FirePlex mirna Assay. Multiplex microrna profiling from low sample inputs

Similar documents
MicroRNA profiling directly from low amounts of plasma or serum using the Multiplex Circulating mirna Assay with Firefly particle technology

TECHNICAL NOTE. microrna Profiling with FirePlex mirselect: A Technical Overview and Cross-Cytometer Comparison

TaqMan Advanced mirna Assays

TaqMan Advanced mirna Assays

QPCR ASSAYS FOR MIRNA EXPRESSION PROFILING

APPLICATION NOTE. MagMAX mirvana Total RNA Isolation Kit TaqMan Advanced mirna Assays

It s All in the Details (or Small RNA): Simplified and Improved mirna Purification from Tissue

mirna from serum and plasma samples

A robust and sensitive. for profiling of mirnas Life Sciences - Genomics. Stephanie Fulmer-Smentek. Group Manager. Agilent mirna profiling solution

FirePlex mirna Assay V2 Assay Protocol

Evaluation of extraction kits and RT-qPCR systems adapted to high-throughput platform for

From Liquid Biopsy to Result. Fully automated purification, reliable quantification and bisulfite conversion of cell-free circulating DNA

ab FirePlex mirna Assay Core Reagent Kit V2 Biofluid

Quality quantification with qpcr Two-tailed PCR for ultrasensitive detection of micrornas

NUCLEIC ACID PURIFICATION KITS FAST SIMPLE QUALITY CONVENIENT REPRODUCIBLE

From Liquid Biopsy and FFPE Samples to Results

Tech Note. Using the ncounter Analysis System with FFPE Samples for Gene Expression Analysis. ncounter Gene Expression. Molecules That Count

From Liquid Biopsy and FFPE Samples to Results

Product Insert 1 1 Quantified RNA Standards are provided as 100 ng/µl, 10 ng/µl, 1 ng/µl, 100 pg/µl, 10 pg/µl and 1 pg/µl

Reduce microrna RT-qPCR Assay Costs by More Than 10-fold Without Compromising Results

LiquidBiopsy LIQUIDBIOPSY. Automated Rare Template Isolation Platform

Guidelines for Developing Robust and Reliable PCR Assays

HELINI Hepatitis B virus [HBV] Real-time PCR Kit (Genotype A to H)

Technical Review. Real time PCR

ssdna/rna Clean & Concentrator Catalog Nos. D7010 & D7011

Exploring of microrna markers for body fluid identification using NGS

Isolation of total nucleic acids from FFPE tissues using FormaPure DNA

Gene expression microarrays and assays. Because your results can t wait

MAXimum results. Minimum effort.

ab Multiplex mirna Assay Core Reagent Kit - Circulating (crude biofluid)

Compatible with commonly used anticoagulants (i.e., EDTA, heparin, citrate).

ab multiplex mirna Assay Core Reagent Sampler Kit - Circulating

BR-10455A. Automated Multiplexed Gene Expression Profiling Process Solutions. Multiplex Quantitative High-throughput

MAXimum results. Minimum effort.

Rapid Method for the Purification of Total RNA from Formalin- Fixed Paraffin-Embedded (FFPE) Tissue Samples

The Agilent Total RNA Isolation Kit

ab DNA Isolation and Bisulfite Conversion Kit

Establishment and verification of mirnas expression molecules for breast cancer and its distant metastasis Yanhong Gao Associate Professor

Sample & Assay Technologies. Challenging biological samples: stabilization and simultaneous purification of DNA and RNA

TaqPath ProAmp Master Mixes

Axygen AxyPrep Magnetic Bead Purification Kits. A Corning Brand

Identification of cytokine-induced modulation of microrna expression and secretion as measured by a novel microrna specific qpcr assay

Rapid Method for the Purification of Total RNA from Formalin-Fixed Paraffin-Embedded (FFPE) Tissue Samples

Development of quantitative targeted RNA-seq methodology for use in differential gene expression

Changing the world of laboratory developed testing

Methods in virus diagnosis PCR techniques

NimbleGen Arrays and LightCycler 480 System: A Complete Workflow for DNA Methylation Biomarker Discovery and Validation.

ab Multiplex mirna Assay Core Reagent Kit - Circulating (crude biofluid)

ab Multiplex mirna Assay Core Reagent Kit - Circulating (crude biofluid)

Introducing QIAseq. Accelerate your NGS performance through Sample to Insight solutions. Sample to Insight

ab FirePlex mirna Assay V2 Workflow Validation Kit

Simultaneous detection of mirna and mrna on TaqMan Array Cards using the TaqMan Advanced mirna workflow

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Roche Molecular Biochemicals Technical Note No. LC 10/2000

NGEx. High quality sequential extraction of both DNA and RNA from the same tissue specimen. Fast.

Plasma/Serum RNA/DNA Purification Mini Kit Product# 55200

mirna Purification from Plant Tissues: Corn, Soybean and Arabidopsis

Love Bird (Agapornis) Sexing Sex chromosome specific spindlin gene. Advanced Kit. 150 tests. For general laboratory and research use only

QIAseq mirna Library Kit The next-generation in mirna sequencing products

reverse transcription! RT 1! RT 2! RT 3!

Purification of viral nucleic acids from Blood, Tissue and Chewing cords NucleoMag VET Kit on the epmotion 5075t/m

Plasma/Serum Circulating and Exosomal RNA Purification Mini Kit (Slurry Format)

IsoFluxTM. System. The next generation of CTC Analysis is here

ISOLATE II RNA Kits Performance Summary.

M. tuberculosis_mpb64/is611. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

QIAGEN s NGS Solutions for Biomarkers NGS & Bioinformatics team QIAGEN (Suzhou) Translational Medicine Co.,Ltd

ID3EAL Spike-in RNA Kit. Principle, Workflow and Protocol

Isolation of Viral RNA, Viral DNA and Bacterial DNA from Animal Samples

Sample Flexibility for Gene Expression Analysis with the ncounter Analysis System

Chapter 2. High-Throughput RT-qPCR for the Analysis of Circulating MicroRNAs. Abstract. 1 Introduction

Impact of gdna Integrity on the Outcome of DNA Methylation Studies

EXTRACTME Kits, Product Brochure

High Resolution LabChip XT Fractionation of Illumina Compatible Small RNA Libraries using the DNA 300 Assay Kit

IDEAL TM Spike-In RNA Kit. Individual Assays Principle, Workflow and Protocol

Accurate Nucleic Acid Analysis is Critical to Successful Sequencing. Steve Siembieda VP Commercialization November 10, 2016

Complete Success Begins with Sample Quality Control. Agilent 4150 and 4200 TapeStation Systems

ID3EAL mirna Knowledge Panel 384 Targets. Principle and Protocol

Escherichia coli_o104: H4

NanoString Assay Sample Type Assay Input Amount Required Sample Amount/Concentration Total RNA 100ng no less than 150ng, normalized to 20ng/µl

Maize CaMV promoter & NOS terminator (GMO)

NanoString Sample Submission Guidelines

HyperCap, an automatable workflow on the Agilent Bravo B

Purification of Concentrated, High-Quality RNA from Cells and Tissues

Single-Cell. Defy the Law of Averages

mrna Isolation Kit for White Blood Cells for isolation of mrna from human white blood cells Cat. No

Methylamp Coupled DNA Isolation & Modification Kit

Plasma/Serum Circulating Nucleic Acid Purification Mini Kit (Slurry Format)

SANTA CRUZ BIOTECHNOLOGY, INC.

Quick-DNA. DNA from any Sample

Lactobacillus 16S Ribosomal RNA. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Plasma/Serum Circulating and Exosomal RNA Purification Maxi Kit (Slurry Format)

MOLECULAR SOLUTIONS FOR BIOTECHNOLOGY

Gene Expression Profiling of Prokaryotic Samples using Low Input Quick Amp WT Kit

Lab methods: Exome / Genome. Ewart de Bruijn

Genomic DNA quantification assay. Quantification of genomic DNA by real-time PCR

DEFY THE LAW OF AVERAGES. Single-Cell Targeted Gene Expression Analysis

APPLICATION NOTE. The QuantStudio 12K Flex Real-Time PCR System

ncounter Analysis System Digital Technology for Pathway-based Translational Research Molecules That Count NanoString Technologies

Apostle MiniMax TM Technology

FMV 35S promoter (GMO) Advanced Kit. FMV 35S promoter. 150 tests. For general laboratory and research use only

Transcription:

FirePlex mirna Assay Multiplex microrna profiling from low sample inputs

Abstract We introduce a new assay for multiplex microrna (mirna) discovery and verification that enables simultaneous profiling of up to 65 mirnas directly from biofluids, with no need for RNA purification. The platform is built on porous hydrogel particles that maximize mirna capture capacity while being tolerant to factors that commonly foul other platforms, such as serum albumin, complex glycoproteins, heme compounds and heparin. We demonstrate mirna profiling with PCR sensitivity from only 10 µl of crude biofluids or 100 pg of purified RNA, and introduce easy-to-use bioinformatics tools that are integrated with the assay software for fast and efficient data analysis. Overview mirna profiling has tremendous potential for aiding diagnosis and determining prognosis of a broad range of diseases. Numerous studies have demonstrated that mirnas are stable in fresh blood samples and samples frozen long-term 1, making mirnas ideal biomarkers for prospective and retrospective studies. However, several technical challenges must be overcome when using circulating mirnas as biomarkers. These include low abundance of mirnas in biofluids, contaminants introduced during sample preparation and low starting volumes of precious biofluid. We have developed the FirePlex mirna Assay to overcome these challenges and allow biomarker discovery and verification studies directly from biofluids, without need for RNA purification or pre-amplification. mirna detection direct from biofluids and FFPE With the FirePlex mirna Assay robust mirna profiles can be obtained directly from many sample types, including serum, plasma, crude exosomes, cell suspensions, urine, saliva, and FFPEs. Most protocols for isolating RNA from plasma and serum require relatively large sample volume (200 µl) and some enrichment methods can have profound effects on mirna profiles 2. Measurement directly from biofluids using the FirePlex mirna Assay reduces such sample bias, while also lowering required sample input and reducing running time. Designed for discovery and verification studies The FirePlex mirna Assay is a customizable biomarker development platform, designed for both discovery and verification studies. Researchers can select between pre-designed panels for key research areas, larger discovery panels, or design custom panels to detect any mirna from any species, whether annotated in mirbase or not. Assays are read out using a standard flow cytometer.

Assay workflow Protocol Crude biofluid or purified RNA + particle mix Hybridize 60 min, 37ºC Add labeling mix The FirePlex mirna Assay is performed in a 96-well filter plate. The workflow involves six main steps: 1. Incubation of biofluid with digest buffer (45 minutes, not required if starting from purified RNA). Label Amplify 60 min, RT 60 min Elute and add PCR mix 2. Addition of FirePlex particles, hybridization buffer and sample to assay wells, followed by hybridization step (60 minutes). 3. Incubation with labeling buffer (60 minutes). Transfer back to plate 4. Elution of mirnas from particles, followed by PCR amplification (60 minutes). Recapture Report 30 min, 37ºC 15 min, RT Add reporter 5. Transfer back to plate, followed by recapture (30 minutes). 6. Incubation with a fluorescent reporter (15 minutes) and scanning on a standard flow cytometer. Scan Overall, the assay takes 4 7 hours from sample to data, depending on how many samples are processed in parallel and which cytometer is used for scanning. Analyze Figure 1. FirePlex mirna Assay workflow. After capture, labeling and amplification of target mirnas, assay readout is performed using a standard flow cytometer. Data files from the cytometers are interpreted with the FirePlex Analysis Workbench software for analysis and export.

Molecular workflow mirnas are captured by mirna-specific probes embedded in the three-dimensional volume of FirePlex polyethylene glycol hydrogel particles. mirna-specific probes have three binding sites: one for the mirna and two for universal adapter sequences used for amplification. After mirnas are captured, universal adapters are ligated to the mirnas and amplified by PCR with labeled primers (Figure 2). Importantly, mirna capture also acts as a purification step, depleting PCR inhibitors, including heparin, that reduce sensitivity in other detection systems. This makes the assay ideal for the detection of mirna targets directly from biofluid or low quality RNA samples regardless of purity. Following PCR amplification, mirnas are re-hybridized to the probes and detected via fluorescence. The level of fluorescence is quantitative, providing an accurate indication of target level in a given sample. Sample Labeling mix PCR with Universal primers Reporter Universal label region Target-specific region Universal label region mirna capture End-labeling Elution Universal amplification Recapture Report Figure 2. Molecular workflow for the FirePlex mirna Assay. Probes embedded throughout the particle hydrogel have sites for a specific mirna and two adjacent sites for universal amplification. The assay workflow involves direct mirna capture, end-labeling with adapters followed by universal amplification, recapture and reporting with fluorescence. Flexible and customizable panel offering To meet the demands of mirna biomarker discovery and verification, we provide panels to support each stage of mirna biomarker development. For discovery Pre-designed discovery panel contain 400 circulating mirnas identified from peer-reviewed studies. Our discovery panels can be customized for rodent, immunology or plasma/serum markers. For verification Focus panels contain 65 mirna probes specific for research areas such as liver toxicity, oncology, immunology, cardiology and neurology. Alternatively, you can design your own custom panel consisting of 5 65 mirnas, for any species whether they re listed in mirbase or not. See our panel offering: www.abcam.com/fireplexmirnapanels

High detection sensitivity and specificity Sensitivity To demonstrate the high sensitivity of the FirePlex mirna Assay, we measured the number of mirnas detected from varying input amounts of pooled human serum or pooled RNA from human brain, lung and liver samples (Figure 3). As shown, we robustly detect most targets from the 48-plex panel in as little as 10 µl of serum or 100 pg of RNA. Figure 3. Sensitivity and linearity of the FirePlex mirna Assay. Number of target mirnas detected above background using a 48-plex panel in pooled human serum (left) and pooled human brain, lung and liver RNA samples (right). The detection limit is calculated as the sum of 3 standard deviations and the mean value of 3 off-species control probes. Assay linearity across serial dilutions To assess assay linearity, we performed serial dilutions of purified pooled RNA from human brain, lung and liver tissue, and plotted the normalized signal for each mirna against total RNA input (Figure 4). The results demonstrate good signal linearity across multiple targets and RNA input amounts. Figure 4. Three-fold serial dilutions of total RNA purified and pooled from brain, lung, and liver tissue. Data points represent individual targets detected at each dilution. Only targets detected at the top four dilutions (16 in total) were included in this analysis and all data were normalized for display in a common range. The solid line indicates expected signal.

Assay specificity We also assessed specificity of the assay using mirnas let-7a, 7b, 7c and 7d individually spiked into a panel containing probes for 7a, 7b, 7c, 7d, 7e, 7f, 7g and 7i, which differ by one or two nucleotides (Figure 5, top). We observed low cross-reactivity for all off-target probes, typically 2 8%. We obtained similar results for the mir-302 family (Figure 5, bottom). Let 7a-5p Let 7b-5p Let 7c-5p Let 7d-5p Let 7e-5p Let 7f-5p Let 7g-5p Let 7i-5p mirna Sequence Let 7a-5p 100.00% 4.0% 12.0% 5.5% 7.9% 7.1% 2.7% 1.6% Let 7b-5p 1.3% 100.00% 23.1% 0.7% 0.5% 0.5% 0.6% 0.7% Let 7c-5p 14.435.6 19.1% 100.00% 2.0% 2.1% 1.8% 1.7% 1.7% Let 7d-5p 1.6% 1.3% 1.4% 100.00% 1.1% 1.0% 1.0% 0.8% hsa-let-7a-5p hsa-let-7b-5p hsa-let-7c-5p hsa-let-7d-5p hsa-let-7e-5p hsa-let-7f-5p hsa-let-7g-5p hsa-let-7i-5p UGAGGUAGUAGGUUGUAUAGUU UGAGGUAGUAGGUUGUGU G GUU UGAGGUAGUAGGUUGUAUGGUU A GAGGUAGUAGGUUGCAUAGUU UGAGGUAGGAGGUUGUAUAGUU UGAGGUAGUAGAUUGUAUAGUU UGAGGUAGUAGUUUGUACAGUU UGAGGUAGUAGUUUGUGCUGUU mir 302a-3p mir 302b-3p mir 302c-3p mir 302d-3p mir 302h-3p mir 106a-5p mirna Sequence mir 302a-3p 100.00% 2.3% 1.8% 1.8% 0.6% 0.4% mir 302b-3p 1.8% 100.00% 2.9% 1.4% 0.5% 0.5% hsa-mir-302a-3p hsa-mir-302b-3p hsa-mir-302c-3p UAAGUGCUUCCAUGUUUUGGUGA UAAGUGCUUCCAUGUUUUAGUAG UAAGUGCUUCCAUGUUUCAGUGG mir 302c-3p 3.4% 4.3% 100.00% 4.2% 0.7% 0.5% mir 302d-3p 2.99% 2.1% 2.8% 100.00% 0.8% 0.4% hsa-mir-302d-3p hsa-mir-302h-3p hsa-mir-520h-3p UAAGUGCUUCCAUGUUUGAGUGU ACAAAGUGCUUCCCU-UUAGAGU AAAAGUGCUUACAGUGCA GGUAG Figure 5. Assay specificity for families of highly similar mirnas. (Top left) let-7a, 7b, 7c and 7d were spiked into a panel containing probes for 7a, 7b, 7c, 7d, 7e, 7f, 7g and 7i, (top right) sequences for the let family of mirnas, with sequence differences highlighted in red. (Bottom left) mir-302a, mir-302b, mir-302c and mir-302d were spiked into a panel containing mir-302a, mir-302b, mir-302c, mir-302d, mir-302h and mir-106a, (bottom right) sequences for the mir-30 family, with sequence differences highlighted in red.

Integrated bioinformatics tools for mirna discovery and analysis FirePlex Discovery Engine: identify relevant mirnas for any topic Designing a custom panel for mirna discovery or verification requires initial identification of key mirnas in that research area. The FirePlex Discovery Engine searches peer-reviewed publications to find a list of mirnas relevant to the topic, and using natural language processing, ranks them according to relevance, occurrences and journal impact. The Discovery Engine also provides a list of genes that were also referenced in those publications. Figure 6. mirna identification with the FirePlex Discovery Engine. The Discovery Engine searches the scientific literature and identifies the most relevant mirnas for any research topic and species. The FirePlex Analysis Workbench software Proper interpretation of profiling data is a critical component of biomarker development. The FirePlex Analysis Workbench provides a means to decode the particles and transform cytometry files into publication-quality figures in minutes. The software allows interpretation of multiple experiments simultaneously, normalizes data, and simplifies advanced statistical analysis. Organize plate layouts for 100s of samples and multiple experiments Publication quality figures generated automatically, configured easily Heat maps, clusters, bar plots, pairwise comparisons, volcano plots, ranked p-values Annotate, sort and group samples with multiple fields, eg name, age, sex, time Figure 7. The FirePlex Analysis Workbench. The software features tools for organizing and annotating data. Point and click GUI, no scripts, Java-based, runs everywhere, normalization and import of.fcs files.

Conclusions The FirePlex mirna Assay provides a flexible and robust method that enables profiling mirnas in sample types that have previously presented challenges for researchers. The assay is sensitive, specific, and allows high-throughput analysis required for biomarker discovery studies. The use of biofluid digests eliminates a major source of pre-analytical variability while minimizing RNA processing workflow. In addition, the FirePlex Analysis Workbench provides a largely automated means to rapidly visualize and interpret experimental data. References 1. Farina NH, Wood ME, Perrapato SD, Francklyn CS, Stein GS, Stein JL, Lian JB. Standardizing analysis of circulating mirna: clinical and biological relevance. J Cell Biochem, 115, 805 811 (2014). 2. Kim Y-K, Yeo J, Kim B, Ha M, Kim VN (2012). Short structured RNAs with low GC content are selectively lost during extraction from a small number of cells. Mol Cell, 46, 893 895 (2012). www.abcam.com Copyright 2017 Abcam, All rights reserved. FirePlex is a registered trade mark in the United States and is an unregistered trade mark elsewhere.