* Strata-X is patented by Phenomenex, Inc. Oasis is a registered trademark of Waters Corporation. Phenomenex is not affiliated with Waters

Similar documents
On-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes

Finally an Easier Solution for Protein Precipitation

Preparative / Process

Extraction and Dispersive Kits User Guide

The New Standard in High Resolution Size Exclusion

CHARACTERIZATION & PURIFICATION

TN-014. A Simple Approach to Automated Solid Phase Extraction (SPE) with Strata -X Polymeric Sorbents

No Lab-Drama Llama is Here

APPLICATIONS TN Detection and Identification of Gulf Oil Dispersants (COREXIT 9527 and 9500) by GC/MS and LC/MS/MS

See. Beyond HALO. and Sigma-Aldrich Biotechnology. Advanced Materials Technology. Ascentis. Express

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Clarity BioSolutions For Synthetic DNA/RNA Advance Your. Oligonucleotide Work. From Sample Preparation to Analysis and Purification

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

[ product solution ] Waters Oasis µ Elution PlateS. Patented Innovation. Elution volume as low as 25 μl. No evaporation and reconstitution

APPLICATIONS TN Automated Method Development of Oligonucleotide in Tissues Using Clarity OTX 96-Well Plate and High Resolution Mass Spectrometry

Scaling from Analytical to Preparative Chiral Chromatography While Balancing Purity, Yield, and Throughput under HPLC and SFC Conditions

Let s Clear the Air...

BIOANALYSIS CONSUMABLE SOLUTIONS. Sample Preparation and Liquid Chromatography Solutions for Quantitative BIOANALYSIS

Liner Style* Function Advantages Disadvantages Recommended For Straight Low surface area for less activity Least expensive Low activity

General Protocol. Solutions.

CLARICEP FLASH. Irregular & Spherical Silica Columns. Consistent High Performance. Wide Range of Selectivities. High Pressure Tolerance

Simplify Your SPE. from phenomenex. SPE Method Solution Guide. WEB

EVOLUTE ABN SPE Columns for Solid Phase Extraction of Environmental Samples

B r i n g i n g e x p e r t s t o g e t h e r TELOS neo Polymeric Solid Phase Extraction Columns Simple and Effective SPE

EVOLUTE ABN FOR EXTRACTION OF DRUGS FROM BIOLOGICAL FLUIDS

ph Flexibility Expands Robustness and Reproducibility

A Generic Approach to the Extraction of Multi-functional Drugs using Mixed-mode SPE with LC-MS/MS Analysis

GC Columns GC COLUMN INSTALLATION GUIDE.

The Benefits of SOLAμ Technology in Sample Preparation. Jon Bardsley and Ken Meadows Thermo Fisher Scientific, Runcorn, UK

[ Care and Use Manual ] Waters AccellPlus QMA and CM Bulk Media. I. calculating bulk media needs. II. packed column use. IIi.

The system has an optimized porosity distribution and acts as a depth filter, retaining the precipitated protein without well blockage.

Thank you for joining us! Our Webinar will begin shortly Principles of SPE: Troubleshooting Techniques

Switch to BioSep GFC Columns for Protein Analysis

Broader Adoption of SPE in Environmental Applications Enabled by Selective SPE Chemistries. Kory Kelly and Allen Misa

Application Guide ENVIRONMENTAL SAMPLE PREPARATION CLEAN QUICK ACCURATE.

Strategies for Phospholipid Removal using Polymer-based SPE

Empore. Solid Phase Extraction Cartridges. Technical Information. Product Description. Product Characteristics. Sorbents Available

New Core-Shell Technology

Experimental Procedure

Agilent Sample Preparation Portfolio ACCURATE, REPRODUCIBLE RESULTS RIGHT FROM THE START

FRACTIONLYNX APPLICATION MANAGER

User s Guide for Extracting Oligo Therapeutics from Biological Samples

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

EFFECTIVE SPE STRATEGIES FOR LC/MS DETERMINATION OF SUDAN DYES IN CHILI PRODUCTS

ALLIANCE SYSTEM FOR CARBAMATE ANALYSIS

Rapid Extraction of Therapeutic Oligonucleotides from Primary Tissues for LC/ MS Analysis Using Clarity OTX, an Oligonucleotide Extraction Cartridge

OptiFlow Quant Solution for High-Sensitivity Quantitation

Sample Prep - Solid Phase Extraction

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

ENHANCED MS WITH THE TURN OF A KEY

SPE in Disk Format. Experimental. Table 1 Comparison of Typical SPE Cartridge and Empore Disk

Take A Deep Breath. Set down that multi-channel pipette. And let us take you to a new state of biologics Zen.

Nonylphenols and Ethoxylates in Water by LC/MS/MS

Use of ScreenExpert RoboColumns u

CLEAN SCREEN FASt FILTER AND SHOOT UCT FORENSICS. CLEAN SCREEN FASt SPE COLUMNS

Microflow LC-MS with the turn of a key

BioSolutions for Synthetic DNA/RNA

Method Optimisation in Bottom-Up Analysis of Proteins

of peptide mapping chemistries, 130Å or 300Å with tunable UV, photodiode array, or mass spectrometry

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

QIAcube Pure Efficiency

ApplicationNOTE Introduction

BIOANALYTICAL STRATEGY FOR IN VITRO METABOLITE SCREENING WITH EXACT MASS USING THE Q-Tof micro. Jose M. Castro-Perez 1, Carina Leandersson 2

Extraction of Vitamin B7 (Biotin) from Serum Using EVOLUTE

User s Guide for. Extracting Oligo Therapeutics from Biological Samples

PESTICIDE SCREENING APPLICATION SOLUTION

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

A Fast and Effective Approach for Running EPA Method 539: Determination of Hormones in Drinking Water using SPE and LC/MS/MS

Investigation of Solid Phase Microextraction as an Alternative to Dried Blood Spot

QIAGEN Supplementary Protocol

Comparing Performance of High-Throughput, Trityl-on RNA/DNA Purification Products Author: Greg Scott

[ ANALYTICAL SERVICES SOLUTIONS ] constant DEADLINES... FASTER THAN EVER BEFORE.

QIAcube HT Your Purification Expert

columnsi o n P a c C S 1 6 C a t i o n - E x c h a n g e C o l u m n

Application Note USD Purification of Mouse IgM from Cell Culture Supernatant by Cation Exchange Chromatography on CM Ceramic HyperD F Sorbent

Illicit Drug Analysis in Urine Using 2D LC-MS/MS for Forensic Toxicology

Instructions for Capillary Electrophoresis Peptide Analysis Kit

Microbiology Enlightened

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Jonathan R. Beck and Charles T. Yang; Thermo Fisher Scientific, San Jose, CA

[ PURIFICATION SOLUTIONS ] Pure at Heart

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Automated Rapid and Robust SPE Method Development Using strata X 96-Well Plates

Application Note. Abstract. Authors. Food Safety

Evaluating Microplate Detection Instruments

Determination of Endocrine Disrupting Hormones in Drinking and Wastewater

Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

[ MS IMAGING ] FULL SPECTRUM MOLECULAR IMAGING COMPLETE VISUALIZATION OF MOLECULAR DISTRIBUTIONS

Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION

A Rapid imethod TM Test for Analysis of Four Immunosuppressants

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

EtG / EtS Analysis UCT INNOVATION THROUGH CHEMISTRY FORENSICS

EPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS

Food and Environmental Analysis. A Quicker. and Easier. Sample Preparation Choice.

Universal Solution for Monoclonal Antibody Quantification in Biological Fluids Using Trap-Elute MicroLC-MS Method

BioTrap 500 C18/C8 INSTRUCTION MANUAL. for direct injection of up to 500 µl plasma in HPLC. Illustration of a BioTrap 500 particle

patent pending BioSolutions Purification solutions for synthetic RNA & DNA Clarity QSP (NEW) Oligo-RP Desalting

QIAsymphony SP Protocol Sheet

Transcription:

* Strata-X is patented by Phenomenex, Inc. asis is a registered trademark of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. 2010 Phenomenex, Inc. All rights reserved.

Fact: *Strata -X outperforms asis HLB In three critically evaluated areas... 1 Recovery Don t lose critical compounds 2 Loadability Avoid loading volume limitations 3 Reproducibility Can you afford to re-run samples? * Strata-X is patented by Phenomenex, Inc. asis is a registered trademark of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. 2010 Phenomenex, Inc. All rights reserved. 2

Table of Contents Higher Recovery...4 Greater Loadability...5 Better Reproducibility...6 Maximum Versatility, Balance Recovery and Cleanup...7 Improve Your Results Even More...8 Dedicated to Your Success...9 rdering Information...10 Quality Products Guaranteed...11 Strata -X Promise Phenomenex is dedicated to your complete satisfaction! We are committed to making Strata TM -X your first choice for solid phase extraction (SPE) by dedicating a technical account manager to your company, continuously developing innovative technologies, creating pertinent technical resources, and providing service globally. If Strata -X SPE products do not perform as well or better than your current SPE product of similar phase, mass and size, send in your comparative data within 45 days and keep the Strata-X SPE product for FREE! 3 www.phenomenex.com

) ) ) 1 Higher Recovery FACT: Strata -X is a functionalized polymeric sorbent that contains N-Vinylpyrrolidone, which offers multiple modes of retention for stronger analyte-sorbent interaction. Pi-Pi Bonding Hydrogen Bonding, Dipole-Dipole Interactions Hydrophobic Interactions )n u )n u )n u Ṅ. Ṅ. Ṅ. u Analyte-sorbent interaction site highlighted in green. ADVANTAGE: Stronger wash! Use up to 60 % organic without sacrificing recovery! 120 Polar Compound Recoveries at 60 % MeH Wash % Recovery 100 80 60 40 20 Condition: 800 µl methanol followed by 800 µl water Load: 500 µl plasma diluted with 1 ml water (spiked conc. ULQ = 500 ng/ml; LLQ=5 ng/ml) Wash 1: 800 µl water Wash 2: 800 µl 60 % MeH/water Dry: 1-2 mins at 10 of Hg Elute: 2 x 200 µl 100 % MeH 0 Procainamide Carbamazepine ß-Methasone Atenolol Polar Basic Compound Strata -X asis HLB asis is a registered trademark of Waters Corporation. 4 Phenomenex is not affiliated with Waters Corporation. * Contact Phenomenex for method details.

2 Greater Loadability FACT: Strata -X plates have been engineered to allow higher loading volumes than asis HLB plates, which helps to avoid limits on loading volumes that can lead to problems with lower limit of quantification (LLQ) and lower limit of detection (LLD) of low concentration analytes. ADVANTAGE: Increase sample mass on sorbent Increase signal-to-noise ratio Greater Well Volume in Strata -X 96-Well Plates 2 ml 1.5 ml Strata TM -X asis HLB HELPFUL TIP: Strata -X sorbents allow you to load 250 µl of plasma or 500 µl of urine on a 30 mg sorbent bed. Enthalpy has maintained an excellent relationship with Phenomenex because of the quality, selection, and consistency of Phenomenex s HPLC columns and SPE sorbents. This, coupled with personal, customer focused service, ensures that Enthalpy will work closely with Phenomenex for many years to come. Brian Nofsinger, Ph.D., Enthalpy Analytical, Inc., Durham, NC asis is a registered trademark of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. www.phenomenex.com 5

3 Better Reproducibility FACT: Phenomenex completes over 20 QA and QC tests on Strata -X products to ensure batch-to-batch reproducibility. Surface Area Pore Size Pore Volume Surface ph Particle Diameter Particle Size Distribution % Water % Si 2 % Fe 2 3 Purity Carbon Loading Hydrogen Loading Surface Coverage Residue Turbidity Sorbent Weight Flow Rate Tube Purity Frit Purity Dye Tests Chromatogram 11 Probes Used ADVANTAGE: Greater consistency in your results More robust methods Strata-X SPE cartridges were perfect for method development in a recent LC/MS/MS application. They handled complex dairy samples with consistent results and I found the flow rate easier to control than that of a competitor s cartridge. Andrew Patterson, Vista Analytical Laboratory, El Dorado Hills, CA Coefficient of Variation Coefficient of Variation Experienced on Strata Coefficient TM -X and of Variation asis Experienced HLB on Strata TM -X and asis HLB 24 22 20 18 16 14 12 10 8 6 4 2 0 10 15 20 25 30 40 50 60 70 80 90 100 % MeH in wash Strata -X CV % asis HLB CV % Percent Concentration of MeH in Wash Strata TM -X CV % HLB CV % 10 3.7 6.2 15 2.2 2.3 20 4.8 10.0 25 2.3 7.7 30 7.1 14.8 40 4.6 11.3 50 3.3 14.8 60 12.2 12.3 70 3.7 21.5 80 15.6 23.2 90 8.8 12.4 100 12.8 8.5 6 * asis is a registered trademark of Waters Corporation. Phenomenex is not affilitated with Waters Corporation.

Maximum Versatility FACT: The chemistry behind Strata -X allows you to increase the ability to retain a wider variety of compounds. ADVANTAGE: Simplified method development Selectivity for acidic, basic, and neutral compounds Acidic, Acidic, Neutral, Neutral, and and Basic Basic Compound Compound Recoveries Recoveries at 50 % Methanol at 50 Wash % Methanol Wash 120 100 H 3 C Naproxen Betamethasone Propranolol H CH 3 C 2 H H F H H H H H 3 C CH 3 NH H pka 4.4 pka N/A pka 9.14 102 % Recovery 109 % Recovery 94 % Recovery % Recovery 80 60 40 20 0 ph Naproxen Betamethasone Propranolol 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Balance Recovery and Cleanup FACT: There exists an inverse relationship between the strength of your wash solvent(s) and the amount of contaminants that are left behind in your sample. Achieve greater sensitivity by increasing the strength of your wash. ADVANTAGE: Increase signal-to-noise ratio Decrease ionization suppression Relationship Between Recovery and Matrix Effect with Increases in rganic Wash 180 + 80 % 160 + 60 % % Recovery of Procainamide 140 + 40 % 120 + 20 % 100 0 % 80-10 % 60-20 % 40-30 % 20-40 % ENHANCEMENT SUPPRESSIN Matrix Effect on Ionization At 60 % organic wash a balance between high recovery and low ion suppression is reached on Strata -X. 0-50 % 10 15 20 25 30 40 50 60 70 80 90 100 % rganic Wash Recovery Ion Suppression / Ion Enhancement www.phenomenex.com 7

Improve Your Results Further HELPFUL TIP: Splitting your elution solvent volume into 2 aliquots can increase your recovery when compared to eluting in only 1 aliquot. 100 90 80 TM Strata -X (60 mg/3 ml) under Different Elution Conditions % Recovery of Atenolol 70 60 50 40 30 20 10 0 Elution Conditions 2 x 500 µl MeH 1 x 1000 µl MeH The Phenomenex [sample] preparation specialists have been enormously helpful they have helped us to choose the right columns and have helped us to develop our protocols. Thank you Phenomenex! New England Aquarium, Boston, MA HELPFUL TIP: When working with basic compounds, adding Formic Acid to your eluent can significantly increase your eluent strength, resulting in a higher recovery and making it possible to decrease your elution volume. 100 Effect of Acid on Elution of Atenolol TM on Strata -X (30 mg/1 ml) % Recovery of Atenolol 80 60 40 20 1 x 1000 µl MeH 250 µl MeH (preceded by 100 µl Acetic Acid) Let 100 µl acetic acid percolate thru the cartridge first and then add 250 µl of methanol 2 x 200 µl 2 % FA/MeH 0 Elution Conditions 8

Dedicated to Your Success Access your FREE* copy of the SPE method development software via the web at: Strata -X Method Development Software www.phenomenex.com/info/spesoftware Strata TM -X method development software allows you to quickly take advantage of the sample cleanup benefits SPE offers by: Developing a complete SPE method around your target compound Walking you through method troubleshooting ffering method optimization steps for the highest yields Free n-site Seminar Contact us and schedule a FREE* on-site seminar on SPE Method Development. * Subject to terms and conditions of the Software License Agreement. All offers subject to change or withdrawal without notice. www.phenomenex.com 9

) ) Act Now! Try Strata -X Today! Strata -X )n Strata -XL )n Ṅ. Ṅ. Material Characteristics Particle Size (µm) 33 Pore Size (Å) 85 Surface Area (m 2 /g) 800 ph Stability 1-14 Material Characteristics Particle Size (µm) 100 Pore Size (Å) 300 Surface Area (m 2 /g) 520 ph Stability 1-14 Format Sorbent Mass Part Number Unit Price Tube 30 mg 8B-S100-TAK 1 ml (100/box) 30 mg 8B-S100-TBJ 3 ml (50/box) 60 mg 8B-S100-UBJ 3 ml (50/box) 100 mg 8B-S100-EBJ 3 ml (50/box) 100 mg 8B-S100-ECH 6 ml (30/box) 200 mg 8B-S100-FBJ 3 ml (50/box) 200 mg 8B-S100-FCH 6 ml (30/box) 500 mg 8B-S100-HBJ 3 ml (50/box) 500 mg 8B-S100-HCH 6 ml (30/box) Giga Tube 500 mg 8B-S100-HDG 12 ml (20/box) Format Sorbent Mass Part Number Unit Price Tube 30 mg 8B-S043-TAK 1 ml (100/box) 60 mg 8B-S043-UBJ 3 ml (50/box) 100 mg 8B-S043-EBJ 3 ml (50/box) 200 mg 8B-S043-FBJ 3 ml (50/box) 200 mg 8B-S043-FCH 6 ml (30/box) 500 mg 8B-S043-HCH 6 ml (30/box) Giga Tube 2 g 8B-S043-KDG 12 ml (20/box) 2 g 8B-S043-KEG 20 ml (20/box) 5 g 8B-S043-LEG 20 ml (20/box) 5 g 8B-S043-LFF 60 ml (16/box) 10 g 8B-S043-MFF 60 ml (16/box) 1 g 8B-S100-JDG 12 ml (20/box) 1 g 8B-S100-JEG 20 ml (20/box) 2 g 8B-S100-KEG 20 ml (20/box) 5 g 8B-S100-LFF 60 ml (16/box) 96-Well Plate 30 mg 8E-S043-TGB 2 Plates/Box 200 mg 8E-S043-FGB 2 Plates/Box 400 mg 8E-S043-5GB 2 Plates/Box Teflon Tube 96-Well Plate 200 mg 8B-S100-FDG-T 12 ml (20/box) 10 mg 8E-S100-AGB 2 Plates/Box 30 mg 8E-S100-TGB 2 Plates/Box 60 mg 8E-S100-UGB 2 Plates/Box n-line Extraction Cartridge Description Part Number Unit/Box Price Strata-X n-line extraction cartridge, 20 x 2.0 mm 00M-S033-B0-CB Cartridge holder, 20 mm CH0-5845 ea ea Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www.phenomenex.com/termsandconditions. Trademarks Strata-X and Giga are trademarks of Phenomenex, Inc. asis and Waters are registered trademarks of Waters Corp. Phenomenex, Inc. is not affiliated with Waters Corporation. Disclaimers Phenomenex, Inc. is not affiliated with Waters Corporation. Strata-X is patented by Phenomenex, Inc. 10 2010 Phenomenex, Inc. All rights reserved.

Quality Products Guaranteed Rigorous Quality Control (QC) and Quality Assurance (QA) measures are incorporated into the manufacturing process of all Strata TM -X products to ensure they meet the level of performance demanded in any lab setting. A. Allows for complete traceability B. Recovery Tests- Reproducible recoveries for reliable method development. C. Particle Characterization- Tight particle size distribution gives consistent and optimal flow from tube-to-tube resulting in consistent sample processing on a vacuum manifold. D. Purity Tests- High purity sorbent, tubes, and frits are used to give leachate-free extracts, eliminating potential contaminants that may interfere with analysis. E. Production Lot Tests- Strata -X sorbents have been optimized to batch-to-batch and tube-to-tube reproducibility. A. B. C. D. E. This is the best service I have got after working in a chemistry lab for over 10 years. Honghui Zhu, Agricultrual Agri-Food If Strata TM -X SPE products do not perform as well or better than your current SPE product of similar phase, mass and size, send in your comparative data within 45 days and keep the Strata-X SPE product for FREE! 11 www.phenomenex.com

Australia t: 02-9428-6444 f: 02-9428-6445 auinfo@phenomenex.com Austria t: 01-319-1301 f: 01-319-1300 anfrage@phenomenex.com Belgium t: +31 (0)30-2418700 f: +31 (0)30-2383749 beinfo@phenomenex.com Canada t: (800) 543-3681 f: (310) 328-7768 info@phenomenex.com Denmark t: 4824 8048 f: 4810 6265 nordicinfo@phenomenex.com Finland t: 09-4789 0063 f: +45 4810 6265 nordicinfo@phenomenex.com France t: 01 30 09 21 10 f: 01 30 09 21 11 franceinfo@phenomenex.com Germany t: 06021-58830-0 f: 06021-58830-11 anfrage@phenomenex.com Ireland t: 01 247 5405 f: +44 1625-501796 eireinfo@phenomenex.com Italy t: 051 6327511 f: 051 6327555 italiainfo@phenomenex.com Luxembourg t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com Mexico t: (55) 5018 3791 f: (310) 328-7768 tecnicomx@phenomenex.com Netherlands t: 030-2418700 f: 030-2383749 nlinfo@phenomenex.com New Zealand t: 09-4780951 f: 09-4780952 nzinfo@phenomenex.com Norway t: 81 00 20 05 f: +45 4810 6265 nordicinfo@phenomenex.com Puerto Rico t: (800) 541-HPLC f: (310) 328-7768 info@phenomenex.com United Kingdom t: 01625-501367 f: 01625-501796 ukinfo@phenomenex.com All other countries: Corporate ffice USA t: (310) 212-0555 f: (310) 328-7768 info@phenomenex.com BR67741109_I www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com