final report Water quality improvement strategy for a processing site

Similar documents
Johns Environmental Pty Ltd. Solids Removal & Grit Recovery by Hydrocyclone

Environmental Biotechnology Cooperative Research Centre Date submitted: March 2008 Date published: March 2011

Investigations on Ralph s Nitrification/Denitrification Waste Treatment Plant

NITROGEN REMOVAL OPTIMISATION FROM COMPLEX WASTEWATER

Final report. Date published: May PUBLISHED BY Meat and Livestock Australia Limited Locked Bag 991 NORTH SYDNEY NSW 2059

AMPC Wastewater Management Fact Sheet Series Page 1

AMPC Wastewater Management Fact Sheet Series Page 1

Monitoring the Performance of Anaerobic Ponds in the Treatment of Abattoir Wastewater

The costs of rendering

OPERATIONAL CHALLENGES AT THE KOORLONG WASTEWATER TREATMENT PLANT. Derek de Waal Kevin Murphy

Preliminary Assessment of the Opportunity for Methane Recovery from Wastewater at the Frigosinú SA Slaughterhouse, Monteria, Cordoba, Colombia

Case Study. Biological Help for the Human Race. Bathurst Municipal Wastewater Treatment Works, New South Wales, Australia.

final report Effects of rendering / blood processing on abbatoir waste and emissions

LOW OPERATING COST WASTEWATER TREATMENT TECHNOLOGIES FOR RED MEAT AND OTHER INDUSTRIES

Best Practice in Sewage and Effluent Treatment Technologies

Feasibility of using feedlot manure for biogas production

Appendix 18 Stage 2 Refined Options Technical Memo Summary of Capex and Opex

Cleaner Production Assessment in Meat Processing

City of Redlands Wastewater Treatment Plant. Redlands, CA LOCATION: Carollo Engineers; CH2M HILL MBR MANUFACTURER: COMMENTS:

Strategic evaluation of RD&E opportunities for water reuse and recycling at Australian abattoirs

Influence of operating conditions on protein recovery from blood in the meat industry

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia.

Viable Processing For The Future

Water Specialists for the Food & Beverage Sector creating value in water through innovation, creativity and expertise. ovivowater.

WESTDALE WWTP AUGMENTATION AND REUSE FARM. Stephen Sullivan and Jamie Hunt. Tamworth Regional Council

Performance Evaluation of the Moores Creek Advanced Water Resource Recovery Facility

BIOLOGICAL WASTEWATER BASICS

BEEF CATTLE FEEDLOTS: WASTE MANAGEMENT AND UTILISATION

Onsite cogeneration options for commercial meat processing plants

IEA BIOENERGY TASK 37: Energy from Biogas Workshop. Small Scale AD technology for livestock farming in Australia. IEA Bioenergy Task 37

Wastewater Management in the Australian Red Meat Processing Industry

Module- 35. Lec- 35. Dr. ShishirSinha Dept. of Chemical Engineering IIT Roorkee

Palmer Wastewater Treatment Plant 6.7 Alternative 7: Upgrade Existing Lagoons with New Percolation Bed

Duffin Creek Water Pollution Control Plant Technical Information

INFRASTRUCTURE & OPERATION

Lagoon And Wetland Treatment Of Dairy Manure

Sewage Treatment - overview

Wastewater Treatment Pond Systems An Australian Experience

Sanitary Sewer Systems. Sewage Collection System. Types of Sewage 10/12/2016. General Overview

WATER AND WASTEWATER FACILITY CLASSIFICATION APPLICATION FORM

Ample Group Ltd Monitoring Programme Annual Report Technical Report

BIOGAS FUEL POTENTIAL IN MUNICIPAL WASTEWATER TREATMENT

COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS

final report Energy savings calculator and Energy allocation project

Presenter: Kylie Evans 9 October 2014

DISCHARGING WASTEWATER INTO MORRINSVILLE STP WHEN MANAGED TRADE WASTE DISCHARGE REALLY DOES MATTER

Flexible Microscreen Filter. Hydrotech Discfilter

Curlewis Recycled Water Project

Wastewater Treatment Processes

Case Study. Biological Help for the Human Race. BiOWiSH Aqua Improves Nutrient Removal in a Wastewater Treatment Plant - Oberon, Australia

Black Sea / Danube Basin

Application of a novel, cost effective soil moisture technology for effluent irrigation

Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100

EPA Waste Water Discharge Licence Application

Case Study. Biological Help for the Human Race. Industrial Wastewater Treatment at Eastern Seaboard Industrial Estate, Thailand.

WASTEWATER TREATMENT

OPTIMISATION OF THE DORA CREEK IDEA WASTEWATER TREATMENT PLANT

WASTEWATER TREATMENT. Nelson Environmental Inc. Nelson Environmental Inc.

Continuous anaerobic pond desludging PRENV.003

Greenhouse Gas Emissions From Wastewater Treatment A Comprehensive Review

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis

UPGRADING GAZA WASTEWATER TREATMENT PLANT. Gaza City is populated with 550,000 inhabitants and it forms 45% of the Gaza strip population.

Saudi Aramco Efforts in Oily Wastewater Treatment and Reuse

Johns Environmental. Dr Ross Nichols. Birubi Innovation Pty Limited

Industrial Wastewater Pretreatment Challenges at a Beef Processing Facility

Texas A&M Wastewater Treatment Plant 9685 Whites Creek Rd., College Station, TX

ANAEROBIC DIGESTION OF FLUSHED DAIRY MANURE

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES WASTEWATER TREATMENT OPERATIONS DIVISION

City of Elk River Wastewater Treatment Facility Improvements. Achieving Wastewater Treatment Goals

Bioenergy Projects for Agribusiness Bioenergy Australia Biogas Workshop - Gold Coast

ATTACHMENT E.3 EMISSIONS TO SEWER LOCATION OF EMISSION TO SEWER (IE DR-0003) Consent of copyright owner required for any other use.

Chapter 2 Screening Approach and Criteria

Design of a Prototype Sewage Treatment Plant for SHIATS Campus

HELCOM Programme Implementation Task Force (HELCOM PITF) PITF 18/ th Meeting 6.2/5. Tallinn, Estonia 30 October November 2001

Rye Valley Foods August 2006 IPPC Application Attachment E.3.

Management for Technology Pty Ltd. Analysis of information flows and implementation of an e-business solution for Killarney Abattoir

A630 Deephams Sewage Works Upgrade. Strategic Options Review Stage 1 Report. Public consultation version

Rendering cost model instruction manual

WASTEWATER TREATMENT SYSTEM

Milking Center Wastewater: Planning, Design, Construction, Documentation

OPTIMISING WASTEWATER TREATMENT AND REUSE MOUNT ISA A CASE STUDY

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

Application of Covered Anaerobic Lagoons for pre- treatment of Wastewater in red meat and other industries Abstract Keywords: Introduction

CHAPTER 1 - WASTEWATER SYSTEM DESCRIPTION

National University Of Kaohsiung Taiwan. T.Y.Yeh Professor Department of Civil and Environmental Engineering

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

Domestic Waste Water (Sewage): Collection, Treatment & Disposal

ANAEROBIC TREATMENT OF PAPER MILL WASTEWATER

HEAVY INDUSTRY PLANT WASTEWATER TREATMENT, RECOVERY AND RECYCLE USING THREE MEMBRANE CONFIGURATIONS IN COMBINATION WITH AEROBIC TREATMENT A CASE STUDY

CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES WASTEWATER TREATMENT OPERATIONS DIVISION

The Wetland Biofilter System:

RESTRICTED URBAN REUSE OF KONYA (TURKEY) MUNICIPAL WASTEWATER TREATMENT PLANT EFFLUENTS VIA RECLAIMED WATER DISTRIBUTION SYSTEM

Waste water treatment

concep pts and results Heidelberg-Neurott Dipl.-Wirtsch.-Ing. Tosca Zech, Dipl.-Ing. Marius Mohr

Biomass Nutrient Recycling

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES

2017 Annual Performance Report

Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100

Irish Country Meats Camolin

Transcription:

final report Project title: Water Quality Improvement Strategy Project code: P.PSH.0449 Prepared by: GHD Date published: July 2010 PUBLISHED BY Meat & Livestock Australia Limited Locked Bag 991 NORTH SYDNEY NSW 2059 Water quality improvement strategy for a processing site This is an MLA Donor Company funded project. Meat & Livestock Australia acknowledges the matching funds provided by the Australian Government to support the research and development detailed in this publication. This publication is published by Meat & Livestock Australia Limited ABN 39 081 678 364 (MLA). Care is taken to ensure the accuracy of the information contained in this publication. However MLA cannot accept responsibility for the accuracy or completeness of the information or opinions contained in the publication. You should make your own enquiries before making decisions concerning your interests. Reproduction in whole or in part of this publication is prohibited without prior written consent of MLA.

Contents Page 1 Description of the project... 3 2 Overview of water use... 3 3 Wastewater sources... 4 4 Current Wastewater Treatment Process... 4 5 Wastewater Upgrade Options... 5 6 Assessment of Treatment Pond Performance... 6 7 Recommendations... 7 7.1 Modified wastewater treatment plan design criteria... 7 7.2 Reduce water consumption and wastewater discharge... 7 7.3 Irrigation Management Plan... 7 7.4 Incremental Improvements to Wastewater Treatment... 8 7.5 Metering... 8 7.6 Expected Results... 8 Page 2 of 9

1 Description of the project The project involved a meat processing company assessing all potential solutions to improve its current wastewater practices in line with regulatory requirements. This included investigating options for water reuse, which will then improve wastewater systems at the plant. The project also looked at what new technology is available for waste water treatment. Strategic Fit Industry Strategy The MLA/AMPC environment strategy shows water reuse as being a key risk (and opportunity) for the industry. Currently the only solutions available to industry are to buy more land to irrigate waste water onto or to implement expensive waste water solutions. This will provide important baseline data for the industry strategy as well as identifying areas that may require further research. The objectives of the project were to: 1. Review current water use and waste water generation 2. Identify potential innovative waste water solutions 3. Develop a waste water innovation strategy for the company. The scope of this project included: Collation and review of existing information; Assessment of water use and wastewater generation in the works; High level review of existing wastewater treatment plant; Identification of waste minimisation options; Identification of additional treatment requirements; Option analysis; Capital and operating cost estimates; and Provide conclusions and recommendations. 2 Overview of water use In beef processing, water is used to clean cattle before slaughter, wash carcasses, continuously clean and sterilise equipment, convey waste products and in cleaning operations at the start and end of the working day. The site is chemically cleaned everyday. Water is also used to generate steam, cool equipment and provide water for cooling towers. At this site, in 2008, the consumption for production days at 1600 head/day or more was: Average water usage: 4.0 ML/day 80-percentile usage: 4.2 ML/day. At an average daily water consumption of 4.0 ML/day, the water consumption metric is of the order of 8.6 kl/t HSCW. This is well below the average Australian value of 10.6 kl/t HSCW measured in a recent industry survey, but there is still some room for improvement. Page 3 of 9

3 Wastewater sources Wastewater is generated directly from production processes undertaken at the site, including contaminated stormwater originating from non-production areas. Individual streams originate from many sources within the plant, but the main waste flows are associated with the following sources: Cattle yards; Slaughter floor and Boning room; Tripe, offal and intestines processing; Plant cleaning; By-products and rendering plant; Paunch dewatering facilities; Boilers blowdown and wet scrubber; Refrigeration and associated facilities and cooling towers; Biofilter; Truck wash and load out area; Stormwater from stockyards, plant surrounds and gardens. The company estimates the ex saveall discharge volume to be 90% of current consumption per week. Flows between different wastewater ponds are not known with any accuracy. 4 Current Wastewater Treatment Process The company s treatment process consists of some basic primary treatment followed by off-site secondary treatment. Wastewater is captured from all sources (except the hides processing wastewater and amenities) and directed to the primary treatment, where the fats and other solids are separated and taken offsite for composting. The liquid effluent from the contra shear screen enters the save-all tanks. From there, it is pumped through an underground pipeline to the offsite secondary treatment facility. The primary treatment is basic by modern standards for Australian abattoirs. However, there is no evidence that this causes problems in the treatment ponds downstream. The wastewater undergoes a reduction in organics, suspended solids and nutrient levels in the biological wastewater treatment ponds. The primary-treated effluent undergoes the following treatment process: Wastewater is pumped into two similar anaerobic ponds, which operate in parallel. Each anaerobic pond discharges by gravity into a large facultative pond. Effluent from this pond exits through a single discharge point and flows into a further pond, containing pump intakes for an adjacent turf farm; The majority of the effluent enters this pond. The outlet structure is located in this pond. Treated wastewater is managed of in two ways: Approximately 19 ML per annum is pumped across to an adjacent 6 ha turf farm. The remainder is discharged from the third pond into the nearby river. Releases are authorised and regulated under an amalgamated permit issued by EPA. Water issued to the turf farm is measured by in-line flowmeter. Page 4 of 9

Possible incremental improvements might include: Addition of a grit removal device treating the effluent from the lower ante-mortem yards. This would intercept and remove grits and sand prior to their settling in the save-all, which lacks any means to remove them; and Consideration of an appropriate system to recover fat from the slaughter-floor area for rendering (with appropriate upstream screening). Investigate the need for a mixed balance tank to allow cooling of wastewater after screens but before fat removal. Investigate the need to replace the save-all with a dissolved air floatation (DAF) unit. 5 Wastewater Upgrade Options A feasibility study assessed options to upgrade the wastewater treatment plant to improve discharge quality. Waste minimisation strategies were also considered. The company currently uses approximately 4 ML per production day, (approximately 1000 ML per annum) of town water. Wastewater produced from the works is screened and passed through a save-all and then pumped to an off-site treatment facility for further treatment. Currently the majority of the wastewater is discharged into a nearby river and only a small portion of that (Approximately 19 ML p.a.) is used to irrigate an adjacent 6 ha turf farm. Wastewater discharge quality analysis indicated that the site does on occasion not meet some of its discharge water quality requirements. Table 5 gives the summary of the mean water quality established: Three wastewater treatment upgrade options were considered: Option 1: includes the existing anaerobic and facultative treatment ponds combined with High Rate Algal Pond (HRAP), modified settling pond and a cost effective filtration system; Page 5 of 9

Option 2: includes the existing anaerobic and the facultative treatment of the wastewater combined with further aerobic treatment and finally a cost effective filtration system; Option 3: comprises constructing an entire new plant at the site. The process would include a modified primary treatment plant, followed with anaerobic and aerobic treatment and lastly, with tertiary treatment polishing of the effluent. The preliminary cost estimates associated with the recommended options are shown in Table 1 below. Table 1 Treatment Option Summary Although Option 1 is the cheapest option, there are a lot of unknown technical issues that make this approach risky. To confirm Option 1 design assumptions would require extensive large-scale pilot test work run under real plant loading conditions. The preferred approach, at this stage, is to upgrade the wastewater treatment plant is Option 2. This option provides water that meets river discharge limits and is suitable for irrigation. It has a robust and relatively straightforward operation. Option 2 also has benefits of reduced power consumption for nitrification in pond 3 due to pond 2 volatilisation of ammonia in summer. These upgrades would create the following impacts on operations: Additional power supply needs to be sourced from the main power lines (~400m from the ponds). There may be significant additional operating costs associated with sludge disposal, if the sludge cannot be managed through the existing offsite composting facility. The impact of the carbon pollution reduction scheme (CPRS) due to additional power consumption has not been included in the options. 6 Assessment of Treatment Pond Performance Using the BOD concentration of 4,400 mg/l ex the save-all and assuming an even flow split between the ponds, the BOD areal and volumetric loading is 13,200 kg BOD/day on a 7-day basis (e.g. allowing for the no flow weekend). The relatively high loading ensures excellent mixing of the pond contents by biogas generated by the microbial flora and this should ensure that most fine solids remain in suspension until discharged into pond 2. Page 6 of 9

The treatment pond system achieves reductions in the way of: BOD removal is 97%; TSS levels diminish by approx. 95%; and Nitrogen removal averages 74% and phosphorus removal is negligible. The current performance of the ponds is excellent. 7 Recommendations 7.1 Modified wastewater treatment plan design criteria General design preferences for a modified wastewater treatment plant (WWTP) are: Ensure effluent quality requirements are met at the nominated design flow rates and loadings; Operate with a margin sufficient to ensure efficient operation for the life of the plant and equipment; Be simple and robust to operate and maintain; The control system should control the existing and new plant; Ensure that the modified or new WWTP can be integrated into the available land area; Negligible odour production, or provision of odour control; Utilise if possible the existing WWTP or parts of it; and Can be easily adapted in a future upgrade. 7.2 Reduce water consumption and wastewater discharge During this study, the following in-plant modifications were identified which result in less water consumption and wastewater discharge: 1. Decrease the weekend flows (in hand already); 2. Grit and manure removal from the Ante-mortem yards wash wastewater; 3. Hide area- ensure all goes to sewer 4. Metal tote bin washing-water minimisation 5. Paunch / inedibles under slaughter floor 6. Improved blood capture on the slaughter floor 7. Boning room-water is recycled in non processing areas 8. Consider dry transport of raw material to rendering; and 9. Reuse the cooling tower and boiler blowdown for ante-mortem yard wash. Some of these modifications can be done cost effectively (eg items 1, 2, 3 and 4). Implementation of other items (5-7) may reduce nitrogen and phosphorus loads (kg/head) by up to 30 %, however the cost of implementation will be quite high. 7.3 Irrigation Management Plan A high level assessment of irrigation of the wastewater indicated that the site does not currently have sufficient land to meet the wastewater land application guidelines throughout the year. The phosphorus load in the wastewater is the key limitation. To remove further phosphorus to allow sustainable irrigation would require the precipitation of phosphorus and production of large Page 7 of 9

amounts of sludge requiring dewatering and disposal. The costs associated with this would be significant. Therefore, It is recommended that a detailed irrigation management plan be developed to design a sustainable irrigation system. This may require: The confirmation of flow and wastewater characteristics. Assessment of the soil type and condition. Investigation of the groundwater in the region. Topography of land. 7.4 Incremental Improvements to Wastewater Treatment The following future actions are also recommended: Addition of a grit removal device treating the effluent from the lower ante-mortem yards. This would intercept and remove grits and sand prior to their settling in the save-all, which lacks any means to remove them; and Consideration of a system (with appropriate upstream screening) to recover fat from the slaughter-floor area for rendering. Investigate the need for a mixed balance tank to allow cooling of wastewater after screens but before fat removal. Investigate the need to replace the save-all with a dissolved air floatation (DAF) unit. Install better metering of discharges. Conduct more analysis of samples at outlet of the ponds; Continue to identify and reduce high weekend water consumption during non-production weekends; Remove accumulated sludge in pond 2 near the discharge of the anaerobic ponds by suitable method (eg Sludge Rat) to minimise the risk of odours developing. Analysis of soils and MEDLI modelling is required to confirm the land requirements for irrigation. Pursue further detailed engineering on the recommended option to refine the design and increase reliability in cost estimates. 7.5 Metering As a minimum we would recommend installing additional sub-meters to measure water use on: Slaughter floor; Hot water and steriliser water; Boning room; Engine room; Rendering plant; Yards; and Offal room. 7.6 Expected Results By implementing these changes we may expect the following reductions in kg per head may be provided. 15 30 % in water consumption; 15 30 % in wastewater production; 5 25 % of COD and nutrients per head to WWTP; Page 8 of 9

Temperature of wastewater; and Solids and grit load to the save-all. Although the kg per head may reduce, concentrations may remain similar or even increase as water reductions may be higher than nutrient reductions. The benefits of these changes will mean that the save-all will operate more efficiently and reduce fat load to the ponds. Page 9 of 9