Wellhead Protection General Guidelines for New Private Domestic Wells

Similar documents
Wellhead Protection General Guidelines for Existing Private Domestic Wells. Wellhead Protection Recommendations for Well Owners:

Publication No. 26: Private Drinking Water Wells Types of Construction

SECTION PROTECTION OF WATER SUPPLIES

Guide for Well Owners

Do some homework before getting your water well system serviced.

Why should you be concerned?

Well Checklist page 1

Worksheet #1 Assessing the Risk of Groundwater Contamination from Drinking Water Well Condition

RESIDENTIAL CROSS-CONNECTION CONTROL

QUONSET DEVELOPMENT CORPORATION QUONSET & LADD WATER SYSTEMS CROSS CONNECTION CONTROL & BACKFLOW PREVENTION POLICY

Troubleshooting Water Well Problems

Elmira Water Board Cross Connection Control Program

Chapter DRINKING WATER

Background. AEM Tier 2 Worksheet Farmstead Water Supply Evaluation. AEM Principle: Glossary

New Braunfels population growth ranks second in U.S. San Antonio Business Journal WHY ASR FOR NEW BRAUNFELS UTILITIES

6.1 Introduction to Wastewater Issues

Healthy Drinking Waters

Checklist for Developing a Corrective Action Plan under the NJDEP Ground Water Rule. (DRAFT September 15, 2015 DRAFT)

CHAPTER 39 REQUIREMENTS FOR PROPERLY PLUGGING ABANDONED WELLS

Upslope from or at grade with pollution sources. No surface water runoff reaches wellhead.

ARTICLE IV CROSS CONNECTION CONTROL AND BACKFLOW PREVENTION

PROPER CARE OF UNUSED WELLS

Shannon Water and Sanitation District Backflow Prevention and Cross-Connection Control Program

Water Treatment NOTES. Cornell Cooperative Extension, College of Human Ecology. Private Household Water Supplies

The Inspection Process for Public Water Supply Wells: Safeguarding your Groundwater Resource

Well Owner Maintenance Practices

Environmental Management Chapter

WATER SERVICE APPLICATION Not to be used for Fire Service

IRRIGATION INFORMATION

DIVISION 5. BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL

Private Wells & Septic Systems

Groundwater Master Plan Update: Emergency Groundwater Supply Analysis & Water Quality Discussion

DIVISION 3. CROSS CONNECTION CONTROL* Sec Definitions.

Wellhead Protection Issues Related to Mining Activities Minnesota Rural Water Conference March 4, 2014

THIS INFORMATION IS PROVIDED BY PLUMAS COUNTY ENVIRONMENTAL HEALTH

Stormwater Pollution Prevention Best Management Practices (BMP s)

TOWNSHIP OF FRANKLIN YORK COUNTY, PENNSYLVANIA ORDINANCE NO

Fact Sheet #1 Reducing the Risk of Groundwater Contamination by Improving Drinking Water Well Condition

BACKFLOW PREVENTION ASSEMBLY INSTALLATION STANDARDS

San Antonio. Water System BRACKISH GROUNDWATER DESALINATION PROJECT. Bill Stein, PG. LBG-Guyton Associates. San Antonio AMTA/AWWA 1

For further. information. contact your. local water. purveyor or the PNWS/AWWA. Cross-Connection. Control Committee. through the.

Some people get most of their water from their own

CHAPTER 32 - WELL ABANDONMENT ORDINANCE OF DUBUQUE COUNTY, IOWA. Adopted September 5, Part 1 Introduction...2

Suggested Best Management Practices (BMPs)

Part 4 CONSTRUCTION OF WELLS AND THE WITHDRAWAL OF GROUNDWATER Purpose. [Ord , -/-/2002, 1]

MODEL ORDINANCE FOR CROSS CONNECTION CONTROL BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF, STATE OF WYOMING:

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 652. UNDERGROUND INJECTION CONTROL

What is backflow prevention?

O K L A H O M * A * S Y S T Home*A*Syst Home Assessment System

Residential Inspection Programs. Presented by: Paul Patterson

Wellhead Management Background. Well Location. 6) Water testing 7) New wells 8) Unused and abandoned wells

Virginia Department of Health Office of Drinking Water (ODW)

Backflow Prevention:The Forefront of Responsible Irrigation

wellcare Information for Home Inspectors: Guide to Evaluating Water Wells Published by

SECTION 13 - EXISTING FACILITIES TABLE OF CONTENTS

EL DORADO IRRIGATION DISTRICT

BROWARD COUNTY ENVIRONMENTAL PROTECTION DEPARTMENT (EPD) MINIMUM CRITERIA FOR MONITORING WELL INSTALLATION AND SAMPLING

TECHNICAL SPECIFICATION

INVESTIGATION RESULTS

OBJECTIVES BACKGROUND INFORMATION SUBJECTS: TIME: MATERIALS: The student will do the following: 1. Define groundwater.

Water Safety Plan Guide Groundwater Abstraction Bores and Wells Version 1, Ref P1.3

RURAL WATER DISTRICT

(Contaminant) Backsiphonage or Backpressure Backsiphonage or Backpressure

CROSS-CONNECTION CONTROL/BACKFLOW PREVENTION

CROSS-CONNECTION CONTROL PROGRAM HARVEST-MONROVIA WATER, SEWER AND FIRE PROTECTION AUTHORITY

Harris County Board of Health Rule For Governing Individual and Non-Public Water Wells

Public Utilities Department Backflow/Cross Connection Informational Meeting February 24, 2004

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 16 SERVICE CONNECTIONS, METERS, AND CUSTOMERS FACILITIES

SECTION 3 CROSS CONNECTION CONTROL

CROSS CONNECTION CONTROL PROGRAM POLICY Adopted March, 1990 Revised October, 2006

wellcare Information for Home Inspectors: Guide to Evaluating Water Wells

Onsite Sewage Treatment Program. Presented by: Ed Melzark SR Environmental Technician / Zoning Administrator Pine County

Septic Systems. A Complete Guide To Understanding How They Work and How To Keep Them Healthy

Coupons. Tips! ODD-EVEN. What s inside. City of Lacey, Washington. for Free Water Saving Items. For keeping hazards out of your drinking water

SANITARY SEWER BACKUP

Golf Course Regulation Compliance Program 2 of 6: Prevent Backflow to Protect Water Sources by Corinne dupreez, MDA

CITY OF SIOUX CITY. BACKFLOW PROGRAM By Tim Higgins Underground Utility Services Field

Any physical connection between a possible source of contamination and any drinking water system piping.

California Groundwater Association An NGWA Affiliate State 700 R Street Suite 200 Sacramento, CA

SUBCHAPTER 1. GENERAL PROVISIONS

PWSID#: PWS Name: Site Visit Date:* System Type: CWS NTNC TNC

C R O S S - C O N N E C T I O N C O N T R O L

(this cover page left intentionally blank)

11.0 HANDLING AND STORING AGRICULTURAL INPUTS

AQUIFERS AND NON POINT SOURCE POLLUTION

JACKSON COUNTY WATER AND SEWERAGE AUTHORITY. Cross-Connection Control Program

Good Housekeeping and Employee Training

DEPARTMENT OF ENVIRONMENTAL QUALITY OIL, GAS, AND MINERALS DIVISION OIL AND GAS OPERATIONS. Filed with the Secretary of State on

Rockwood Water People s Utility District Cross Connection Implementation and Regulations

Basic Septic And Plumbing Maintenance. By: All-Clear Septic & Wastewater Services

FLOWING ARTESIAN WELLS

CHEMIGATION & FERTIGATION:

W R. December 14, Mr. John Dupnik, P.G. Barton Springs Edwards Aquifer Conservation District 1124 Regal Row Austin, Texas 78745

CHAPTER 10 DRINKING WATER

You are your own water manager

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

Design Checklist for EWB-USA Chapters Working on Drilled Well

Virginia Department of Health Office of Drinking Water

How does groundwater get in the earth? Where does it come from?

Transcription:

Wellhead Protection General Guidelines for New Private Domestic Wells Key principles for wellhead protection for private domestic wells are as follows. Proper Location of Well (Proper sanitary control easements) Proper Well Construction Backflow Prevention Keeping Contaminants Away from Well Water Quality Analysis Proper Closure of Abandoned Wells San Antonio City Code mandates that the Groundwater Resource Protection Section of the San Antonio Water System (SAWS) is the permitting authority for all water well activities within San Antonio city limits and SAWS service area. SAWS, Groundwater Resource Protection Section Water Well Permitting Procedures require that all water wells are constructed and completed in accordance with state and local specifications to ensure the protection of our groundwater sources. Proper Well Location and Construction Duties of SAWS Groundwater Resource Protection Section is to: Inspect the property where any water well is to be drilled and refuse the issuance of a permit to drill a well when the proposed location does not meet with all the conditions as referenced under city code and state guidelines. Insure that sanitary control conditions and distance requirements are adhered to. Require that all wells be constructed and cased so that water from one stratum cannot come in contact with water from another stratum. Require a 2-inch annulus between the borehole and the casing from the top of the water bearing formation to the surface. This is to ensure the cement, which fills the annulus, prevents the possibility of any surface contamination. Require the casing to be set in the top of the stratum from which water is to be taken and shall be cemented from the top of the stratum to the surface in place by suitable method approved by the Water Quality Division. Require for Edwards Aquifer wells new standard schedule 40 steel casing to be used. Require for all other wells, a minimum of 40 feet of new schedule 40 steel casing to be used. (Surface to 40 feet.) The SAWS Groundwater Resource Protection Section Phone Number is; (210) 704-7516

Wellhead Protection Recommendations for Well Owners: Keeping Contaminants Away from Well To reduce the chance of contamination of the well, keep the surrounding area free of potential source of contamination such as; Pesticides Herbicides Petroleum products Fertilizer All household chemicals (such as cleaners, solvents, paints, etc.) Animal or fowl enclosure s If you change the oil in your vehicles yourself, be sure to collect the oil in a container and carry it to a collection center for recycling. Never dispose of the oil by dumping it on the ground. Do not mix pesticides near a well. Keep all such activities at least 100 feet from the well. A well owner should inspect their well often to insure it s integrity is maintained. Backflow Prevention Hazards Prevention One of the more hazardous situations that can occur with a private well is the possibility of backflow or back-siphoning. When a well shuts off unexpectedly, such as with a power outage or lightning damage backflow usually occurs. Most private wells have a single check valve that should prevent the water in the column of pipe from falling back into the well, creating suction throughout the home s water system when an unexpected problem arises. Despite this safe guard, the check valve could leak causing the water to flow back into the well. If this happens and the homeowner was using a hose-end device to apply fertilizers or pesticides to the lawn a siphoning effect could be created and the chemical could end up in the homeowners well. Backflow can also occur in lawn sprinkler systems. If one sprinkler is in a low area that has standing water above it, this surface contaminated water could be siphoned into the well. The installation of a simple atmospheric vacuum breaker on each outside hose bib can prevent backflow. For sprinkler systems, the simplest and most common device installed is a double check valve backflow preventer placed between the well and sprinkler system. Injecting chemicals or fertilizers into the sprinkler system is not recommended due to the high degree of hazard to the well and homeowner.

Water Analysis It is recommended that well owners routinely have water from their private wells tested to insure that no contamination has occurred. All wells should be tested at least for bacteria and nitrates. The San Antonio Health Department for a small fee can test for bacteria and nitrates. San Antonio Health Department phone number: (210) 207-8820 Additional suggestions; Always use licensed or certified water well drillers and pump installers when a well is constructed, a pump is installed or the system is serviced. Periodically check the well cover or well cap on top of the casing (well) to ensure it is in good repair. Take care in working or mowing around your well. A damaged casing could jeopardize the sanitary protection of your well. Don't pile leaves or other materials around your well. Keep your well records in a safe place. These include the construction report (State Well Report), as well as the annual water well system maintenance and water testing results. Abandoned Wells Abandoned water wells or wells in deteriorated condition, pose a serious threat to the Edwards Aquifer or any aquifer. Any well that has not been used for a minimum of six consecutive months, is not connected to an active power source and, exists in a deteriorated condition, is defined as an abandoned and must be properly plugged. Never use an abandoned well to dispose of any material Report any or suspect abandoned well to the SAWS Groundwater Resource Protection Section at 704-7516. Questions regarding Wellhead Protection and the Domestic well Call Jim O Connor at 704-7533

Typical Domestic Edwards Aquifer Water Well Sanitary Seal Ground Surface Pressure Tank Water line to the Austin Chalk Surface Sealing Block Pump Drop Pipe Schedule 40 New Steel Casing 2 Inches of Annular Cement Eagle Ford Shale Buda Limestone Submersible Water Well Pump Del Rio Clay Edwards Aquifer

Typical Domestic Glen Rose Aquifer Water Well Upper Glen Rose Formation Sanitary Seal Ground Surface Surface Sealing Block Pressure Tank Water line to the Pump Drop Pipe Well Casing 2 Inches of Annular Cement Lower Glen Rose Formation Drilled Bore Hole Submersible Water Well Pump Hensell Sand Cow Creek Limestone Pine Island Shale