Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

Similar documents
Fastener Guidelines. Issued: 2015 Technical Communication - Fastener Guidelines DESIGN BASIS

Insulation Fastener Guide IKO Ener-Air & IKO Enerfoil Wall Insulation

Construction Standards PAGE

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

GAF EnergyGuard Polyiso Wall Sheathing

INSTALLATION GUIDE EPS FOAM

1. Building insulation in batt form. 2. Rigid board insulation. 3. Cavity wall insulation.

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

California Building Envelope Solutions

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

R-Matte Plus-3: Insulation for the Building Envelope

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

RainBarrier Installation Guide

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance

SECTION PRE-ENGINEERED BUILDING INSULATION

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Henry NFPA 285 Air Barrier Assemblies

NFPA 285 Assemblies. Table of Contents

NFPA 285 Assemblies. Table of Contents

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

SECTION THERMAL INSULATION

Residential Product Selector Guide

Impact of NFPA 285 on Air Barrier Specification and Design

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

Insulation Systems Submittal Form

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide

Gold Bond BRAND Gypsum Sheathing

Building Insulation Submittal Form

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

SECTION INSULATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Thermal Control Layers: Insulation Materials and Systems

A. Source Limitations: Obtain each type of building insulation through one source.

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Ultra Wall System. CAD Detail Sets

UL Design System HW-D-1012 continued

Originally Issued: 07/31/2015 Revised: 07/31/2017 Valid Through: 07/31/ General

UNITED STATES COMMERCIAL + RESIDENTIAL Building Insulation Guide

Duct Wrap Flexible Wraps

An Introduction to Spray Foam Insulation

Insulation manufacturer to submit dew point analysis free of charge for typical wall section. Analysis by:

SECTION (07200) - THERMAL PROTECTION

C. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product.

THERMAL INSULATION

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Cladding Attachment Through Exterior Insulation Using Long Screws PHIUS 10 TH ANNUAL NAPHC, CHICAGO COLIN SHANE M.ENG, P.ENG 11 SEPTEMBER 2015

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

FIRE RATING MATERIAL FIXING NOTES

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

Deer Ridge Consulting, Inc.

Originally Issued: 07/06/2009 Revised: 04/07/2017 Valid Through: 07/31/2017

The Role of Control Layers in Building Enclosure Design

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

Rev. 08 9/15 Please Read Disclaimers:

SRP-AirOutshield UV Issued:

Residential. Building Insulation Guide

Cladding Attachment and Support

FIRE STATION 55 June 14, 2010

Thermal Bridging From Cladding Attachment Strategies Through Exterior Insulation

DuPont Tyvek Wall Underlay Install Guide

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

Technical Data Sheet

SECTION CEMENTITIOUS SHEATHING

SECTION THERMAL INSULATION

Zero Energy Ready Home Training

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

Installation Guide. IMPORTANT: Read all sections before starting. For the most up-to-date information, visit our website: leadvisioninternational.

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS

FERO RAP TIE AND FAST SYSTEM THERMAL ANALYSIS

Rain tightness of wind barrier and sealing of window joints Experimental laboratory testing

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

Installation Guidelines

WEIGHT PER PIECE (LBS.)

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

Continuous Insulation Systems for Exterior Walls

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

Perm-A-Barrier VPS (Vapor Permeable Sheet)

KNIGHT WALL SYSTEMS GUIDE DETAILS:

JM SPRAY FOAM: A BETTER PRODUCT FROM A BETTER PARTNER

MATERIALS MATTER. Legendary innovation in every detail of every product. JM SPRAY FOAM: A BETTER PRODUCT FROM A BETTER PARTNER

BUILDING SCIENCE CORPORATION DIGEST OF INSULATED METAL PANELS PERFORMANCE REDEFINED

Thermal Bridging in Building Thermal Envelope Assemblies: Repetitive Metal Penetrations

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

A. ASTM C203: Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS REPORT HOLDER:

CommercialComplete Wall System

(Project Location) (your firm's name)

2013 COMMERCIAL PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

CANADA COMMERCIAL + RESIDENTIAL Building Insulation Guide

Transcription:

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation Johns Manville s MinWool Water & Fire Block mineral wool insulation provides a vapor-permeable continuous layer of insulation. Along with its fire-resistant capabilities, Water & Fire Block will repel water, which allows for its use in rain screen applications. Johns Manville MinWool Water & Fire Block mineral wool insulation can be used in Type I-V construction behind a variety of cladding systems including brick, and concrete, and can be mechanically fastened to wood, steel, and concrete substrates. Typical Assembly Overview 1. and framing structure 2. Cavity Insulation 3. Exterior structural sheathing (gypsum, wood, or other approved material) 4. Air and water barrier 5. Mineral wool exterior insulation board installed using mechanical fasteners 6. Framing structure Mineral wool exterior insulation board Mechanical fasteners Cavity Insulation Exterior structural sheathing Air and water barrier

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation 2 Recommended Components Cavity insulation: fiber glass batt (JM Formaldehyde-free fiber glass batts: unfaced, faced or ComfortTherm ); spray-in fiber glass (JM Climate Pro blown-in fiber glass, JM Spider Custom Insulation System), spray polyurethane foam (JM Corbond ); mineral wool (JM MinWool ) Mechanical fasteners: screw & washer, insulation fastener, plastic cap nails, or other proprietary fasteners Stick/impaling pins, adhesive for temporary securement Safety Equipment Recommendations Loose-fit long-sleeved shirt and long-legged pants Gloves Safety glasses with side shields Installation Procedure Installation recommendations and procedures can change based on the mechanical fastening requirements of the exterior cladding system or the design of the building structure. Below are general installation guidelines. Installation to Exterior Sheathing Water & Fire Block insulation is installed on top of the air and water barrier. Boards should be butted together with no gaps or voids. If necessary, install stick pins or impaling pins to hold the insulation in place prior to mechanically fastening the insulation to the substrate. Johns Manville s Water & Fire Block may be installed with a variety of mechanical fasteners. Fasteners should be appropriate for the type of substrate, capable of withstanding all applied loads, and suitable for use outside in an exterior application. Mechanical fasteners should be spaced no more than 24 apart and should be installed in a manner as to not overly compress the insulation. The fasteners should be placed no less than 3 from the board edges and should penetrate 1½ into the exterior sheathing. Use a sufficient amount of fasteners to hold the insulation in place without having the product pillow, sag, or tear under expected conditions. Refer to the recommended components section for appropriate mechanical fasteners. 3 16-24 Fastener length = thickness + 1.5

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation 3 Installation with Exterior Cladding Attachment Systems Johns Manville MinWool Water & Fire Block mineral wool insulation is compatible with many types of exterior cladding attachment systems including strapping (wood furring), vertical or horizontal girts, and metal bracket and girt systems. Some common installation procedures are outlined below. 1. Measure spacing to mechanically fasten the cladding attachment system to the studs. This spacing can differ based on the requirements of the exterior cladding, or based on the recommendations of the structural engineer. 2. Install insulation to the exterior sheathing using mechanical fasteners. 3. Install exterior cladding per manufacturer s guidelines as soon as possible. If the insulation will be exposed to the elements prior to the exterior cladding installation, protect it with a waterproof tarpaulin. Strapping If strapping is used to mechanically attach the exterior cladding, install the mineral wool to the sheathing first, then install the straps and exterior cladding. Strapping Furring straps Air and water barrier Insulation

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation 4 Brick Ties When brick is used as the exterior cladding, first install the brick ties per manufacturer s recommendations. Then, install the mineral wool insulation by either putting a hole in the insulation for the brick ties, or fit the insulation around the brick ties. Add additional fasteners as needed. Brick Ties Brick ties through mineral wool Exterior brick cladding

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation 5 Mechanical Attachment Systems In some cases, the exterior cladding will require a mechanical attachment system. The mineral wool should be installed per the cladding system manufacturer s recommendations for continuous insulation. Mechanical Attachment System mechanical attachment stystem Mineral wool insulation Storage Recommendations Store Water & Fire Block elevated above the floor, ground, and/or standing water. If stored outdoors, cover completely with a waterproof tarpaulin. For indoor and outdoor storage, adhere to all local building and fire codes including NFPA 230 and NFPA 13. 11/17 2017 Johns Manville. All Rights Reserved.