NOTES TABLE OF CONTENTS

Similar documents
User Manual. Biomass moisture meter. humimeter BM1

TABLE OF CONTENTS. Electromatic Equipment Co. Inc. -8- Electromatic Equipment Co. Inc. -1-

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

SAWDUST MOISTURE METER WTR-1E USERS MANUAL

WeighSouth. WBT Toploader Balance

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Limited Product Warranty

Owner s Manual & Safety Instructions

DC-688. When Accuracy Counts

WS 10 Weighing indicator USER MANUAL

Model 292A. Surface Resistance Test Kit. Instruction Manual

Xxxxx Xxxxxx Autoclave Validation Data Logging System

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

DMC When Accuracy Counts

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

Rocker Tool Post ASSEMBLY AND OPERATING INSTRUCTIONS

User s Guide OM240. Linear & Polynomial Conversion. Shop online at omega.com SM

Exceed IRELAND Electronic Postage Computing Scale

EP100 EMERGENCY POWER BANK

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

DICKSON TH8 DICKSON. Temperature & Humidity Chart Recorder Operation. Useful Features. Applications & Product. Specifications. Product.

Royal Sovereign RSL 2701 Laminator

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH

Model HH Signal-Conditioner / Indicator

We greatly appreciate your business and promise to work hard to provide you with the highest level of service at all times.

Limited Warranty. Operation & Installation Guide. Read These Instructions Very Carefully! Home and Office Security Safes MFFS90F75F00F02FE0610 ENGLISH

Process Returns in VOTW

UNI BAR. user manual. ELATION UNI BAR user manual

92831 TEL: (714) FAX:

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

92831 TEL: (714) FAX:

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

RAPiD Safe Setup and Operation

DS-520 Digital Indicator Operation Manual 73366

CMR Quick Start Guide. CMR-5975 Digicast Media Router (MR-S2) Part Number MN-CMR5975-QSG REV. 3

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

Mobile CMMS Quick Start Guide

MAKING MODERN LIVING POSSIBLE INT. Danfoss Link RS. Installation Manual. Danfoss Heating

Table of contents. 1. Introduction

HDMI 4 by 1 Switcher

Please read through the usage and service instructions outlined in this owner s manual before operating the unit. Warnings Diagrams...

7730 ParaGuard Electronic Drawer Safe

ASTM D 991 TEST FIXTURE

Model E100 Gauss Meter

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Model M120 Mini Temperature/Humidity Meter

SIWAREX WP231 Flexible weighing module for S and stand-alone operation. Calibrating SIWAREX WP231 with SIWATOOL V7

Sby SR Instruments, Inc.

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

LC-VS 60 Operation Manual

itemp Anywhere Wireless Sensors and Cellular Gateway User s Guide

Published by ICON Time Systems A subsidiary of EPM Digital Systems, Inc. Portland, Oregon All rights reserved 1-1

PORTION CONTROL SCALE

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

Winzer Corporation 1 Revision: 4.0

Func HS-260 Gaming Headset

Not compatible with the HOBO U-Shuttle. Plot A ± 1 minute per month at 25 C (77 F); see Plot A

Age User s Guide. Dominator Drone

BinMaxx Cloud. User Guide. for Front End Loaders. Air-Weigh Customer Support: PN R0

Everything in its place. OWNER S MANUAL. TRINITY ECOSTORAGE 6-TIER NSF 48 x 18 x 72 WIRE SHELVING RACK w/wheels CHROME Model # TBFC-0907

ALTRONIC RESEARCH, INC.

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

Whitening Lamp. Instructions for use. flaesh.com

MSI Cash Register Version 7.5

TL-600 MOBILE PHASE HEATER

DIGITAL PLATFORM SCALE

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Instructions and E00 Series Sampling Module Extenders

Owner s Manual & Safety Instructions

Owner s Manual.

HOBO Plug Load Logger (UX ) Manual

TABLE OF CONTENTS. Section Paragraph Title Page. ADDENDUM Visual Index Quick Reference. 1 General Information 1-1

OPERATOR S MANUAL Model 56A Prefeed / Dereeler

Introduction TMD Warnings and Cautions Caution: Caution: Caution: Caution: Caution: Caution: Modification

INSTRUCTION MANUAL DAFM3

User Manual. PAT-Stand-16 Docking Station. Release 1.3. November EL-CELL GmbH

Global Water Instrumentation, Inc.

Model M130 Mini Anemometer

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

TSI Model 3063 Thermal Mass Flowmeter

and Shield with Vertical Needle Holder REF 90072

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

117-Bin Wire Shelf Storage Rack

Dual Port isolated USB Charger

User s Guide OM-PR SERIES. Pressure/Temperature Data Loggers

Instruction Manual C20

New Advanced Environmental Air Treatment System

Instruction Manual Pocket scale

Transcription:

NOTES TABLE OF CONTENTS 1.0 Measuring procedure.. 2 2.0 Design of the device 4 3.0 Calibration curves 5 4.0 Activation of the super user function.. 6 5.0 Changing batteries.. 7 6.0 Determination of the material reference moisture.. 7 7.0 Menu level overview 8 8.0 Transfer saved data to the PC 9 9.0 Print saved data.. 10 10.0 Exemption from liability... 11 11.0 Technical data. 11 12.0 Most common reasons for miss readings 12 13.0 Device maintenance instructions.. 12 14.0 Warranty 13-16- -1-

1.0 MEASURING PROCEDURE NOTES 1. Place the scale on an even and sturdy work surface. Place the BM2 in the centre of the scale. Zero the scale to show 0.00kg. 2. Fill the supplied 13 litre bucket with samples taken from varying locations in sample storage. 3. Check that the measuring chamber is completely empty. It is important that no material is left in the measuring chamber when you turn on the device. 4. Switch on the BM2 by pressing the power button for 3 sec. 5. As the next step, please do the self calibration. The word Reinitialize? will show up on your display. Accept by pressing the button. 6. The self calibration is finished when the display shows the measuring window. 7. Fill the measuring device with the sample evenly distributed to ensure reproducible results. 8. Remove material till the next lower weight range is reached. If only a little missing (e.g. 0,10kg) to the next higher level, it should be filled up to that stage. The actual weight is shown on the scale. -2- -15-

NOTES 9. Smooth the material by hand. 10. Select the right calibration curve for your material under test using the buttons or. The weight of the material in the measuring chamber must be the same as the calibration curve. The display shows the water content. 11. If the measure value is blinking, the valid measuring range is exceeded (limits see list on page 5). In this case the accuracy will be decreasing. If you are measuring wood chips, select the next higher weight class and refill wood chips to reach the higher filling weight. 12. To save the results in the save menu press the ( button). The storage was successful when the number in front of the symbol increased. To reach the store menu please press until the appears. 13. To name the saved results press the button. 14. Empty the BM2 and ensure that no material rests are accumulated in the measuring chamber. Measuring process of wooden pellets: Measure wooden pellets with the calibration curve 5.0k Pellets. For this measurement the bucket not has to be full of pellets, you must fill in 5,00 kilograms of wooden pellets every time. Measuring process of dry wood-shavings: Is the 13 litre bucket not big enough for 1,00 kilogram of shavings, the measuring device has to be filled separately (e.g. 2 x 0,50kg). During the filling process the measuring material has to be slightly and constantly compressed in the measuring chamber in order to provide enough place for 1,00kg of shavings. After finishing the filling process, all of the measuring material has to be 5cm below the back case edge. List of calibration curves Pressing the or key in the measuring for at least 3 seconds and a list with all available sorts will appear. Select your sort by pressing or and confirm it with the key. The measurement will continue automatically. -14- -3-

2.0 DESIGN OF THE DEVICE 14.0 WARRANTY Name of calibration curve Water content POWER Button Measuring chamber (inside) Handles Batteries slot (flipside) Electromatic Equipment Co., Inc. (Electromatic) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications thereof. Product failure or malfunction arising out of any defect in workmanship or material in the product existing at the time of delivery thereof which manifests itself within one year from the sale of such product, shall be remedied by repair or replacement of such product, at Electromatic s option, except where unauthorized repair, disassembly, tampering, abuse or misapplication has taken place, as determined by Electromatic. All returns for warranty or non-warranty repairs and/or replacement must be authorized by Electromatic, in advance, with all repacking and shipping expenses to the address below to be borne by the purchaser. THE FOREGOING WARRANTY S IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER S OR SUPPLIER S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE. Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. The duration of any implied warranty, including, without limitation, fitness for any particular purpose and merchantability with respect to this product, is limited to the duration of the foregoing warranty. Some states do not allow limitations on how long an implied warranty lasts but, not withstanding, this warranty, in the absence of such limitations, shall extend for one year from the date of invoice. Electromatic Equipment Co., Inc. 600 Oakland Ave. Cedarhurst, NY 11516 - USA Tel: 1-800-645-7330 / Tel: 516-295-4300 / Fax: 516-295-4399 Every precaution has been taken in the preparation of this manual. Electromatic assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of information contained herein. Any brand or product names mentioned herein are used for identification purposes only, and are trademarks or registered trademarks of their respective holders. -4- -13-

12.0 MOST COMMON REASONS FOR MISS READINGS 3.0 CALIBRATION CURVES Product temperature out of application range Material below 0 C resp. above +40 C (32 to 104 F) may cause faulty measurements. The storage of cold material in a warm storage area usually creates condensed water which may lead to major measuring errors. Not adjusted material under test Let your BM2 adjust to the surrounding temperature of the material for approx. half an hour. A very high temperature difference has a negative effect on the stability of the measurement results. Wrong calibration curve Before you measure your sample, double check the correct selection of the calibration curve. Wrong filling quantity Fill in exactly the right weight (± 0.01kg) of wood chips in the measuring chamber. Wet or mouldy material Frozen measuring material 13.0 DEVICE MAINTENANCE INSTRUCTIONS To provide a long life of your device please does not expose it to strong mechanical loads or heat e.g. dropping it or direct sunlight exposure. Clean your device using a dry cloth. The measuring chamber needs to be cleaned with a dry and soft brush. Any kind of wet cleaning damages the device. The instrument is not rainproof. Keep it in dry areas. When the device is not used for a longer period (6 months) or when the batteries are empty, they should be removed to prevent a leakage of the battery acid. Name of calibration Filling Measuring Material under test curve quantity range 2.0k Woodchips Standard woodchips 2.00 kg 5-30 % 2.4k Woodchips Standard woodchips 2.40 kg 10-35 % 2.8k Woodchips Standard woodchips 2.80 kg 10-40 % 3,5k Woodchips Standard woodchips 3.50 kg 20-50 % 4.5k Woodchips Standard woodchips 4.50 kg 35-60 % 2.8k Coarse WC Coarse woodchips 2.80 kg 10-50 % 3.5k Coarse WC Coarse woodchips 3.50 kg 20-50 % 2.8k Industr. WC Industrial woodchips 2.80 kg 10-50 % 3.5k Industr. WC Industrial woodchips 3.50 kg 20-50 % 2.4k P100 chips Very coarse woodchips 2.40 kg 10-30 % 2.8k P100 chips Very coarse woodchips 2.80 kg 25-45 % 3.5k P100 chips Very coarse woodchips 3.50 kg 35-55 % 2.4k Barks Barks 2.40 kg 10-35 % 2.8k Barks Barks 2.80 kg 25-60 % 5.0k Pellets Pellets made of wood 5.00 kg 5-15 % 1.0k Shavings Shavings 1.00 kg 5-20 % 1.3k Sawdust Sawdust 1.30 kg 10-30 % 2.0k Sawdust Sawdust 2.00 kg 15-60 % 1.0k Miscanthus Miscanthus chopped 1.00 kg 10-25 % 1.5k Corn cob Corn cob (without corn) 1.50 kg 5-45 % Empty 1 For customer calibration Empty 2 For customer calibration Empty 3 For customer calibration Empty 4 For customer calibration reference To test the BM2. Not for use of measuring the moisture! Selection of the right calibration curve: Below you can find advices for selecting the right calibration curve. If you are not sure about the right calibration curve, we recommend to carry out a comparison measurement by kiln drying (CEN/TS14774) once. Woodchips: standard chips of wood (forest wood chips) according to EU-norm CEN/TS 14961 class P16 and P45. Coarse WC: for coarse chips of wood P45 but with fewer fines. If the weight of the filled 13 litre bucket is beyond 2,6 kg, the standard wood chips calibration curves (2,4k resp. 2,0k) have to be used! -12- -5-

Industr. WC: for industrial chips of wood without barks and fines (similar P63) and fresh wood chips P16 & P45 (which are not older than two weeks after cutting down the tree). If the weight of the filled 13 litre bucket is beyond 2,6 kg, the standard wood chips calibration curves (2,4k resp. 2,0k) have to be used! P100 chips: very coarse chips of wood according to class P100. Information: P100 chips are bigger than G100 chips of wood! To avoid filling differences in cause of these coarse chips make more measurements with one sample and note the average! Information: There is the possibility to add further existing calibration curves (e.g. shredder, logging debris wood chips) to your BM2. 10.0 EXEMPTION FROM LIABILITY For miss-readings and wrong measurements and of this resulting damage we refuse any liability. This is a device for quick determination of moisture. The moisture depends on multiple conditions and multiple materials. Therefore we recommend a plausibility check of the measuring results. Each device includes a serial number and the guarantee stamp. If those are broken, no claims for guarantee can be made. In case of a faulty device, please contact Electromatic (www.checkline.com). Definition of wood chips classes The stated numbers refer to the particle size that goes through round gaps of the corresponding diameters (e.g. P16-16 mm). o P16 minimum 80% of the bulk is between 3,15 and 16 mm o P45 minimum 80% of the bulk is between 3,15 and 45 mm o P63 minimum 80% of the bulk is between 3,15 and 63 mm o P100 minimum 80% of the bulk is between 3,15 and 100 mm 4.0 ACTIVATION OF THE SUPER USER FUNCTION 11.0 TECHNICAL DATA Resolution of the display Measuring range Operation temperature Storage temperature Temperature compensation 0.5% water content 0.5 C temperature 5 up to 60% depending on the material 0 C up to +40 C -20 C to +60 C Automatically 2 times - Options Unlock Enter the 4-digit password by using the button (standard is the 4-digit serial number) and confirm by pressing the button. Power supply 4 pcs. 1.5 Volt AA Alkaline batteries (900 measurements) Auto Switch OFF Current consumption After app. 6 minutes 60mA (with light) Display Dimensions Weight 128x64 matrix display, lighted 490 x 290 x 300 mm App. 5.3 kg (including batteries) Degree of protection IP 40 Scope of supply BM2, Measuring bucket 13 Litre 4 x 1.5Volt AA Alkaline Batteries Software LogMemorizer USB interface for PC transfer USB cable -6- -11-

9.0 PRINT SAVED DATA 5.0 CHANGING BATTERIES To print your saved data, connect the device to the printer using the printer cable that was delivered with your device. Carefully loose the protection cap on the BM2. At first plug in the side of the connector with the close plastic casing at the BM2. Then switch on the device. Not till then the other side of the cable has to be plugged in at the printer. Switch on the printer by pressing. Now the green LED is blinking. If it does not blink, please change the batteries and try again. Your new device is provided with batteries. Fitting and changing of batteries: 1. Press with your finger onto the arrow of the battery cap und pull it back. 2. Remove the empty batteries. 3. Put four new batteries in the device. Make sure that the positions of the battery poles are correct. 4. Press down the batteries and close the cap. Press the button at your BM2 until you reach the menu (see image on the right). Choose Print Logs and confirm by pressing. Now you can select if you want to print the last saved measuring series or all saved measuring series (logs). Confirm by pressing out now. again. The selected logs are printed If the battery symbol appears in the measuring window resp. if a critical charge of battery is shown in the status, the batteries have to be changed IMMEDIATELY. If you do not use your BM2 device for a longer period, remove the batteries. For eventual resulting damages we cannot provide any warranty. To save paper, please think of clearing the data storage regularly. Online Print and Online Send Your device supports the function Online Print and Online Send, this can be activated in the menu Options. If an option is active, every newly recorded log will immediately be printed or transferred to the PC after pressing key. 6.0 DETERMINATION OF THE MATERIAL REFERENCE MOISTURE The principle is a comparison measurement with the dehydration method according to CEN/TS 14961:2005. Take the measured sample and weigh it. Dry it out in an oven and weigh it again. Mn Mt % F = 100 Mn M n: Mass with average moisture content M t : Mass of the dried sample %F: Calculated moisture content -10- -7-

7.0 MENU LEVEL OVERVIEW 8.0 TRANSFER SAVED DATA TO THE PC Type selection menu Next calibration curve Previouse calibration curve Power off (3 sec.) Store menu Watch the saved data (logs) Save new value (log) Power off (3 sec.) Main menu Edit Logs Manual Logs Clear Logs Print Logs Last Log All Logs Clear Logs Send Logs Manual Logs Clear Logs Options Status Switch upper Switch lower Open this menu / Enter Overview main menu -8- Keypad symbols Measuring window: Rolling Menu Power ON / OFF Switch upper Switch lower Save Hold Watch the saved data Suppliers data can be added Menu: Options Date / Time Log Time Language Unlock C / F o Userlevel BL On Time Auto Off Time Materialcalib. o Online Send o Online Print Password Reset Enter Switch upper Switch lower Exit Enter numbers Enter letters Next or right Left Yes No Shift OK To send your saved logs to the PC, connect the BM2 to your PC using the USB cable that was delivered with your device. Carefully loose the protection cap on your BM2 and plug in the USB mini B connector. The bigger connector has to be connected to a USB slot on your PC. Start the LogMemorizer software on your PC and switch on your BM2. The data transfer can be started on your BM2 or on the software. Starting the data transfer on the BM2: Press the key until you reach the menu (see image on the right). Then choose Send Logs and confirm by pressing the key. Now choose Manual Logs and confirm with again. All saved logs will be sent to your PC. Starting the data transfer on your PC: Press the button remote control in the LogMemorizer software. A drop-down menu with several options opens (see image below). For transferring the data you can select Import last manual log (the last saved measuring series is transferred) or Import all manual logs (all saved logs are transferred). If you click on one of these menu items, the transfer starts immediately. For the basic adjustments of the software please look through the instructions on the LogMemorizer CD. -9-

BM2 BIOMASS MOISTURE METER OPERATING INSTRUCTIONS