Sure-Weld (TPO) Adhered Roofing Systems Code Approval Guide January, Table of Contents

Similar documents
Code Approval Guide January, 2017

Code Approval Guide Table of Contents February 2012

Code Approval Guide. Underwriters Laboratories FM Approvals. February 2012

Adhered Roofing Systems with Aqua Base 120 Bonding Adhesive. UL/FM Code Approval Guide Table of Contents February 2012

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

Section Property Standard Year Wind FM Physical Properties ASTM D

UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat

UL Evaluation Report UL ER Issued: June 29, 2015 Revised: July 29, UL Category Code: ULFB. CSI MasterFormat

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

C. Applicable building codes should always be checked prior to proposing the application to Mule-Hide or the building owner.

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

PRODUCT CONTROL SECTION

UL Evaluation Report UL ER Issued: December 19, 2014 Revised: August 14, UL Category Code: ULFB. CSI MasterFormat

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

Mechanically Attached and Fully Adhered Roofing Systems

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

POLYISO Polyisocyanurate Roofing Insulation

Thermoplastic Single Ply & Multi-Ply Roofing Systems

NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 250 WEST 96 TH STREET INDIANAPOLIS, INDIANA EVALUATION SUBJECT:

UL Evaluation Report UL ER Issued: December 9, Revised: September 29, UL Category Code: ULFB. CSI MasterFormat

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

PRODUCT CONTROL SECTION

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications

PRODUCT CONTROL SECTION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

JM PVC Fleece Backed 50 mil, JM PVC Fleece Backed 60 mil, JM PVC Fleece Backed 80 mil

PRODUCT CONTROL SECTION

Code Approval Guide. Underwriters Laboratories Factory Mutual. March 2005

Engineering Services Program

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

FOAMULAR Commercial Roofing

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

DESCRIPTION: JM TPO Single Ply Roof Systems

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

CREEK Technical Services, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: POLYVINYL CHLORIDE ROOFING REPORT HOLDER: IB ROOF SYSTEMS

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

B u l l e t i n MODIFIED BITUMEN MEMBRANES OVER SOPRABOARD SYSTEM (AARS) ADHESIVE APPLIED ROOFING SYSTEM

B u l l e t i n SOPRABOARD MECHANICALLY FASTENED OVER POLYISOCYANURATE INSULATION BOARD (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM

EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281

PRODUCT CONTROL SECTION

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # CHRISTIAN STREET, UNIT 13 OXFORD, CT (203)

Adhesive Pull Test Standard Testing Procedures

Mechanically Attached and Fully Adhered Roofing Systems

B u l l e t i n SOPRABOARD MODIFIED BITUMEN SYSTEM (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM

EVALUATION REPORT ICP Adhesives and Sealants, Inc NW 44 th Street Coral Springs, FL 33065

PRODUCT CONTROL SECTION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ROOFING INSTALLATION GUIDELINES

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

Firestone Polyiso Boards

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION

UNA-CLAD Metal Roof Systems Code Approval Guide

EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281

PRODUCT CONTROL SECTION

DESCRIPTION: JM PVC Single Ply Roof Systems

following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.

B u l l e t i n SOPRA-ISO MECHANICALLY FASTENED AND SOPRABOARD ADHERED SYSTEM (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street, Unit 13 Oxford, CT (203)

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT (203)

SL175 Panel Technical Data Guide

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Thermoplastic Metal Retrofit Roofing System

FIRESTONE ULTRAPLYTM TPO. One Source. Many Choices. That s Firestone.

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

B u l l e t i n MOD-BIT COLVENT SYSTEM (AARS) ADHESIVE APPLIED ROOFING SYSTEM

Sub-level 2: Modified Bituminous Membrane Roofing Sub-level 3: Styrene-Butadiene-Styrene Modified bituminous Sheet Roofing

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # CHRISTIAN STREET, UNIT 13 OXFORD, CT (203)


EverGuard TPO/PVC Mechanically Attached Retrofit Roofing Systems Over Metal Roof Panels on Metal Buildings

PRODUCT CONTROL SECTION

4.2 Materials Membranes: inch, inch or inch thick D General

ATLAS ROOFING PRODUCT GUIDE. Polyiso Roof Insulation, SPECIALTY PRODUCTS

Section 7 Waterproofing Roofing Standards

ML200 Panel Technical Data Guide

SECTION THERMOPLASTIC POLYOLEFIN (TPO) MEMBRANE ROOFING (Over Wood)

Subject: NRCA MRCA Joint Technical Bulletin. Date: January 2008 NOT COMPROMISE.

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

UL Listing: EPDM Roofing Systems


Adhered Roofing System Sure-Seal /Sure-White /Sure-Weld /Sure-Flex

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ETHYLENE PROPYLENE DIENE MONOMER ROOFING REPORT HOLDER:

STOMP OUT FLUTTER. Non-penetrating fastening system for thermoplastic roofing

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

COMMERCIAL ROOFING SYSTEMS

SECTION PREPARATION FOR RE-ROOFING

Transcription:

(TPO) Adhered Roofing Systems Code Approval Guide January, 2017 Introduction... ii Guidelines... Mechanically Fastened or Induction Welding Roofing Systems UL Approvals NonCombustible ANSI UL Class A... 4 Combustible ANSI UL Class A... 5 Combustible ANSI UL Class B... 6 Combustible and NonCombustible ANSI UL Class C... 7 Existing UL Retained... 7 FM Approvals FM Approval Field Sheet Securement Criteria... 8 FM Approval Induction Welding Securement Criteria... 9 90 psf Uplift Resistance Test... 10 FM Class A Roof Deck... 11 ANSISPRI... 12 Metal Retrofit Roofing Systems Metal Retrofit... 13 Adhered Roofing Systems UL Approvals NonCombustible ANSI UL Class A... 14 Combustible ANSI UL Class A... 15 Combustible ANSI UL Class B... 17 Combustible and NonCombustible ANSI UL Class C... 18 FM Approvals Table of Contents SecurShield HD New Construction... 19 SecurShield HD Recover... 21 SecurShield HD Plus New Construction... 22 SecurShield HD Plus Recover... 24 InsulBase Polyiso New Construction... 25 InsulBase Polyiso Recover... 27 SecurShield and New Construction... 28 SecurShield Recover... 30 Securock New Construction... 31 Securock Recover... 33 DensDeck Prime New Construction... 34 DensDeck Prime Recover... 36 OSB New Construction... 37 OSB Recover... 38 HP Recovery Board New Construction... 39 HP Recovery Board Recover... 41 Lightweight... 42 National, State & City Building Code Approvals... 43 Dade County (South Florida) Approvals... 43 Reference Notes... 44 iii 600163 SW Codes i 01/2017

CARLISLE SynTec A Division of Carlisle Construction Materials, Incorporated CODE APPROVAL GUIDE January, 2017 INTRODUCTION This Code Approval Guide addresses both general information pertaining to Underwriters Laboratories (UL) and FM Approvals (FM) test criteria as well as specific UL and FM code approvals achieved with Carlisle s TM Adhered and MechanicallyFastened Roofing Systems. Various independent test laboratory results along with national building code approvals are also identified in this guide. Code approvals available with Carlisle s FleeceBack TM, Hot Mopped, Sure Flex and SureSeal Roofing Systems are identified in separately published Code Approval Guides. Code ratings are categorized by roof system type (MechanicallyFastened Adhered) and are separated into two sections: UL Approvals and FM Approvals. UL rated roof assemblies are grouped according to deck type (noncombustible or combustible) and are further categorized according to deck type and the specific type of construction (new, recover, tearoff or retrofit). The listed assemblies contained in the guide are grouped generically based on deck classification. Specific substrate requirements for each Carlisle roofing system can be identified in the respective Carlisle specifications. In the UL and FM Approvals throughout this guide, when multiple layers of insulation are referenced, the product listed first identifies the insulation directly below the membrane. For example; a listing of HP Recovery Board/Polyisocyanurate indicates the HP Recovery Board is installed directly under the membrane. A listing of Gypsum Board/Polystyrene indicates the Gypsum Board is installed directly under the membrane. 600163 SW Codes ii 01/2017

GENERAL GUIDELINES FOR UL AND FM APPROVALS CODE COMPLIANCE No table of figures entries found. Approvals (FM) approved assembly is specified. Generally, the Carlisle published specifications reflect the minimum requirements necessary to obtain the applicable Carlisle warranty. Code requirements are not specifically covered in the Carlisle specifications and are considered to be above and beyond the provisions of the Carlisle warranty. Individuals specifying an approved assembly or selecting various products to achieve a specific UL/FM rating must recognize the importance of ensuring proper component selection to fully comply with the most current listings published. All materials used in the roofing systems must be UL and/or FM approved and must have been tested together as part of a complete roof assembly. In addition to the code approval listings in this guide, information pertaining to approved assemblies can also be obtained directly from UL and FM as follows: 1. Underwriters Laboritories OnLine Certification Directory (ul.com) 2. FM Approvals RoofNav website (roofnav.com). FM RoofNav assembly numbers can be obtained from this website. Underwriters Laboratories UL, FM Approvals and ASNI/SPRI WD1 Clarifications/Enhancements 1. The criteria required to obtain UL External fire ratings (Class A, B or C) can be identified in this guide or can be searched for on the UL website using the UL Category Code TGFU. UL ratings approved for use on combustible decks are also acceptable on noncombustible decks. 2. For UL internal fire ratings (hourly constructions P Numbers), search the UL website use the UL Category Code BXUV. FM Approvals Uplift ratings listed in this guide are for the field of the roof. Additional requirements/enhancements are required by FM in the perimeter and corner areas, for deck securement and for perimeter nailer/edge attachment. Refer to FM Property Loss Prevention Data Sheets 128, 129 and 149 for specific requirements. On FM insured projects, the FM insuring agent MUST review and approve the proposed roofing assembly prior to installation. When FM is not the insuring entity for the building, use the Approved American National Standard ANSI/SPRI WD1 for design purposes. Note: All Carlisle roof systems referenced within this document meet Class 1 construction and Severe Hail (SH) rating. Approved American National Standard ANSI/SPRI WD1 The ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies should be referenced when a project is not FM insured. This document was developed as a consensus National Standard and provides a methodology for designing for wind uplift resistance of roofing system assemblies. Insulation fastening patterns are included in this document. The fastening patters are approved for use by Carlisle. RECOVERS Recover approvals in this document are based on the following existing roofing system assumption the existing Smooth Asphalt BUR, Modified Bitumen or singleply system was FM Approved at the time of installation. SUMMARY Due to complexity of the code documents and the variety of information that must be reviewed, it is important to consult with Carlisle and other respective manufactures concerning the most current available approvals. Prior to project bid Products specified by the architect must be thoroughly investigated to determine if the specified rating can be achieved and local building codes must be consulted regarding any additional requirements. Prior to installation Project managers should review the code requirements with field construction personnel to ensure compliance with project requirements. Upon completion of the roofing installation, each project is inspected by a Carlisle Technical Representative to ensure compliance with Carlisle s current specification requirements for the issuance of the applicable warranty. However, this inspection is not for the purpose of verifying code compliance. 600163 SW Codes iii 01/2017

(TPO) MechanicallyFastened or Induction Welding Roofing Systems UL Approval NonCombustible ANSI/UL 790 Spread of Flame Test (Class A) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) NonCombustible: Steel; St. Concrete; Gypsum; Tectum (Min. 2" thick) Maximum Slope System ID Deck Type Insulation Cover Board, or Spectro Weld HS 1 InsulBase, SecurShield, SecurShield HD, SecurShield HD Plus or any combination, any thickness N/A 1/2" 11/2" 2 Any UL Classified EPS or XPS Insulation, any thickness Minimum 1/2 SecurShield HD, SecurShield HD Plus or 1/2" 1/2" 3 4 5 Minimum 1 layer of InsulBase, SecurShield, or SecurShield HD Composite over any UL Classified EPS or XPS Insulation, maximum 1.25 pcf, any thickness Insulfoam SP or Insulfoam SP over Insulfoam EPS, any thickness and density. Insulfoam HD Composite or Insulfoam HD Composite over Insulfoam EPS, any thickness and density. N/A 1/2" 1/2" N/A 1" 1" N/A 1/2" 1/2" NonCombustible 6 Any UL Classified Insulation, any thickness (OPTIONAL) 7 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4 SECUROCK GypsumFiber Board Minimum 1/4 SECUROCK Glass Mat Board 3" 3" 3" Unlimited 8 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4 DensDeck/DensDeck Prime Roof Boards 3" 21/2" Unlimited 9 Any UL Classified Insulation, any thickness (OPTIONAL) 10 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/2 HP Recovery Board Minimum 7/16 APA Rated OSB or Minimum 11/2 StormBase 11/2" 11/2" 11/2" 11/2" 11 Any UL Classified Insulation, any combination, any thickness Carlisle FR Base Sheet 1" 1" 12 Cellular Lightweight Concrete N/A N/A 11/2" 11/2" 13 Structural (pouredinplace) concrete N/A N/A 11/2" 11/2" 600163 SW Codes Page 4 of 44 01/2017

(TPO) MechanicallyFastened or Induction Welding Roofing Systems UL Approval Combustible ANSI/UL 790 Spread of Flame Test (Class A) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Combustible: 7/16in. (minimum) thick nonveneer APArated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) System ID Thermal Barrier/Base Sheet Insulation Cover Board Combustible ANSI/UL 790 Spread of Flame TestClass A Maximum Slope, Sure Weld or SpectroWeld HS 1 Minimum 1/4 SECUROCK Gypsum Fiber or Glass Mat Roof Boards (1) Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A 1/2 1/2" 2 Minimum 1/4 DensDeck/DensDeck Prime Roof Boards (1) Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A 1/2" 1/2" 3 N/A 4 N/A 5 Carlisle FR Base Sheet Minimum 3 layer or two layers of 11/2 SecurShield or. (1)(3) Minimum 21/2 layer SecurShield or SecurShield HD Composite over a 21/2 (minimum) layer of Carlisle InsulBase Insulation. (1)(4) Minimum 1.9 layer of SecurShield or SecurShield HD Composite. (1)(4) N/A 1/2" 1/2" N/A 1/2" 1/2" N/A 1/2" 1/2" 6 N/A Minimum 21/2 layer of any UL Classified Carlisle Polyisocyanurate Insulation, any combination. (1) Minimum 1/2 SecurShield HD or SecurShield HD Plus 1/2" 1/2" 7 Carlisle FR Base Sheet Minimum 1.4 layer of any UL Classified Carlisle Polyisocyanurate Insulation, any combination. (1) Minimum 1/2 SecurShield HD or SecurShield HD Plus 1/2" 1/2" 8 N/A Minimum 1 layer of SecurShield CD. (1)(5) N/A 1/2" 1/2" 9 N/A Minimum 4 layer of any UL Classified EPS Insulation. (1)(6) Minimum 1/2 SecurShield HD or SecurShield HD Plus 1/2" 1/2" 10 N/A 11 N/A 12 N/A Minimum 1 layer of SecurShield CD over a minimum 31/2 layer of any UL Classified EPS Insulation. (1)(6) Minimum 11/2 layer of Insulfoam HD Composite over a minimum 3 layer of Insulfoam EPS. (1)(6) Minimum 2 layer of Insulfoam HD Composite over a minimum 21/2 layer of Insulfoam EPS. (1)(6) N/A 1/2" 1/2" N/A 1/2" 1/2" N/A 1/2" 1/2" 13 N/A Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. Minimum 1/4 SECUROCK Gypsum Fiber Roof Board (1) 3" 3" 14 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 3/8 SECUROCK Gypsum Fiber Roof Board (1) 3" 3" 15 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/2 SECUROCK Gypsum Fiber Roof Board (1) 3" 3" 16 One Ply of Type G2 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4 SECUROCK Gypsum Fiber Roof Board (1) 3" 3" 17 N/A Any UL Classified Insulation, any thickness (OPTIONAL) 18 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4 SECUROCK Glass Mat Roof Board (1) Minimum 1/4 Dens Deck/DensDeck Prime Roof Boards (1) 3 21/2 3 21/2 Unlimited Unlimited 19 Two layers of Carlisle FR Base Sheet Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A 1/2" 1/2" 600163 SW Codes Page 5 of 44 01/2017

(TPO) MechanicallyFastened or Induction Welding Roofing Systems UL Approval Combustible ANSI/UL 790 Spread of Flame Test (Class B) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Combustible: 7/16in. (minimum) thick nonveneer APArated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) Maximum Slope System ID Thermal Barrier/Base Sheet Insulation Cover Board (2), or SpetroWeld HS Combustible ANSI/UL 790 Spread of Flame TestClass B 1 N/A Minimum 1.9 layer of SecurShield or SecurShield HD Composite. (7)(8) N/A 1/2" 1/2" 2 N/A Minimum 1.4 layer of any UL Classified Carlisle Polyisocyanurate Insulation. (7) Minimum 1/2 SecurShield HD or SecurShield HD Plus 1/2" 1/2" 3 N/A Minimum 1 layer of SecurShield CD. (7)(9) N/A 1/2" 1/2" 4 One Layer of Carlisle FR Base Sheet Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. (OPTIONAL) N/A 1/2" 1/2" 5 Inverted G3 cap sheet N/A N/A 1/2" 1/2" 600163 SW Codes Page 6 of 44 01/2017

(TPO) MechanicallyFastened or Induction Welding Roofing Systems UL Approval Combustible and NonCombustible ANSI/UL 790 Spread of Flame Test (Class C) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Combustible: 7/16in. (minimum) thick nonveneer APArated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) NonCombustible: Steel, St. Concrete, Gypsum or Tectum (Min. 2" thick) Maximum Slope System ID Thermal Barrier/Base Sheet Insulation Cover Board Combustible ANSI/UL 790 Spread of Flame TestClass C, or SpectroWeld HS 1 N/A Any combination, any thickness of UL Classified Carlisle Polyisocranurate Isulation N/A Unlimited Unlimited NonCombustible ANSI/UL 790 Spread of Flame TestClass C 1 N/A Any combination, any thickness of UL Classified Carlisle Polyisocyanurate Insulation. N/A Unlimited Unlimited Existing UL Retained NonCombustible or Combustible (Directly over existing Class A, B or C) Maximum Slope System ID Deck Type Existing Substrate Insulation, or SpectroWeld HS 1 N/A Direct application over Smooth Asphalt BUR (Type III or IV Asphalt) N/A 1/2" 1/2" 2 N/A Direct application over Mineral Surfaced Cap Sheet N/A 1/2" 1/2" 3 N/A Direct application over Modified Bitumen N/A 1/2" 1/2" 4 N/A Direct application over approved singleply N/A 1/2" 1/2" 5 N/A Carlisle FR Base Sheet IS over existing min. UL Class "C" rated Type III or IV Smooth Asphalt BUR, Mineral Cap Sheet, Modified Bitumen or approved singleply to remain Base Sheet 1/2" 3/4" 6 N/A Existing minimum Class C smooth or gravel surface (gravel maintained) DUR, mineral cap sheet or Modified Bitumen Max. 1" Insulfoam RTech or SP 1/2" 1/2" 600163 SW Codes Page 7 of 44 01/2017

(TPO) MechanicallyFastened or Induction Welding Roofing Systems FM Approvals and Equivalencies FM Approval Field Sheet Securement Criteria (Please see notes 10, 11, 12 and 15) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Membrane Width (11) Fastener/Plate (12) Spacing, or Spectro Weld Min. 22 Gauge Grade C Steel (33 ksi) HS Min. 22 Gauge Grade E Steel (80 ksi) (13) or Structural Concrete, Sure Weld or SpectroWeld HS Min. 18 Gauge Steel or 4 Feet (14) HPX /Piranha 6" 12" 1165 13610200 1105 13610100 1165 13610200 6 Feet HPX/Piranha 12" 190 39218300 8 Feet 10 Feet 12 Feet HPX /Piranha HPXtra /Piranha Xtra 6" HPXtra /Piranha Xtra 12 HPX /Piranha HPXtra /Piranha Xtra HPX /Piranha 175 35039200 1135 1249600 12 175 190 39218400 1256200 175 35039400 12 1120 10620200 190 175 14300000 14299600 190 10746900 6 190 12 1278800 6 12 6 175 14299600 6 12 175 175 190 10747000 10620500 1280700 1105 14098600 175 10619700 160 160 160 14054800 10620100 14054800 1120 14102300 175 14298300 1120 14104200 1120 14102300 () directly over Min. 1.5" of InsulBase Polyiso or SecurShield 600163 SW Codes Page 8 of 44 01/2017

Induction Welding Grid Securement.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Fasteners per 4 x 8 Board Deck Type Fastener/Plate Field Perimeter Corner Min. 22 gauge Grade C Steel Deck HPX/Induction Plate HPX/RhinoBond HPX/IsoWeld 6 190 RhinoBond and IsoWeld RB 22255500 10 16 IW 37885300 8 1105 (RhinoBond Only) 16 20 22255300 1150 (IsoWeld Only) 10 37889000 20 25 HPX/RhinoBond 1165 (RhinoBond Only) 16 38636700 28 40 Min. 22 gauge Grade E Steel Deck HPX / RhinoBond HPX/RhinoBond 8 1120 (RhinoBond Only) 16 20 22237500 1195 (RhinoBond Only) 16 38716100 190 RhinoBond 6 10 16 28 40 Concrete HD 1410/RhinoBond 1105 (RhinoBond Only) 1120 (RhinoBond Only) 8 31196700 8 31256900 16 20 16 20 1195 (RhinoBond Only) 16 38636900 28 40 FM Approvals Induction Welding Linear Securement Deck Type Fastener Plate Row Spacings Fastener Spacing in Rows Min. 22 gauge Grade E Steel Deck HPX RhinoBond 5 12 5 6 10' 6" 175 32335300 1135 32335500 175 32339800 () over InsulBase Polyiso 600163 SW Codes Page 9 of 44 01/2017

90 psf Uplift Resistance Test (190 Equivalency on 12 x 24 Table) Wind uplift testing has been completed in accordance with the FM 4470 Test Procedure which is witnessed and certified by Architectural Testing, Incorporated, an industry recognized Independent Testing Laboratory. Over a 22 gauge Grade E Steel roof deck, the following results were obtained using HPX Fasteners and Piranha Plates for membrane securement. The Performance Test Report is on file and available from Carlisle..045" or.060" Standard Reinforced Membrane (white, gray or tan). Deck Type Field Membrane Width Fastener Spacing Insulation Type and Thickness Insulation Fastening 10 Min. 22 gauge See notes 16 and 17. 12 Per Carlisle Specification Per Carlisle Specification 600163 SW Codes Page 10 of 44 01/2017

(TPO) MechanicallyFastened or Induction Welding Roofing Systems FM Class A Roof Deck Construction and Insulation Approvals (18).045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Maximum Slope for Deck Type Insulation (19) Insulation Thickness ASTM E108 Class A, or SpectroWeld HS Carlisle HP Recovery Board 1/2" Min. New Construction/Tearoff: Steel (Minimum 22 gauge) Structural Concrete Carlisle HP Recovery Board (min. 1/2"), DensDeck (min. 1/4 ) or Securock (min. 1/4") Over: FM Approved Insulation (20) Refer to FM RoofNav website 11/2 (with Recovery Board or Securock overlay) 5 (with DensDeck overlay and Standard) 3 (with DensDeck overlay and ) 2 (with Recovery Board or Securock overlay) 5 (with DensDeck overlay) Retrofit (No Tearoff) (21): Structural Concrete Carlisle Polyisocyanurate InsulBase or SecurShield 11/2"12" Carlisle SecurShield HD or SecurShield HD Plus Over: FM Approved Insulation (20) 1/2" / Refer to FM RoofNAV website 1/2 11/2 Carlisle HP Recovery Board 1/2"1" 11/2 2 Retrofit (No Tearoff) (21): Steel (Minimum 22 gauge) Carlisle Polyisocyanurate InsulBase or SecurShield 1" Max. Carlisle SecurShield HD or SecurShield HD Plus 1/2" 1/2 11/2 600163 SW Codes Page 11 of 44 01/2017

Membrane Type: (TPO) Mechanically Fastened or Induction Welding Roofing Systems.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) ANSISPRI WD1/ASCE 710 Approvals Membrane Width Fastener/Plate Spacing Min. 22 Gauge Grade C Steel (33 ksi), or Spectro Weld HS Min. 22 Gauge Grade E Steel (80 ksi) or Structural Concrete, or Spectro Weld HS Wood Deck, Sure Weld or SpectroWeld Min. 18 Gauge Steel or Sure Weld 4 Feet HPX /Piranha 6" 1165 1165 12" 1105 1105 6 Feet HPX/Piranha 12" 190 8 Feet HPX /Piranha 6 1105 1135 1120 190 12 175 160 190 175 175 HPXtra /Piranha Xtra 12 190 175 190 175 6 1105 190 1120 175 HPX /Piranha 9 175 160 190 190 10 Feet 12 160 175 175 190 HPXtra /Piranha Xtra 6 1120 1120 12 160 190* 6 1105 1120 175 HPX /Piranha 9 175 160 175 12 Feet 12 160 160 160 6 1120 1120 HPXtra /Piranha Xtra 9 175 175 12 160 160 *Max 175 using SpectroWeld 600163 SW Codes Page 12 of 44 01/2017

Underwriters Laboratories (UL) Approvals FM Approvals Metal Retrofit Roofing System The UL ratings achieved with the Metal Retrofit Roofing System are identical to the approvals listed for the TM MechanicallyFastened Roofing System over noncombustible decks depending on the membrane selected. Click here for ratings. As referenced in FM Approvals Loss Prevention Data Sheet 131, the method of recovering an existing metal roof system with a singleply mechanically fastened roofing system where the membrane is secured through the existing metal roof directly to the structural purlins is recognized as an appropriate recovery system when installed per the recommendations of FM. As a standard FM Approvals requirement, additional membrane and insulation securement is necessary in the corner and/or perimeter areas as outlined in FM Property Loss Prevention Data Sheets 128, 129 and 131. These bulletins should be reviewed in their entirety for specific requirements concerning insulation types, fastening enhancements and other items that may be necessary. Purlin Spacing Fastener/Plate Spacing FM Approvals Metal Retrofit, or SpectroWeld HS 6 60 Inches HP Purlin/Piranha 12" 6 120 Inches HP Purlin/Piranha 12 138 inches HP Purlin/Piranha 6" 1135 27245400 175 27251300 1120 27271000 160 27264200 1105 27266300 1120 175 175 160 175 () For selected systems using 1/4" thick Gypsum top layer. FM Approvals Metal Retrofit PressureSensitive RUSS Strip Purlin Spacing Fastener/Plate Spacing, or SpectroWeld HS 60 Inches HP Purlin/Piranha 120 Inches HP Purlin/Piranha 12" 6 12 1120 27256800 1120 27256300 175 27257600 () For selected systems using 1/4" thick Gypsum top layer. 175 175 160 FM Approvals Induction Welding Metal Retrofit Deck Type Fastener Plate Row Spacings Fastener Spacing in Rows Structural Steel Purlin (Metal Retrofit) 5 12 HP Purlin RhinoBond 5 6 10 6 () For selected systems using 1/4" thick Gypsum top layer. 175 37350100 1135 37350500 175 37349800 600163 SW Codes Page 13 of 44 01/2017

(TPO) Adhered Roofing Systems UL Approval NonCombustible ANSI/UL 790 Spread of Flame Test (Class A) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) NonCombustible: Steel; St. Concrete; Gypsum; Tectum (Min. 2" thick) Maximum Slope System ID Deck Type Insulation Cover Board or SpectroWeld HS 1 2 3 4 5 6 Non Combustible InsulBase, SecurShield, SecurShield HD, SecurShield HD Plus or any combination, any thickness Any UL Classified EPS or XPS Insulation, any thickness Minimum 1 layer of InsulBase, SecurShield, or over any UL Classified EPS or XPS Insulation, maximum 1.25 pcf, any thickness Insulfoam HD Composite or Insulfoam HD Composite over Insulfoam EPS, any thickness and density. Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) N/A 1/4" 1/2" 1/4" Minimum 1/2 SecurShield HD, SecurShield HD Plus or SecurShield HD Composite 1/4" 1/2" 1/4" N/A 1/4" 1/2" 1/4" N/A 1/4" 1/2" 1/4" Minimum 1/4 SECUROCK Gypsum Fiber Minimum 1/4" DensDeck Prime Roof Boards 3" 3" 21/2" 3" Unlimited 21/2" 7 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/2 HP Recovery Board 11/2" 1" 1/4" 8 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 7/16 APA Rated OSB or Minimum 11/2 StormBase 11/2" 1" 1/4" 9 10 Cellular Lightweight Concrete Structural (pouredinplace) concrete N/A N/A 3" Unlimited 21/2" N/A N/A 3" Unlimited 21/2" 600163 SW Codes Page 14 of 44 01/2017

(TPO) Adhered Roofing Systems UL Approval Combustible ANSI/UL 790 Spread of Flame Test (Class A) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Combustible: 7/16in. (minimum) thick nonveneer APArated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) Maximum Slope System ID Thermal Barrier/ Base Sheet Insulation Cover Board (26) or Spectro Weld HS Combustible ANSI/UL 790 Spread of Flame TestClass A 1 2 Minimum 1/4 SECUROCK Gypsum Fiber Any UL Classified Carlisle Polyisocyanurate Insulation, or Glass Mat Roof Boards any combination, any thickness. (25) Minimum 1/4 DensDeck/DensDeck Prime Roof Boards (25) Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A 1/4" 1/2" 1/4" N/A 1/4" 1/2" 1/4" 3 N/A Minimum 3 layer or two layers of 11/2" SecurShield or. (25)(27) N/A 1/4" 1/2" 1/4" 4 N/A Minimum 21/2" layer SecurShield or SecurShield HD Composite over a 21/2" (minimum) layer of Carlisle InsulBase Insulation. (25)(28) N/A 1/4" 1/2" 1/4" 5 Carlisle FR Base Sheet Minimum 19/10 layer of SecurShield or SecurShield HD Composite. (25)(28) N/A 1/4" 1/2" 1/4" 6 N/A Minimum 21/2" layer of any UL Classified Carlisle Polyisocyanurate Insulation, any combination. (25) Minimum 1/2 SecurShield HD or SecurShield HD Plus 1/4" 1/2" 1/4" 7 Carlisle FR Base Sheet Minimum 11/4 layer of any UL Classified Carlisle Polyisocyanurate Insulation, any combination. (25) Minimum 1/2 SecurShield HD or SecurShield HD Plus 1/4" 1/2" 1/4" 8 N/A Minimum 1 layer of SecurShield CD. (25)(29) N/A 1/4" 1/2" 1/4" 9 N/A Minimum 4 layer of any UL Classified EPS Insulation. (25)(30) Minimum 1/2 SecurShield HD or SecurShield HD Plus 1/4" 1/2" 1/4" 10 N/A 11 N/A Minimum 1 layer of SecurShield CD over a minimum 31/2 layer of any UL Classified EPS Insulation. (25)(30) Minimum 11/2 layer of Insulfoam HD Composite over a minimum 3 layer of Insulfoam EPS. (25)(30) N/A 1/4" 1/2" 1/4" N/A 1/4" 1/2" 1/4" 12 N/A Minimum 2 layer of Insulfoam HD Composite over a minimum 21/2" layer of Insulfoam EPS. (25)(30) N/A 1/4" 1/2" 1/4" 13 N/A Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. Minimum 1/4 SECUROCK Gypsum Fiber Roof Board (25) 3" 3" 21/2" 14 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 3/8 SECUROCK Gypsum Fiber Roof Board (25) 3" 3" 21/2" 15 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/2 SECUROCK Gypsum Fiber Roof Board (25) 3" 3" 21/2" 600163 SW Codes Page 15 of 44 01/2017

(TPO) Adhered Roofing Systems UL Approval Combustible ANSI/UL 790 Spread of Flame Test (Class A) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Combustible: 7/16in. (minimum) thick nonveneer APArated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) Maximum Slope System ID Thermal Barrier/ Base Sheet Insulation Cover Board (26) or Spectro Weld HS 16 One Ply of Type G2 17 N/A Combustible ANSI/UL 790 Spread of Flame TestClass A Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4 SECUROCK Gypsum Fiber Roof Board (25) Minimum 1/4 DensDeck Prime Roof Board (25) 3" 3" 21/2" 3" Unlimited 21/2" 600163 SW Codes Page 16 of 44 01/2017

(TPO) Adhered Roofing Systems UL Approval Combustible ANSI/UL 790 Spread of Flame Test (Class B) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Combustible: 7/16in. (minimum) thick nonveneer APArated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) System ID Thermal Barrier/Base Sheet Insulation Cover Board or SpectroWeld Maximum Slope HS Combustible ANSI/UL 790 Spread of Flame TestClass B 1 N/A Minimum 19/10 layer of SecurShield or SecurShield HD Composite. (31)(32) N/A 1/4" 1/2" 1/4" 2 N/A Minimum 12/5 layer of any UL Classified Carlisle Polyisocyanurate Insulation. (31) Minimum 1/2" SecurShield HD or SecurShield HD Plus 1/4" 1/2" 1/4" 3 N/A Minimum 1 layer of SecurShield CD. (31)(33) N/A 1/4" 1/2" 1/4" 4 One Layer of Carlisle FR Base Sheet Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A 1/4" 1/2" 1/4" 600163 SW Codes Page 17 of 44 01/2017

(TPO) Adhered Roofing Systems UL Approval Combustible and NonCombustible ANSI/UL 790 Spread of Flame Test (Class C) Membrane Type:.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Combustible: 7/16in. (minimum) thick nonveneer APArated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) NonCombustible: Steel, St. Concrete, Gypsum or Tectum (Min. 2" thick) System ID Thermal Barrier/Base Sheet Insulation Cover Board or SpectroWeld Maximum Slope HS Combustible ANSI/UL 790 Spread of Flame TestClass C 1 N/A Any combination, any thickness of UL Classified Carlisle Polyisocranurate Isulation N/A Unlimited Unlimited Unlimited NonCombustible ANSI/UL 790 Spread of Flame TestClass C 1 N/A Any combination, any thickness of UL Classified Carlisle Polyisocyanurate Insulation. N/A Unlimited Unlimited Unlimited 600163 SW Codes Page 18 of 44 01/2017

SecurShield HD s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening (mechanically fastened see Top Insulation Layer or SpectroWeld HS Steel Deck (Min. 22 Gauge) Min. 11/2" InsulBase Polyiso or SecurShield Loose laid 1/2" SecurShield HD 12 (2.67 sq. ft) 175 29574700 29574700 29574700 Min. 11/2" InsulBase Polyiso or SecurShield Loose laid 1/2" SecurShield HD 16 (2 sq. ft) 190 38590900 Min. 11/2" InsulBase Polyiso 10 (3.2 sq. ft.) 1/2" SecurShield HD 6" ribbons of FAST 190 35387400 Min. 2" InsulBase Polyiso 8 (4 sq. ft) 1/2" SecurShield HD 6" ribbons of FAST 190 35387500 Min. 11/2" InsulBase Polyiso 18 (1.8 sq. ft.) 1/2" SecurShield HD 6" ribbons of FAST 1105 Min. 11/2" InsulBase Polyiso 24 (1.33 sq. ft.) 1/2" SecurShield HD 6" ribbons of FAST 1150 Min. 11/2" InsulBase Polyiso 24 (1.33 sq. ft.) 1/2" SecurShield HD 4" ribbons of FAST 1165 32593900 32594100 32594000 35391600 35391700 32601400 32601900 32601700 35391800 35391900 Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.) 1/2" SecurShield HD over InsulBase Polyiso 6" ribbons FAST 190 Steel Deck (Min. 22 Gauge)/VapAir Seal 725TR with CavGrip Primer Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.) 1/2" SecurShield HD over InsulBase Polyiso 6" ribbons of FAST 190 Concrete Deck Min. 1/2" InsulBase Polyiso FAST 1/2" SecurShield HD FAST 1225 38122600 38299700 38299800 Min. 1/2" InsulBase Polyiso 1/2" SecurShield HD 1240 Min. 1/2" InsulBase Polyiso Hot Asphalt 1/2" SecurShield HD Hot Asphalt 1240 Concrete Deck/VapAir Seal 725TR with CavGrip Primer, Carlisle 702 LV Primer or Carlisle 702 Primer 1240 CavGrip 36450700 36450800 36450900 Min. 1/2" InsulBase Polyiso FAST 1/2" SecurShield HD FAST 1225 CavGrip 1195 702 LV 190 702 36452300 36452600 36452500 36462100 36462000 36463500 36463700 600163 SW Codes Page 19 of 44 01/2017

SecurShield HD s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening (mechanically fastened see Top Insulation Layer or SpectroWeld HS Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/CutBack Asphalt Primer Min. 1/2" InsulBase Polyiso or Min. 11/2" SecurShield FAST 1/2" SecurShield HD FAST 1240 39296500 39296600 39296700 Tectum Deck Min. 11/2" InsulBase Polyiso FullCoverage of FAST 1/2" SecurShield HD FullCoverage of FAST 1150 Min. 11/2" InsulBase Polyiso 1/2" SecurShield HD 190 Gypsum Deck TearOff Min. 11/2" InsulBase Polyiso 1/2" SecurShield HD 190 Cellular Lightweight Insulating Concrete/Steel Decking (Min. 22 Gauge) FM Approved Loose laid 1/2" SecurShield HD 12 (2.67 sq. ft) 175 FM Approved Loose laid 1/2" SecurShield HD 16 (2 sq. ft) 190 1/2" SecurShield HD 12 (2.67 sq. ft) 175 1/2" SecurShield HD 16 (2 sq. ft) 190 4" ribbons of FAST 1/2" SecurShield HD 4" ribbons of FAST 1135 1/2" SecurShield HD 4" ribbons of FAST 1135 (Celcore) Cellular Lightweight Insulating Concrete/Concrete Decking Min. 1/2" InsulBase Polyiso 4" ribbons of FAST 1/2" SecurShield HD 4" ribbons of FAST 1135 1/2" SecurShield HD 4" ribbons of FAST 1135 600163 SW Codes Page 20 of 44 01/2017

SecurShield HD s Recover.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer or SpectroWeld HS Steel Deck (Min. 22 Gauge) 1/2" SecurShield HD 12 (2.67 sq. ft) 175 29938400 29938400 29938400 1/2" SecurShield HD 16 (2 sq. ft) 190 1/2" SecurShield HD 6" ribbons of FAST 190 1/2" SecurShield HD 4" ribbons of FAST 1150 Concrete Deck Min. 1/2" InsulBase Polyiso 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1150 1/2" SecurShield HD 6" ribbons of FAST 1150 38942800 38943000 38942900 Tectum Deck 1/2" SecurShield HD FullCoverage FAST 1150 1/2" SecurShield HD 6" ribbons of FAST 190 1/2" SecurShield HD 4" ribbons of FAST 1150 1/2" SecurShield HD Gypsum Deck TearOff 190 1/2" SecurShield HD 6" ribbons of FAST 190 38625400 38625500 1/2" SecurShield HD 190 600163 SW Codes Page 21 of 44 01/2017

SecurShield HD Plus s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer or Spectro Weld HS Steel Deck (Min. 22 Gauge) Min. 11/2" InsulBase Polyiso or SecurShield Loose laid 1/2" SecurShield HD Plus 8 (4 sq. ft) 190 32593300 32600200 Min. 11/2" InsulBase Polyiso or SecurShield Loose laid 1/2" SecurShield HD Plus 18 (1.8 sq. ft) 1120 32593400 32600500 Min. 11/2" InsulBase Polyiso or SecurShield Loose laid 1/2" SecurShield HD Plus 24 (1.33 sq. ft) 1150 32593600 32602400 Min. 11/2" InsulBase Polyiso or SecurShield Loose laid 1/2" SecurShield HD Plus 24 (1.33 sq. ft) 1225 (35) 32593700 32601000 Min. 11/2" InsulBase Polyiso or SecurShield 10 (3.2 sq. ft.) 1/2" SecurShield HD Plus 6" ribbons of FAST 190 35387400 35391600 35391800 Min. 2" InsulBase Polyiso 8 (4 sq. ft) 1/2" SecurShield HD Plus 6" ribbons of FAST 190 35387500 35391700 35391900 Min. 11/2" InsulBase Polyiso 18 (1.8 sq. ft.) 1/2" SecurShield HD Plus 6" ribbons of FAST 1105 Min. 11/2" InsulBase Polyiso 24 (1.33 sq. ft.) 1/2" SecurShield HD Plus 4" ribbons of FAST 1150 Min. 11/2" InsulBase Polyiso 24 (1.33 sq. ft.) 1/2" SecurShield HD Plus 4" ribbons of FAST 1165 Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.) 1/2" SecurShield HD Plus over InsulBase Polyiso 6" ribbons of FAST 190 Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.) Steel Deck (Min. 22 Gauge)/VapAir Seal 725TR with CavGrip Primer 1/2" SecurShield HD Plus over InsulBase Polyiso Concrete Deck 6" ribbons of FAST 190 Min. 1/2" InsulBase Polyiso FAST 1/2" SecurShield HD Plus FAST 1225 38122600 38299700 38299800 Min. 1/2" InsulBase Polyiso 1/2" SecurShield HD Plus 1240 Min. 1/2" InsulBase Polyiso Hot Asphalt 1/2" SecurShield HD Plus Hot Asphalt 1240 Concrete Deck/VapAir Seal 725TR with CavGrip Primer, Carlisle 702 LV Primer or Carlisle 702 Primer 1255 CavGrip 36450700 36452300 36450800 36450900 Min. 1/2" InsulBase Polyiso or Min. 11/2" SecurShield FAST 1/2" SecurShield HD Plus FAST 1195 702 LV 36452600 36452500 36462100 36462000 36463500 36463700 190 702 600163 SW Codes Page 22 of 44 01/2017

SecurShield HD Plus s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer or Spectro Weld HS Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/CutBack Asphalt Primer Min. 1/2" InsulBase Polyiso or Min. 11/2" SecurShield FAST 1/2" SecurShield HD Plus FAST 1240 39296500 39296600 39296700 Tectum Deck Min. 11/2" InsulBase Polyiso FullCoverage FAST 1/2" SecurShield HD Plus FullCoverage FAST 1150 Min. 11/2" InsulBase Polyiso 1/2" SecurShield HD Plus Gypsum Deck TearOff 190 Min. 11/2" InsulBase Polyiso FullCoverage FAST 1/2" SecurShield HD Plus FullCoverage FAST 190 Min. 11/2" InsulBase Polyiso 1/2" SecurShield HD Plus (Celcore) Cellular Lightweight Insulating Concrete/Steel Decking (Min. 22 Gauge) 190 FM Approved Loose laid 1/2" SecurShield HD Plus 12 (2.67 sq. ft) 175 FM Approved Loose laid 1/2" SecurShield HD Plus 16 (2 sq. ft) 190 1/2" SecurShield HD Plus 12 (2.67 sq. ft) 175 1/2" SecurShield HD Plus 16 (2 sq. ft) 190 Min. 11/2" InsulBase Polyiso 4" ribbons of FAST 1/2" SecurShield HD Plus 4" ribbons of FAST 1135 1/2" SecurShield HD Plus 4" ribbons of FAST 1135 (Celcore) Cellular Lightweight Insulating Concrete/Concrete Decking Min. 1/2" InsulBase Polyiso 4" ribbons of FAST 1/2" SecurShield HD Plus 4" ribbons of FAST 1135 1/2" SecurShield HD Plus 4" ribbons of FAST 1135 600163 SW Codes Page 23 of 44 01/2017

SecurShield HD Plus s Recover.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Base and Top Layer Adhesive: Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base Insulation Layer Base Layer Fastening Top Insulation Layer or SpectroWeld HS Steel Deck (Min. 22 Gauge) 1/2" SecurShield HD Plus 8 (4 sq. ft) 190 1/2" SecurShield HD Plus 6" ribbons of FAST 190 1/2" SecurShield HD Plus 4" ribbons of FAST 1150 Concrete Deck Min. 1/2" InsulBase Polyiso 6" ribbons of FAST 1/2" SecurShield HD Plus 6" ribbons of FAST 1150 1/2" SecurShield HD Plus 6" ribbons of FAST 1150 Tectum Deck Min. 11/2" InsulBase Polyiso FullCoverage FAST 1/2" SecurShield HD Plus FullCoverage FAST 1150 Min. 11/2" InsulBase Polyiso 1/2" SecurShield HD Plus 190 Gypsum Deck TearOff Min. 11/2" InsulBase Polyiso FullCoverage FAST 1/2" SecurShield HD Plus FullCoverage FAST 190 Min. 11/2" InsulBase Polyiso 1/2" SecurShield HD Plus 190 600163 SW Codes Page 24 of 44 01/2017

InsulBase Polyiso s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer Steel Deck (Min. 22 Gauge) or Spectro Weld Sure Weld HS Min. 11/2" InsulBase Polyiso 16 (2 sq. ft) 190 1322100 1325600 6340000 Min. 2" InsulBase Polyiso 8 (4 sq. ft) 190 1322200 1325900 6340100 Min. 2" InsulBase Polyiso 20 (1.6 sq. ft) 1150 13547600 13547400 13547700 Min. 11/2" InsulBase Polyiso 10 (3.2 sq. ft.) Min. 11/2" InsulBase Polyiso FAST 190 Min. 2" InsulBase Polyiso 8 (4 sq. ft) Min. 2" InsulBase Polyiso FAST 190 18886300 18887800 18890000 Min. 11/2" InsulBase Polyiso 18 (1.8 sq. ft.) Min. 11/2" InsulBase Polyiso 6" ribbons of FAST 1105 Min. 11/2" InsulBase Polyiso 24 (1.33 sq. ft.) Min. 11/2" InsulBase Polyiso 4" ribbons of FAST 1165 Min. 1/2" DensDeck Prime or Securock Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.) Min. 11/2" InsulBase Polyiso FAST 190 Steel Deck (Min. 22 Gauge)/VapAir Seal 725TR with CavGrip Primer 16 (2 sq. ft.) Min. 11/2" InsulBase Polyiso FAST 1105 35205700 Concrete Deck Min. 1/2" InsulBase Polyiso Full Coverage FAST 1315 27965400 27965600 27970500 Min. 11/2" InsulBase Polyiso FAST 1480 Min. 1/2" InsulBase Polyiso 22269800 22269800 22269800 1315 27965400 27965600 27970500 Min. 1/2" InsulBase Polyiso Hot Asphalt 1315 27965400 27965600 27970500 Concrete Deck/VapAir Seal 725TR with CavGrip Primer, Carlisle 702 LV Primer or Carlisle 702 Primer Min. 11/2" InsulBase Polyiso FAST 1255 CavGrip 1195 702 LV 190 702 27536100 27536100 27536100 Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/CutBack Asphalt Primer Min. 1/2" InsulBase Polyiso FAST Min. 11/2" InsulBase Polyiso FAST 1330 Tectum Deck Min. 11/2" InsulBase Polyiso 16 (2 sq. ft) 190 9341800 9530000 9341900 Min. 2" InsulBase Polyiso FullCoverage FAST 1150 21168800 22489600 22489800 Min. 11/2" InsulBase Polyiso 190 600163 SW Codes Page 25 of 44 01/2017

InsulBase Polyiso s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer Gypsum Deck TearOff or Spectro Weld Sure Weld HS Min. 2" InsulBase Polyiso 8 (4 sq. ft) 190 9342300 9530900 Min. 11/2" InsulBase Polyiso FullCoverage FAST 190 14420300 14420200 14420400 Min. 1" InsulBase Polyiso 190 18974400 18974500 18974600 Cellular Lightweight Insulating Concrete/Steel Decking (Min. 22 Gauge) Min. 11/2" InsulBase Polyiso 16 (2 sq. ft) 190 Min. 2" InsulBase Polyiso 8 (4 sq. ft) 190 Min. 2" InsulBase Polyiso 20 (1.6 sq. ft) 1150 Celcore Min. 1" InsulBase Polyiso 4" ribbons of FAST 1135 Cellular Lightweight Insulating Concrete/Concrete Decking Celcore 3093980 194470 Min. 1" InsulBase Polyiso 4" ribbons of FAST 1135 309997050916 Elastizell 3094060 194470 3100020 50916 3094970 194470 3100520 50916 Min. 1" InsulBase Polyiso tapered 1180 93280050936 961220 50936 932830 50936 600163 SW Codes Page 26 of 44 01/2017

InsulBase Polyiso s Recover.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer or SpectroWeld HS Steel Deck (Min. 22 Gauge) 1" InsulBase Polyiso 20 (1.6 sq. ft) 190 16468500 16468700 16469500 1" InsulBase Polyiso 6" ribbons of FAST 190 Min. 1/2" InsulBase Polyiso 190 27892200 27892300 27892500 Concrete Deck 1/2" InsulBase Polyiso FAST 190 Tectum Deck 1" InsulBase Polyiso 20 (1.6 sq. ft) 190 1" InsulBase Polyiso FullCoverage FAST 1150 1" InsulBase Polyiso 190 Gypsum Deck TearOff 1" InsulBase Polyiso 20 (1.6 sq. ft) 190 1" InsulBase Polyiso FullCoverage FAST 190 1" InsulBase Polyiso 190 600163 SW Codes Page 27 of 44 01/2017

SecurShield and s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer Steel Deck (Min. 22 Gauge) or Spectro Weld HS Min. 11/2" SecurShield or 16 (2 sq. ft) 190 18856900 18856900 18856900 Min. 2" SecurShield or 8 (4 sq. ft) 190 18887000 18887000 18887000 Min. 2" SecurShield or 20 (1.6 sq. ft.) 1150 13547600 13547600 13547600 Min. 2" SecurShield Only 32 (1 sq. ft.) 1225 (35) 24551300 24550900 24551600 Min. 11/2" InsulBase Polyiso 10 (3.2 sq. ft.) Min. 11/2" SecurShield or FAST 190 Min. 2" InsulBase Polyiso or SecurShield 8 (4 sq. ft) Min. 2" SecurShield or FAST 190 25463000 25463000 25463000 Min. 11/2" InsulBase Polyiso 18 (1.8 sq. ft.) Min. 11/2" SecurShield or 6" ribbons of FAST 1105 Min. 11/2" InsulBase Polyiso 24 (1.33 sq. ft.) Min. 11/2" SecurShield or 4" ribbons of FAST 1165 Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.) Min. 11/2" SecurShield or 6" ribbons of FAST 190 Steel Deck (Min. 22 Gauge)/VapAir Seal 725TR with CavGrip Primer Min. 1/2" DensDeck Prime or 5/8" of Securock 16 (2 sq. ft.) Min. 11/2" SecurShield or FAST 1105 35205700 Concrete Deck Min. 1/2" InsulBase Polyiso FAST Min. 2" SecurShield or FAST 1225 32365500 Min. 2" SecurShield or 1240 Min. 2" SecurShield or Hot Asphalt 1300 Concrete Deck/VapAir Seal 725TR with CavGrip Primer, Carlisle 702 LV Primer or Carlisle 702 Primer 1255 CavGrip Min. 1/2" SecurShield or FAST 1195 702 LV 190 702 600163 SW Codes Page 28 of 44 01/2017

SecurShield and s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer or Spectro Weld HS Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/CutBack Asphalt Primer Min. 1/2" InsulBase Polyiso FAST Min. 2" SecurShield or FAST 1330 Tectum Deck Min. 11/2" SecurShield or Min. 11/2" SecurShield or 16 (2 sq. ft) 190 FullCoverage FAST 1150 Min. 11/2" SecurShield or 190 Gypsum Deck TearOff Min. 11/2" SecurShield or Min. 11/2" SecurShield or 16 (2 sq. ft) 190 FullCoverage FAST 190 Min. 11/2" SecurShield or 190 Cellular Lightweight Insulating Concrete/Steel Decking (Min. 22 Gauge) Min. 11/2" SecurShield or Min. 2" SecurShield or Min. 2" SecurShield or Min. 2" SecurShield or Min. 11/2" SecurShield or 16 (2 sq. ft) 175 8 (4 sq. ft) 190 20 (1.6 sq. ft.) 1150 32 (1 sq. ft.) 1225 4" ribbons of FAST 1135 (Celcore) Cellular Lightweight Insulating Concrete/Concrete Decking Min. 1/2" SecurShield or 4" ribbons of FAST 1135 600163 SW Codes Page 29 of 44 01/2017

SecurShield s Recover.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Base and Top Layer Adhesive: Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base Insulation Layer Base Layer Fastening Top Insulation Layer or SpectroWeld HS Steel Deck (Min. 22 Gauge) 1" SecurShield 20 (1.6 sq. ft) 190 Concrete Deck 1/2" SecurShield FAST 190 Tectum Deck 1" SecurShield 20 (1.6 sq. ft) 190 1" SecurShield FullCoverage FAST 1150 1" SecurShield 190 Gypsum Deck TearOff 1" SecurShield 20 (1.6 sq. ft) 190 1" SecurShield FullCoverage FAST 190 1" SecurShield 190 600163 SW Codes Page 30 of 44 01/2017

Securock s New Construction.045 or.060 Standard Reinforced Membrane (White, Gray or Tan).045 or.060 HS Reinforced Membrane (White, Gray or Tan).080 Reinforced Membrane (White, Gray or Tan) Bonding Adhesive (SWBA) or Low VOC Bonding Adhesive (LVOC) Base and Top Layer Adhesive: Base Insulation Layer Base Layer Fastening Top Insulation Layer or SpectroWeld HS Steel Deck (Min. 22 Gauge) Min. 11/2" InsulBase Polyiso Loose laid Min. 1/4" Securock 12 (2.66 sq. ft) 175 26996200 26996400 26996800 Min. 11/2" InsulBase Polyiso Loose laid Min. 1/4" Securock Min. 11/2" InsulBase Polyiso Loose laid Min. 3/8" Securock 10 (3.2 sq. ft) SecurFAST Plate 8 (4 sq. ft) SureFAST Plate 190 190 Min. 11/2" InsulBase Polyiso Loose laid Min. 1/2" Securock 10 (3.2 sq. ft) 190 26998500 26998600 26998800 Min. 11/2" InsulBase Polyiso Loose laid Min. 1/2" Securock Min. 11/2" InsulBase Polyiso Loose laid Min. 1/2" Securock 8 (4 sq. ft) SecurFAST Plate 6 (5.33 sq. ft) SecurFAST Plate 190 175 Min. 11/2" InsulBase Polyiso Loose laid Min. 5/8" Securock 8 (4 sq. ft) 190 Min. 11/2" InsulBase Polyiso Loose laid Min. 5/8" Securock 6 (5.33 sq. ft) SecurFAST Plate 26998900 26999000 26999200 190 Min. 1" InsulBase Polyiso Loose laid Min. 1/2" Securock 20 (1.6 sq. ft) 1150 26999300 26999400 26999600 Min. 11/2" InsulBase Polyiso Loose laid Min. 1/2" Securock 32 (1 sq. ft) 1255 23927100 23927200 26995200 Min. 11/2" InsulBase Polyiso 10 (3.2 sq. ft.) Min. 1/4" Securock FAST 190 30175000 30175300 Min. 2" InsulBase Polyiso 8 (4 sq. ft) Min. 1/4" Securock FAST 190 Min. 11/2" InsulBase Polyiso 18 (1.8 sq. ft.) Min. 1/4" Securock 6" ribbons of FAST or Dual Tank 1105 Min. 11/2" InsulBase Polyiso 24 (1.33 sq. ft.) Min. 1/4" Securock 4" ribbons of FAST 1165 Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.) Min. 1/4" Securock over Min. 1/2" InsulBase Polyiso FAST 1105 Steel Deck (Min. 22 Gauge)/VapAir Seal 725TR with CavGrip Primer Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.) Min. 1/4" Securock over Min. 1/2" InsulBase Polyiso FAST 190 32759700 Concrete Deck Min. 1/2" InsulBase Polyiso FAST Full Coverage Min. 1/4" Securock FAST Full Coverage 1315 30766200 30775100 30770200 Min. 11/2" InsulBase Polyiso Min. 1/4" Securock 1240 30174700 30175500 30176100 Min. 1/2" InsulBase Polyiso Hot Asphalt Min. 1/4" Securock Hot Asphalt 1300 600163 SW Codes Page 31 of 44 01/2017