Structural health monitoring of structures repaired with FRP

Similar documents
Shear strengthening of RC deep beams with circular openings using externally bonded SFRP composites

International Journal of Advance Research in Engineering, Science & Technology

AFRP retrofitting of RC structures in Japan

Effects Of Slenderness Ratio In RC Slender Column Using GFRP And CFRP Confinement

Impact Resistance of Shear-strengthened RC Beams with Sprayed GFRP

COMPARATIVE STUDY OF BEAMS BY USING DIFFERENT TYPES OF RETROFITING TECHNIQUES

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Flexural and Shear Strengthening Of RC beams with FRP-An Experimental Study

BRIDGE REHABILITATION USING FRP- CASE STUDIES PEDRAM MOJARRAD SIKA AUSTRALIA

REFURBISHMENT STRUCTURAL STRENGTHENING WITH SIKA SYSTEMS

Carbon Fibre Textile

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

INNOVATIVE FIBRE REINFORCED BRIDGE DECK MODULES ABSTRACT

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

DETERMINATION OF ULTIMATE FLEXTURAL CAPACITY OF STRENGTHENED BEAMS WITH STEEL PLATES AND GFRP INTRODUCTION

STRUCTURAL STRENGTHENING WITH FRP AYDIN KHAJEPUR SIKA PARSIAN, TM REFURBISHMENT

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

Flexural Behavior of Concrete Beam Reinforced with Steel and FRP Re-bars

DURABILITY PERFORMANCE OF EPOXY INJECTED REINFORCED CONCRETE BEAMS WITH AND WITHOUT FRP FABRICS

2. EXPERIMENTAL PROGRAME

Strengthening of Beams Using Glass Fiber Reinforced Polymer (GFRP) Laminate

SikaWrap. Composite Fabrics for Structural and Seismic Strengthening. Solutions with Sika Systems. Hybrid fiber fabrics. Glass fiber fabrics

Repair and upgrading of concrete structures with FRP materials

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

The Fundamentals for Fiber-Reinforced Polymer (FRP) Strengthening

Debonding Behavior of Skew FRP-Bonded Concrete Joints

Strengthening of Reinforced Concrete Building by Externally Bonded Carbon Fiber System

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

Carder 1. FABRICATION AND CYCLIC LOADING OF SUPER-ELASTIC SHAPE MEMORY ALLOY REINFORCED POLYMER Rachel Carder

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

Table of content of printouts:

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

STRENGTHENING EFFECTS OF CONCRETE FLEXURAL MEMBERS RETROFITTED WITH HYBRID FRP COMPOSITES. Abstract. Introduction

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

Study on Strengthening of RC Slabs with Different Innovative Techniques

Flexural Behaviour of Composite Girders Using FRP and Precast Ultra-High-Strength Fiber-Reinforced Concrete Slabs

Strategy for the Rehabilitation of R/C T Beam Bridges with Carbon Fiber Reinforced Polymer Sheets

FLEXURAL RESPONSE OF FRC BEAMS WITH EXTERNAL GFRP LAMINATES

Strengthening of Timber Bridges

Use of Externally Bonded FRP Systems for Rehabilitation of Bridges in Western Canada

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

INNOVATIVE ASSET MANAGEMENT. Research Project C. Challenges in Keeping Bridges in Good Operation Condition

BEHAVIOR OF FRP SANDWICH PANELS FOR TRANSPORTATION INFRASTRUCTURE

Repairing of RC T-Section Beams with Opening by CFRP for Cracks and Ultimate Torque

Confining Concrete Columns with FRP Materials

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

Rehabilitation of East Lynn Lake Bridge Steel Pile Bents With Composites

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

I MATERIALI COMPOSITI PER L INGEGNERIA CIVILE. FRP Introduzione alle tecniche di rinforzo 1

2.0 REVIEW OF LITERATURE. In the last few years, the use of fiber-reinforced plastic (FRP) rebars to replace steel

FIBER REINFORCED CEMENT BASED COMPOSITE SHEETS FOR STRUCTURAL RETROFIT

The Use of Sustainable Materials for Quick Repair of Aging Bridges

Numerical Study on Behaviour of Concrete Filled Tubes (CFT) under Static Load

Effect of Near Surface Mounted (NSM) Steel Bars on Shear Strength of RC Beams

Strengthening Reinforced Concrete Beams Using Hybrid FRP Laminates

FRP STRENGTHENING OF 60 YEAR OLD PRE-STRESSED CONCRETE BRIDGE DECK UNITS

A STUDY ON STRENGTHENING OF HOLLOW STEEL SECTION BY USING CFRP AND AFRP

NDE of FRP Bridge Decks and Beams

Experimental study of Axially Loaded Retrofitted Concrete Short Column

Strengthening of RCC Beams with FRP

Investigating affecting angle changes of polymeric carbon fibers on the behavior of reinforced FRP steel shear wall

CHAPTER 2 REVIEW OF LITERATURE 2.1 Introduction Reinforced concrete beam-column joints have an important function in the structural concept of many

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

Experimental Study on Strengthening of RCC Slab by using CFRP & GFRP Sheets

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] ISSN: VOLUME 5, ISSUE

DEVELOPMENT OF ANCHORAGE SYSTEM FOR CFRP SHEET IN STRENGTHENING OF REINFORCED CONCRETE STRUCTURES

APPLICATION OF EXPANSIVE AGENT (EA) TO PRODUCE POST TENSIONING FORCE IN FRP JACKETS FOR LATERAL RETROFITTING OF RC COLUMNS

Table of content of printouts:

BEHAVIOR OF FULL-SCALE SHEAR DEFICIENT CORNER RC BEAM-COLUMN CONNECTIONS RETROFITTED WITH CFRP SHEETS

Fiber Reinforced Polymer Repair Techniques for Reinforced concrete Beams Pre-Damaged in Shear

A STUDY ON THE BEHAVIOUR OF RC BEAMS RETROFITTED USING CFRP LAMINATES UNDER SINGLE POINT LOADING

1. Bridge damage due to earthquake

FIRE RESISTANCE BEHAVIOUR OF FRP REINFORCEDCONCRETE SLABS: RESULTS OF THE FIRST FIRE TEST (PROGRESS REPORT-I)

Civil Engineering Division Enppi

COMPRESSION BEHAVIOR OF CIRCULAR AND RECTANGULAR RC COLUMNS RETROFITTED BY GFRP LAMINATES: AN EXPERIMENTAL STUDY

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

Shear Strengthening Effects with Varying Types of FRP Materials and Strengthening Methods

DESIGN GUIDELINES FOR BRIDGE DECK SLABS REINFORCED by CFRP and GFRP

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

Prequalification Requirements for FRP Systems in Civil Structures A Review of Current Worldwide Programs

Extreme Loading for Structures Version 3.1

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

Annette Harte (NUI Galway) Kay Uwe Schober (is Mainz) COST Action FP1101, WG2 Workshop Telč

Enhancing the Compressive Strength of Square Cross Sectional Column Using FRP Material

Analysis of Concrete Filled Double Skin Steel Tube (CFDST) column with CFRP wrapping

Retrofitting methods

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

Analytical study of a 2-span reinforced concrete beam strengthened with fibre reinforced polymer

CFRP CONCRETE PROTECTION AND STRENGTHENING

Strengthening of RCC Column Using Glass Fibre Reinforced Polymer (GFRP)

Effect of fiber fatigue rupture on bridging stress degradation in fiber reinforced cementitious composites

ASSESSMENT AND SEISMIC RETROFITTING OF R.C BUILDING FOR ADDITIONAL FLOORS 1Dr.R.Madheswaran, 2 Isac.T

QuakeWrap s PileMedic System November 30, 2010

. Numerical study on strengthening composite bridges

Bond characteristics between steel and CFRP laminate under impact loads

Strengthening of RC Beams subjected to Combined Torsion and Bending with GFRP Composites

CYCLIC RESPONSE OF RC HOLLOW BOX BRIDGE COLUMNS STRENGTHENED USING CFRP AND RC JACKETING

Retrofitting of Reinforced Concrete Beam with Externally Bonded CFRP

Transcription:

Structural Studies, Repairs and Maintenance of Heritage Architecture IX 567 Structural health monitoring of structures repaired with FRP Y. Khalighi Department of Civil Engineering, The University of British Columbia, Canada Abstract Sprayed FRP is a novel method developed at the University of British Columbia which has been very successful in repairing damaged structures is Sprayed FRP. The key to a successful and optimal usage of FRP in strengthening and rehabilitation is in our ability to understand and effectively engineer Substrate- FRP bond. In this paper, performance of FRP as a repair material is studied by structural monitoring of the substrate and the FRP sprayed patch. In this study, 35x10x10 cm concrete beams are sprayed with FRP and tested under four- point loading. The substrate and repair material response to loading is monitored using strain gauges carefully installed at different locations of the structure. Ten 10-mm one-directional and two bi-directional strain gauges are used. Data is obtained using data acquisition machine and converter software. The load-stain curves for the strain gauges are graphed. The measurements at the gauges located at the same level are compared and strain divergence is discussed. Possible approaches are discussed to model the gradual process of bond interface. This is the basis for a comprehensive damage model capable of predicting the performance of repaired structures under various static and earthquake loading. A field performance of these repairs will also be discussed. The case study is a bridge in Victoria, British Columbia, which was repaired by sprayed FRP and has been monitored over the past three years by the materials group of UBC under Dr. Banthia s leadership. Keywords: fibre reinforced polymer, concrete, structural health monitoring, bond, sprayed FRP.

568 Structural Studies, Repairs and Maintenance of Heritage Architecture IX 1 Introduction Infrastructure deterioration has been a global crisis in the recent decade. In the United States alone there are more than 200,000 deficient bridges, and there are approximately 30,000 in Canada. 150 to 200 spans fail each year, sometimes with tragic consequences. The cost of strengthening or repairing the 30,000 deficient bridges in Canada is about $44 billion. It will take $5 billion to rehabilitate the 5,000 parking garages that are in a state of utter disrepair. The most common method for repair/strengthening has been to externally bond steel plates to the structure, but lately, fiber reinforced polymers (FRPs) are slowly replacing steel in these applications owing to their superior properties such as a high strength to weight ratio and excellent resistance to corrosion. Fiber reinforced polymers (FRPs) consist of high-strength fibers (carbon, glass, or aramid) embedded in a polymeric matrix (epoxy, vinylester, etc). They have been largely used in new construction and repair and rehabilitation of existing structures. Figure 1 shows an application of FRP in repairing Sins Bridge, Switzerland. FRP can be used as a confining material in columns to increase the load bearing capacity. It is also utilized in flexural and shear strengthening. Repairs with FRP could restore or even increase the ultimate failure capacity or could just simply be used for aesthetic purposes. Figure 2 shows the concept of shear and flexural strengthening by fiber reinforced polymer. Figure 1: FRP repair in Sins Bridge, Switzerland [1]. Figure 2: Left: CFRP (Sika Carbodur) flexural reinforcement, Right: CFRP (Sika Carbodur) shear reinforcement [1].

Structural Studies, Repairs and Maintenance of Heritage Architecture IX 569 The key to a successful and optimal usage of FRP in strengthening and rehabilitation, however, is in our ability to understand and effectively engineer concrete-frp bond. Unfortunately, our understanding of the basic mechanisms that allow FRP to bond to concrete, the processes that promote degradation of the bond, and many other variables that control and define bond is extremely limited. 2 Sprayed FRP technology The FRP Spray technique was developed at the University of British Columbia in conjunction with ISIS Canada by Dr. Nemkumar Banthia. The technique consists of spraying polymer and short, randomly distributed fibers on the surface of concrete such that a 2-diemnsional random distribution of fibers is achieved on the surface. Three basic intergradient of the final composite are handled simultaneously by the pumping and spraying equipment. The resin and catalyst are fed separately into a spray gun and then spayed after mixing. The glass fiber in a revolving format is fed into a chopper unit mounted on top of the spray gun. These two streams combine and continue onto the spraying surface together. After spraying, a roller is used to force out any entrapped air voids and make a consistent thickness [1]. Figure 3 shows the spray gun and spraying process. Lab-tested against existing repair techniques, the FRP Spray has proven to be the strongest and least costly method of bridge deck repair. The technique is estimated to cost about half the amount of traditional steel-jacketing repair techniques, and a third less than fiber reinforced polymer jacketing. Unlike steel jacketing that corrodes over time, FRP spray does not corrode, adding to longterm cost savings. The versatile repair technique can also be used to re-fit other construction surfaces such as steel and timber, and has applications for seismic upgrading in a variety of structures. Figure 3: Left: UBC portable spray gun, Right: Spraying Process [1].

570 Structural Studies, Repairs and Maintenance of Heritage Architecture IX 3 Structural health monitoring 3.1 Specimens Notched 30x10x10 cm beam specimens were used. Different sets of beam with Notch lengths of 4 and 6 cm were tested. Two methods of repair: FRP Spraying and FRP wrapping were used. The challenge at the beginning was the low shear strength of concrete compared to the FRP-Concrete shear bond which leads to the shear failure of the beam instead of de-bonding. This issue was overcome by using FRC concrete (with higher shear capacity) and also using 30x10x3.3 cm specimens (Figure 4). 3.2 Test set up One side FRP sprayed beam specimens (30x10x10 cm) under 4-point loading are utilized in this project. Ten 10-mm one-directional strain gauges and two bidirectional are used for each specimen. The specimens are pre-cracked to dictate the initiation and direction of de-bonding. A closed-loop system for stable crack growth was used and the specimens were tested under quasi static and cyclic loading. Figure 4: Left: beams with wrapped FRP, right: beams with sprayed FRP. 3.3 Results and discussion The samples were initially tested under quasi-static 4-point bending loading. The results are shown in Figure 5. The nonlinearity of the curve is an indication of the bonding forces in action from the first steps of loading. The failure in this case was very sudden which avoided a proper evaluation of post-de-bonding behavior. In the next phase, the system was heavily instrumented and tested under cyclic loading. The substrate and repair material response to loading is monitored using strain gauges carefully installed at different locations of the structure. Data is obtained using data acquisition machine and converter software. The load-stain curves for the strain gauges are graphed. Test set up is shown in figure 6.

Structural Studies, Repairs and Maintenance of Heritage Architecture IX 571 Load vs. Displacement for 30x10x10 cm notched (3 cm) sample#1 with 24x5 cm Sprayed FRP 30 25 20 Load (kn) 15 10 5 0-0.2 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 Disp. (mm) Figure 5: Load vs. Displacement for 35x10x10 cm notched (3 cm) with 24x5 cm sprayed FRP. Figure 6: Left: Instrumentation with uni-directional and bi-directional gauges; right: FRP-concrete bond monitoring test set-up. A gradual divergence between the strain obtained from gauges on FRP and concrete was measured, which is used to define a de-bonding criteria (Figures 7 and 8). The inter-laminar strain measured from bi-directional gauges indicates a potential source of delamination stresses, which help the de-bonding phenomenon.

572 Structural Studies, Repairs and Maintenance of Heritage Architecture IX Strain (micron) Strain vs. load (Half ultimate load) 160 140 120 100 80 60 40 20 0-4 -2 0 2 4 6 8 10 12 14 16-20 -40 Load (kn) SG1 [A] SG2 [A] SG3 [A] SG4 [A] SG5 [A] SG6 [A] SG7 [A] SG8 [A] SG9 [A] SG10 [A] SG11 [A] SG12 [A] Figure 7: Strain vs. load in different strain gauges on FRP and Concrete. Strains from Left Side gauges (1 & 6) vs. Load (ultimate load) 250 200 Strain (micron) 150 100 50 0-5 0 5 10 15 20 25 30 35 SG1 [ A] SG6 [ A] -50 Load (kn) Figure 8: De-bonding progress, definition of de-bonding criteria. 4 Case study The technique of sprayed composites was applied to the Safe Bridge on the Vancouver Island (near Duncan, British Columbia) that needed shear strengthening. Of the three channel beams salvaged from the old bridge, one was rehabilitated with the sprayed GFRP technique while a second was retrofitted using a commercially available continuous fiber wrap system, also composed of E-glass. Before the application of GFRP Spray to the Safe Bridge, the bridge was fully instrumented. Strain gauges were placed on all eleven girders at mid-span and these were then sealed for long term monitoring. The bridge was then tested and calibrated for its response prior to placement of GFRP Spray retrofit by loading

Structural Studies, Repairs and Maintenance of Heritage Architecture IX 573 it at various locations using a fully loaded 28-ton dump truck. After the application of the spray, the bridge was load tested again by loading it at various locations using a 28-ton dump truck (Figures 26a and 26b). The benefits of the spray were observed (Figures 9 and 10). Figure 9: Instrumentation is Safe bridge, Victoria, BC: Left: Traditional Sensors, right: fiber optics [1]. Figure 10: Repair and testing set-up in Safe Bridge, Victoria, VC: left: spraying operation, right: loading test [1]. References [1] Banthia, N., Nandakumar, N, & Boyd, A., Sprayed Fiber Reinforced Polymers: From Laboratory to a Real Bridge, Concrete International, 24 (11), pp. 47-52, 2002. [2] Banthia, N. and Khalighi Y., FRP-Concrete Bond: Issues and Challenges, Indian Concrete Institute Journal, Special Issue: FRP in Concrete Construction, pp 43-46, 2003. [3] Khalighi Y, Structural Monitoring of Bond between FRP and Concrete, 9 th ISIS Canada 9 th Annual Conference, Halifax, Nova Scotia, 2004. [4] ISIS Canada, Reinforcing Concrete Structures with Fiber Reinforced Polymers, Manual #3, ISIS Canada Corporation, Winnipeg, Canada, 2001.

574 Structural Studies, Repairs and Maintenance of Heritage Architecture IX [5] ISIS Canada, Strengthening Reinforced Concrete Structures with Externally Bonded Fiber Reinforced Polymers, Manual #4, ISIS Canada Corporation, Winnipeg, Canada, 2001. [6] Boyd, A.J. Rehabilitation of Reinforced Concrete Beams with Sprayed Glass Fiber Reinforced Polymers. Ph.D. Thesis The University of British Columbia, Vancouver, Canada, 2000.