Designing Glass to Resist Wind and Snow Loads

Similar documents
TECHNICAL BULLETIN TB-1800-XX. Unsupported Edge Conditions of Insulating Glass Units

Condensation on Indoor Glass Surface

Heat Treated Glass for Architectural Glazing

Spandrel Glass Types and Recommendations

Point-Supported Glazing

STRUCTURAL DESIGN & PROGRESSIVE COLLAPSE

Glass Breakage Failure Mode and Stress Estimation

OPACI-COAT Water-base Silicone Glass Coating

for more information call or go to zeledyne.com

Point Supported Glazing

Thermal Stress Update

JE Berkowitz, L.P. Architectural Glazing Guide Specification for Enviroscreen Silk-Screened Glass

Series B450 Guide Specification

Heat Treated Glass for Architectural Glazing

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

NZS :2008. Glazing in buildings NZS :2008. Part 4: Wind, dead, snow, and live actions. New Zealand Standard

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL

JONES AIRWAYS, LLC CLEVELAND REGIONAL JETPORT SECTION GLAZING

Prepared for: Jockimo Inc. projects

2000 Skylight. For specific product applications, Consult your Kawneer representative. JANUARY, 2017 EC FEATURES ADMF020EN

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

Standard Test Method for Drop-Weight Tear Tests of Ferritic Steels 1

ZIP System Sheathing Load-Span Tables

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

Standard Test Method for Measuring Compressive Properties of Thermal Insulations 1

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications 1

Repair Maintenance Hangar Phase II August 2010

Laminating Division Technical Committee. Superwide Laminates and ASTM C1172

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

PRODUCT TECHNICAL DATA Saflex Storm (VSO2) Composite PVB Interlayer

TEST REPORT ASTM E331. Report No.: E Rendered to: IMISON USA Houston, Texas

2003 INTERNATIONAL BUILDING CODE 521

Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks 1

GLASS DESIGN GUIDELINES

Precast Concrete Bearing Wall Panel Design (Alternative Analysis Method) (Using ACI )

CHAPTER 24 GLASS AND GLAZING

SILVER LINE BUILDING PRODUCTS

Multi-Cavity Insulating Glass Units

Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement 1

Architectural Specification Manual

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

Metal Panel & Spandrel Glass Design Guidelines

3 Specification 3.1 Dimensions Lites of overall dimensions ( x ) inches / mm.

OPACI-COAT Water-base Silicone Glass Coating

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Edge Grinding: Safety vs. Aesthetics. Fall Conference. Las Vegas, NV September 11, 2018

Edge Grinding: Safety vs. Aesthetics. Fall Conference Las Vegas, NV September 11, /24/2018

Series x Thermal Triple Set Storefront Framing

EASTERN ARCHITECTURAL SYSTEMS SERIES HRP 1000F HORIZONTAL ROLLER - LMI

BLAST PERFORMANCE OF NON-CAPTURED STRUCTURALLY GLAZED INSULATED GLASS UNITS SAMUEL POND, P.E. + JAMES CASPER, S.E., P.E.


ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

ADVANCED FRAMING LUMBER

SECTION ALUMINUM STORM WINDOWS

AdvanTech Sheathing and Subfloor Panels

PG 123 TM Framing 1. Optional Features Optional vertical covers 1/4" (6.4) infill adaptors

Designation: TTU NWI DIF Air Bladder Standard Scope

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to:

Linings of Aboveground Petroleum Storage Tank Bottoms API RECOMMENDED PRACTICE 652 FOURTH EDITION, SEPTEMBER 2014

Series x Thermal Triple Set Storefront Framing

Corium Brick Rainscreen System Specifications

Design of Reinforced Concrete Slabs

Architectural Specification Manual 45 mm System

Steel Pipelines Crossing Railroads and Highways

Blast Loading For Glazing

SECTION ALUMINUM STORM WINDOWS

SOUTH AFRICAN NATIONAL STANDARD

DEFLECTION AND WIND LOADS

PR-L274 Nordic Structures Revised April 16, 2017

EC-250 AAMA Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System

Impact-Resistant Entrances

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A AAMA TEST REPORT SUMMARY

Standard Test Method of Measuring Shrinkage from Mold Dimensions of Thermoplastics 1

Standard Test Method for Calibration of Atmospheric Corrosion Test Chambers by Change in Mass of Copper Coupons 1

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

International Beams Revised June 15, 2018

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

VARIOUS TYPES OF SLABS

SECTION DYNAMIC GLAZING PART 1 - GENERAL 1.1 SUMMARY

Standard Specification for Stainless Chromium-Nickel Steel-Clad Plate 1

Challenges of Bent Insulating Glass

May 15 PERSPEX. For glazing. Perspex Data Sheet. Allplastics PTY LTD Unit 20, 380 Eastern Valley Way Chatswood NSW 2067

SECTION SPECIAL FUNCTION GLAZING

INSULATED METAL WALL PANEL HORIZONTAL APPLICATION TECHNICAL BULLETIN PIONEERING INSULATED METAL PANEL TECHNOLOGY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

System Thermal Clip Storefront System

AMERICAN NATIONAL STANDARD ANSI/NAAMM STANDARD. Maximum Bearing Bar Depth / 2 (63.5 mm)

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

Standard Specification for UNS N08020, UNS N08024, and UNS N08026 Nickel Alloy Bar and Wire 1

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: LEED HIMMEL INDUSTRIES, INC. Hamden, Connecticut

Warmboard-S Radiant-Floor Heating Panels PR-V180 Warmboard, Inc. Revised February 19, 2018

Standard Test Method for Obtaining and Testing Drilled Cores of Shotcrete 1

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Transcription:

One of the design requirements of glass used in buildings is to resist the loads created by wind and snow. ASTM E1300-02: Standard Practice for Determining Load Resistance of Glass in Buildings provides numerical and graphical procedures to help design professionals and other specifying authorities determine the appropriate glass thickness and type to meet specified wind and snow loads. The E1300 standard has been developed by a broad group of industry representatives and has evolved and expanded to its present form over a period of more than 10 years. E1300 does not address glass design issues related to thermal stress, for which we invite our customers to use Vitro s (formerly PPG Industries) Thermal Stress Update publication and related software tool. The purpose of this document is to familiarize Vitro s customers with this standard, including its scope and limitations. Examples are shown and directions on obtaining a copy of the standard are given. Also, directions are given on how to obtain a software package, based on ASTM E1300-02,that can be used to produce compatible recommendations. Examples from the software package are also shown. Scope of E1300-02 E1300-02 includes procedures that address: Monolithic, laminated, and insulating glass constructions. Insulating glass units can have lites of same or different types and thickness. Insulating glass units can have one monolithic lite and one laminated lite, or can be comprised of two laminated lites. 1, 2, 3, and 4 sides supported conditions. Short or long duration uniform lateral loads. Calculated center-of-glass deflection. Specified probabilities of glass breakage. Glass Products NOT Covered Wired glass. Patterned glass. Etched, sandblasted, drilled, notched or grooved glass. Assumptions The procedures defined by ASTM E1300-02 include the following assumptions. Glass is properly glazed and free of edge damage. Glass has not been subjected to abuse. Surface condition of the glass is typical of in-service glass. Glass edge support limits the lateral deflections of the supported glass edges to less than 1/175 of their lengths. Center of glass deflection will not result in loss of edge support. Vitro encourages its customers to purchase a copy of the ASTM E 1300-02 standard. Copies may be purchased on line at www.astm.org. Vitro Architectural Glass PAGE 1 OF 12

Using E1300-02 KEY CONCEPTS Glass Type Factor multiplying factor for adjusting the load resistance of different glass types. Specified Design Load magnitude (in kpa or lb/sq. ft.), type of load (wind or snow), and duration of the load given by the specifying authority. Nonfactored Load 3-second uniform load associated with a probability of glass breakage of 8 lites per 1,000. Load Share Factor multiplying factor derived from the load sharing between the two lites of equal or different types and thickness. Load Resistance the uniform lateral load that a glass construction can sustain based upon a probability of breakage and load duration. DESIGN PROCEDURE 1. Start with glass dimensions and specified design loading. Design load must be in psf or kpa. Wind velocity can be converted to psf as follows: Psf = 0.00256V 2 2. Formulate a trial design (glass thickness and type). 3. Use E 1300 to determine the load resistance (LR) and center of glass deflection. 4. If LR is greater than the specified design loading, then trial design is OK and you are done. 5. If LR is less than the specified design loading, then modify the trial glazing configuration and return to step 3. Note: For insulating glass units, compute the load resistance for each lite. The load resistance of the unit is the minimum of the two. Insulating Glass Unit Design Example Determine the glass thickness and glass types for an insulating glass unit with rectangular dimensions of 60 in. x 96 in. that is simply supported on all four edges. The 3-second duration design loading is 125 psf. 1. Trial Design Outboard Lite (#1): Nominal ¼ in. heat strengthened monolithic glass. Inboard Lite (#2): Nominal 3/8 in. heat strengthened laminated glass. 2. Determine the load resistance based on Lite #1. Use the nonfactored load chart for ¼ in. glass (See Fig. 1 on page 3). Thus, the nonfactored load for lite #1 (NFL1) is 28.8 psf. Note: You must interpolate between curves Vitro Architectural Glass PAGE 2 OF 12

FIGURE 1 (Ref. Fig. A1.6 in ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Plate Length (in.) 0 50 100 150 200 Plate Width (in.) 140 120 100 80 60 40 20 6.0 mm (1/4 in.) Glass Nonfactored Load Four Sides Simply Supported P b = 0.008 1 kpa = 20.9 psf 3-Second Duration 4.00 5.00 7.00 10.0 2.50 3.00 2.00 1.50 1.25 1.00 0.75 0.50 3000 2000 1000 Plate Width (mm) 0 0 0 1000 2000 3000 4000 5000 Plate Length (mm) 3. Determine the Glass Type Factor for Lite #1 (GTF1) from Table 2 (reproduced below). Thus, GTF1 = 1.8 TABLE 2 Glass Type Factors (GTF) for Insulating Glass Short Duration Load Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Lite No. 1 Monolithic Glass or Laminated Glass Type Lite No. 2 Monolithic Glass or Laminated Glass Type AN HS FT GTF1 GTF2 GTF1 GTF2 GTF2 GTF2 AN 0.9 0.9 1.0 1.9 1.0 3.8 HS 1.9 1.0 1.8 1.8 1.9 3.8 FT 3.8 1.0 3.88 1.9 3.6 3.6 Vitro Architectural Glass PAGE 3 OF 12

4. Determine the Load Share Factor for Lite #1 (LSF1) from Table 5 on page 6. Thus, LSF1 = 5.26 5. Calculate the Load Resistance (based on Lite #1): LR1 = NFL1 x GTF1 x LSF1 = 28.8 x 1.8 x 5.26 = 273 psf This meets the requirements, but you must check lite #2. 6. Determine the load resistance based on lite #2. Use the nonfactored load chart for 3/8 in. laminated glass (See Fig. 2 on page 6). Thus, the nonfactored load for lite #2 (NFL2) is 49.2 psf. 7. Determine the Glass Type Factor for Lite #2 (GTF2) from Table 2 (p. 3) Thus, GTF2 = 1.8 8. Determine the Load Share Factor for Lite #2 (LSF2) from Table 5 (p. 6) Thus, LSF2 = 1.23 9. Calculate the Load Resistance (based on Lite #2): LR2 = NFL2 x GTF2 x LSF2 = 49.2 x 1.8 x 1.23 = 109 psf This does not meet the requirements and therefore this trial design is not adequate. It is necessary to modify the glass thickness and/or types and perform another iteration of the process. 10. Modified Trial Design Outboard Lite (#1): Nominal 3/8 in. heat strengthened monolithic glass. Inboard Lite (#2): Nominal 5/16 in. heat strengthened laminated glass. 12. Determine the load resistance based on Lite #1. Use the nonfactored load chart for 3/8 in. glass (See Fig. 3 on page 7). Thus, the nonfactored load for lite #1 (NFL1) is 47.0 psf. 13. Determine the Glass Type Factor for lite #1 (GTF1) from Table 2 (p. 3). Thus, GTF1 = 1.8 14. Determine the Load Share Factor for lite #1 (LSF1) from Table 5 (p. 4). Thus, LSF1 = 1.56 15. Calculate the Load Resistance (based on lite #1): LR1 = NFL1 x GTF1 x LSF1 = 47.0 x 1.8 x 1.56 = 132 psf This meets the requirements, but you must check lite #2. Vitro Architectural Glass PAGE 4 OF 12

16. Determine the load resistance based on lite #2. Use the nonfactored load chart for 5/16 in. laminated glass (See Figure 4 on page 7). Thus, the nonfactored load for lite #2 (NFL2) is 40.8 psf. 17. Determine the Glass Type Factor for lite #2 (GTF2 from Table 2 (p. 3) Thus, GTF2 = 1.8 18. Determine the Load Share Factor for lite #2 (LSF2) from Table 5 (p. 6) Thus, LSF2 = 2.80 19. Calculate the Load Resistance (based on lite #2): LR2 = NFL2 x GTF2 x LSF2 = 40.8 x 1.8 x 2.80 = 205 psf This meets the requirements. Since the load resistance of both Lite 1 and Lite 2 meet the requirement, this trial design is adequate. Vitro Architectural Glass PAGE 5 OF 12

TABLE 5 Load Share (LS) Factors for Insulating Glass Units Note: This reproduction represents only a portion of Table 5 as shown in ASTM E 1300-02 Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Lite No.1 Lite No. 2 Monolithic glass, Short or Long Duration Load or Monolithic Glass Laminated Glass, Short Duration Load Only Nominal Thickness (in.) 1/4 5/16 3/8 LS1 LS2 LS1 LS2 LS1 LS2 1/4 2.00 2.00 3.37 1.42 5.26 1.23 5/16 1.42 3.37 2.00 2.00 2.80 1.56 3/8 1.23 5.26 1.56 2.80 2.00 2.00 FIGURE 2 (Ref. Fig. A1.30 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Vitro Architectural Glass PAGE 6 OF 12

FIGURE 3 (Ref. Fig. A1.8 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Plate Length (in.) 0 50 100 150 200 Plate Width (in.) 140 120 100 80 60 40 10.0 mm (3/8 in.) Glass Nonfactored Load Four Sides Simply Supported P b = 0.008 1 kpa = 20.9 psf 3-Second Duration 7.00 10.0 4.00 5.00 3.00 2.50 2.00 1.50 1.25 1.00 0.75 3000 2000 1000 Plate Width (mm) 20 0 0 0 1000 2000 3000 4000 5000 Plate Length (mm) FIGURE 4 (Ref. Fig. A1.29 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Vitro Architectural Glass PAGE 7 OF 12

Center-of Glass Deflection ASTM E 1300-02 includes procedures for calculating the center-of-glass deflection. An example of this calculation, using the above design example, the procedure is as follows. 1. Calculate the center-of-glass deflection for lite #1 under the specified design load. Load carried by lite #1 (P1): P1 = Specified Load /LSF1 = 125 psf/1.56 = 80.1 psf Aspect Ratio (AR) = long dimension /short dimension = 96 in./60 in. = 1.6 Load * Area 2 = = 80.1 psf * (40 sq. ft.) 2 = 128,160 pounds-ft 2 = 128 kip-ft 2 Using Figure 5 on page 9: Project a vertical line (shown in red) from 128 kip-ft 2 along the horizontal axis. Project a horizontal line (shown in green) from the intersection of the vertical line with the curved line for Aspect Ratio = 1.6 (determined by interpolation between curved lines for AR =1 and AR =2). 1. The approximate center-of-glass deflection is then determined by the intersection of the horizontal (green) line with the vertical axes as 0.89 in. 2. Calculate the center-of-glass deflection for lite #2 under the specified design load. Load carried by lite #2 (P2): P1 = Specified Load /LSF2 = 125 psf/2.80 = 44.7 psf Aspect Ratio (AR) = long dimension /short dimension = 96 in./60 in. = 1.6 Load * Area 2 = = 44.7 psf * (40 sq. ft.) 2 = 71,520 pounds-ft 2 = 71.5 kip-ft 2 Using Figure 6 on page 9: Project a vertical line (shown in red) from 71.5 kip-ft 2 along the horizontal axis. Project a horizontal line (shown in green) from the intersection of the vertical line with the curved line for Aspect Ratio = 1.6 (determined by interpolation between curved lines for AR =1 and AR =2). 3. The approximate center-of-glass deflection is then determined by the intersection of the horizontal (green) line with the vertical axes as 0.83 in. 4. The approximate center deflection of the insulating glass unit is the larger of the calculated center-of-glass deflections for lite 1 and lite 2. Thus the approximate center-of-glass deflection would be 0.89 in Vitro Architectural Glass PAGE 8 OF 12

FIGURE 5 (Ref. Fig. A1.8 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA FIGURE 6 (Ref. Fig. A1.29 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Vitro Architectural Glass PAGE 9 OF 12

Computer Based Version Computer software, created by the Standards Design Group, is available that generates results that are consistent with ASTM E 1300-02. The software is easy to use and reasonably priced. Using the software is obviously much quicker and greatly reduces the chance for error that can result from the tedious manual procedure. Vitro encourages its customers to investigate this software through the Standards Design Group Website, www.standardsdesign.com Examples of input and output screens, based on the previous manual example are given here for reference. Window Glass Design Software Modified Trial Design Input Screen SI Units Reproduced, with permission, from Standard Designs Group Comprehensive Window Glass Design Plus Vitro Architectural Glass PAGE 10 OF 12

Window Glass Design Software Modified Trial Design Results Screen (SI Units) Reproduced, with permission, from Standard Designs Group Comprehensive Window Glass Design Plus Window Design Group Software Modified Trial Design Details Screen (SI Units) Reproduced, with permission, from Standard Designs Group Comprehensive Window Glass Design Plus Vitro Architectural Glass PAGE 11 OF 12

HISTORY TABLE ITEM DATE DESCRIPTION Original Publication 4/2/2003 TD-134 Revision 1 2016-10-04 Updated to Vitro logo and format This document is intended to inform and assist the reader in the application, use, and maintenance of Vitro Flat Glass products. Actual performance and results can vary depending on the circumstances. Vitro makes no warranty or guarantee as to the results to be obtained from the use of all or any portion of the information provided herein, and hereby disclaims any liability for personal injury, property damage, product insufficiency, or any other damages of any kind or nature arising from the reader's use of the information contained herein. Vitro Architectural Glass PAGE 12 OF 12