Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

Similar documents
Not to be distributed outside of FM Approvals and its affiliates except by Customer

APPROVAL REPORT. Anthony Longabard. Project No: Supplements Project No.: N/A Class: 4451 Product Name:

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT PR Nucor Vulcraft Group

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Expansion Shields

Certificate of Compliance

Product Specification ArmorGuard Barrier System

Freestanding Barriers - Rigid

Calm. C I slept at night.

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

SPECIFICATIONS PORTER No PORTABLE BASKETBALL BACKSTOP SYSTEM (FOR INDOOR OR OUTDOOR USE) WITH FAN FIBERGLASS BACKBOARD

METALWORKS RH215 Faceted Custom Hook-on Panels

Certificate of Compliance

Certificate of Compliance

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

APPROVAL REPORT FB11/FB22, FB33, FB44, AND DOORDAM OPENING BARRIERS FLOOD ABATEMENT EQUIPMENT. Prepared for:

Canopy Assembly Instructions: Post-Supported Super Lumideck (2 3/4" Interlocking deck, 6" Fascia)

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

RAPID Column Formwork For the highest requirements on concrete surfaces and edge formation. Product Brochure Issue 10/2017

APPROVAL REPORT TECHNIWELD USA LLC WELDING BLANKETS AND CURTAINS FOR USE IN HOT WORK OPERATIONS

SOLO 700. One Man Aluminium Tower 3T - Through the Trapdoor Method USER GUIDE

Miller Collective Safety at Height Solutions EPIC ULTRA Barrier System EPIC Post-N-Barrier System EPIC Basic Barrier System

Not to be distributed outside of FM Global except by Customer

INSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS

SECTION CLIMBING WALLS

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

The Kodiak 3200 Seating System by Royal Stewart Ltd.:

VertiGreen Modular Living Wall System Installation Instructions (VGM-06 and VGM-10 Wall Mount)

BoSS SOLO 700. One Man Aluminium Tower EN /4 EN1298-IM-EN 3T - Through the Trap Door USER GUIDE

WEC Manufacturing Phone: (901) Website: Itswec.com

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

TEMPORARY EDGE PROTECTION SYSTEM DESCRIPTION CTS. Combisafe International AB

QuadGuard System. General Specifications. CEN General Specifications

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Stages and Risers. National Public SEATING Corp. Shown NPS Seated Risers

SECTION WATERTIGHT DOORS. A. Horizontal Sliding Flood Barrier with frame and hardware.

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly

CERTIFICATE OF APPROVAL No CF 5158 WHITE ALUMINIUM ENTERPRISES L.L.C.

SHERIDAN SEATING INC.


SECTION TOILET COMPARTMENTS SPEC WRITER NOTES:

SERIES W1S & W2S ACCESS COVERS. With Grating Panels

SafeDeck Supported Scaffold System

Instruction Manual Span Scaffolds

MECHANICAL DOCK LEVELER OWNER S MANUAL

ThermaSteel Corporation ASSEMBLY MANUAL

To Contact PS DOORS:

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17

Evaluation of Tiger Dam Flood Fighting Barrier Revised with Re-Test

SECTION I -- IRONWORK

Approval Standard. for. Flammable and Combustible Liquid Storage Buildings


MECHANICAL LEVELERS. P.O. Box 338 Spring Hill, Tennessee /486/ /251/3382 Fax 931/486/0316

SECTION MECHANICAL EQUIPMENT - GENERAL REQUIREMENTS

TIGER DAM TM FOR FLOOD MITIGATION / LAND BOOMS / OIL SPILL COINTAINMENT

Formwork Direct International. Tel: Heavy Duty Panel System

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

Distriubted by Material Storage Systems, Inc CANTILEVER. Distriubted by Material Storage Systems, Inc

CANADIAN MANUFACTURED PALLET RACKING OUR STRENGTH IS OUR PRODUCT ROLLFORMED RACK

NATIONWIDE SAN ANTONIO SALES & SERVICE CENTER

L SERIES NEBS COMPLIANT STANDBY BATTERY RACKS ASSEMBLY INSTRUCTIONS

PRODUCT SPECIFICATIONS WorkUp Tables

Cantilever Loading Platform Erection Procedures and Guidance Notes

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

Hobby Parking Office HOU/ Proj./ No. 738 Houston, Texas 100% Bid and Construction Documents- Addendum #3, January 27, 2017

Flood Mitigation Solutions

NORTH AMERICAN STEEL INNOVATIVE STORAGE SOLUTIONS OUR S T R E N G T H IS OUR PEOPLE AMERICAN TEARDROP RACK

PHYSICAL BARRIERS MACHINE GUARDS ROBOTIC WORK CELLS PERIMETER OR AREAS GUARDS PHYSICAL BARRIERS

SHERIDAN SEATING INC.

PERI UP Easy * The lightweight and fast frame scaffold for safe working on facades

Section BUILDINGS, SHELTERS, ENCLOSURES

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

NOMINAL SIZE. (mm) 4ft extension ft extension ft extension ft extension ft extension 3720

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION

Smarter. Safer. Leaner.

ENGINEERING INFORMATION

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

SPECIFICATION FOR CI DECKING SYSTEM

SHERIDAN SEATING INC.

INSTALLATION MANUAL. All Types F Series Rev G

SECTION CONCRETE FORMWORK AND ACCESSORIES

SECTION ORNAMENTAL ALUMINUM RAILING

USER'S GUIDE FOR INSPECTION OF DAMAGED STORAGE RACK SYSTEMS DON T WAIT UNTIL IT S TOO LATE!

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: LEED HIMMEL INDUSTRIES, INC. Hamden, Connecticut

Product Guide Specifications SECTION ACCESS DOORS/PANELS

ANSI/FM Approvals March FM Approvals LLC. All rights reserved.

INSTALLING A POUR-IN-PLACE DOCK LEVELER (EH & RR)

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

WARNING. Read and become familiar with this manual BEFORE operating unit.

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Tabulated Data Hydraulic Vertical Shores

NOMINAL SIZE. (mm) 6ft extension ft extension ft extension ft extension 3720

SUPPORT AND ANCHORS SECTION 15090

Transcription:

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT Project No: 3046488 Class: 2511 Product Designation: Name of Listing Company: AquaFence Perimeter Flood Barrier Model V1200 AquaFence USA Inc. Address of Listing Company: 1299 156 th Ave. NE, #150 Bellevue, WA 98007 Customer ID: 140565 Customer Website: www.aquafence.com Prepared by: Reviewed by: Michael Cedrone Engineer Fire Protection Group Brian K. MacDonald Technical Team Manager Fire Protection Group Authorized by: Richard B. Dunne Manager Fire Protection Group October 29, 2013 Date of Approval FM Approvals 1151 Boston-Providence Turnpike PO Box 9102 Norwood, MA 02062 Page 1 of 5

INTRODUCTION 1.1 AquaFence USA Inc. requested Approval of the products listed in Section 1.4 for compliance with the standards listed in Section 1.3. 1.2 This report may be freely reproduced only in its entirety and without modification. 1.3 Standards 1.3.1 FM Approvals Standards 1.4 Listing Title Class Number Issue Date Approval Standard for Flood Abatement Equipment 2510 March 2013 The products will appear in the Approval Guide, an online resource of FM Approvals, as follows: Building Materials Flood Abatement Equipment Temporary Perimeter Barriers Product Designation Barrier Type Maximum Design Water Depth DIOM Manual AquaFence Model V1200 Wall Panels 3 ft. AquaFence Installation, Removal, and Operating Manual, Version 1.2, October 2013. 2 DESCRIPTION 2.1 The AquaFence Model V1200 perimeter flood barrier is a portable wall structure designed to protect the area surrounding a building. The barrier has been performance tested to withstand water depths up to 3 ft. (0.9 m). 2.2 Each model V1200 AquaFence unit is comprised of 2 reinforced plywood panels which are unfolded to form an L-shape. Four aluminum strut braces are used to hold the vertical panel upright. The braces are pre-installed on the horizontal panel and are easily swung out and attached to brackets on the vertical panel. The action of unfolding the panels and installing the braces takes very little time. 2.3 Each model V1200 AquaFence unit is approximately 83 long by 47 wide by 47 tall (2.1m x 1.2m x 1.2m). Each unit weighs about 160 lbs. (73 kg) and is easily carried by three or four men. Multiple units are connected together to create a continuous perimeter barrier. The right side of each vertical and horizontal panel is lined with fiber reinforced PVC membrane material which is attached to the left side of adjacent panels. The free ends of the membrane material are sandwiched between the panel and metal clamps lined along the left side of each unit. Adjustable metal latches are also used to secure the base of the panels together. Page 2 of 5

2.3.1 The panel connections may be slightly shifted to create a maximum angle of 5 degrees. Custom panels are available for 90 degree corners or other situations where an angle of greater than 5 degrees is required. Special side closer adapters are also available if it is necessary to attach the structure to a pre-existing vertical wall. The side closer adapters are directly bolted to the wall. 2.4 The horizontal panel is designed to be positioned facing the water side. The outside edge of the panel is lined with a foam Neoprene gasket material to mitigate seepage underneath the structure. Unlike other flood barriers, seepage actually decreases with greater water depths due to the weight of the water compressing the foam gasket against the ground surface. 2.5 The structure is secured to the ground surface using four anchors along the outside edge of the horizontal panel. Anchors are passed through brackets attached to the end of the panel and then drilled into the ground surface. Different types of anchors are used depending on the ground surface type. 2.6 A debris shield made of additional fiber reinforced PVC membrane material is used to protect the structure from floating debris. Each debris shield covers 2 units and is attached to the top of the vertical panel and the outside edge of the horizontal panel, therefore protecting the aluminum strut bracing components. 3 EXAMINATIONS AND TESTS 3.1 Perimeter barrier performance testing was conducted at the US Army Corps of Engineers Engineering Research and Development Center (ERDC) located in Vicksburg, MS. The testing was completed in August 2012 with successful results. All data is kept on file at FM Approvals. 3.2 Component samples were submitted for examination and testing. The samples were considered to be representative of the product line and were examined, tested, and compared to the manufacturer's drawings. All data is on file at FM Approvals along with other documents and correspondence applicable to this program. 3.3 All testing and analysis considered appropriate was conducted and verified to be in compliance with the Standards defined in Section 1.3. 4 MARKING 4.1 The following information appears on all model V1200 AquaFence units identified within this Report and meets FM requirements: Manufacturer s Logo/Trademark Model Designation Serial # Country of Manufacture The FM Approvals Diamond Mark A copy of the label drawing is attached to this report. Page 3 of 5

5 REMARKS 5.1 Applications of these flood barriers are subject to the limitations specified by the manufacturer and are subject to FM Global acceptance of plans prior to installation at FM Global insured properties. 5.2 This barrier has been evaluated for use in resisting riverine flooding conditions at water depths no greater than 3 ft. (.9 m). 6 SURVEILLANCE AUDIT The facilities at the following locations shall be visited on a routine basis. The facilities and quality control procedures in place have been found to be satisfactory to manufacture product identical to that tested and Approved. A Form 797 shall be submitted to FM Approvals for requesting any additional manufacturing facilities which are not listed below. Design AquaFence Latvia Mezdarzi Pope, Popes pag. Ventspils nov., 3614 Latvia Manufacturing AquaFence Latvia Mezdarzi Pope, Popes pag. Ventspils nov., 3614 Latvia 7 MANUFACTURER S RESPONSIBILITIES 7.1 Documentation that is applicable to this approval is on file at FM Approvals and listed in the Documentation File, Section 8, of this report. No changes of any nature shall be made unless notice of the proposed change has been given and written authorization obtained from FM Approvals. The Approved Product - Revision Report, FM Approvals Form 797, shall be forwarded to FM Approvals as notice of proposed changes. 7.2 The manufacturer is responsible for control of the product marking and installation instructions. 7.3 The manufacturer shall provide installation, operating, and maintenance manuals with each product. 8 DOCUMENTATION FILE All documents pertinent to this Approval are outlined in the Critical Document List attached to this report. 9 CONCLUSION The products listed in Section 1.4 and described in Section 2 have met FM Approvals requirements. Since a duly signed Master Agreement is on file for this manufacturer, Approval is effective the date of this report. Page 4 of 5

PROJECT DATA RECORD: 3046488 ATTACHMENTS: Critical Document List Label Drawing Page 5 of 5

Critical Document List Document No. Revision Level - Version 1.2 Document Title AquaFence Installation, Removal, and Operating Manual - Version 1.2 AquaFence Approval and Changes of Product - Version 1.0 AquaFence Production Manual - Version 1.2 AquaFence Quality System - Version 1.0 AquaFence Proposal of AquaFence Marking Sticker Design 5546-000 04 Main Assembly 5546-001 04 Front Beak Bracket 5546-300 00 Lip for Beak 5546-002 06 Horizontal Canvas Clamp 5546-003 09 Stabilizer Strut 5546-004-01 00 End Stabilizer Strut 5546-005-03 00 V1200 Horizontal Plate 5546-006-08 00 V1200 Vertical Plate 5546-007 04 Top Profile 5546-008 06 Maze 5546-009 03 Strut Bracket 5546-011 03 Pressnut 01 5546-014 00 Ground Anchor 5546-016-01 F2 Canvas Lock Sheet 5546-017 02 Canvas Bracket 5546-018 05 Vertical Canvas Clamp 5546-020 03 Canvas Bracket Perm Horizontal 5546-021 04 Rear Corner Bracket 5546-022 04 Gasket 5546-023-01 X Folded Support 5546-024 00 Element Fixing Clamp 5546-024-B 00 Tube for Element Fixing Clamp 5546-025A 00 Bracket 5546-026 02 Canvas Bracket Perm Vertical 5546-027 03 Element Fixing Hook V2100-18 00 Canvas Clamp Hook 5546-010-01 00 AquaFence V1200 Element: Canvas

012-LV-0000