How Compliant and Efficient is Your Spectroscopy Workflow?

Similar documents
Spectroscopy Solutions for Pharmaceuticals:

Regulatory Expectations, Standards & Guidelines

UV-Visible Spectrophotometer Calibration. S.ZALI M.Sc. Dept. of Analytical chemistry Razi vaccine serum research institute

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

UNIFI 1.5 : Simplifying Qualification and Validation June 2012

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Cleaning Validation PRODUCT OVERVIEW

NEW. NIST Traceable UV/Vis/NIR Reference Sets USP 857

Qualification of High-Performance Liquid Chromatography Systems

Strategies for Risk Based Validation of Laboratory Systems

LabX Software. Complete Overview, Total Control Smart Laboratory Instrument Software. LabX Software. LabX balance LabX titration LabX connect

ICP Expert software. Technical Overview. Introduction

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Introduction to 21 CFR 11 - Good Electronic Records Management

Certified Reference Materials for Spectroscopy

C191-E018A. Analytical Network Data System Compliant with ER/ES Regulations Progress Configuration of LabSolutions System.

Pharmaceutical Packaging Materials Quality Control and USP Compliance: Agilent Cary 630 FTIR

EU GMP - Annex 11 Computerised systems Versione corrente Nuova versione per commenti (emessa 8 aprile 2008)

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Choosing the Right Instrument Vendor for Complete, Cost-Effective Spectrometer Compliance

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union

á1058ñ ANALYTICAL INSTRUMENT QUALIFICATION

The SaaS LMS and Total Cost of Ownership in FDA-Regulated Companies

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Regulatory Overview Annex 11 and Part 11. Sion Wyn Conformity +[44] (0)

Thermo Scientific SkanIt software for microplate readers. Simplified data acquisition and analysis

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

SmartSpec Plus spectrophotometer

UV/VIS Spectrophotometers Excellence UV/VIS Spectrophotometers UV5Bio UV5Nano

CHAPTER 5 INFORMATION TECHNOLOGY SERVICES CONTROLS

COMPUTERISED SYSTEMS

References Concept. Principle. EU Annex 11 US FDA , (g), (i), 11 Orlando Lopez 2/15/11. Old Annex 11.

2017 by Agilent Technologies Agilent CrossLab Compliance Services

ASQ FD&C GMP Quality Conference

Discussion Paper on the Validation of Pharmacovigilance Software provided via SaaS

Analytical Methods Development and Validation

Computerised Systems. Alfred Hunt Inspector. Wholesale Distribution Information Day, 28 th September Date Insert on Master Slide.

Validation. An Easy to Understand Guide Validating Purified Water Systems

Biochemical Analysis The Lambda Series UV/Vis Spectroscopy

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

ENSURING QUALITY THROUGH COMPLIANCE [ COMPLIANCE ]

MICROCAL PEAQ-DSC BIOMOLECULAR STABILITY ANALYSIS FOR THE REGULATED ENVIRONMENT LABEL-FREE ANALYSIS MICROCALORIMETRY

Tank Scale Service Checklist

A Total Solution for Semiconductor / WEEE RoHS Laboratory

EU Annex 11 US FDA 211, 820, 11; other guidelines Orlando López 11-MAY-2011

UNIFI: The user environment Ken Eglinton Nordic User Training, September 2013

Thermo Scientific Nicolet is10 FT-IR Spectrometer. Complete infrared spectroscopy system. for routine analytical needs

Measurement & Analytics Measurement made easy. Advanced spectroscopy software for quantitative and qualitative analysis Horizon MB FTIR

API Stability Protocols and. Chris Byrne Tasmanian Alkaloids

Computerised System Validation

Metasys for Validated Environments (MVE)

Compliance Response Electronic Records / Electronic Signatures (ERES) for SIMATIC PCS 7 V8.1

An is all it takes to change the way you work..!

Understanding GxP Regulations for Healthcare

REXS. Risk Expert System

TurboMass GC/MS Software

Sample Quantitation. Spectrophotometry 18. Protein Assays 20. Ordering Information 23

Jean Guichard. Introduction to Good Process Record Management (GxP) #: Internet-WP Version: e1.00 /EN

MicroSEQ Rapid Microbial Identification System

quantitate host cell DNA with high sensitivity and throughput resdnaseq Host Cell DNA Quantitation Systems: CHO, E.

Thermo Scientific Qtegra Intelligent Scientific Data Solution. Delivering quality. Driving productivity

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Intelligent Information Management and AI

It s simple. USB data logger testo 184. Easy temperature monitoring and uninterrupted quality documentation in the transportation of pharmaceuticals.

Weigh Dispense Optimization. Rockwell Automation's open, modular weigh and dispense solution.

Paperless recorders and 21 CFR part 11 compliance Videographic recorders

XDS TM Multipurpose NIR-analyser for Laboratories

Implementation Life-cycle SOP

Agilent CrossLab Services and Support Portfolio TRANSFORM YOUR LABORATORY OPERATIONS

High-performance X-ray analysis software

AN ENTIRELY NEW PROCESS- AND EXECUTION- CENTRIC APPROACH TO LIMS IMPLEMENTATIONS

Creating, Managing and Delivering Regulated Content in Pharma. Jim Nichols VP, US Operations & Life Sciences DitaExchange Inc.

Risk-Based Approach to SAS Program Validation

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Siemens PLM Software. SIMATIC IT Unilab. Your next generation LIMS. siemens.com/lims

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Guidance for Industry - Computerized Systems Used in Clinical Trials

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

GLOBAL QUALITY SOLUTIONS PACKAGE INTEGRITY SEAL INTEGRITY LEAK DETECTION

VALIDATION OF CD SPECTROMETERS

Work better, faster and smarter

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

How to support compliance with GAMP 5

18 Spectroscopy 21(11) November 2006

Pharmacopoeial Reference Standards

Intland s Medical IEC & ISO Template

Building a Hosted Statistical Computing Environment: Is it Possible?

General Requirements for the Competence of Testing and Calibration Laboratories

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

IR READY TO GO. Spectrum Two FT-IR Spectroscopy

TECTURA LIFE SCIENCES HIGHLIGHTS

PHARMACEUTICAL TESTING

Flexible. Accurate. Intuitive. AGILENT CARY 100/300 SERIES UV-VIS SPECTRoPHOTOMETERS

10 Things You Should Do Before You Validate Your Next Package

USP Chapter 823 USP 32 (old) vs. USP 35 (new)

Laboratory Information Management System Index

Transcription:

How Compliant and Efficient is Your Spectroscopy Workflow? Focus on your science and meet tough regulatory demands Kevin Grant Cary UV-Vis and Fluorescence Product Manager, Agilent Technologies 1

Components of a compliant and streamlined workflow Compliance Requirements: 21 CFR Part 11 & EU Annex 11 Method validation Audits/ assessments Cleaning validation Process validation System Qualification Metrology A comprehensive enterprise content management system Workflow improvement Training/ education Pharmacopeia Requirements Custom procedure writing (IQOQPQ, SOPs, etc.) Computer system validation (CSV) Regulatory submissions 2

Components of a compliant and streamlined workflow Cleaning validation Compliance Requirements: 21 CFR Part 11 & EU Annex 11 Method validation A comprehensive enterprise content management system Audits/ assessments Workflow improvement Custom procedure writing (IQOQPQ, SOPs, etc.) Metrology Process validation Training/ education Computer system validation (CSV) System Qualification Pharmacopeia Requirements Regulatory submissions 3

The Solution Is not just a box (or a number of boxes!) 4

The Solution A complete workflow solution will: Optimize productivity Stay current with industry standards/best practices Expand lab throughput with the resources you have now Promote global consistency/standardization Minimize regulatory risk Manage workload spikes 5

Components of a compliant and streamlined workflow Using molecular spectroscopy to improve workflow Hardware Qualification Computer system validation (CSV) Pharmacopeia Requirements: e.g. USP <857> Compliance Requirements: US FDA 21 CFR Part 11 & EU Annex 11 A comprehensive enterprise content management system? Custom procedure writing (IQOQPQ, SOPs, etc.) Training/education Method validation Cleaning validation Process validation Metrology Regulatory submissions Audits/assessments 6

Molecular Spectroscopy UV-Vis and FTIR Quick, rugged and reliable Non-destructive Increased uptime Ideal for multi-user laboratories Sample is available for further analysis Ideal screening step before LC or MS Ideal screening step before LC or MS Low cost and easy to use No expensive reagents or consumables 7 9/19/2017

Spectroscopy Applications Drug component or impurity identification Stability studies and drug binding assays Raw material QA/QC Protein analysis Improve productivity and reliability for all spectroscopy applications 8

Rapid and Reliable Full Spectrum Analysis to Improve your Drug Stability Workflows - proteins absorb in UV (280 nm) - but with the full UV spectrum you don t miss anything! Application example: UV-Vis screening Data from 8453 UV-Vis prior absorption to HPLC at 280 nm aggregation index (AI): OD 350 /(OD 280 OD 350 ) 100 Advantages of the Cary 8454: Quick and easy full spectrum analysis Robust instrument with no moving parts Powerful calculation capabilities within the software UV-Vis is non-destructive so samples are recoverable doi:10.1016/j.ejps.2009.06.001 9

Abs Eliminate sample dilution for fast and accurate answers Save time and sample Improve workflow Reduce user errors Reduce waste and save money by getting the right answer every time Typical samples: DNA/RNA (dsdna, oligonucleotides) proteins Reliably measure: Component concentration Sample purity Measurements made using 4 µl BSA protein and the 1 mm path length cap option. mg/ml 10 9/19/2017

Application example: Protein Stability testing Take the strain off your chromatography instruments Experiment: compare innovator monoclonal antibody and its Biosimilar Method: increasing concentrations of a chemical denaturant (guanidine hydrochloride) Protocol: changes in spectra show global conformational changes in the protein structure Cary 60 benefit: ease of use, reliability and rapid results 11 9/19/2017

Fast and confident QA/QC testing of packaging: Increased confidence in API safety Experiment: Improper packaging can cause API degradation. Quick measurements to identify polymers by comparison to standards, and confirm the identity of packaging materials Method: USP 661.1 Agilent Cary 630 FTIR Spectrophotometer family Cary 630 benefit: Robust design based on out-of-lab instrumentation with user-friendly software for error-proof operation Protocol: Lets see 12 9/19/2017

Streamline your analysis in QA/QC with four steps to certainty 1 Open the software 13 9/19/2017

Streamline your analysis in QA/QC with four steps to certainty 2 Software automatically recognizes the correct sampling interface and guides the user through the measurement 14 9/19/2017

Streamline your analysis in QA/QC with four steps to certainty 3 Easy-to-understand display of the data. 15 9/19/2017

Streamline your analysis in QA/QC with four steps to certainty 4 Automatically converts data to an actionable result Programmed for critical action levels with color coded cues (red, green, yellow) Quickly assess results for increased productivity 16 9/19/2017

Streamline your USP<661.1> measurements Pharmaceutical package testing made easy - Improper packaging can cause API degradation - Use transmission or ATR to identify polymers by comparison to standards - Using the Cary 630 this test can be easily and rapidly implemented Certainty via a library search result; The unknown blister polymer, which was searched against the library of known USP 661.1 polymers. The top hit is a nearly perfect match to the correct library material, PVC + SBR copolymer (blue spectrum). 17 9/19/2017

Components of a compliant and streamlined workflow A workflow improvement Hardware Qualification Computer system validation (CSV) Pharmacopeia Requirements: e.g. USP <857> Compliance Requirements: US FDA 21 CFR Part 11 & EU Annex 11 A comprehensive enterprise content management system? Custom procedure writing (IQOQPQ, SOPs, etc.) Training/education Method validation Cleaning validation Process validation Metrology Regulatory submissions Audits/assessments 18

Instrument Performance Testing During installation Tests included in Equipment Qualification Plan Pharmacopeia compliant Routine performance check Instrument test suites included in software Tests are carried out by user Equipment qualification plans for UV-Vis and FTIR systems 19 9/19/2017

USP <857> Ultraviolet-Visible Spectroscopy Pharmacopeia-prescribed instrument performance tests Control of Wavelengths: Six replicate measurements: Hg or D 2 Emission Lines, REE Oxide Solution (e.g. HoO 2 ) REE Glass OR a single measurement using a Diode Array. Mean values & certified value Control of Absorbance: Six replicate measurements. Two or more Absorbance levels e.g. Acidic Potassium Dichromate / Neutral Density Filter Limit of Stray Light Measurements at 190-205nm, 210-259nm, 250-320nm, 300-385nm. Aqueous potassium chloride, aqueous sodium or potassium iodide, acetone, aqueous sodium nitrite (50g/L) Resolution Measure ratio of Absorbance (Toluene in Hexane) at ~ 269 and 266nm Acceptance Criteria NLT 1.3 (2nm spectral bandwidth) 20

USP <857> Ultraviolet-Visible Spectroscopy Automated assurance via the software Six overlaid wavelength scans of holmium perchlorate using an Agilent Cary 60 UV-Vis spectrophotometer and Agilent Cary WinUV software PASSED! Automated applications report the %T measured for each stray light analytical sample, and reports a Pass or Fail against the tolerance for the Agilent Cary 60 UV-Vis. 21

Certified Reference Materials for UV Instrument Qualification ISO 9001, GLP, GMP and international regulatory standards require evidence that a UV instrument is working to specification and is fit for purpose. Certified Reference Materials (CRMs) are used to qualify instrument performance The CRMs required are dependent on the regulatory standards the user is working to Agilent s standard kits include solutions for: Photometric accuracy and precision Wavelength Accuracy and precision Stray Light Resolution 22 9/19/2017

Equipment Qualification: IQ/OQ Analytical Instrument Qualification On Demand Installation Qualification Hardware and Software checking: 1. Verify purchase order documentation ensure that instrument or software matches requirements 2. Preparation and Installation documents gather and record all necessary items 3. System and Installation documentation including reference and user manuals 4. Product Quality Assurance documents evidence the vendor has built and developed the product according to internal standards 5. Start Up Test verify everything starts properly 6. Instrument check demonstrate everything has been installed and connected 23

Compliance in the laboratory Computer system validation All systems (software + hardware) must be fully validated to support data generated for submission to regulatory agencies Validation establishes that a system can consistently and accurately produce results that meet a pre-determined specification Systems must be validated for their intended use and environment 24

Guidelines and regulations for Computer System Validation (CSV). Both must be demonstrably met. And consistently so GAMP5 Risk-based approach/ V model documentation US FDA 21 CFR Part 11 & EU Annex 11 Electronic records/signatures 25

CSV requirements: GAMP5 GAMP5 (Good Automated Manufacturing Practice): conducting verifications is to demonstrate that the system functions as intended. This is accomplished by using the requirements and specifications as an objective standard to which the system is tested. Validation plan (VP) Risk assessment (RA) User requirement specification (URS) Functional requirement specification (FRS) Design/configuration specification (DS/CS) Installation qualification (IQ) Operational qualification (OQ) Performance qualification (PQ) Requirements trace matrix (RTM) Validation summary report (VSR) 26

GAMP5 V Model Validation plan validate Summary Report Risk assessment RA RTM User requirement specification URS validate PQ Performance qualification Functional requirement specification FRS validate OQ SOPs Operational qualification Design/configuration specification DS/CS IQ Installation qualification 27

GAMP5 V Model Validation plan validate Summary Report Risk assessment RA RTM User requirement specification URS validate PQ Functional requirement specification FRS validate OQ SOPs Design/configuration specification DS/CS IQ Installation qualification 28

Guidelines and regulations for Computer System Validation (CSV). Both must be demonstrably met. And consistently so GAMP5 Risk-based approach/ V model documentation US FDA 21 CFR Part 11 & EU Annex 11 Electronic records/signatures 29

CSV Requirements 21 CFR part 11 compliance with 21 CFR part 11 centers on five key (Data Integrity) questions: Is electronic data available? Is electronic data reviewed? Is meta data (audit trails) reviewed regularly? Are there clear segregation of duties? Has the system been validated for its intended use? 30

Compliance Requirements US FDA 21 CFR Part 11 and EU Annex 11 So how do we help prove compliance with 21 CFR part 11? Electronic records security Audit trails Backup Disaster recovery Login/password security Electronic signatures Data integrity 31

Compliance Requirements US FDA 21 CFR Part 11 and EU Annex 11 A modular and upgradable software platform General Purpose (base) software Standard software for the routine or QA/QC laboratory Advanced module Upgrade for the research and/or method development laboratory For method development, macro programming, advanced calculations etc Biochemical Analysis module Upgrade for the biochemical laboratory Dissolution Testing module Upgrade for the product formulation and/or QA/QC laboratory Advanced Dissolution Testing Standard mode Verification& Diagnostics Spectrophotometer driver BioChemical Analysis Kinetics Thermal Denaturation Page 32

Compliance Requirements US FDA 21 CFR Part 11 and EU Annex 11 A modular and upgradable software platform General Purpose Standard software for the routine or QA/QC laboratory Advanced Upgrade for the research and/or method development laboratory For method development, macro programming, advanced calculations etc Biochemical Analysis Upgrade for the biochemical laboratory Dissolution Testing Upgrade for the product formulation and/or QA/QC laboratory Compliance Pack (G5182AA) Upgrade for (OpenLab ECM) server-based FDA 21 CFR Part 11 compliance Advanced Dissolution Testing Standard mode Verification& Diagnostics Spectrophotometer driver BioChemical Analysis Kinetics Thermal Denaturation Page 33

Compliance Requirements Essential compliance features Configurable individual user names and passwords. Log of user name, instrument name, serial number and time stamp stored with all data files and included in all reports All data must have its own audit trail. All actions must be recorded in audit trail: Configuration changes File/folder changes and administration User privilege changes Logon, logoff, system locks 34

Compliance Requirements Dynamic user privileges A single Administrator account is used to : Disable accounts Remove or add privileges Lock files to read only Give users as little or as much access as their roles merit Use preloaded roles or create your own Dynamic groups and privileges makes conforming to CFR21 Part 11 easier 35

Compliance Requirements Automated file indexing and storage A comprehensive enterprise content management system makes organising projects and experiments easy and intuitive Allows the centralised storage of all data types including PDF and MicroSoft Office documents All experimental and auxiliary data can be kept in one secure location 36

Compliance Requirements Secure, centralised content management A comprehensive enterprise content management system provides the ability to allow or deny individual access data in the secure, central location Automate scheduled back-ups or archiving to specific folders, draws, cabinet or locations Make files Read Only to prevent any revision or changes being made 37

Compliance Requirements Easy access to file revisions Full traceability of all data. Data is never over-written but appended and you can access any version of the file from the original to the latest revision Easy-to-follow visible display of the number of revisions within the content manager Every revision can be easily loaded and checked or amended (if you have the authority) 38

Compliance Requirements US FDA 21 CFR Part 11 and EU Annex 11 Well-designed software and hardware enables an auditor to recreate the sequence of events that occurred at the time the result (or record) was generated using the electronic (meta) data: WHO performed the analysis? WHAT equipment was used to perform the analysis? WHEN was the analysis performed? WHY was the analysis performed? WHERE is the electronic (meta) data is stored? 39

Audits/assessments A complete compliance solution will offer experts to help Perform the audit Review current processes, SOPs, and systems Benchmark against industry standards/best practices Perform risk/gap analysis Develop an audit report Record findings/observations Make recommendations Suggest next steps 40

Components of a compliant and streamlined workflow Cleaning validation Compliance Requirements: 21 CFR Part 11 & EU Annex 11 Method validation A comprehensive enterprise content management system Audits/ assessments Workflow improvement Custom procedure writing (IQOQPQ, SOPs, etc.) Metrology Process validation Training/ education Computer system validation (CSV) System Qualification Pharmacopeia Requirements Regulatory submissions 41

For more information Contact your local Agilent representative or visit http://www.agilent.com Webinar series Applications, brochures, flyers Product details Technology videos Compliance tools and services 42 9/19/2017