Rosemount 9901 Chambers for Process Level Instrumentation

Similar documents
Rosemount Differential Pressure Level Solutions. Keeping You a Step Ahead

Flow Through Toroidal Conductivity Sensor

Rosemount Annubar Flowmeter Series. The Value of Innovation, Realized

Model B. Thermostatic Control Valves. Typical applications

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

Model B. Thermostatic Control Valves. Typical applications

KLINGER Ballostar KHE: This ball valve offers more

KTM METALTITE BALL VALVES FLOATING AND TRUNNION TYPE

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

NELES TRUNNION MOUNTED, BALL VALVES, FULL BORE, SERIES X

Rosemount 405 Compact Orifice Primary Element

HIGH SEAL ULF Live Loaded Packing System

IS First edition

Baumann 24000F Wafer Body Control Valve

SEWER FORCE MAIN HDPE PIPE

Fisher EZ Sliding-Stem Control Valve

2-Finger-Parallel-Gripper RH

Operating Instructions

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

2-finger angular gripper SGB 32-50

Cast Steel Bolted Bonnet Stop Check Valves Sizes: 2 thru 14 Pressure Class: 150 thru 1500

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTIONS MAGNETIC LEVEL GAUGE

Flow Rate Measurement In Emissions Monitoring

Emerson Process Management

ASME B31.3 Process Piping. 19. What s Different in B31.1

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

1301 Series High-Pressure Regulators

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Process Inline Filter, Change-Over

brands you trust. Tufline Lined Ball Valves

289 Series Spring-Loaded Relief Valves

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Z5033 E3 Ball joint adapter Mounting instructions

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves

Bateau, Crucible and Timpani Vessels Installation and User Guide

NAVSEA STANDARD ITEM. 2.1 S9086-RJ-STM-010/CH-504, Pressure, Temperature and Other Mechanical and Electromechanical Measuring Instruments

SECTION MECHANICAL EQUIPMENT - GENERAL REQUIREMENTS

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Z5377 E6 Swivel bracket Mounting instructions (1.2 EN)

289 Series Spring-Loaded Relief Valves

SIGRAFLEX UNIVERSAL. Sealing Sheet Made from Impregnated Graphite with Perforated Stainless Steel Sheet Reinforcement

Z5378 E6 Horizontal bracket Mounting instructions (1.0 EN)

LOAD BEARING ROLLER ASSEMBLIES Engineering Data Installation Notes

Immersion Assembly for ph and Redox Sensors DipFit P CPA 140

SCAFFOLDING RUNWAY SYSTEM

DIN 3015 CLAMPS B1-1 PN# / / ACC

Model # 158-P4. 12/12/2013 Page 1 of 11

Worcester Controls E51/52. Enviro-Safe High Integrity Flanged Ball Valves

4 1 /2 MARK 73-5 AMERICAN FLOW CONTROL. It s What We Know. AMERICAN-DARLING FIRE HYDRANT AMERICAN-DARLING 4 1 /2 MARK 73-5 FIRE HYDRANT


Model # 922-S4. 12/18/2013 Page 1 of 8

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

The Pressure Equipment Directive 2014/68/EU. Photo: nostal6ie/ Shutterstock

Weir Specialty Pumps. WEMCO Torque-Flow

Fisher A11 High-Performance Butterfly Valve, NPS 30-72

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Series 2000PV Mechanical Joint Restraint for PVC Pipe

Regulating valves REG 6-65, REG-SS 15-40

Note: Above dimensions will vary due to manufacturer s tolerances. Metric sizes also available.

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

ARI-STEVI 440 / 441 (DN15-250) Control valve - straight through With pneumatic and electric actuators

Ugitech Stainless steel solutions for the oil and gas industry

Run with higher performing, more versatile flow control.

Z5043 MAX Horizontal bracket Mounting instructions

Class III Pipes Fittings (Dy 500 mm)

SECTION TAPPING SLEEVES AND VALVES

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

OPTIMASS 7400 Technical Datasheet

Section 906. STRUCTURAL STEEL

CROSBY H-SERIES DIRECT SPRING SAFETY VALVES

PVC-C metric Fittings

Surface Protection Systems

Features PAGE 1-2. Wide Range Restrained End Cap

Sept Harmer SML Cast Iron Soil & Waste Drainage Technical Submittal Document

Sample Report: ½ Tri-Clamp Flange Connection

A Comparison: ASME B31.1 Power Piping versus ASME B31.3 Process Piping

INTERNATIONAL STANDARD

NUFLO Liquid Turbine Flow Meters

d n g a n a ck a tio cia lica Filters ctio 3 S ctio n n 3 T ctio 2 S ctio 2 T ctio 1 S d C ctio 1 T d C ria 904L rie e S Ordering Number Description

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

FPD190 Differential pressure restriction orifice plates

BRITESTREAM LED NICHE LIGHT

American Metal Specialties, Inc.

PTFE BELLOWS POLY FLUORO LTD. POLY FLUORO LTD.260A. Bommasandra Industrial Area, Hosur Road, Bangalore TECHNICAL SPECIFICATION

Metal Seated Ball Valves

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

Butterfly Valves - Figure 611 & 612

Installation instructions LORO-DRAINJET. siphonic scupper drainage system with clamping flange, without roof penetration

Experience In Motion MPT. Self-Priming, Solids-Handling Pump

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

KÖNIG + CO. FORMING KNOW-HOW

SGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products

IMAGE INDUSTRIES INC. STUD WELDING CATALOG. Attachment Systems Cold Formed Parts Assemblies

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Johnson. We now offer a real step forward in reliability with our newly designed riser pipes.

Cryogenic Metal Seated Butterfly Valves

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS

Transcription:

Reference Manual Rosemount 9901 Chambers for Process Level Instrumentation

Reference Manual Safety instructions These safety instructions are to be read and used in conjunction with the manual of the measuring instrument. Read this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing or maintaining this product. Failure to follow these installation guidelines could result in death or serious injury. Process leaks could result in death or serious injury. Definitions Ps= Maximum allowable chamber pressure (in psi or bar) at stated temperature Pt = Chamber test pressure (in psi or bar) Ts max = Maximum allowable chamber temperature (in F or C) Ts min = Minimum allowable chamber temperature (in F or C) Pressure equipment directive (PED) The PED-approved 9901 (model codes 9901*1 and 9901*5) is designed and manufactured to comply with modules B1+D of the Pressure Equipment Directive 97/23/EC. It carries a CE mark and has a Declaration of Conformity to show compliance with the Directive. Under the Pressure Equipment Directive, the PED-approved 9901 is classified as Category III Piping. The PED-approved 9901 is designed for use with unstable gases and liquids within Groups 1 and 2. Instructions It is the responsibility of the installer/user of this equipment to ensure: The product is installed and used by suitably trained personnel in accordance with all relevant Local and National regulations and codes. Safe working practices for the media and process concerned are followed during installation and maintenance. The materials of construction are suitable for the application. See Table 1. The pressure and temperature limits for this chamber are not exceeded, if necessary by the use of suitable safety accessories. See Table 5. The Pt and Ps limits for each attached instrument are not exceeded. Refer to the instrument manual for this data. All Rosemount supplied installation fixing bolts are used where applicable, and are only replaced by exact equivalents. On all other flanges, the correct quantity, size, and strength of bolts (clamp type) are used. All fasteners are evenly tightened to the correct torque. See Table 2. Correct gaskets/seals are fitted and are compatible with the media and process. The product is protected from fire. The product is protected from impact. This product is not used as a support for other equipment or personnel. Regular inspection for corrosion and wear are carried out, both internal and external. This product is adequately supported. 1

Reference Manual Materials Table 1. Chamber Pressure Materials Component Carbon steel Low temperature carbon steel Stainless steel Instrument Mounting Flange ASTM A105 ASTM A350 LF2 ASTM A182 F316/F316L Chamber Body Tube ASTM A106 Grade B ASTM A333 Grade 6 ASTM A312 TP316/TP316L Chamber End Cap ASTM A105 ASTM A350 LF2 ASTM A182 F316/F316L Process Flange / Fitting ASTM A105 ASTM A350 LF2 ASTM A182 F316/F316L T-Pieces and Reducers ASTM A234 WPB ASTM A420 WPL6 ASTM A403 WP316/WP316L S Standard Alloy Steel Studbolts ASTM A193 B7 ASTM A320 L7 ASTM A320 L7 Standard Alloy Steel Nuts ASTM A194 2H ASTM A194 Grade 7 + S3 ASTM A194 Grade 7 + S3 Stainless Studbolts ASTM A193 B8M Cl2 ASTM A193 B8 Cl 2 ASTM A193 B8M Cl2 Stainless Nuts ASTM A194 Grade 8M ASTM A194 Grade 8 ASTM A194 Grade 8M Bolting and tightening torque Table 2. Bolt Torques (Instrument Mounting Flange) Bolt torque (in Nm) (1) Flange rating Bolt size Fibre gasket Ring type joint (2) Spiral wound Flanges Class 150 (3 in.) Class 150 (4 in.) Class 300 (3 in.) Class 300 (4 in.) 5 /8-in. UNC 135 124 122 5 /8-in. UNC 135 112 122 3 /4-in. UNC 235 174 203 3 /4-in. UNC 235 196 203 Class 600 (3 in.) 3 /4-in. UNC (3) 218 203 Class 600 (4 in.) Class 900 (3 in.) 7 /8-in. UNC (3) 313 325 7 /8-in. UNC (3) 348 325 Class 900 (4 in.) 1 1 /8-in. UNC (3) 677 722 Class 1500 (3 in.) 1 1 /8-in. UNC (3) 752 722 Class 1500 (4 in.) 1 1 /4-in. UNC (3) 1040 1016 EN 1092-1 Flanges PN16 DN80 M16 125 120 PN16 DN100 M16 125 120 PN25 DN80 M16 125 120 PN25 DN100 M20 250 235 PN40 DN80 M16 125 120 PN40 DN100 M20 250 235 PN63 DN80) PN63 DN100 PN100 DN80 PN100 DN100 PN160 DN80 PN160 DN100 PN250 DN80 PN250 DN100 M20 M24 M24 M27 M24 M27 M27 M30 (3) 235 (3) 404 (3) Not Applicable 404 (3) 587 (3) 404 (3) 587 (3) 587 (3) 830 1.Tightening torques listed above are suitable for and EN 1092-1 standard instrument flanges when assembled with the alloy steel B7 and L7 bolting, stainless steel B8 class 2 bolting, and gaskets, that are supplied with the 9901 chamber and are for lubricated studs and nuts. 2.The torque values are applicable to both soft iron and stainless steel rings. 3. Fibre gaskets are not normally recommended for flange ratings CL600 / PN63 and higher, unless permitted by the instrument supplier. Refer to the manual supplied with the measuring instrument. 2

Reference Manual Important! Always refer to the manual supplied with the instrument. If that manual contains recommended tightening torques for the bolting and gaskets supplied with the 9901 chamber, use those values and not Table 2. For any other bolting or gasket, contact the instrument supplier for recommended tightening torques. Nameplate stamping explanation Table 3. Nameplate Stamping Explanation (imperial) Ps max @ 68 F Ts min 284 14 Ps max @ Ts max Ts max 94 752 Pt 435 Table 4. Nameplate Stamping Explanation (metric) Ps max @ 20 C Ts min 19.6 10 Ps max @ Ts max Ts max 6.5 400 Pt 30 Note Ts min for carbon steel with B16.5 flange (except Class 1500) is always: -20 F (minus 20 degrees Fahrenheit)/ - 29 C (minus 29 degrees Celsius) Ts min for carbon steel with EN 1092 flange or B16.5 flange (Class 1500) is always: 14 F (14 degrees Fahrenheit/ - 10 C (minus 10 degrees Celsius) Ts min for low temperature carbon steel is always: -50 F (minus 50degrees Fahrenheit)/ - 46 C (minus 46 degrees Celsius) Ts min for 316/316L stainless steel chambers is always: 148 F (minus 148 degrees Farenheit) / 100 C (minus 100 degrees Celsius) Ts max for carbon and stainless steel chambers with standard alloy steel bolting is always: 752 F (752 degrees Farenheit) / 400 C (400 degrees Celsius) Ts max for carbon and stainless steel chambers with stainless steel bolting is always: 752 F (752 degrees Farenheit) / 400 C (400 degrees Celsius) 3

Reference Manual Table 5. Chamber Pressure and Temperature Ratings (Standard Alloy Steel Bolting and Stainless Steel 316 Bolting) Class 150 Class 300 Class 600 Class 900 Class 1500 EN 1092 PN16 EN 1092 PN25 EN 1092 PN40 EN 1092 PN63 EN 1092 PN100 EN 1092 PN160 EN 1092 PN250 Class / Rating Ps max (RT) (4) 1.Ts min is 14 F (-10 C) (EN1092 & B16.5 Class 1500); Ts min is -20 F (-29 C) (B16.5 except Class 1500). 2.Ts min is -50 F (-46 C). 3.Ts min is 148 F ( 100 C). 4.RT is Room Temperature of 68 F (20 C). Working pressure (psi and bar) for the 9901 chambers Carbon steel (1) low temperature carbon steel (2) Stainless steel (3) Psi Bar Psi Bar 285 19.6 275 19.0 Ps max (752 F) / (400 C) 95 6.5 95 6.5 Pt 428 30 413 29 Ps max (RT) 740 51.1 720 49.6 Ps max (752 F) / (400 C) 505 34.7 425 29.4 Pt 1110 78 1080 75 Ps max (RT) 1480 102.1 1440 99.3 Ps max (752 F) / (400 C) 1015 69.4 855 58.9 Pt 2220 154 2160 149 Ps max (RT) 2220 153.2 2160 148.9 Ps max (752 F) / (400 C) 1520 104.2 1280 88.3 Pt 3330 230 3240 224 Ps max (RT) 3705 255.3 3600 248.2 Ps max (752 F) / (400 C) 2535 173.6 2135 147.2 Pt 5558 383 5400 373 Ps max (RT) 232 16 227 15.7 Ps max (752 F) / (400 C) 137 9.5 134 9.3 Pt 348 24 348 24 Ps max (RT) 362 25 356 24.6 Ps max (752 F) / (400 C) 214 14.8 211 14.6 Pt 543 37.5 536 37 Ps max (RT) 580 40 569 39.3 Ps max (752 F) / (400 C) 345 23.8 339 23.4 Pt 870 60 855 59 Ps max (RT) 913 63 899 62 Ps max (752 F) / (400 C) 543 37.5 536 37 Pt 1377 95 1348 93 Ps max (RT) 1450 100 1427 98.4 Ps max (752 F) / (400 C) 862 59.5 851 58.7 Pt 2175 150 2146 148 Ps max (RT) 2320 160 2291 158 Ps max (752 F) / (400 C) 1380 95.2 1361 93.9 Pt 3480 240 3437 237 Ps max (RT) 3625 250 3567 246 Ps max (752 F) / (400 C) 2158 148.8 2132 147 Pt 5438 375 5351 369 Manufacturer Mobrey Limited, 158 Edinburgh Avenue, Slough, Berkshire, SL1 4UE, United Kingdom Product recycling/disposal Recycling of equipment and packaging should be taken into consideration. The product and packaging should be disposed of in accordance with local and national legislation. 4

Reference Manual Standard Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_sale. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype, are registered trademarks of Rosemount Inc. All other marks are the property of their respective owners. 2014 Rosemount, Inc. All rights reserved. Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 906 8889 www.rosemount.com Emerson Process Management GmbH & Co. Argelsrieder Feld 3 82234 Wessling Germany Tel 49 (8153) 9390 Fax 49 (8153) 939172 www.rosemount.com Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.EmersonProcess.com www.rosemount.com Beijing Rosemount Far East Instrument Co., Limited No. 6 North Street, Hepingli, Dong Cheng District Beijing 100013, China T (86) (10) 6428 2233 F (86) (10) 6422 8586 www.rosemount.com, 08/14