutions Detail Set: Thermax Wall System Masonry This detail set outlines the masonry guidelines for design using the THERMAX Wall System, focusing around attachment of masonry façades and the continuity of the four control layers (thermal, air, vapor, and water). The THERMAX Wall System is an innovative way to achieve complete, long-term protection. With three simple components continuous insulation, all-weather flashing, and an insulating air barrier you get one integrated system that insulates and seals against water, air, and vapor more effectively for ultimate long-term envelope protection. As codes become increasingly more demanding, designers are constantly challenged to find new ways to meet them. Dow s THERMAX Wall System meets all applicable IBC and ASHRAE requirements using industry-proven products for greater results saving you money and increasing profitability for your business. CONTENTS Masonry Overview Section... 1 Anchor Guidelines on Stud... 2 Anchor Guidelines on CMU... 3 Foundation... 4 Windows Brick Return... 5 Edge of Slab... 6 Supplemental / Cladding-Specific Detail Sets General (Cladding Neutral) Rain Screen (Metal Panel, Terra Cotta, Fiber Cement Panels, etc.) Applied (Adhered Stone, Stucco, etc.

Masonry Details Overview DETAILS GUIDE 1. WALL SECTION LISTS APPLICABLE DETAILS FOR REFERENCE. 2. DETAIL NAMING SYSTEM: TWS-X000.0.0 - DETAIL NUMBER ON PAGE 000 - DETAIL NUMBER IN SET G - GENERAL M - TWS - THERMAX TM WALL SYSTEM 3. FULL DETAIL SETS FOR "TWS-G" AND "TWS-M" AVAILABLE AT DOWBUILDINGSOLUTIONS.COM PARAPET DETAILS TWS-G015.1 TWS-G015.2 TWS-G016.1 TWS-G016.2 EDGE OF SLAB DETAILS TWS-G012.1 TWS-G012.2 TWS-M006.1 TWS-M006.2 WINDOW DETAILS TWS-G009.1 TWS-G009.2 TWS-G009.3 TWS-G009.4 TWS-G010.1 TWS-G010.2 TWS-G010.3 TWS-G010.4 TWS-M005.1 TWS-M005.2 TWS-M005.3 FOUNDATION DETAILS TWS-G007.1 TWS-G007.2 TWS-G007.3 TWS-G007.4 TWS-M004.1 TWS-M004.2 OVERVIEW SECTION TWS-M001 COLOR FOR VISUAL CLARIFICATION ONLY 1. ACCEPTABLE DETAILS INCLUDE, BUT ARE NOT LIMITED TO, THOSE LISTED ABOVE. MUST REFERENCE THERMAX WALL SYSTEM GENERAL DETAILS (CLADDING NEUTRAL) FOR OTHER MIN. REQUIREMENTS. 1

Anchor Guidelines for Studs Design Intent 1. USE SELF-SEALING ANCHORS TO MAINTAIN INTEGRITY OF 4 CONTROL LAYERS. 2. SELECT FASTENERS WITH THERMAL BREAKS TO IMPROVE EFFECTIVE R-VALUE OF THE ENVELOPE. 3. USE BARREL-LIKE FASTENERS TO REDUCE NUMBER OF PENETRATIONS TO ENVELOPE. 4. SEAL UNEVALUATED FASTENERS WITH SELF-SEALING DOW MEMBRANES. Masonry Anchor Recommendations EVALUATED SELF-SEALING BARREL STYLE ANCHORS HECKMANN POS-I-TIE WITH RODENHOUSE THERMAL-GRIP CI WASHER HOHMANN & BARNARD 2-SEAL TM TIE, 2-SEAL THERMAL WINGNUT ANCHOR, & THERMAL 2-SEAL TIE WIRE-BOND SURE TIE WITH THERMAL WASHER ANCHORS REQUIRING ADDITIONAL FLASHING HOHMANN & BARNARD: DW-10X SERIES, HB200/213 SERIES WIRE-BOND: HCL SERIES, TYPE III X SERIES LIST NOT EXHAUSTIVE. SELF -SEALING BARREL FASTENERS (RECOMMENDED) TM ENGINEERED TIE (HIGH RISE) (5) REQUIRES ADDITIONAL FLASHING / SEALANT LIQUIDARMOR TM OR WEATHERMATE TM FLASHING GREAT STUFF PRO TM GAPS & CRACKS FACE MOUNTED / PENETRATING ANCHOR (4) REQUIRES ADDTIONAL FLASHING / SEALANT (NOT PREFERRED) ANCHOR GUIDELINES ON STUD TWS-M002 COLOR FOR VISUAL CLARIFICATION ONLY LIQUIDARMOR OR WEATHERMATE FLASHING 1. GENERAL FASTENING PATTERN IS 16" O.C. VERTICALLY & HORIZONTALLY UNLESS SPECIFIED DIFFERENTLY BY LICENSED ENGINEER. 2. APPROVED ANCHORS MUST INCLUDE WASHER. 3. WHERE ANCHOR USES MIN. 2" DIA. WASHER, ANCHOR MAY BE USED TO REPLACE 1 INSULATION FASTENER AT THAT LOCATION. 4. ALL PENETRATING ANCHORS MUST BE INSTALLED THROUGH LIQUIDARMOR OR WEATHERMATE FLASHING WITH MIN. WIDTH BASED ON DETAIL TWS-G005. 5. MUST SEAL VOIDS AROUND ALL SHEAR / PLATE ANCHORS WITH GREAT STUFF PRO INSULATING FOAM SEALANT OR OTHER APPROVED SEALANT AND FLASH USING LIQUIDARMOR FLASHING. 2

Anchor Guidelines on CMU HORIZONTAL LADDER REINFORCING (16"O.C. VERTICALLY) PINTEL HOOK TM CAVITY CUT (16"X96") CMU BLOCK SEE FIGURE 1 HORIZONTAL LADDER REINFORCING (16"O.C. VERTICALLY) FIGURE 1 PINTEL HOOK LIQUIDARMOR TM FLASHING GREAT STUFF PRO TM GAPS & CRACKS (CAVITY CUT AT 16"X96") ANCHOR GUIDELINES ON CMU TWS-M003 COLOR FOR VISUAL CLARIFICATION ONLY 1. THERMAX TM BRAND INSULATION BOARDS TO BE CUT AT 16" O.C. WITH A SQUARE EDGE (NOT SHIP LAPPED). 2. JOINTS AT BOARD PERIMTER TO BE FILLED WITH GREAT STUFF PRO GAPS & CRACKS INSULATING FOAM SEALANT OR OTHER APPROVED SEALANT PRIOR TO INSTALLATION OF LIQUIDARMOR. 3. GREAT STUFF PRO GAPS & CRACKS MUST TACK OVER (10-15 MIN.) PRIOR TO INSTALLATION OF LIQUIDARMOR FLASHING. 4. WEATHERMATE FLASHING OR OTHER SELF ADHERED FLASHING MATERIALS ARE NOT ACCEPTABLE FOR THIS APPLICATION DUE TO THE DIFFICULTY IN CREATING A PROPER SEAL AROUND WIRE TIES. 5. LIQUIDARMOR FLASHING CAN SPAN A MAX. 1/4" GAPS - ALL AREAS WHERE JOINTS BETWEEN THERMAX BOARDS EXCEED 1/4" REQUIRE GREAT STUFF PRO GAPS & CRACKS OR OTHER APPROVED SEALANT TO BE INSTALLED. 6. GREAT STUFF PRO GAPS & CRACKS MAY BE LEFT EXPOSED FOR 60 DAYS MAX. 7. LIQUIDARMOR FLASHING MAY BE LEFT EXPOSED FOR A MAX. OF 6 MONTHS OR 180 DAYS. 8. GREAT STUFF PRO GAPS & CRACKS MAY ALSO BE USED TO ADHERE INSULATION BOARDS TO CMU SUBSTRATE. 3

Foundation TM MORTAR NET WEEP VENT WEATHERMATE TM FLASHING METAL THRU-WALL FLASHING STYROFOAM TM XPS (6) METAL STRAPPING (1) STYROFOAM TM BRAND CM SERIES SPRAY POLYURETHANE FOAM FOUNDATION FINISHED GRADE FOUNDATION BRICK AT GRADE TWS-M004.1 COLOR FOR VISUAL CLARIFICATION ONLY 5/8" TYPE "X" GYPSUM SHEATHING LIQDUIDARMOR TM OR WEATHERMATE FLASHING (4) TERMINATION BAR FASTENED @ 8" O.C. T0 METAL STRAPPING (1) THERMAX XARMOR (CI) (5) METAL STRAPPING (1) STYROFOAM CM SERIES SPF STYROFOAM BRAND SILL SEAL FOAM GASKET SELF-ADHERED THRU-WALL FLASHING (2) WITH METAL DRIP EDGE FINISHED GRADE WATERPROOFING STYROFOAM XPS (6) WEEP VENT GROUTED SOLID FOUNDATION PARTIAL BELOW GRADE - GROUTED SOLID TWS-M004.2 COLOR FOR VISUAL CLARIFICATION ONLY 1. MIN. 3" WIDTH OF LIGHT GAUGE METAL STRAPPING, MIN. 16" O.C. ABOVE GRADE, TO ACT AS NAILING BASE FOR TERMINATION BAR. 2. THRU-WALL FLASHING MIN. 40 MIL THICK, MIN 90 DAY UV RESISTANCE, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS USING EDGING TOOL OR ROLLER (HAND APPLIED PRESSURE NOT ACCEPTABLE). WEATHERMATE FLASHING AND LIQUIDARMOR NOT ACCEPTABLE FOR THIS APPLICATION. 3. MIN. WIDTHS OF LIQUIDARMOR AND WEATHERMATE FLASHINGS APPLIED BASED ON DETAIL TWS-G005. 4. THERMAX TM BRAND INSULATION NOT INTENDED FOR USE BELOW GRADE. 5. MIN. 25 PSI STYROFOAM TYPE IV (PER ASTM C578) EXTRUDED POLYSTYRENE (XPS) TO BE USED WHEN INSULATING BELOW GRADE. 6. SEE THERMAX WALL SYSTEM GENERAL DETAIL SET ("TWS-G") FOR OTHER FOUNDATION OPTIONS AND REQUIREMENTS. 4

Windows - Brick Return DESIGN INTENT 1. USE WEATHERMATE TM OR LIQUIDARMOR TM FLASHING TO TRANSITION THE AIR & WATER RESISTIVE BARRIER FROM THE FACE OF THE THERMAX TM INSULATION INTO ALL JAMBS, SILLS, & WINDOW HEADS PRIOR TO INSTALLATION OF PUNCH WINDOWS & WINDOW RECEPTORS. 2. SEALANTS AND CAULKS AS SPECIFIED BY WINDOW MANUFACTURER TO BE USED AS PRIMARY DEFENSE AGAINST MOISTURE INTRUSION & AIR INFILTRATION. 3. WINDOW RECEPTOR TO ATTACH TO WOOD BLOCKING THROUGH DOW FLASHING MEMBRANES FOR ENHANCED AIR AND MOISTURE SEALING. GENERAL RECOMMENDATIONS 1. WINDOW SEALANT COMPATABILITY SHOULD BE VERIFIED BY DOW FOR LONG-TERM ADHESION TO DOW FLASHING. 2. DOW CORNING BUILDING SEALANTS ARE COMPATIBLE WITH DOW FLASHING MATERIALS AND SHOULD BE USED AS PER MANUFACTURER'S & INSTALLATION INSTRUCTIONS. 3. WOOD BLOCKING IS PREFERRED TO PROVIDE ADDED RIGIDITY AND A NAILING BASE AT JAMBS, SILLS, & HEADS. 4. A DOUBLE STUD IS RECOMMENDED ATJAMBS TO ALLOW FOR GREATER FLEXIBILITY WITH CLADDING TERMINATIONS AROUND WINDOWS & DOORS. LIQUIDARMOR TM OR WEATHERMATE TM FLASHING TM SELF-ADHERED THRU WALL FLASHING MORTAR NET WOOD BLOCKING LIDUIDARMOR OR WEATHERMATE FLASHING GREAT STUFF PRO TM GAPS & CRACKS WOOD BLOCKING LIQUIDARMOR OR WEATHERMATE FLASHING STYROFOAM TM BRAND CM SERIES SPRAY POLYURETHANE FOAM PRECAST LINTEL BACKERROD & SEALANT WINDOW HEAD SECTION TWS-M005.1 COLOR FOR VISUAL CLARIFICATION ONLY BRICK FACE RETURN AT WINDOW JAMB PLAN TWS-M005.2 COLOR FOR VISUAL CLARIFICATION ONLY LIQUIDARMOR OR WEATHERMATE FLASHING PRECAST SILL SELF ADHERED THRU-WALL FLASHING WOOD BLOCKING STYROFOAM CM SERIES SPF FLASHING SUPPORT PRECAST WINDOW SILL SECTION TWS-M005.3 COLOR FOR VISUAL CLARIFICATION ONLY 1. DOW FLASHING TO BE INSTALLED ONTO FACE OF THERMAX BASED ON WIDTH REQUIREMENTS ON DETAIL TWS-G005 AND INTO ROUGH OPENING (SILL, JAMB, & HEADER) MIN. 2" OR 1" PAST INTERIOR CAULK JOINT, WHICHEVER IS GREATER. 2. IF NOT USING WOOD BLOCKING AT WINDOW JAMB, HEAD, SILL, (AND RAW EDGE OF THERMAX IS LEFT EXPOSED), MUST USE WEATHERMATE FLASHING (NOT LIQUIDARMOR) TO BRIDGE INSULATION CORE (RAW EDGE). 3. FOR WIDTHS REQUIRING MULTIPLE WYTHES OF WEATHERMATE FLASHING, PIECES SHOULD BE INSTALLED IN A SHINGLE-LAP FASHION TO PROMOTE WATER SHEDDING WITH MIN. 2" ADHERENCE BETWEEN EACH PIECE. 4. SEE THERMAX WALL SYSTEM GENERAL DETAIL SET ("TWS-G") FOR OTHER WINDOW OPTIONS & REQUIREMENTS. 5

Edge of Slab LIQUIDARMOR TM OR WEATHERMATE TM FLASHING STYROFOAM TM BRAND CM SERIES SPRAY POLYURETHANE FOAM SELF-ADHERED THRU-WALL FLASHING WITH METAL DRIP EDGE WEEP VENT RELIEF ANGLE MORTAR NET LIQUIDARMOR OR WEATHERMATE FLASHING TM THERMAL BARRIER EDGE OF SLAB - FACE FLASHED TWS-M006.1 COLOR FOR VISUAL CLARIFICATION ONLY BARREL FASTENER STYROFOAM CM SERIES SPF THRU-WALL FLASHING MECHANICALLY ATTACHED TO SUBSTRATE MORTAR NET WEEP VENT RELIEF ANGLE WEATHERMATE FLASHING LIQUIDARMOR OR WEATHERMATE FLASHING EDGE OF SLAB - FLASHED AT SLAB TWS-M006.2 COLOR FOR VISUAL CLARIFICATION ONLY 1. WEATHERMATE FLASHING TO ENCAPSULATE BOTTOM EDGE OF THERMAX TM BRAND INSULATION WITH MIN. APPLICATION WIDTH ON EACH FACE OF INSULATION BASED ON TWS-G005. 2. WHERE THERMAX COUNTERFLASHES THRU-WALL FLASHING, SELF ADHERED MEMBRANES ARE ONLY ACCEPTABLE IF SLAB PROVIDES SUFFICIENT SUBSTRATE TO BE INSTALLED ON - ALL OTHER APPLICATIONS WILL REQUIRE METAL THRU-WALL FLASHINGS. 3. INSULATION SHOULD BE FLASHED TO BOTTOM EDGE OF RELIEF ANGLES TO PREVENT MOISTURE INTRUSION. 4. IF THRU-WALL FLASHING INSTALLED ON FACE OF THERMAX, LIQUIDARMOR OR WEATHERMATE FLASHING MUST COUNTER FLASH LEADING EDGE OF THRU-WALL FLASHING. 5. SEE THERMAX WALL SYSTEM GENERAL DETAIL SET ("TWS-G") FOR OTHER EDGE OF SLAB OPTIONS & REQUIREMENTS. 6

NOTICE: No freedom from any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer s use and for ensuring that Customer s workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use in all countries or regions. Dow assumes no obligation or liability for the information in this document. References to Dow or the Company mean the Dow legal entity selling the products to Customer unless otherwise expressly noted. NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DOW. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Illustrations are not intended to replace the need for design by appropriate professionals such as architects or engineers. STYROFOAM Brand Spray Polyurethane Foam contains isocyanate, hydrofluorocarbon blowing agent and polyol. Read the instructions and (Material) Safety Data Sheet ((M)SDS) carefully before use. Wear protective clothing (including long sleeves), gloves, goggles and proper respiratory protection. Supplied air or an approved air-purifying respirator equipped with an organic vapor sorbent and a P100 particulate filter is required to maintain exposure levels below ACGIH, OSHA, WEEL or other applicable limits. Provide adequate ventilation. Contents under pressure. STYROFOAM Brand SPF should be installed by a trained SPF applicator. CAUTION: When cured, these products are combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240ºF (116ºC). For more information, consult (Material) Safety Data Sheet ((M)SDS), call Dow at 1-866-583- BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada. GREAT STUFF PRO Insulating Foam sealant and adhesive products contain isocyanate and a flammable blowing agent. Read all instructions and (Material) Safety Data Sheet ((M)SDS), carefully before use. Eliminate all sources of ignition before use. Cover all skin. Wear long sleeves, gloves, and safety glasses or goggles. Not for use in aviation, or food/beverage contact, or as structural support in marine applications. Provide adequate ventilation or wear proper respiratory protection. Contents under pressure. Not to be used for filling closed cavities or voids such as behind walls and under tub surrounds. CAUTION: When cured, these products are combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240ºF (116ºC). For more information, consult (Material) Safety Data Sheet ((M)SDS), call Dow at 1-866-583- BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada. Dow Polyurethane Foam Insulation and Sealant CAUTION: When cured, these products are combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240ºF (116ºC). For more information, consult (Material) Safety Data Sheet ((M)SDS), call Dow at 1-866-583- BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada. CAUTION: This product is combustible and shall only be used as specified by the local building code with respect to flame spread classification and to the use of a suitable thermal barrier. For more information, consult (Material) Safety Data Sheet ((M)SDS), call Dow at 1-866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada. LIQUIDARMOR TM Read the instructions and (Material) Safety Data Sheets ((M)SDS) carefully before use. It is recommended that spray applicators and those working in the spray area wear eye protection. Contact with exposed skin may cause skin discoloration and dryness. Gloves are recommended for prolonged exposures. Ensure adequate ventilation during spray applications. THERMAX TM Brand Polyisocyanurate Insulation CAUTION: This product is combustible and shall only be used as specified by the local building code with respect to flame spread classification and to the use of a suitable thermal barrier. For more information, consult (Material) Safety Data Sheet ((M)SDS), call Dow at 1-866-583-BLUE (2583), or contact your local building inspector. In an emergency, call 1-989-636-4400. STYROFOAM TM Extruded Polystyrene Foam Insulation CAUTION: This product is combustible. Protect from high heat sources. A protective barrier or thermal barrier may be required as specified in the appropriate building code. For more information, consult (Material) Safety Data Sheet ((M)SDS), call Dow at 1-866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada. WARNING: Rigid foam insulation does not constitute a working walkable surface or qualify as a fall protection product. Building and/or construction practices unrelated to building materials could greatly affect moisture and the potential for mold formation. No material supplier including Dow can give assurance that mold will not develop in any specific system. References to DOW or the Company mean The Dow Chemical Company and its consolidated subsidiaries unless otherwise expressly noted. Trademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 179-00283-1116