STRUCTURAL CALCULATIONS & DETAILS

Similar documents
TWO STOREY MASONRY VENEER DESIGN SOLUTION - FIRTH 10 SERIES HOLLOW MASONRY, MANORSTONE

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address:

TECHNICAL INSTALLATION

POST FRAME BUILDING STANDARDS

SIMPSON STRONG-TIE BOTTOM PLATE ANCHOR SOLUTIONS. Product. Scope. Building Regulations. Appraisal No. 983 [2018] Appraisal No.

HANLON AND PARTNERS LTD Consulting Structural & Fire Engineers. Specification for. Mental Health Acute Inpatient Unit Wakari Hospital, Dunedin

PHASE 1 Foundation & Drainage New Construction Phased Inspection Report John & Mary Doe 5237 Clinton Street, Denver, CO 80238

GUIDELINES FOR RETAINING WALLS 4-0 IN HEIGHT OR LESS

CUBOID GLAZING CHANNEL SYSTEM. Glass Fittings Ltd. MULTIPLE SITES. 02-Mar-17

A White Paper on the NZ Building Code B2 (Durability) Issues, Solutions and where to from here

Memorandum from licensed building practitioner: Certificate of design work Section 45 and section 30c, Building Act 2004

aurecongroup.com

Building consent application Pack 3 Solid fuel heating appliance

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

SPECIFICATION FOR REINFORCED SOIL WALL

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

CITY OF BATAVIA DECK CONSTRUCTION REQUIREMENTS

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

NOTICE XX/2017 SUPPLY AND ERECT PRE-CAST CONCRETE PALISADE FENCING WITHIN THE KOUGA MUNICIPAL AREA

Pulaski County, Virginia

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

Mandatory Wood Frame Soft-story Retrofit Program PERMITTING AND INSPECTION PROCESS GUIDELINES

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

SPECIAL INSPECTION AND TESTING AGREEMENT

Form 2: Application for PIM and/or Building Consent

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Verification Method B1/VM4 Foundations

NZS 4219:2009. New Zealand Standard. Seismic performance of engineering systems in buildings. Superseding NZS 4219:1983 NZS 4219:2009

Evaluation Report CCMC R Superior Walls Xi Precast Concrete Insulated Wall Panels

DECK PERMIT APPLICATION

Determination regarding heart macrocarpa posts and decking to a house at 51 Wastney Terrace, Nelson

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address:

FACT SHEET #2 DECK INFORMATION

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION

CONSTRUCTION SPECIFICATION FOR CONCRETE FOOTINGS AND MAINTENANCE PLATFORMS FOR HIGH MAST LIGHTING POLES

CAPRICORN MUNICIPAL DEVELOPMENT GUIDELINES PRECAST BOX CULVERTS CONSTRUCTION SPECIFICATION

Deck Design Guide. 67 Sharp Road, Brighton, Ontario P.O. Box 189 K0K 1H0 Tel: Fax: Web:

Main Roads Standard Specification

TOWN OF BRADFORD WEST GWILLIMBURY DECK PACKAGE

INSPECTION REQUIREMENTS: FOUNDATIONS

SECTION METAL PLATE CONNECTED WOOD TRUSSES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SYNTHETIC SELF SUPPORT ROOFING UNDERLAY

SPECIAL INSPECTION AGREEMENT

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Technical Memorandum: Road Safety Hardware Series. technical memorandum

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

MAYER STAINLESS STEEL PRESS-FIT PIPING SYSTEM. Product. Scope. Building Regulations. Appraisal No [2018] Appraisal No.

STATEMENT OF SPECIAL INSPECTION FORM

Product Information Bulletin

Residential Deck Guide

******************************************************************************

Tauranga City Council

STANDARD DESIGN NOTES 1 / 2

Procedure to Obtain a Sewage System Building Permit

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

PAULOID SYNTHETIC ROOFING UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 984 [2017] Appraisal No. 984 (2017) BRANZ Appraisals

GARAGE MAIN FLOOR PLAN

Bison Precast Flooring Specification

CHAPTER 13 - MECHANICALLY STABILIZED EARTH WALLS AND PATENTED EARTH RETAINING SYSTEMS

CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

CHRISTCHURCH CITY COUNCIL. Environmental Services Unit. SUBDIVISION BULLETIN NO 7 (6 February 2006)

DECK CONSTRUCTION REQUIREMENTS

Name:.. Signature:.. Date:...

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

DECKS INCLUDED: LIST OF REQUIREMENTS DECK DESIGN MATRIX APPLICATION FORM SAMPLE DRAWINGS

Community Services Dept., City of Mississauga Subdivision Requirements Manual Page 1 of 5 Specifications Revised: September 26, 2005

Residential Decks. NOTE: If you are in a development with a 2. Deck Plan (see below)

ARROWHEAD LAKES HOMEOWNERS' ASSOCIATION REQUEST FOR NEW OR MODIFICATION OF EXISTING DOCK

WATERTIGHT ROOF UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 938 [2017] Appraisal No. 938 (2017) BRANZ Appraisals

Pole Barns. Guides For Homeowners. Why Do I need a Permit? DID YOU KNOW? Charles Abbott Associates. Tips on hiring contractors.


KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

Pole Barns. Why Do I need a Permit? D ID Y OU K N OW? What you need to apply for a building permit: Tips on hiring contractors.

CERTIFICATE OF CONFORMITY This product Certificate is issued under Section 269 of the Building Act 2004 for:

LANDSCAPE RETAINING WALLS

BISON PRECAST FLOORING SPECIFICATION

Stone and Masonry Veneer

User Guide for New and Altered Commercial Buildings

CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.

Campbell County Building Inspection Division Guideline to 2018 IRC Residential Construction for Decks

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice

SECTION STEEL JOIST FRAMING

STRUCTURAL STEEL FRAMING

REGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS

C263 Guide Posts CONSTRUCTION SPECIFICATION FOR DEVELOPMENTS AND SUBDIVISIONS

SPECIFICATION FOR PRECAST/ COMPOSITE CONCRETE FLOORS/ ROOF DECKS SECTION E60

Transcription:

S y n g e C o n s u l t i n g Ltd. S t r u c t u r a l E n g i n e e r i n g STRUCTURAL CALCULATIONS & DETAILS Pole Retaining Wall at 61 Exploration Way Whitby Lot 100 DP 478324 Prepared for: Keys Construction Synge Consulting Ltd 3 Vera St Wellington Project Ref: 1548 04 4764 328 Revision: - 021 519 085 Date 1 December 2015 tony@synge.co.nz

Contents page PS1 & Design Memorandum Structural Details 1 Retaining wall plan SK 1 2 Tied back wall SK 2 3 Cantilever wall SK 3 Specification Calculations Design Standards Structure Loading Standard AS/NZS 1170 Timber Structures Standard NZS 3603:1993 Concrete Structures Standard NZS 3101:2006

ISSUED BY: TO: TO BE SUPPLIED TO: PRODUCER STATEMENT PS1 DESIGN Synge Consulting Ltd (Design Firm) Keys Construction (Owner/Developer) Porirua City Council (Building Consent Authority) IN RESPECT OF: Pole Retaining Wall (Description of Building Work) AT: 61 Exploration Way Whitby (Address) Lot 100 DP 478324 We have been engaged by the owner/developer referred to above to provide.. Specific design of pole retaining Building Code Clause(s) B1 wall services in respect of the requirements of (Extent of Engagement) Clause(s) B1 of the Building Code for All or Part only (as specified in the attachment to this statement), of the proposed building work. The design carried out by us has been prepared in accordance with: Compliance Documents issued by the Ministry of Business, Innovation & Employment B1/VM1, B1/AS1. (verification method / acceptable solution) The proposed building work covered by this producer statement is described on the drawings titled Pole Retaining Wall, 61 Exploration Way, Whitby and numbered 1548 together with the specification, and other documents set out in the schedule attached to this statement. On behalf of the Design Firm, and subject to: (i) Site verification of the following design assumptions Ground ultimate bearing capacity > 300 kpa (ii) All proprietary products meeting their performance I believe on reasonable grounds that a) the building, if constructed in accordance with the drawings, specifications, and other documents provided or listed in the attached schedule, will comply with the relevant provisions of the Building Code and that b), the persons who have undertaken the design have the necessary competency to do so. I also recommend the following level of construction monitoring/observation: CM1 CM2 CM3 CM4 I, A J Synge am CPEng # 62314 (Name of Design Professional) I am a Member of IPENZ and hold the following qualifications: MIPENZ, CPEng, IntPE(NZ) The Design Firm issuing this statement holds a current policy of Professional Indemnity Insurance no less than $200,000*. SIGNED BY: A J Synge ON BEHALF OF: Synge Consulting Ltd (Design Firm) Date: 1 December 2015 (signature) Note: This statement shall only be relied upon by the Building Consent Authority named above. Liability under this statement accrues to the Design Firm only. The total maximum amount of damages payable arising from this statement and all other statements provided to the Building Consent Authority in relation to this building work, whether in contract, tort or otherwise (including negligence), is limited to the sum of $200,000*. This form is to accompany Form 2 of the Building (Forms) Regulations 2004 for the application of a Building Consent. THIS FORM AND ITS CONDITIONS ARE COPYRIGHT TO ACENZ, IPENZ AND NZIA PRODUCER STATEMENT PS1 October 2013

Memorandum from licensed building practitioner of design work Section 30C or section 45, Building Act 2004 The building Street address of building: 61 Exploration Way Whitby The owner Name: Progeni Ltd Address: 61 Exploration Way Whitby Telephone number: Email: Basis for providing this memorandum I am providing this memorandum in my role as the: specialist designer who carried out specific elements of RBW design work as outlined in this memorandum other designers will be providing a memorandum covering the remaining RBW design work Identification of design work that is restricted building work I, A J Synge, carried out or supervised the following design work that is restricted building work: Primary structure Design work that is restricted building work Description Carried out / supervised Reference to plans and specifications Foundations Walls Roof Coulmns and beams Bracing Other Pole retaining wall Roof beams Carried out Supervised Carried out Supervised Carried out Supervised Carried out Supervised Carried out Supervised Carried out Supervised Waivers or Modifications Are waivers or modifications of the building code required? ( ) Yes ( ) No Issued by Name: A J Synge Registration No: 62314 The practitioner is a: Chartered professional engineer Street address or registered office: 3 Vera St, Karori, Wellington, 6012 Phone number: 04 4764 328 Mobile: 021 519 085 Fax: 04 4764 329 Email address: tony@synge.co.nz Declaration I Anthony Synge state that the design work that is restricted building work recorded on this form: (a) complies with the building code; or (b) complies with the building code subject to any waiver or modification of the building code recorded on this form. Signature: Date: 1 December 2015

Synge Consulting Ltd 3 Vera St, Wellington 6012 Page: 04 4764 328 Ref: 1548 Project: 61 Exploration Way Whitby Date: 1-Dec-15 STRUCTURAL DETAILS

Timber Pole Retaining Wall Exploration Way, Whitby 1 TIMBER POLE RETAINING WALL 1.1 Scope STRUCTURAL SPECIFICATION Supply all materials and erect timber pole retaining wall, as shown on the drawings. 1.2 Materials TIMBER POLES Poles shall be radiata pine, selected in accordance with NZS 3602 and treated to H5 in accordance with NZMP 3640. TIMBER ELEMENTS Corsican or radiata pine, selected in accordance with NZS 3602 and treated in accordance with NZMP 3640, as follows:. Horizontal retaining timbers H4 Above ground timber H3.2 FIXINGS AND BOLTS All bolts, nuts and washers shall be stainless steel DRAINAGE MATERIAL Shall be free draining crushed stone, 7mm to 20mm in size. CONCRETE Shall be ordinary grade to NZS 3108, minimum 17.5MPa. Maximum aggregate size 10mm. 1.3 EXECUTION ERECT DRILLED TIMBER POLE WALLS Excavate, form base for, and set poles in concrete in pre-drilled holes. Space poles nominally as specified on the drawings. Place poles butt end down. Do not put cut ends into ground. Treat all cut ends or notches with a liberal brush coat of copper napthenate or equivalent wood preservative. The Engineer is to confirm the adequacy of pole embedment depths prior to placing poles. Install horizontal timbers with staggered joints. All timber joints are to be close butted at poles. Provide 20mm vertical gap between the bottom rails to allow ground water to dissipate when required. Setout tolerances shall be: From pole centre line: max. 60mm from centre line Misalignment: max. 20mm at retaining face Minimum back slope: 4 degrees back slope from vertical Drill diameter: pole butt end diameter + 100mm BACKFILLING Compact backfilling in 150mm loose layers, using a suitable vibrating equipment. Use reduced compactive effort and care within 1.0m of the retaining wall. Place a 300m min wide layer of drainage material immediately adjacent to the retaining wall. Finish backfilling with 150mm of clean topsoil. TAKE AWAY Remove from the site all plant and material not used. 2 SCHEDULE OF INSPECTIONS Site inspections shall be carried out by the Engineer at the following stages of construction: Pole excavation, prior to concreting Pre-pour for deadman and tie back anchors Completed wall. A reasonable notification period of not less than 24 hours shall be provided. Synge Consulting Ltd 1 of 1 18 Nov 2015

Synge Consulting Ltd 3 Vera St, Wellington 6012 Page: 04 4764 328 Ref: 1548 Project: 61 Exploration Way Whitby Date: 1-Dec-15 STRUCTURAL CALCULATIONS