Investigation of leakage current flow through wooden poles structures on overhead distribution system

Similar documents
Reprinted from the Proceedings of the 2001 IEEE/PES Transmission and Distribution Conference and Exposition, Atlanta, Georgia.

Potential and E-Field Calculation Along an Ice- Covered Composite Insulator with Finite Element Method

for Power Distribution

ILMOS Insulator Leakage Current Monitor

Comparison of effects of Various Contaminations on SiR insulators

TESTING PTE EARTHING

Earthing in electrical network purpose, methods and measurement

Journal of Operation and Automation in Power Engineering. Vol. 1, No. 2, Summer & Fall 2013, Pages:

Different Characteristics of Artificially Polluted High Voltage Composite Insulators

Part 4 High Voltage Overhead DISTRIBUTION CONSTRUCTION STANDARDS HANDBOOK

Performance Analysis of 33 kv Polymer and Porcelain Insulators under Various Pollution Conditions at Costal Regions

Part 4 High Voltage Overhead DISTRIBUTION CONSTRUCTION STANDARDS HANDBOOK

The Effect of Severity and Location of Pollution on Leakage Current Characteristics of Porcelain Insulators under Different Humidity Condition

NEW! PUPI Fiberglass Transmission & H-frame Products

CIGRE 16 BRUGGE Partial Discharge and Dissolved Gas Analysis In bio-degradable transformer oil. The University of New South Wales Australia

Panagiotis Charalampidis

PERFORMANCE ANALYSIS OF OVERHEAD PORCELAIN INSULATOR UNDER DIFFERENT CONTAMINATIONS

Evaluation Test Procedures for Distribution Crossarms. Southeastern Electric Exchange November, 2018

Predicting Contamination Flashover of Insulators: Successes and Shortcomings of Tests and Simulations

Effects of Water Content on Dielectric Properties of Mineral Transformer Oil

Dissolved Gas Analysis of Transformer Oils: Effects of electric arc

Elcometer 118/2. Moisture Meter. Operating Instructions

Performance investigation of composite and RTV SIR coated insulators at a coastal test station

Quantitative assessment of the local leakage current in PV modules for degradation prediction

Data Sheet 110kV TD123II dry type outdoor termination

Effect of UV-Rays and Salt Contamination on 33kV Silicon Composite Insulators

Polluted Outdoor Insulators Maintenance and Washing

Mitigating Contamination Related Issues on T&D Equipment. Lily Hoyer Simon Chan

HIGH VOLTAGE INSULATORS. By JP Holtzhausen. Glass. Bushings & hollow core insulators. Cap & pin insulators

Vijendra Singh Parihar 1, Prof. Anil Kumar Kori 2 1

PI Electrical Equipment - tourse PI 30.2 INSULATION. On completion of this module the student will be able to:

Polymer Cutout Testing Recommendations

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION

C Pollution measurement based on DDG method for different type s of insulator profile

Research methodology for the life evaluation of Hollow polymer insulators for High Voltage Applications

Transmission Silicone Insulators Line Post 69 kv to 230 kv

CHAPTER 14 STEELWORK

Selection between indoor or outdoor DC yards D. WU*, U. ÅSTRÖM, L. ARÉVALO, R. MONTAÑO, B. JACOBSON ABB HVDC SWEDEN

CONDITION MONITORING OF INSULATORS UNDER POLLUTION ABSTRACT

Artificial Accelerated Ageing Test of Silicone Rubber Housing Material for Lightning Arrester

Effect of Metal Ring on the Field Distribution of Outdoor Polymeric Insulator

Assessing moisture content of piled woody debris: implications for burning

CHAPTER 6 ENHANCEMENT OF CRITICAL CHARACTERISTICS OF TRANSFORMER OIL USING NANOMATERIALS

ISO Rules Part 500, Facilities Division 502, Technical Requirements Section Bulk Transmission Technical Requirements

Manufacturing and Application of Cage Design High Voltage Metal Oxide Surge Arresters

Development of Composite Line Spacers for Distribution Lines

Title Transmission Line Maintenance Standards. Reference Number PMP 17 - (RIC Standard: EP SP)

A Study of Critical Positive Impulse Flashover of 24 kv Contaminated Insulators

CO 2 Cleaning and Its Effectiveness in Cleaning Energized Medium-Voltage Equipment

INCLINED PLANE TESTS OF COMPOSITE, SILICONE RUBBER AND COMPOSITE SILICONE RUBBER COATED MATERIALS

1/2W, 0805 Low Resistance Chip Resistor (Lead / Halogen free)

Resistance Moisture Meters

Cigré WG C Topics: The selection of insulators with respect to polluted conditions

6C-001 High-Voltage Pin-Type Insulator

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

A Proper Design of Wind Turbine Grounding Systems under Lightning

ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE

DESIGN OF MV OVERHEAD LINES TO MAXIMISE BIRD SAFETY

IN-KILN MOISTURE MEASUREMENT FOR DRY KILNS. Trevor Yasbek AccuDry Annapolis, Maryland

Composite Insulator Components

Electrical Field Simulation for Different Cases of Polymer Insulators Using FEM

Session Three: Accurate Soil Resistivity Testing for Power System Earthing

United Energy EDPR Information and Consultation ES&L Programs

Performance Improvement on Water-cooled Cold-Plate

ESDD PREDICTION OF OUTDOOR POLYMER INSULATORS. Abdelrahman Khaled

Experiment 1: Conservation of Energy and the First Law of Thermodynamics 1

Factors Affecting Current Ratings for Underground and Air Cables

Walk through the associated design considerations associated with transmission line design

High-Voltage Solutions for. Electric Utilities and Utility Contractors. WESCO HigH VOltagE brings together the substation and transmission

Risk assessment of pollution on a 66kV composite insulator using ANSYS

CHAPTER 6 HIGH VOLTAGE ELECTRICAL TESTING RESULTS

fire Charcoat Charcoat IC Passive Protection

Electronic materials and components-inductive components

Substation Grounding Tutorial

EXPERIMENTAL INVESTIGATION OF EFFECT OF UV RADIATION ON FLASHOVER VOLTAGE OF POLYMERIC INSULATORS WITH AND WITHOUT CONTAMINATION

User Instructions for Ligno-VersaTec Moisture Meter

COMPARISON OF THE SPECIFIC SURFACE CONDUCTIVITY AND ESDD APPROACHES TO ASSESSMENT OF SALT DEPOSITS ON NATURALLY POLLUTED INSULATORS. 1.

Gypsum Block Soil Sensors with DataHog Interface

DAMPNESS MEASUREMENT IN CONCRETE FLOORS.

4. POINTS ON SWITCH AND CIRCUIT BREAKER PLATFORM GROUNDING.

* 1 Engr. Muhammad Junaid, 2 Engr. Mehran Tahir, 3 Engr. Kamal Haider, * 4 Engr. Muhammad Aamir

UHS 10kA Arrester. Certified Test Report IEC

Parameters Effecting Substation Grounding Grid Resistance. Dwarka Prasad 1, Dr.H.C Sharma 2

OVERALL EXTERNAL SERVICES COSTS

Testing full-core and partial-core transformers at ambient and cryogenic temperatures

Apparatus for Vacuum Heating of TEM Samples

An Electrical Conductivity Method for Axial Gas and Solid Holdup Determination in Three Phase Fluidized Beds

Metal-plate connections loaded in combined bending and tension

ESDD MEASUREMENTS IN THE POWER SYSTEM OF CRETE

Sn-Pb plating or Tin plating

THE PERFORMANCE OF XLPE WATER TREE RESISTANT INSULATION SYSTEMS AGAINST THE REQUIREMENTS OF DIN VDE /A3

UNS 5kA Arrester. Certified Test Report IEC

SECTION G40 SITE ELECTRICAL UTILITIES 11/10

TECHNICAL SPECIFICATION

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES

Experimental Hygrothermal Study in Wood and Wood-based Materials

DOC No. CMD-III/IS 1554(Pt 2)/1 Date :

Transcription:

Proceedings of the 7th WSEAS International Conference on Power Systems, Beijing, China, September 15-17, 2007 120 Investigation of leakage current flow through wooden poles structures on overhead distribution system KHOI LOON WONG 1 and SACHIN PATHAK 2 School of Electrical and Computer Science RMIT University GPO Box 2476V, Melbourne CBD, Victoria-3000 AUSTRALIA alan.wong@rmit.edu.au 2 http://www.rmit.edu.au/ Abstract: - Insulation degradation leading to leakage current flow through the high voltage insulator is a major problem faced by various power distribution utilities. The excessive leakage current flow into the wooden supporting structures (wooden cross-arm and pole) leads to pole-top fires and subsequently power cut-off. Most prior researchers focused on flashover phenomena of insulators rather than investigation of leakage current leading to pole fire. This paper investigates the continuous current flow path originating from the high voltage conductor to various locations through the wooden pole. The results are of significance to the study of high voltage insulation whereby it extended the study of leakage current into the wooden supporting structures. Experiments were conducted on various locations of wooden pole to detect and track the leakage current flow. Also the moisture contents at these locations were measured to investigate its effect on the leakage current through the wooden pole structure. Key-Words: -Leakage current, wooden pole structure, moisture content, insulator and moisture content 1 Introduction Today, because of their significant advantage over steel cross arms, wooden cross arms and poles are being increasingly used on distribution lines. Their main advantage over steel cross arm include: Very low maintenance cost, better insulation, higher degree of fault protection, easily available and accessible, Cost effective and less weight. However, wooden poles and cross arms still have certain disadvantages like pole top fires problem, maintenance and age. There are number of factors responsible for pole fires in Australia and around the world. They are either electrical causes like leakage current, electrical resistivity or environmental stresses like moisture content and temperature or mechanical stresses like tensile strength. Of these, leakage current and varying moisture content of the wood at certain locations are the main cause of pole top fires on overhead power distribution lines. Fig.1 shows a wooden pole top fire sample supplied by a utility company which will be used in the future research to investigate the cause of fire. Numerous research was carried in Australia and other parts of the world in the late 1940 s find out the cause of pole fire [1,2]. Number of factors which Fig.1 Pole Top Fire Sample cause ignition were discussed but there was no evident experimental results to validate those

Proceedings of the 7th WSEAS International Conference on Power Systems, Beijing, China, September 15-17, 2007 121 findings. Various power distribution companies have experienced pole top fire due to fog, drizzle or heavy dew after spells without heavy rain. Number of alternatives such a painting the wood in the vicinity of metal wood connection with conducting paints have been proposed in the past [3] but none of them have been able to prevent pole top fires around the world. On the other hand, chemical treatment of wooden poles & crossarm has been discussed in the past as pole fire mitigation but there are no evident results of its effect in mitigating pole top fires [3]. In previous studies [4,5], some preliminary results have been reported, however they mainly referred to investigation of leakage current through insulator with very little emphasis on flow of leakage current through wooden structure. So far, information regarding the behaviour of leakage current through wooden poles is rather limited and this paper aims to educate the problem. The objective of the present work is to identify and investigate the various factors which lead to pole fires on overhead power distribution lines. This paper investigates the continuous current flow path originating from the high voltage conductor to various locations through the wooden pole structure. The results are of significance to the study of high voltage insulation whereby it extended the study of leakage current into the wooden supporting structures. Experiments were conducted on various locations of wooden pole to detect and track the leakage current flow. Also the moisture contents at these locations were measured to investigate its effect on the leakage current through the wooden pole structure. Thermal conductivity is a measure of the rate of heat flow through one unit thickness of a material subjected to a temperature gradient. The thermal conductivity of wood is affected by a number of basic factors like density, moisture content, grain direction, structural irregularities such as checks and knots and temperature. Conceptually thermal conductivity increases as density, moisture content and temperature increases. The effect of temperature on thermal conductivity is relatively minor: conductivity increases about 2% to 3% per 10 C. 2.3 Electrical Conductivity The electrical conductivity of wood varies slightly with applied voltage and approximately doubles for each temperature increase of 10 C. It varies greatly with moisture content, especially below the fibre saturation point. As the moisture content of wood increases from nearly zero to fibre saturation, electrical conductivity increases by 10 10 to 10 13 times. Fig.2 below shows a change in electrical resistance of wood with varying moisture content for many Australian species. 2 Properties of wood 2.1 Moisture Content Moisture content if wood is defined as the weight of water in wood expressed as a fraction, usually a percentage, of the weight of oven dry wood. Moisture content exists in wooden cross arms as liquid water (free water) or water vapour in cell lumens and cavities and as water is held chemically within cell walls. In softwoods, the moisture content of sapwood is usually greater then that of heartwood. In hardwoods, the difference in moisture content between heartwood and sapwood depends on the species. 2.2 Thermal Conductivity Fig.2 Variation of logarithmic electrical resistance with moisture content. 3 Experimental Set-up The experimental set-up consists of equipment such as voltage control circuit variac, multimeter, leakage current measurement system connected to PC via a Data Acquisition Card were used. Inside the HV laboratory, a 415V/66kV, 50kVA, single phase transformer, voltage divider(1000:1) to measure the line voltage, sphere gap to protect the equipment from breakdown, resistor bank to limit transformer primary current, pollution chamber and leakage current measurement circuit were used. The experimental setup in the HV laboratory is shown below in Fig.3.

Proceedings of the 7th WSEAS International Conference on Power Systems, Beijing, China, September 15-17, 2007 122 Fig.3 Arrangement of HV polluted insulator and wood testing in the HV laboratory It was made sure all the other switches were in open mode except the one which is in closed mode for measurement of the leakage current at that very location. A well known technique of measuring the voltage across a 100ohm ground resistor is used. The voltage across this ground resistor is proportional to the leakage current flowing through the insulator surface and wooden pole structure. A 30 year old hardwood pine wooden pole and cross arm sample was supplied by the utility company and was used for our laboratory testing. For leakage current measurement through wooden pole, a new technique of inserting steel rod into the wooden pole structure was carried out. The top and bottom part of the wooden pole were drilled with three holes each of similar size as shown in Fig.4. A 15mm steel rod was inserted into each drilled hole, one at a time and connected to the measurement system. This technique was used to capture and track the variation of leakage current flow inside the wooden pole. The switching arrangement consisting of seven switches (S1, S2, S3, S4, S5, S6 and S7) was implemented in the HV laboratory. This was done to ensure leakage current at all seven different locations (one at Insulator rod, three pole top and three pole bottom) was measured individually and one at a time. Fig.5 Testing of wooden pole inside the laboratory Fig.4 Drilled rod arrangement with test points in wooden pole structure for leakage current measurements In the HV laboratory, a 22kV brown pin type insulator shown in figure 5 was mounted on one end of the wooden cross arm to test the single phase line circuit and was connected to secondary of transformer via an ASCR conductor. The insulator was contaminated with a slurry consisting of 40g/l kaolin and variable NaCl according to the IEC 60-1:1989[6,7] to simulate intermediate and heavy degree of contamination. To simulate insulator contamination in coastal regions which are more prone to pole top fire, extra salt was added to the slurry and was sprayed on the insulator surface and a uniform layer of contamination was formed.

Proceedings of the 7th WSEAS International Conference on Power Systems, Beijing, China, September 15-17, 2007 123 The moisture content was measured by using a GE Protimeter Timbermaster meter. Moisture measurements were taken using integral pin electrodes which were pushed into wooden pole surface at six different test point locations i.e. S2, S3, S4, S5, S6 and S7 on either side of wooden pole. The calibration of meter was checked by holding the electrode needles across the exposed wires provided by the meter manufacturer. The moisture measurements were carried out to investigate the effect of moisture content on leakage current at various locations in the wooden pole structure. 4 Results The leakage current waveforms obtained from conducting the experiments are shown Fig. 6 to Fig.12. The first step in measuring the leakage current was a constant voltage of 22kV applied to contaminated insulator sample under normal environmental conditions. Aiming to measure the leakage current on the surface of insulator, the switch S1 was closed while all the other switches were kept open. A leakage current of 447µA magnitude was measured and its waveform was recorded on the PC as shown in Fig.6. Fig.7 Leakage current waveform at pole top right test point This second step was repeated to measure leakage current at remaining test points on the wooden structure and their corresponding switches were operated in the correct manner to avoid incorrect measurements. A high leakage current of 126µA was measured at the top middle test point of wooden structure as shown below in Fig.8. The moisture content of 7.025% was measured at this test point.. Fig.6 Leakage current waveform at insulator surface The second step was to measure the leakage current through the top right portion of wooden pole and was done by inserting a metallic rod into the top right hole of the wooden pole and its corresponding switch S2 was closed while all remaining switches were kept open. A leakage current of 116µA was measured and its waveform is shown in Fig.7. Fig.8 Leakage current waveform at pole top middle test point A leakage current magnitude of 106.9µA was measured at the top left test point of wooden structure as shown below in Fig.9. The moisture

Proceedings of the 7th WSEAS International Conference on Power Systems, Beijing, China, September 15-17, 2007 124 content of 6.625% was recorded at this test point location. 77.54µA was measured at bottom middle test point on wooden pole structure as shown below in below Fig.11 and a corresponding 7.75% of moisture content was measured. Fig. 9 Leakage current waveform at pole top left test point The second step was again repeated to measure the leakage current at bottom right test point on the wooden pole structure (S5 was closed and remaining switches were kept open). A magnitude of 75.86µA was recorded and its waveform is shown below in Fig.10. A moisture content of 7.67% was also measured and is shown in table 1. Fig.11 Leakage current waveform at pole bottom middle test point As can be seen below in Fig.12, leakage current of 79.67µA was measured at pole bottom middle test point by ensuring closure of switch S7 and open state for remaining switches. Moisture content was also measured at this test point and found out to be 7.90%. Fig.10 Leakage current waveform at pole bottom right test point Similarly, by closing the S6 and keeping remaining switches open, a leakage current magnitude of Fig.12 Leakage current waveform at pole bottom left test point For the sake of simplicity, Results obtained from the conducting experiments are shown in Table 1.

Proceedings of the 7th WSEAS International Conference on Power Systems, Beijing, China, September 15-17, 2007 125 Location(Top) Leakage Current (µa) Insulator Rod (S1) 447 Moisture Content (%) Pole Top Right (S2) 116.5 6.925 Pole Top Middle (S3) 126 7.025 Pole Top Left (S4) 106.9 6.625 Pole bottom Right (S5) 75.86 7.67 Pole bottom Middle (S6) 77.54 7.75 Pole bottom Left (S7) 79.67 7.90 Table 1 Leakage current and moisture content measurements at various locations 5 Discussion One of the important parameter that determines the cause of wooden pole top fires is the leakage current flow through the wooden structure. Leakage current measurements were performed at various test point locations on the wooden structure. It is interesting to observe that there is a significant reduction in leakage current measured at top portion as compared to bottom portion of wooden pole. This reduction is attributed to the joule heat losses in the leakage current as it travel from surface of insulator to top and finally through to the bottom of wooden pole structure. It was also found that the higher amount of leakage current was observed at locations with higher moisture content. It has been recognized that increase in moisture content of wooden structure lowers the electrical resistively of wooden pole structures [8]. This closely correlates with the experimental values of the leakage current and the moisture content of wooden pole. It was also observed from the waveform shown in Fig. 8 to Fig. 12, that the leakage current measured at the top portion of wooden poles consist of high frequency components as compared to the bottom porting of the wooden structure. This could be due to the smoldering at the top portion of the wooden pole however this needs further research. through pole top structure as compared to the pole bottom structure. Amount of leakage current flow through the various locations of wooden pole depends on respective moisture content levels. It was found that more leakage current was observed at areas with higher moisture content. It can be concluded that the leakage current decreases in magnitude as it travels from top to the bottom of the pole. This could be due to the heat dissipation and non linear resistance of wood structures. As a result of these conclusions, further research is needed to be done. The influence of age of wood on leakage current flow is still a very new areas and further research will be carried out in the near future. Also further investigation of the effect of dry and wet wooden structure on leakage current will be conducted. References: [1] P. M. Ross, Wood structure burning by leakage currents, Electrical Engineering Journal, vol. 66, pt. 5, pp. 472-474, 1947X1. [2] S. A. Prentice, Report on pole and cross arm fire, State Electricity Commission of Victoria, Australia, internal rept., August 1952. [3] M. Darveniza et al., Line design and electrical properties of wood, IEEE Transactions on power apparatus and systems, vol. Pas-86, no. 11, November 1967. [4] J. Y. Chen and R. J. Chen, Field experience with overhead distribution equipment under severe contamination, IEEE Transaction on power delivery, vol. 11, no. 3, July 1996. [5] A. E. Loxton et al., Recent experience in eskom with pole top fires on 22kV wooden lines, 4 th IEEE AFRICON, vol. 2, pp. 705-710, 24-27 Sept. 1996. [6] IEC 60-1, High voltage test techniques, IEC International standard, 1989. [7] IEC: Artificial pollution test on high voltage insulators to be used in A.C systems, IEC 60507, 1991. [8] A. Gunatilake et al., Use of wooden structures to reduce electric field under EHV transmission lines 39 th International university power engineering conference, UPEC, Vol 1, pp.:223 227, 6-8 Sept. 2004. 6 Conclusions Insulator contamination driven leakage currents do flow on the 22kV wooden pole structures. A higher amount of leakage current leakage was measured