D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

Similar documents
A 2" MICHIGAN DEPARTMENT OF TRANSPORTATION. 1" (Min.) \ Bracket to \ bottom chord. 24-3" (Max.) 45 (Typ.) * W40 x 149. or l5 x 5 x 1/2 (see

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

Section 716. SHOP CLEANING AND COATING STRUCTURAL STEEL

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

Interior Hangers. Application

Item 442 Metal for Structures

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

SIGN SUPPORT SPECIAL DETAILS

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SECTION COLD-FORMED METAL TRUSSES

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

CITY OF FARGO SPECIFICATIONS SIGNING

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

STRUCTURAL STEEL FRAMING

B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION TIMBER FLOATS

GENERAL ISOMETRIC LAYOUT

CITY OF FARGO SPECIFICATIONS SIGNING

SECTION 716 SIGN MATERIALS SCOPE

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MODULAR EXPANSION JOINT SYSTEM. CFS:JSW 1 of 8 APPR:EMB:DBP: FHWA:APPR:

SECTION MISCELLANEOUS METALS

ITEM 442 METAL FOR STRUCTURES

.2 Section Waste Management and Disposal.

METALS Commissioning of Metals Structural Steel Framing Steel Studs... 2

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

SECTION STRUCTURAL STEEL FRAMING

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.

SECTION METAL STAIRS

FitTech UP171F ELLIPTICAL (FOOTING) UP171I ELLIPTICAL (IN GROUND) UP171S ELLIPTICAL (SURFACE) Parts List

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION

SECTION HANGERS AND SUPPORTS FOR PLUMBING

B. Shop Drawings: Include plans, elevations, sections, details, and attachments.

Smarter. Safer. Leaner.

A. American Society for Testing and Materials (ASTM):

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR BRIDGE DECKS, APPROACHES, RAILS AND PARAPETS PROJECT NUMBER, JP NO.

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

SECTION ORNAMENTAL ALUMINUM FENCING

STANDARD PLAN SYMBOLS & STANDARD LEGEND

SECTION STRUCTURAL METAL FRAMING

Special Provision No. 915S03 December References, Materials, Construction, and Quality Assurance for Sign Support Structures

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Contents EN :2008+A1:2011 (E) Page

Code Compliance Research Report CCRR-0238

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PREFABRICATED STEEL PEDESTRIAN BRIDGE, TYPE 2

Section 906. STRUCTURAL STEEL

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION METAL STAIRS

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PREFABRICATED STEEL PEDESTRIAN BRIDGE, TYPE 2

FitTech UP166F CHEST PRESS (FOOTING) UP166I CHEST PREES (IN GROUND) UP166S CHEST PRESS (SURFACE)

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION 2 DIVISION 05 METALS

P.P.C.C. BRIDGE OVER

SECTION ARCHITECTURAL PRECAST CONCRETE. C. Section Joint Sealers: Perimeter joints with sealant and backing.

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PREFABRICATED STEEL PEDESTRIAN BRIDGE, TYPE 1

SECTION ALUMINUM HANDRAIL SYSTEMS

Draft. Not yet Approved

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Daytona Beach Pier Building Renovation Jun 2010

Code Compliance Research Report CCRR-0238

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER. OPR:CT 1 of 5 APPR:JAR:DBP: FHWA:APPR:

ITEM 442 METALS FOR STRUCTURES

SECTION ORNAMENTAL WELDED STEEL FENCING

SECTION METAL FABRICATIONS

JOB BB0414 PORTER RD. HWY. 112/71B WIDENING & INTCHNG. IMPVTS. (S) AUGUST 10, 2016

SECTION STEEL JOIST FRAMING

Student Services & Classroom Addition

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

MATERIAL SPECIFICATION FOR DECK JOINT ASSEMBLIES

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

SECTION PLATE CONNECTED WOOD TRUSSES

DIVISION 5 METALS SECTION STRUCTURAL STEEL

SECTION STRUCTURAL STEEL

PROJECT: 4/30/14 DATE: REVISIONS: 6/10/14 7/28/14 11/3/14 11/12/14 11/14/14 OF 6

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

Provide heavy hex nuts for the temporary hanger rods according to ASTM A 563 Class 10S, and washers according to ASTM F 436.

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

SECTION PIPE AND TUBE RAILINGS

SECTION STRUCTURAL STEEL

Section 713. BRIDGE REHABILITATION STEEL

SECTOR GATE PAINTING AND STEEL REPAIRS DRAWING NO. NEW BEDFORD-FAIRHAVEN BARRIER M ASSACHUSETTS W 912W J18B0007 SOLICITATION NO.: CONTRACT NO.

Code Compliance Research Report CCRR-0187

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Installation and Maintenance Manual for EMH Freestanding Workstation Jib Cranes

Transcription:

Sign length minus Adjust to avoid interference with sign legend A Deck fascia A 6" Equal Equal 6" Sign length (L) varies 6 to 12 PLAN 0 CONNECTION (DECK FASCIA) Angle connection assembly F Face of concrete I-beam Beam \ E bottom flange 3 1/ B Anchor spacing - see sheet 4 of 11 for length E C D D WT9 x 17.5 L4" x 4" x 3/8" Brace Deck fascia C8 x 4.25 Strut (aluminum) 1 Detail B O L4" x 4" x 3/8" Brace Detail C Bent > 7" x 8" x 3/8" (aluminum) 5/8"! stainless bolt, (2) flat washers, & nylon insert lock nut ** B C 1" Sign length minus 1" Sign length (L) varies 6 to 12 PLAN 5-40 CONNECTION (CONCRETE I-BEAM OPTION SHOWN) BRIDGE CONNECTION - TYPE A1 F DEPARTMENT DIRECTOR Kirk T. Steudle FOR Michigan Department of Transportation PREPARED BY DESIGN DIVISION APPROVED BY: DIRECTOR, BUREAU OF FIELD SERVICES BRIDGE SIGN CONNECTION TYPE A1, A2 & B DRAWN BY: CHECKED BY: DHD AJU APPROVED BY: DIRECTOR, BUREAU OF HIGHWAY DEVELOPMENT 1 OF 12

Drill 9/16"! holes in angle for 1/! stainless steel Deck overhang varies adhesive anchor bolt (4) required * Connect brace to 1-0" 4 1/ Min Angle connection assembly *This brace configuration may only be used with barrier type bridge railing L4" x 4" x 3/8" Brace (Eliminate when strut either beam or length is less than 2-6") barrier, but not both. Strut length C8 x 4.25 Strut (aluminum) Angle connection assembly WT9 X 17.5 Sign height (H) 2-6" Max Bent > 7" x 8" x Bridge beam (type varies) 3/8" (aluminum) A L4"x 4"x 3/8" Brace (eliminate when strut length is less than 2-6") * This is an alternative brace configuration for concrete I-beams SECTION F-F 5-40 CONNECTION (CONNECTION TO CONCRETE BEAM OPTION) Steel bridge beam 5/8"! galv. high strength bolt. (4) required per WT ** 6" L4" x 4" x 3/8" Brace (eliminate when strut length is less than 2-6") Angle connection assembly This is an alternative brace configuration for steel I-beams SECTION F-F 5-40 CONNECTION (CONNECTION TO STEEL BEAM OPTION TO BE USED WHEN NO BRIDGE BARRIER RAILING IS PRESENT) BRIDGE CONNECTION - TYPE A1 NOTES: Angle connection assembly is the same for connections to barrier, concrete I-beams and steel beams. section D-D and E-E for other details. 2 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

6 3/4" Min 1/ Gap Reg. washer Top of deck 10" Min 5" Min 5" Min Deck fascia Drill 13/16"! hole in channel for 3/4"! adhesive Nylon insert lock nut Nylon washer anchor bolt with extra thread, (2) flat washers, & nylon insert lock nut SECTION A-A NOTE: Typical for all sign connections. WT9 X 17.5 Drill 9/16"! hole in WT9 x 17.5 for 1/! stainless steel adhesive anchor 3/16" bolt (4) required per WT Top of deck Drill 9/16"! hole for 1/! stainless bolt, (2) flat washers & nylon insert lock nut. (3) required 7 x 8 x 3/8" Bent > 2 1/ 1 3/4" 3 1/ 4 1/ 4 1/ 1 1 7" 2 3/4" Min 2 3/4" Min 10" Min (aluminum) place 1/8" elastomeric (or Min Deck fascia equivalent) pad to cover entire surface area 5/8"! stainless bolt, (2) flat between steel and aluminum washers, & nylon insert lock nut. (2) required ** sections SECTION B-B L4" x 4" x 3/8" Brace WT5 x 9.5 Drill 9/16"! holes in angle for 1/! stainless steel adhesive anchor bolt L 4" x 4" x 3/8" x 1-6" Long Angle connection assembly 1 1/ 5" 5" 5" 1 1/ 1-6" SECTION D-D BRIDGE CONNECTION - TYPE A1 3 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

5/8"! 4 1/ Min Top of deck 3" stainless bolt, (2) flat washers, & nylon insert lock nut. (2) required ** C8 x 4.25 Strut (aluminum) length varies 7" x 8" x 3/8" Bent > 1 2 1/ Optional instead of the 2 bolts 1 1/ 10" Min. 2 3/4" 2 3/4" Min. Min. 7" 4 1/ 1 3 1/ 3 1/ 1 1/ 8" 1" Drill 9/16"! hole in wt for 1/! stainless steel adhesive anchor bolt (4) required per WT WT9 x 17.5 Place 1/8" elastomeric (or equivalent) pad to cover entire surface area between steel and aluminum sections 5/8"! stainless bolt, (2) flat washers, & nylon insert lock nut. (4) required - no welding allowed at this connection ** SECTION C-C L4" x 4" x 3/8" Brace place 1/8" elastomeric (or equivalent) pad to cover entire surface area between steel and aluminum sections Concrete I-beam 1 1/ NOTE: Brace may be eliminated for strut lengths less than 2-6". L4" x 4" x 3/8" x 1-6" Long Flange Dimensions E 3 3/8" Max. embed A B L4" x 4" x 3/8" Brace WT5 X 9.5 Brestressed I-beam depth 28" (Type I) 36" (Type II) 45" (Type III) 54" (Type IV) A B D E 4" 3 1/16" 2 13/16" 2 13/16" 4" 4 1/ 2 13/16" 2 13/16" 4 1/ 6 1/8" 3 3/16" 3 3/16" 5 1/ 7 3 7/8" 3 7/8" Drill 9/16"! hole in angle for 1/! stainless steel adhesive anchor bolt (4) required D 4 1/ Angle connection assembly 5/8"! high strength bolt, (2) flat washers, & nylon insert lock nut ** SECTION E-E Anchor spacing = (Sign length minus ) x COS O Strut length = (Sign length minus ) x SIN O + 5" * ADHESIVE ANCHOR MINIMUM EFFECTIVE ULTIMATE STRENGTHS INSTALLED IN CONC. BEAM FLANGE INSTALLED IN DECK FASCIA INSTALLED IN T-BEAM/BARRIER Tension (lbs) Shear (lbs) Tension (lbs) Shear (lbs) Tension (lbs) Shear (lbs) 1275 825 5470 315 15500 9200 A1 Connection A2 Connection * Effective ultimate strength is equal to the ultimate strength modified by the appropriate edge distance and anchor spacing reduction factors recommended by the manufacturer. BRIDGE CONNECTION - TYPE A1 4 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

Face of H concrete L7 X 4 X 3/8" H L7" X 4" X 3/8" H G G G B H G Eliminate middle arm for L less than or equal to 8-0" WT9 X 17.5 I Detail D J Detail B B I J Detail C L/2 L/2 Sign length (L) (varies 6-0" to 12-0") PLAN 5-40 CONNECTION (CONCRETE T-BEAMS & CONCRETE BARRIERS) L7" X 4" X 3/8" 1 7/8" 2 1/8" 4 1/ 13/16"! Holes in angle for adhesive anchor 6 3/4" 6" 6" 2 1/8" 1 7/8" 3/4"! stainless steel bolt SECTION G-G BRIDGE CONNECTION - TYPE A2 5 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

6" Min. 6 3/4" Min. L7" x 4" x 3/8" Deck overhang Varies 4 1/ 1/4 11" Min. 13/16"! Holes in angle for adhesive anchor 3/4 "! stainless steel bolt SECTION H-H (AT CONCRETE T-BEAM BRIDGES) 6 3/4" Min. L7" x 4" x 3/8" Bottom of barrier 4 1/ 6" 13/16"! Holes in angle for adhesive anchor 3/4"! stainless steel bolt SECTION H-H (AT CONCRETE BARRIER RAILING TYPE 4, TYPE 5 OR AESTHETIC PARAPET TUBE RAILING) NOTE: chart on sheet 4 for adhesive anchor strengths. BRIDGE CONNECTION - TYPE A2 6 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

5/8"! stainless bolt, (2) flat washers, & nylon insert lock nut. (2) required ** 1" 4" 4" 1 x 4" x 3/8" > 4" SECTION I-I NOTE: Place 1/8" elastomeric (or equivalent) pad to cover the entire surface area between steel and aluminum surfaces. Bent > 7" x 8" x 3/8" 1 1/ 2 1 1/ 2 3 1/ 5/8"! stainless bolt, (2) flat washers, & nylon insert lock nut. (2) required ** 3/16" SECTION J-J BRIDGE CONNECTION - TYPE A2 7 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

Adjust to avoid interference with Detail A Sign length minus K sign legend Steel girder web L3 1/ x 3 1/ x 3/8" x 7" Long > 7" x 9" x 3/8" K 6" Equal Equal 6" Sign length (L) varies 6 to 12 PLAN 0 CONNECTION Steel girder web 3 1/ L Anchor spacing - sheet 4 of 11 for length M WT9 x 17.5 C8 x 4.25 Strut (aluminum) 1 Detail B O Detail C Bent > 7" x 8" x 3/8" (aluminum) 5/8"! stainless bolt, (2) flatwashers, & nylon insert lock nut ** L M 1" Sign length minus 1" Sign length (L) varies 6 to 12 PLAN 5-40 CONNECTION (STEEL BEAM) BRIDGE CONNECTION - TYPE B 8 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

5/8"! galv. high strength bolt. (4) required per WT ** 3/16" 5/8"! stainless bolt, (2) flat washers and nylon insert lock nut (2) required ** 3/16" WT9 x 17.5 1 3/16" 9" 7 x 9 x 3/8" > Drill 9/16"! hole for 1/! stainless bolt, (2) flat 1 7" 1 4 1/ washers & nylon insert lock nut. (3) required Drill 9/16"! hole for 1/! stainless bolt, (2) flat washers & nylon insert lock nut. 2 1/ 3 1/ 1 4 1/ 7" L3 1/ x 3 1/ x 3/8" (3) required 7" x 8" x 3/8" Bent > (aluminum) 5/8"! stainless bolt, (2) flatwashers, & nylon insert lock nut. 5/8"! galv. high (2) required ** strength bolt. (4) required per WT ** SECTION K-K SECTION L-L NOTE: Place 1/8" elastomeric (or equivalent) pad to cover the entire surface area between steel and aluminum surfaces. 3" C8 x 4.25 Strut (aluminum) length varies 7" x 8" x 3/8" Bent > (aluminum) Optional instead 7" 1 4 1/ 1 2 1/ of the 2 bolts 1 1/ 3 1/ 3 1/ 5/8"! stainless bolt, (2) 1" Sign height (H) 2-6" Max. 5/8"! galv. high strength bolt. WT9 X 17.5 flatwashers, & nylon insert lock nut (2) required ** (4) required per WT ** 5/8"! stainless bolt, (2) flatwashers, & nylon insert lock nut (6) required ** SECTION M-M BRIDGE CONNECTION - TYPE B 9 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

Lock Nut 5.5 3 threads beyond nut Steel w/ alum. column Flat washer 5.5 5/8" Dia. h.s. bolt 5.5 1/8" Elastomeric or equivalent pad to cover entire surface 5/8"! stainless bolt ** Flat washer 5.5 area between steel and aluminum sections. 5/8"! galv. high- strength bolt ** ** BOLT DETAIL L3 1/ x 3 1/ x 3/8" x 7" Long Place 1/8" elastomeric (or equivalent) pad to cover entire surface area between > 7" x 9" x 3/8" steel and aluminum sections 5/8"! stainless bolt ** Place 1/8" elastomeric O (or equivalent) pad to cover entire surface area between steel and DETAIL A Sign face Stem of WT aluminum sections 2 1/ R 1 4" 4" O Strut Bent > 7" x 8" x 3/8" (aluminum) Sign DETAIL B face 2 1/ 5/8"! stainless R 1 bolt ** 4" 4" Bent > 7" x 8" x 3/8" (aluminum) 4" Sign DETAIL C face 5/8"! stainless bolt ** 1 x 4" x 3/8" > 90 - O Sign face Adjust to avoid interference with sign legend and aluminum plate DETAIL D 10 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

NOTES: 1. Field verify bridge dimensions prior to fabrication. 2. Welding shall be in accordance with the current Standard Specifications for Construction. 3. All structural steel members shall be hot-dip galvanized in accordance with the current Standard Specifications for Construction. 4. All aluminum members shall be ASTM B 308 aluminum alloy 6061-T6 and shall conform to ASTM B 221. Aluminum plates must be ASTM B 308 aluminum alloy 6061-T6 and must be according to ASTM B 209. All plates must be free of sharp edges and irregularities. 5. Structural steel members shall conform to AASHTO M 270 grade 36. 6. All high-strength bolts, nuts and washers shall be in accordance with subsection 906.07 and installed according to subsection 707.03.D.7 of the current MDOT Standard Specifications for Construction except for stainless steel bolts, nuts and washers. 7. Stainless steel bolts and washers shall conform to ASTM A 320, class 1, grade B8. Nuts shall be self-locking nylon insert type and must conform to ASTM A 320, grade 8F. Stainless steel nuts and washers shall always accompany stainless steel bolts. Stainless steel bolts, nuts and washers shall be used at connections with aluminum members. All other connections shall utilize galvanized high strength bolts, nuts and washers unless otherwise specified. 8. O = Angle between sign and bridge. 9. All concrete anchors shall be chosen from the qualified product list in the current MDOT Materials Source Guide. All concrete anchors shall be installed according to the manufacturers recommendations and subject to the requirements of section 712.03.J of the the current MDOT Standard Specifications for Construction except that all field testing must demonstrate the anchor can develop 70 percent of the minimum effective ultimate strength shown in the plans with less than 1/16 inch slip. Field testing up to 90 percent of the bolts yield strength is waived. Extreme caution shall be exercised when drilling holes for concrete anchors. Existing bridge plans shall be reviewed to determine the prestressing strand locations and to evaluate the risk of damaging prestressing strands associated with installing concrete anchors. 10. The bottom edge of the sign shall be horizontal when erected. 11. If replacing an existing sign support, unused holes in steel bridge beams shall be filled with a galvanized high strength bolt installed according to subsection 707.03.D.7 of the current MDOT Standard Specifications for Construction. Existing holes in concrete shall not be reused and shall be filled with a non-shrink grout in accordance with section 702.02.B of the the current MDOT Standard Specifications for Construction. 12. Sign support connection shall be installed on one bridge span of a bridge structure and shifted to avoid conflict with joints or stiffeners. 13. For connections on ASTM A 588 weathering steel bridges, the connection interface shall be blast cleaned and primed with organic zinc-rich paint in accordance with section 715 of the current MDOT Standard Specifications for Construction. If the existing bridge beam is unpainted ASTM A 588 weathering steel, the paint color shall be "brown weathering steel", federal code number 10062 and the paint shall overlap the perimeter of the connection by 2 inches, otherwise blend the paint to match existing paint color. the perimeter of the connections to the bridge beam web shall be sealed with an approved silicone sealant in accordance with subsection 713.03.F of the current MDOT Standard Specifications for Construction. The bolted connections to the bridge beam web shall be according to subsection 707.03.D.7 of the current MDOT Standard Specifications for Construction and shall utilize high strength bolts conforming to ASTM A 325 type 3. 14. Bridges built before 1978 contain lead based paint unless repainted after 1978. 15. Inspection of proposed locations shall be performed to determine viability of connection to existing bridge. 11 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.

NOTES (Continued): 16. These sign support connections shall be used with Type II or Type III signs. 17. subsection 810.03.P of the the current MDOT Standard Specifications for Construction for bolt replacement in retained bridge mounted sign connections. 18. Removal of existing bridge sign connections shall be according to subsection 810.03.T of the current MDOT Standard Specifications for Construction. 19. sections 712, 713 and 715 of the the current MDOT Standard Specifications for Construction for bridge sign connections to existing bridges. 20. Aluminum member designations are in accordance with the aluminum association aluminum design manual, 2000 edition. Aluminum channels are american standard series channels (C depth X weight). 21. All members are steel unless otherwise noted. 22. The design of this bridge sign connection is according to the AASHTO Standard Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals, current Edition. 23. Type A1 denotes connections to concrete I-beam, steel I-beam bridges, bridge or barrier railing Type 4 or Type 5.Type A2 denotes connections to concrete T-beam bridges and connections to bridge barrier railing Type 4, Type 5 and aesthetic parapet tube railing. Type B denotes connections to steel. 24. For new bridges, surface rustication (texturing) at sign connections to railing shall be eliminated behind signs. For existing bridges, surface rustication (texturing) at sign connections to concrete shall be removed to a smooth surface. Care shall be taken to not remove excessive concrete below the depth of the texturing. 12 OF 12 NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE.