For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 4 to 36 optical fibers, Gel filling loose tubes (6f/T), FRP central strength member, dry cable core, flame retardant tape, CSTA armor, Double FRLSZH jacket (black). PHSICAL CHARACTERISTICS: Fiber Type 125/250 μm Number of Fibers 4 to 36 Number of Fibers per Tube 6 Fiber Color Code Chart: Number Color 1 Blue 2 Orange 3 Green 4 Brown 5 Grey 6 White Buffer Tube Material PBT Polybutylene Terephthalate Buffer Tube Filling Material Synthetic Thixotropic Gel Buffer Tube Color Code Chart: Number Color 1 Blue 2 Orange 3 Green 4 Brown 5 Grey 6 White STRENGTH MEMBER: Central Strength Member Material Fiberglass Epoxy Rod OVERALL CABLING: Page 1 of 5
Cable Core Wrapping Material Flame retardant tape INNER JACKET: Inner Jacket Material Inner Jacket Nom. Wall Thickness Inner Jacket Color FRLSZH Flame Retardant Low Smoke Zero Halogen 1.0 mm Black ARMORING: Armor Type Armor Material Armor Thickness Corrugated Steel Tape 0.15 mm OUTER JACKET: Outer Jacket Material Outer Jacket Nom. Wall Thickness Outer Jacket Color FRLSZH Flame Retardant Low Smoke Zero Halogen 2.0 mm Black OVERALL DIAMETER: Overall Nominal Diameter 14.8 mm MECHNICAL CHARACTERISTICS: Operating Temperature Range - 40 To + 70 Storage & Transportation Temperature Range - 40 To + 80 Bulk Cable Weight Max. Load for Installation Max. Load for Long Term Application Min Bend Radius for Installation Min Bend Radius for Long Term Application Crush Resistance Impact Resistance Solar Radiation Resistance Cyclic Flexing 283 kg/km 1000 N, 400 N, 20 Cable OD, 10 Cable OD, 3000 N/100mm, APPLICABLE SPECIFICATION AGENC COMPLIANCE: APPLICABLE STANDARDS: Fire Resistant Specification Flame Retardant Specification IEC 60331-25 It remains connected to the optical monitoring apparatus during flame application (750 for 90 min) and a further 15 min cooling period. After test, fiber attenuation increases less than 1.0 db. IEC 60332-3-24 (EN 50266-2-4) IEC 60332-1 (EN 50265-1) Page 2 of 5
Smoke Density Emission IEC 61034-1 40% (minimum light transmission) Halogen Acid Gas IEC 60754-1 < 0.05% ph Value IEC 60754-2 4.3 Conductivity IEC 60754-2 < 10 µs/mm Temperature Index ISO 4589-2 / ASTM D 2863 Min 280 EU RoHS Compliant (/N) SUITABILIT: Suitability Indoor (/N) Suitability - Outdoor (/N) Suitability - Aerial (/N) Suitability Duct (/N) Suitability Direct Burial (/N) Sunlight Resistance (/N) Oil Resistance (/N) Rodent Resistant (/N) Water Resistant (/N) OPTICAL CHARACTERISTICS SINGLE MODE FIBERS Belden Fiber Code Typical Mode Field Diameter @ 1310nm Typical Mode Field Diameter @ 1550nm Cladding Diameter G652.D (OS2) U12 9.2 ± 0.4 μm 10.4 ± 0.5 μm 125 ± 0.7 μm Clad Non-Circularity 0.7 % Core-Clad Concentricity Error Primary Coating Material Primary Coating Diameter Secondary Color Coating Diameter Max. Attenuation @ 1310nm Max. Attenuation @ 1550nm Point Loss @ 1310nm & 1550nm Zero Dispersion Wavelength Max. Slope @ Zero Dispersion Wavelength Max. PMD @ Link Design Value 0.5 μm Acrylate 245 ± 5 μm 250 ± 10 μm 0.36 db/km 0.22 db/km 0.05 db 1302 1322 nm 0.090 ps/(nm 2 km) 0.1 ps/ km Page 3 of 5
Cable Cutoff Wavelength 1260 nm Refractive Index @1310nm 1.466 Refractive Index @1550nm 1.467 MULTI-MODE FIBERS 62.5μm OM1 50μm OM2 50μm OM3 Belden Fiber Code U62 U50 U53 Typical Core Diameter 62.5 ± 2.5 μm 50.0 ± 2.5 μm 50.0 ± 2.5 μm Cladding Diameter 125 ± 1.0 μm 125 ± 1.0 μm 125 ± 1.0 μm Clad Non-Circularity 1 % 1 % 1 % Core-Clad Concentricity Error 1.5 μm 1.5 μm 1.0 μm Primary Coating Material Acrylate Acrylate Acrylate Primary Coating Diameter 245 ± 7 μm 245 ± 7 μm 245 ± 7 μm Secondary Color Coating Diameter 250 ± 10 μm 250 ± 10 μm 250 ± 10 μm Max. Attenuation @ 850nm 3.5 db/km 3.0 db/km 3.0 db/km Max. Attenuation @ 1300nm 1.0 db/km 1.0 db/km 1.0 db/km Min. Overfilled Bandwidth @ 850nm 200 MHz.km 500 MHz.km 1500 MHz.km Min. Overfilled Bandwidth @ 1300nm 600 MHz.km 500 MHz.km 500 MHz.km Point Loss @ 850nm & 1300nm 0.10 db 0.10 db 0.10 db Numerical Aperture 0.275 ± 0.015 0.200 ± 0.015 0.200 ± 0.015 Refractive Index @ 850nm 1.496 1.482 1.482 Refractive Index @ 1300nm 1.491 1.477 1.477 Min. G-Ethernet Transmission Distance@850nm 300 m 550 m 1000 m Min.G-EthernetTransmissionDistance@1300nm 550 m 550 m 600 m PUT-UPS AND COLORS: Item # Fibers Fiber Type Cable Description Put-up * (metre) Page 4 of 5 Jacket Color DK4U12MA004BKAA 4 G652.D LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U12MA006BKAA 6 G652.D LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U12MA012BKAA 12 G652.D LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U12MA024BKAA 24 G652.D LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U12MA030BKAA 30 G652.D LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U12MA036BKAA 36 G652.D LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U62MA004BKAA 4 62.5μm OM1 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK
DK4U62MA006BKAA 6 62.5μm OM1 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U62MA012BKAA 12 62.5μm OM1 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U62MA024BKAA 24 62.5μm OM1 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U62MA030BKAA 30 62.5μm OM1 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U62MA036BKAA 36 62.5μm OM1 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U50MA004BKAA 4 50μm OM2 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U50MA006BKAA 6 50μm OM2 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U50MA012BKAA 12 50μm OM2 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U50MA024BKAA 24 50μm OM2 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U50MA030BKAA 30 50μm OM2 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U50MA036BKAA 36 50μm OM2 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U53MA004BKAA 4 50μm OM3 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U53MA006BKAA 6 50μm OM3 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U53MA012BKAA 12 50μm OM3 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U53MA024BKAA 24 50μm OM3 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U53MA030BKAA 30 50μm OM3 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK DK4U53MA036BKAA 36 50μm OM3 LOOSE TUBE CSTA DOUBLE LSZH JACKET 2000 BLACK * Other put-ups available upon request. Revision Number: 2 Revision Date: 31/12/2014 Copyright 2014 Belden, Inc All Rights Reserved. Although Belden ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment For Wire & amp; Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan2003); Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Page 5 of 5