Construction guideline

Similar documents
Armoured Instrumentation Cables to BS7917

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

The Company by Peter Bröckskes sen. an independent, middle sized company

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152

7. EXTENSION LEADS AND COMPENSATING CABLE

«CABLE T 92» WORKSHOP BALI, INDONESIA JUNE, 1992 POWER CABLES IN TROPICAL ENVIRONMENTS : SYNTHESIS. By L. DESCHAMPS SEE / EDF (France)

Cables for Drag Chains

Introduction. Railway Cables

Cable solutions for Automation & Drives

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING

catalog Copper Wires

U.V resistance UL Sunlight Resistance. Flame retardant IEC

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Una e mpre sa Vi akab l e GLOSSARY.

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

A-5 CABLE TECHNOLOGIES

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

*** Supercedes: BECO E and COM , , & ***

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

Cable Jointing Manual. Jointing Procedures. Module 18. Concentric Cables

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton

Landguard VG Land forces wire and cable to the VG specification

SECTION INSULATED WIRE AND CABLE

WHITE PAPER Flex Life vs Flexibility

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Cable junction boxes with intrinsic fire resistance and insulation integrity

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

CONDUITS AND FITTINGS

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

Electrical Insulating Tapes

THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE

Fixings, bonds and clamps

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE)

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder

High-Tech Copper Products for Solar Systems

CHAPTER 11 CONDUITS AND FITTINGS

Safe, efficient cable protection with high performance polymers

Electrical Conductors

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

ACT. Summary. 1 Introduction. 2 Synoptic. 3 Technical characteristics. 4 Part-numbering system. 5 Arrangements. 6 Receptacles. 7 Plug / Panel seal

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

SURFACE TEMPERATURE SENSORS

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Datasheet RS Pro RS Series Axial Carbon Resistor 1kΩ ±5% 2W ppm/ C RS Stock No:

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

THE PERFORMANCE OF XLPE WATER TREE RESISTANT INSULATION SYSTEMS AGAINST THE REQUIREMENTS OF DIN VDE /A3

Rev. Aug 2017 valid until next revision

voestalpineaustriadrahtgmbh

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Cast resin joint for paper- and plastic insulated cables for low voltage applications till 0,6/1 (1,2) kv.

Accessories. l Nickel or nickel-plated copper unipolar, tripolar and tetrapolar cables for high temperatures

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

Lightning Protection Practice for Large-Extended Photovoltaic Installations

Magnetic float switch For vertical installation Model FLS for nuclear power plants

WIRING PROTECTOR. Edge holder EH-1 series 72 EHS/EHP series 73 LT series 74. Free bush SG series 75. EL free bush EL series 75. Grommet ESG series 76

TECHNICAL SPECIFICATIONS

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36

XLPE CABLE (11KV - Aluminium)

Heat-Shrinkable Tubing

ROLINX Laminated Busbar. Design Rules Version 01 (12/2015)

FLAMABILITY TESTS FOR ELECTRICAL CABLES

Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free

PLASTIC CONDUIT SYSTEMS 1 MADE FROM PVC 4 2 MADE FROM HALOGEN FREE RAW MATERIALS 18 3 WITH ANTIMICROBIAL PROTECTION 30 4 BURIED UNDERGROUND 42

Introduction. Cable Assembly Solutions

K-FLEX. K-FLEX Tapes. for HVAC and industrial application

TECHNICAL SPECIFICATIONS LAYING OF DIFFERENT WIRES & CABLES MOUNTED ON POLES FOR BRPL/BYPL

Highlights of DANA Insulated Sandwich Panels

2 Pfg 1169/ Requirements for cables for use in photovoltaic-systems

Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection

HEW-KABEL/CDT. Technique

July Metal Braids. Screening Braid and Bonding Leads

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

TESTING PTE EARTHING

PASSIVE FIRE PROTECTION PRODUCTS

PREINSULATED PIPE SYSTEMS FOR HOT WATER NETWORKS

FLEXIBLE CONDUITS AND CONNECTORS

CONDUIT SYSTEMS FOR ELECTRICAL WIRES AND CABLES: ANACONDA CONDUIT AND FITTINGS FOR HYGIENIC DESIGN

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

P R O D U C T D E S C R I P T I O N

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

Effect Of Oxidation In Tin Coated Copper Bus Connections

ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)

In order to get the maximum comfort out of a radiant system, it is paramount to go through a precise design phase (ref. UNI EN 1264).

Transcription:

1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS: 2Y : Polyethylene (PE) 2X : Crosslinked Polyethylene (XLPE) Y : Polyvinylchloride (PVC) H : Halogen-free, fire-retardant compound HX : Cross-linked, halogen-free fire-retardant compound METALLIC BARRIERS: K : Lead alloy sheath (L) : Aluminium laminated sheath, also called composite layer sheath (Copolymer coated Alu-tape, laminated to the 2Y- or H-sheath) METALLIC ARMOURINGS: B : Double steel tape armour Q : Galvanized steel wire braid R : Galvanized round steel wire armour INDIVIDUAL SCREENS: OUTER SHEATH MATERIALS: PIMF : PAIR In Metal Foil TIMF : TRIPLE In Metal Foil QIMF : QUAD In Metal Foil OVERALL SCREENS: (St) : Aluminium laminated synthetic foil in contact with a tinned copper drain wire (C) : Copper wire braid (St)C : Aluminium foil + tinned copper wire braid (CuB) : Copper tape 2Y : Polyethylene or High Density Polyethylene (PE or HDPE) Y : Polyvinylchloride (PVC) Yö : Hydrocarbon-resistant Polyvinylchloride (PVC RH) YW : Heat-resistant PVC (max. 90 C) H : Halogen-free, fire-retardant compound v : Reinforced wall thickness of outer sheath CABLING: Bd : Cabling elements forming a bundle and bundles assembled together Bd Z : Bundles identified by means of a numbered tape Bd Si : SIMATIC ring coding of bundels

2/6 2) APPLICABLE STANDARDS - Cable constructions & properties can be based on the following standards: EN 50288-7 NF M87-202 VDE 0815/0816 IEC 60502-1 - The behaviour of the cable when affected by fire can be defined according to the following standards: Scope a) Fire resistance IEC 60331 b) Fire retardance test on cable bundles IEC 60332-3 Cat C / Cat A c) Flame retardance test on single cables or single insulated cores IEC 60332-1 d) Smoke density test IEC 601034-1+2 e) Corrosivity of combustion gases (halogen content...) IEC 60754-2 3) CONDUCTORS According to IEC 60228: * Solid (Class 1) * Stranded (Class 2) * Flexible (Class 5) Selection criteria for the choice of conductor construction: Typical constructions: * Flexibility * Type of Termination / Connection Standard construction Optional construction Conductor size Stranded, cl.2 Diam. R dc @20 C Solid, cl.1 Flexible, cl.5 mm (Ω/km) 0,50 mm 2 7x0,30 mm 0,9 36,0 1x0,8 mm 16x0,20 mm 0,75 mm 2 7x0,37 mm 1,1 24,5 1x0,98 mm 23x0,20 mm 1,00 mm 2 7x0,43 mm 1,3 18,1 1x1,13 mm 31x0,20 mm 1,50 mm 2 7x0,52 mm 1,6 12,1 1x1,39 mm 28x0,25 mm 2,50 mm 2 7x0,66 mm 2,0 7,41 1x1,76 mm 46x0,25 mm Other cross sections and constructions on request. 4) INSULATION MATERIALS * 2Y : Polyethylene (PE) * 2X : Crosslinked Polyethylene (XLPE) * Y : Polyvinylchloride (PVC) * H : Halogen-free, fire-retardant compound * HX : Cross-linked halogen-free, fire-retardant compound * m2x : Mica tape + cross-linked Polyethylene (XLPE) Selection criteria for insulation compounds: * Electrical Properties * behaviour under Fire Conditions * Temperature Rating * Termination Methods

3/6 5) INSULATION WALL THICKNESS & ELECTRICAL PROPERTIES The insulation wall thickness is selected acc. to specified parameters such as: * Applicable standards (see pt. 2) * Voltage rating and related test voltage * Mutual capacitance 6) CABLING ELEMENTS AND INDIVIDUAL SCREENING Cabling elements: - CORE consisting of one insulated conductor - PAIR consisting of 2 stranded cores forming a loop - TRIPLE consisting of 3 stranded cores - STAR-QUAD consisting of 4 stranded cores, 2 diametrically opposed cores forming a pair INDIVIDUALLY SCREENED cabling elements are expressed as follows: * PIMF : PAIR In Metal Foil * TIMF : TRIPLE In Metal Foil * QIMF : QUAD In Metal Foil Standard IDENTIFICATION of cabling elements (others on request): a) Unscreened or overall screened cables: - CORE : WHITE, each core continuously numbered - PAIR : BLACK / WHITE, each core numbered - TRIPLE : BLACK / WHITE / RED, each core numbered - QUAD : BLACK / WHITE / RED / BROWN, 2 diametrically opposed cores numbered with the same number b) Individually screened cabling elements: - Colour code as a) - Identification of each individually screened cabling element by means of a numbered tape The stranding elements need to be balanced-out in order to reduce crosstalk, therefore pairs, triples and quads are twisted with a different pitch.

4/6 7) LAYING-UP OF CABLING ELEMENTS In most of the cases, cables are laid up in concentric LAYERS. For certain cable types, the cabling elements are laid up in BUNDLES (Bd). The bundles can be identified for example by means of a numbered tape (Bd Z) or by SIMATIC ring coding (Bd Si). 8) OVERALL SCREENING Overall screenings are applied to prevent or reduce the external interferences caused by electric or electronic devices like motors, machineries, power cables... Standard solution: * (St) : Aluminium laminated synthetic foil in contact with a tinned copper drain wire Optional solution: * (C) : Copper wire braid * (St)C : Aluminium foil, metallized face in contact with a tinned copper wire braid * (CuB) : Copper tape 9) METALLIC BARRIER AGAINST AGGRESSIVE LIQUIDS When used in petrochemical installations, cables often require an additional metallic covering to make them transversally tight against aggressive liquids or polluted water. * K : - Lead Alloy E sheath acc. to EEMUA 133 or - Kb-Pb Lead Alloy sheath acc. to VDE * (L) : - Aluminium laminated sheath (copolymer-coated aluminium tape laminated to PE outer sheath)

5/6 10) ARMOURINGS Very often, the cables require an armouring as additional protection against mechanical impacts during installation and operation. Those armourings can also fulfill electrical functions as earthing interconnection, screen or interference protection. a) GALVANIZED STEEL WIRE ARMOURING R A concentric layer of galvanized round steel wires, providing over 90 % optical coverage. * GOOD MECHANICAL PROTECTION * GOOD TENSILE STRENGTH * FAIR BENDING properties * GOOD RODENT PROTECTION b) DOUBLE STEEL TAPE ARMOURING B Two layers of galvanized or bare steel tapes, providing 100 % coverage of the cable core. * Diam. of cable core under armouring: min. 8 mm * GOOD protection against PRESSURE & SHOCKS * GOOD RODENT PROTECTION * COST SAVING and light-weight * Armouring providing BEST LOW FREQUENCY INDUCTION-PROTECTION * Not resistant to tractive force

6/6 c) GALVANIZED STEEL WIRE BRAID Q A galvanized steel wire braid providing min. 82 % optical coverage (min. wire diam. 0,3 mm). * GOOD MECHANICAL PROTECTION * FAIR TENSILE STRENGTH * LIGHT WEIGHT * Armouring allowing SMALLEST BENDING RADIUS of cable * No diameter limitation for cable core to be braided 11) OUTER SHEATH MATERIALS * 2Y : Polyethylene or High Density Polyethylene (PE or HDPE) * Y : Polyvinylchloride (PVC) * Yö : Hydrocarbon resistant Polyvinylchloride (PVC RH) * H : Halogen-free, fire-retardant compound * v : Reinforced wall thickness of outer sheath Selection criteria: * Behaviour under fire condition * Temperature rating (during installation and operation) * Site conditions (oil-resistant, termite-repellent...) * PREFERENTIAL COLOURS FOR OUTER SHEATHS: BLACK : Best UV-resistance BLUE : For intrinsically safe circuits GREY : Standard OTHERS : On request The nominal thickness of the outer sheath is in accordance with the applicable standard