Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

Similar documents
P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3.

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Regency Horizon HZ30E Gas Fireplace

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

Contemporary Collection

B36XTCE Gas Fireplace

B41XTCE Gas Fireplace

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection

Gas Fireplaces. B36XTE Gas Fireplace. Unit Dimensions with Vignette: Model B36XTE-NG10 B36XTE-LP10 M O S S. V Opening for gas connection

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

PORTRAIT WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 569 Ledge Front


Please consult the manufacturer s installation manual for all details and requirements before making a final design layout decision.

SI T T FST

Builder's Manual for Ortal Fireplaces

CHIMNEYS AND FIREPLACES

Architect & Builder s Guide. ORTAL Heating Systems Ltd.

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

CHIMNEYS AND FIREPLACES

SI T T FSS/FSTT Open Fire

Technical and Dimensional Data. Saf-T Vent SC

Chimney Lining Systems

FEATURES AND SPECIFICATIONS...2 Installation Choices...2

Installation Instructions

Nouveau BBQ Single Flue

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

TC54. for architects & designers. Dimensions Clearances Venting

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Dur aflex stainless steel

Installation and Operation Manual. Safety tested according to ULC-S610 and UL 127 Standards by an accredited laboratory.

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

TCWS54 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Kiva Fireplace GAS BURNING INSTALLATION MANUAL

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

Regency Bellerive & Berwick Zero Clearance Box and Flue Kit Part No Assembly Instructions

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

Installation Manual Installation and Appliance Setup

Installation Manual Installation and Appliance Setup

Installation Manual Installation and Fireplace Setup

Installation Manual Installation and Fireplace Setup

DuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640.

Installation Manual Installation and Fireplace Setup

Installation Manual Installation and Appliance Setup

MASPORT I5000 INSERT FIRE, AUSTRALIAN MODEL

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

APPLICATION FOR FINISHED BASEMENT PERMIT

DirectVent Pro. Simpson Dura-Vent Engineered Excellence

Installation Manual Installation and Fireplace Setup

DIRECT-TEMP METALBESTOS DIRECT VENT SYSTEM

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

Residential Building Plans

Installation Manual Installation and Fireplace Setup

Installation Manual Installation and Appliance Setup

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

Block-In Fireplace Masonry Fireplace 36 ELITE-BI INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & November,

ENGLISH INSTALLATION INSTRUCTION MANUAL. N550 Bakers Oven. CERTIFIED for USA & CANADA SAFETY TESTED to UL & ULC-S

Model: WS18-AU. Model: WS22-AU

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC

Installation Manual Installation and Fireplace Setup

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

WOOD FIRE INSTALLATION GUIDE

Installation and Operation Manual

Installation Manual Installation and Appliance Setup

Installation Manual Installation and Fireplace Setup

APPLICATION AND LISTING

Simpson Dura-Vent Engineered Excellence

Installation Manual Installation and Fireplace Setup

Installation Manual Installation and Fireplace Setup

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

pellet stoves & inserts woo

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

TC30 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

Installation Instructions

TC42 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

Installation Manual Installation and Fireplace Setup

170MM 360MM Specifications

Traditional Open Fire

Installation Manual Installation and Fireplace Setup

the heart of a warm home

Fireplaces and Chimneys

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7

Chimney and Fireplace Inspection Report

Installation Manual Installation and Fireplace Setup

Transcription:

P33 Zero Clearance Direct Vent Gas Fireplace P33 WITH THE FLUSH OR BAY FRONT Model P33-NG4 P33-LP4 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa) Manifold Pressure - Low 1.1 W.C. (0.27 kpa) 3.3 W.C. (0.82 kpa) Orifi ce Size Minimum Input Altitude 0-2000 ft. (0-610m) Minimum Input Altitude 2000-4500 ft. (610-1372m) Maximum Input Altitude 0-2000 ft. (0-610m) Maximum Input Altitude 2000-4500 ft. (610-1372m) #44 DMS - 0-2000ft #45 DMS - 2000-4500ft 12,500 BTU/h (3.66 kw) 10,500 BTU/h (3.07 kw) 22,500 BTU/h (6.59 kw) 21,000 BTU/h (6.15 kw) #54 DMS 10,500 BTU/h (3.07 kw) 21,500 BTU/h (6.30 kw) Vent Sizing 4 Inner / 6 5/8 Outer 4 Inner / 6 5/8 Outer Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent Systems: FPI AstroCap Flex Vent Simpson Direct Vent Pro American Metal Products Amerivent Direct Security Secure Vent Selkirk Direct-Temp Metal-Fab Sure Seal B L Top Header A H Drywall (or other facing) 10" (254mm) dia. Hole through wall Vent. C D F G I M A E Unit Dimensions Description P33 A Front Face Width 33 (838mm) J Q R B Rear Firebox Width 23 (584mm) C Front Face Height 29 (737mm) D Height w/ Standoff 31 1/2 (800mm) E Unit Depth 12-3/4 (324mm) F Firebox Height 28 1/2 (724mm) Framing Dimensions Description P33 G Framing Width 33-1/4 (845mm) H*** Framing Height*** 31-3/4 (806mm)*** I Framing Vertical 19 1/2 (495mm) Vertical Rise Depth Horizontal 16 1/2 (419mm) Rigid 12-3/4 (324mm) Flex J Corner Wall Length 37 1/2 (953mm) K Corner Facing Wall Width 53-1/4 (1353mm) L Framed Chase Ceiling 36 (914mm) Rigid 32 (813mm) Flex M Vent Centerline Height 30 (762mm) Rigid 26 (660mm) Flex *** Important: Framing height requires consideration of the hearth depth. Dimension H = H + the thickness of installed hearth. K N O P Opening for gas connection Dimension Description P33 N Gas Connection Height 1 1/2 (38mm) O Gas Connection Inset 4 (102mm) P Gas Connection Width 3 (76mm) Q Minimum Framing Depth 16 1/2 (419mm) Rigid / 12-3/4 (324mm) Flex R Maximum Framing Depth (including wall thickness) 40 1/2 (419mm) Rigid / 36-3/4 (324mm) Flex Please refer to Exterior Vent Terminations for additional guidelines on vent locations. 28 August 2008 Product Specifications Book

Model P33-NG4 w/ Contemporary Faceplate P33-LP4 w/ Contemporary Faceplate Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa) Manifold Pressure - Low 1.1 W.C. (0.27 kpa) 3.3 W.C. (0.82 kpa) Orifi ce Size #47 DMS #56 DMS Minimum Input Altitude 0-4500 ft. (0-1372m) Maximum Input Altitude 0-4500 ft. (0-1372m) 9,800 BTU/h (2.87 kw) 17,500 BTU/h (5.13 kw) 9,000 BTU/h (2.64 kw) 15,500 BTU/h (4.54 kw) Vent Sizing 4 Inner / 6 5/8 Outer 4 Inner / 6 5/8 Outer Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent Systems: FPI AstroCap Flex Vent Simpson Direct Vent Pro American Metal Products Amerivent Direct Security Secure Vent Selkirk Direct-Temp Metal-Fab Sure Seal Dimension Description P33S O Gas Connection Height 1 1/2 (38mm) P Gas Connection Inset 4 (102mm) Q Gas Connection Width 3 (76mm) R Minimum Framing Depth 16 1/2 (419mm) Rigid / 12-3/4 (324mm) Flex S Maximum Framing Depth (including wall thickness) 40 1/2 (1028mm) Rigid / 36-3/4 (933mm) Flex Important: Unit Dimensions Description P33 with Contemporary Faceplate A Front Face Width 33 (838mm) B Rear Firebox Width 23 (584mm) C Front Face Height 29 (737mm) D Height w/ Standoff 31 1/2 (800mm) E Unit Depth 12-3/4 (324mm) F Firebox Height 29 (737mm) Framing Dimensions Description P33 with Contemporary Faceplate G Framing Width 33-1/4 (845mm) H** Framing Height** 31-3/4 (806mm)** I* Framing Rise from Floor 1 (25mm) minimum* J Framing Depth Vertical Horizontal 19 1/2 (495mm) Vertical Rise 16 1/2 (419mm) Rigid 12-3/4 (324mm) Flex If the Contemporary Faceplate is used on the P33-NG4/P33- LP4 Gas Fireplace, the burner orifi ce (Both NG/LP supplied in package) must be replaced and an overlay decal (also supplied with kit) must be affi xed to the current serial number decal supplied with unit. Note: Also see framing dimensions for this optional front if installed on the P33-4 unit. Note: Unit must be raised up by 1' to allow for faceplate installation. NG LP Current P33-4 orifi ce size: #44 #54 Must replace with: #47 #56 Warning: Fire hazard is an extreme risk if these changes are not adhered to. K Corner Wall Length 37 1/2 (953mm) L Corner Facing Wall Width 53-1/4 (1353mm) M*** Framed Chase Ceiling*** 36 (914mm) Rigid*** 32 (813mm) Flex*** N Vent Centerline Height 30 (762mm) Rigid 26 (660mm) Flex * The unit must be raised a minimum of 1 above the finished floor. ** Dimension H = H + I (minimum) *** Dimension M = M + I (minimum) August 2008 Product Specifications Book 29

Framing and Finishing 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2 (13mm) to 1-¼ (32mm) thick. 2) Frame in the enclosure for the unit with framing material. 3) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapor barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.) 4) The top of the unit must not be closer than 30 (762mm) to the ceiling. 5) Combustible material may be brought up to the top and sides of the unit and be covered with ceramic tiles, bricks, rock or other suitable combustible finishing materials. Note: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is 0 to the standoffs so combustible building materials can be laid directly on top of the standoffs. You must maintain proper clearances from the vent to combustible materials (See Below). 6) Use metal studs for framing where the minimum clearance from the vent to combustible material cannot be maintained. Clearance Requirements Vent Clearances Horizontal - Top Horizontal - Side Horizontal - Bottom Vertical - Flex Vertical - Rigid WARNING Failure to maintain required clearances is a major cause of chimney related fires. Installation of this fireplace must comply with these clearances. Combustible Mantels Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher. Mantel Clearances 12 10 8 6 4 12"(305mm) 2 7-1/2"(191mm) Clearance Dimension 2-1/2 (64mm) 1-1/2 (38mm) 1-1/2 (38mm) 1-1/2 (38mm) 1-1/4 (32mm) 0 Drywall C A D F 0 B C 3-1/2"(89mm) D 3 (76mm) Standoff B A Top of Unit B Side View Mantel Clearances A B C D Front 29 (737mm) 11 (279mm) 9 (229mm) 7 (178mm) E Clearance: Dimension Measured From: A: Mantel Height 7 (178mm) Minimum (Additional on this page) B: Sidewall 7-1/2 (191mm) Side of installed front C: Ceiling 30 (762mm) Top of installed unit D: Mantel Depth 12 (305mm) Maximum (Additional on this page) E: Alcove Width 48 (1219mm) Sidewall to Sidewall (Minimum) F: Alcove Depth 36 (914mm) Front to back wall (Maximum) Top of Hearth must not be higher than the base of the fi rebox. Note: If desired a non-combustible mantel may be installed at a lower height. Note: Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour. Mantel Leg Clearances Combustible mantel leg clearances as per diagram below: Clearances are from the fi nished edge of the unit or an installed front. Maximum 1-1/2 projection at 2 minimum clearance. 30 August 2008 Product Specifications Book

C Clearance Requirements with Contemporary Faceplate C Combustible Mantels with Contemporary Faceplate Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher. B Close to Ceiling *Note: All measurements are from the top/side of the unit, not optional front. Clearance: Dimension Measured From: A: *Front Floor Clearance (min.) 1" (25mm) Underside of Unit B: *Sidewall 7-1/2" (241mm) Side of Unit C: *Ceiling (room and/or alcove) 30" (889mm) Top of Unit D: Alcove Width 48" (1219mm) Sidewall to Sidewall (Minimum) E: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) Mantel Leg Clearances with Contemporary Faceplate Combustible mantel leg clearances from side of unit as per diagram below: Clearances are from the fi nished edge of the unit or an installed front. Flue Clearances to Combustibles Horizontal - Top 2-1/2" Horiztonal - Side 1-1/2" Horiztonal - Bottom 1-1/2" Vertical (Flex Vent) 1-1/2" Vertical (Rigid) 1-1/4" Top View 0-3 WARNING Failure to maintain required clearances is a major cause of chimney related fires. Installation of this fireplace must comply with these clearances Please note: Due to ongoing product development, product appearance and specifications are subject to change without notice. Caution Requirements The top, back and sides of the fi replace are defi ned by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. WARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions. August 2008 Product Specifications Book 31

FPI Direct Vent System (Flex) Horizontal Terminations Only This venting system, in combination with the P33 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram, see manual. FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P33 using a flexible vent. FPI Kit # Length Contains: #946-513 2 Feet 1) 6-5/8 fl exible liner (Kit length) 2) 4 fl exible liner (Kit length) 3) spring spacers (3) #946-515 4 Feet 4) thimble (2) 5) AstroCap termination cap (1) 6) screws (12) #946-516 10 Feet 7) tube of Mill Pac (1) 8) plated screws (8) 9) S.S. screws #8 x 1-1/2 drill point, (4) Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Horizontal sections must be supported every 3 feet. Important When installing Cabinet Mantels: the wall thimble must be secured fi rst and venting must be attached to unit before sliding into fi nal position. Snorkel Terminations Snorkel Terminations: For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations and the Riser Vents are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down. Dura-Vent Snorkel Min. 12"* (305mm) Riser Vent Termination Min. 6-1/4"* (159mm) 4" (102mm) dia. flue pipe Wall Thimble (2 pc) 6-7/8" (173mm) dia. Flue pipe spring spacer AstroCap TM Termination Cap (Part# 946-523/P) Below Grade Snorkel Installation (Dura-Vent Only) If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure. Alternate Horizontal Termination Caps Dura-Vent Snorkel Min. 12"* (305mm) Window Well Adequate drainage If required by the external termination location the listed alternate termination caps may be used. Gravel 32 August 2008 Product Specifications Book

0 Rigid Pipe Venting Horizontal or Vertical Terminations 2 4 6 8 10 12 14 40 38 36 34 32 Maximum: 40 ft. (12.2m) 30 Alternate Horizontal Termination Caps 28 26 24 22 If required by the external termination location the listed alternate termination caps may be used. (Refer to Page 11) Venting Arrangements - Vertical Terminations Rigid Pipe System (Propane & Natural Gas) Vertical Height (Feet) 20 18 16 14 Maximum: 27 ft. (8.2m) The P33 is approved for a maximum 40 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas. 12 The lightly shaded area,, in the diagram shows allowable venting confi gurations with a maximum two 45 elbows. 10 The darker shaded area,, in the diagram shows allowable venting confi gurations using one 45 and one 90 elbow. 8 Vent must be supported at offsets. Horizontal sections must be supported every 3 feet. Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustible materials. Minimum of 1 pipe section between elbows. Note: Must use optional rigid pipe adapter when using Rigid Pipe (Part # 510-994). 6 4 2 Minimum 8 6 (2.6m) Minimum 9 6 (2.9m) * Unit must be raised by 1 when using Contemporary Faceplate 0 Minimum 12 (305mm) Max. 10 (3m)(centerline to centerline) August 2008 Product Specifications Book 33

Vertical Venting with Two (2) 90 Elbows - Initial vertical section. Option V H V+ V1 Maximum total pipe: length, of A) 1 Min. 4 Max. 2 Min. all sections, must not exceed 30 feet. B) 2 Min. 5 Max. 3 Min. Total horizontal sections must C) 3 Min. 6 Max. 4 Min. not exceed 8 feet. Minimum of 1 foot between D) 4 Min. 7 Max. 5 Min. 90 elbows is required. E) 5 Min. 8 Max. 6 Min. Vertical Venting with Three (3) 90 Elbows - Initial vertical section. Option V H + H1 V+ V1 Maximum total pipe: length, of A) 2 Min. 3 Max. 4 Min. all sections, must not exceed 30 feet. B) 3 Min. 4 Max. 6 Min. Total horizontal sections must C) 4 Min. 5 Max. 7 Min. not exceed 8 feet. Minimum of 1 foot between D) 5 Min. 6 Max. 8 Min. 90 elbows is required. E) 6 Min. 7 Max. 9 Min. F) 7 Min. 8 Max. 10 Min. Vertical Venting with Two (2) 90 Elbows - Initial horizontal section. Option H + H1 V Maximum total pipe: length, of A) 2 Max. 2 Min. all sections, must not exceed 30 feet. B) 3 Max. 3 Min. Total horizontal sections must C) 4 Max. 4 Min. not exceed 6 feet. Minimum of 1 foot between D) 5 Max. 5 Min. 90 elbows is required. E) 6 Max. 6 Min. Vertical Venting with Three (3) 90 Elbows - Initial horizontal section. Option A) H 1 Max. V 1 Min. H + H1 3 Max. V+ V1 3 Min. Maximum total pipe: length, of all sections, must not exceed 30 B) 2 Max. 2 Min. 4 Max. 5 Min. feet. Total horizontal sections C) 3 Max. 3 Min. 5 Max. 7 Min. must not exceed 7 feet. D) 4 Max. 4 Min. 6 Max. 9 Min. Minimum of 1 foot between 90 elbows E) 5 Max. 5 Min. 7 Max. 11 Min. is required. 34 August 2008 Product Specifications Book

Venting Arrangements - Horizontal Terminations This lightly shaded area of the diagram shows allowable combinations of vertical runs with horizontal terminations, using one 45 and one 90 elbow (two 45º elbows equal one 90 elbow). Note: Must use optional rigid pipe adapter (Part # 510-994) when using Rigid Pipe. Maintain clearances to combustibles. Horizontal vent must be supported every 3 feet. Firestops are required at each fl oor level and whenever passing through a wall. A vent guard may be required as per local codes, refer to Exterior Vent Termination Locations. Note: FPI Direct Vent System (Flex) is only approved for horizontal terminations. * Unit must be raised by 1 when using Contemporary Faceplate Please refer to Exterior Vent Terminations for additional guidelines on vent locations. August 2008 Product Specifications Book 35

Horizontal Venting with Two (2) 90 Elbows - Initial vertical section. Option V H+ H1 Maximum total pipe: length, of A) 1 Min. 3 Max. all sections, must not exceed 30 feet. B) 2 Min. 4 Max. Total horizontal sections must C) 3 Min. 5 Max. not exceed 8 feet. Minimum of 1 foot between D) 4 Min. 6 Max. 90 elbows is required. E) 5 Min. 7 Max. F) 6 Min. 8 Max. Horizontal Venting with Three (3) 90 Elbows - Initial vertical section. Option V H V+ V1 H + H1 Maximum total A) 2 Min. 1 Max. 3 Min. 4 Max. pipe: length, of all sections, must B) 3 Min. 2 Max. 4 Min. 5 Max. not exceed 30 C) 4 Min. 3 Max. 6 Min. 6 Max. feet. Total horizontal D) 5 Min. 4 Max. 8 Min. 7 Max. sections must not E) 6 Min. 5 Max. 10 Min. 8 Max. exceed 8 feet. Minimum of 1 F) 7 Min. 6 Max. 12 Min. 9 Max. foot between 90 elbows is required. Horizontal Venting with Two (2) 90 Elbows - Initial horizontal section. Option H V H + H1 Maximum total pipe: length, of A) 1 Max. 1 Min. 3 Max. all sections, must not exceed 30 feet. B) 2 Max. 2 Min. 5 Max. Total horizontal sections must C) 3 Max. 4 Min. 6 Max. not exceed 8 feet. Minimum of 1 foot between D) 4 Max. 6 Min. 7 Max. 90 elbows is required. E) 5 Max. 8 Min. 8 Max. Horizontal Venting with Three (3) 90 Elbows - Initial horizontal section. Option A) H 1 Max. V 1 Min. H + H1 + H2 3 Max. Maximum total pipe: length, of all sections, must not exceed 30 B) 2 Max. 3 Min. 5 Max. feet. Total horizontal sections C) 3 Max. 5 Min. 6 Max. must not exceed 7 feet. D) 4 Max. 7 Min. 7 Max. Minimum of 1 foot between 90 elbows E) 5 Max. 9 Min. 8 Max. is required. F) 6 Max. 11 Min. 9 Max. 36 August 2008 Product Specifications Book

30 (762mm) Vertical termination with co-linear flex system The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance. Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending. The Air Intake pipe must be attached to the inlet air collar of the termination cap. This appliance is designed to be attached to two 3 (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements for minimum and maximum heights. Required Parts: Part # Description 946-529 Co-linear DV Vertical Termination Cap 948-305 3 Flex - 35 ft. 946-563 Coaxial to Co-linear Adapter Kit 510-994 Rigid Pipe Adapter 58dva-E45 45º Elbow Alternate Approved Caps 46dva-VC Vertical Termination Cap 46dva-VCH High Wind Cap 46dva-GK 3 Co-linear Adapter with fl ashing Co-linear DV Vertical Termination Cap # 946-529 A maximum of two certified joiner kits may be used per length. #948-305 35 ft (11m) Flex Liner 30 Rigid Pipe Adapter # 510-994 Outer Pipe with Kit# 946-563 Pipe Length Exhaust Flue o 45 Elbow Inner Pipe Adapter with Kit# 946-563 Air Intake Co-Linea Flex Adapter with Kit# 946-563 Vertical Height (feet) 2 (51mm) max. 8' (2.4m) Min. 30' (9.1m) Max. Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. Please refer to Exterior Vent Terminations for additional guidelines on vent locations. August 2008 Product Specifications Book 37