MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

Similar documents
ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

SITE SERVICES GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013

CONCRETE PIPE JOINTS, YOUR BEST CHOICE

Concrete Pipe Joints Your Best Choice

CONSTRUCTION SPECIFICATION FOR CONCRETE CROSSWALK INDEX TS SCOPE...3

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

June 2007

Standard Specifications for Road and Bridge Construction. Adopted January 1, 2012

SECTION PIPE & PIPE FITTINGS PART 1 GENERAL

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

CONSTRUCTION SPECIFICATION FOR SINGLE AND DOUBLE SURFACE TREATMENT

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

CITY OF GREATER SUDBURY SUPPLEMENTAL SPECIFICATIONS TO THE ONTARIO PROVINCIAL STANDARD SPECIFICATIONS

SECTION FACILITY SANITARY SEWERS

SECTION UTILITY MANHOLES AND STRUCTURES

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

SITE PLAN CERTIFICATION REQUIREMENTS Rev 2 May 25, 2017

LANDSCAPE RETAINING WALLS

Concrete Pressure Pipe

B. Subsurface data is available from the Owner. Contractor is urged to carefully analyze the site conditions.

Central Concrete Product Limited. Product Catalogue

COMBINED CONCRETE SIDEWALK AND RETAINING WALL. Comply with Division 1 - General Provisions and Covenants, as well as the following:

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 811 CONDUIT AND DRAINAGE STRUCTURES

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK

CONCRETE PIPE USE MANUAL

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Independent Consulting Engineers NV Zaegersgut Rd #13 tel +(599) Date: 25 januari 2008 Project: Troy Hill Saba Projectnr:

DESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM

Section 2 Supplemental Specification 2.11 High Tension Cable Barrier

BASED ON DFD MASTER SPECIFICATION DATED 2/24/2014

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin

901 - PIPE SEWERS COMPLETE IN PLACE

CONCRETE PIPE & BOX CULVERT INSTALLATION

TYPE "A" CATCH BASIN

HOLDING TANK PLANNING & INSTALLATION GUIDELINES

A-2000 PVC Pipe for Storm Sewers and Drainage

PRECAST CONCRETE ON-SITE WASTEWATER TANKS

INTERNAL PRESSURE AND BACKFILL LOAD RESISTANCE CHARACTERISTICS OF POPIT LIFT HOLE PLUGS

Standards for Soil Erosion and Sediment Control in New Jersey May 2012 STANDARD FOR SLOPE PROTECTION STRUCTURES. Definition

SECTION TRENCHING & BACKFILLING


Fabrication and Installation Table of Contents

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

C. Foundation stabilization for pipe and utility structures.

CONCRETE PIPES CONCRETE PIPES FACTORY. Since Concrete. Slabs (Cover) for Cable. Trench Jacking. Jacking Pipes. Non & Reinforced. without.

BILL OF QUANTITY ENGINEERING & MANAGEMENT CONSULTING CENTRE. "Beit Hanoun Emergency Water Supply Project"

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE

DIVISION 31 EARTHWORK 2006 Edition, Published January 1, 2006; Division Revision Date: January 31, 2012

SECTION GRADING AND SITE PREPARATION CITY OF LEE S SUMMIT, MISSOURI STANDARD SPECIFICATIONS

RETAINING WALL LEVEL BACKFILL

SECTION 3 DRAINAGE. 3-1 General. 3-2 Drainage Ordinances and Legal Requirements

Historical Overview of the RCP Industry

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

SUGGESTED MANHOLE FRAME SEALING SPECIFICATION (Rehabilitation)

VERTI-BLOCK - DESIGN MANUAL

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

Design Data 4. Jacking Concrete Pipe

SANITARY GRAVITY SEWER LINES. A. Sanitary sewer lines, manholes, fittings, accessories, and bedding

Life Cycle Impact Results (per m3)

Method of Measurement for Road Works Series MM Earthworks

IN THE FIELD PIPE INSTALLATION INSTRUCTIONS

Town of New Tecumseth Engineering Design Criteria and Standards for Subdivisions and Capital Works Projects

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

GENERAL CONSTRUCTION

MODULAR CONCRETE RETAINING WALL

City of Peterborough Unit Price Contract Supplemental Information Package

Connecting the DOTs: ROADWAY USE OF RECYCLED MATERIALS

MOA Project # Golden View Drive Intersection & Safety Upgrades

CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS

AUGUST 2017 HASTINGS. retaining walls installation guide

Uwall UNIVERSAL CONSTRUCTION MANUAL

Estimate FOR THE SEPTIC TANK

THE ADVANTAGES HDPE MANHOLES

City of Peterborough Unit Price Contract Supplemental Information Package

Corrugated Metal Pipe Design Guide

Durability Performance of Australian Commercial Concrete Modified with Permeability Reducing Admixture

16. Design of Pipeline Structures.

Construction Documentation Track B LAP Advanced Thursday, September 25,2013 3:00 PM- 4:30 PM

PART A : CPVC PIPES AND FITTNGS (EXTERNAL WATERSUPPLY):


September 1, 2003 CONCRETE MANUAL SPECIAL TYPES OF CONCRETE

Rural Servicing Guidelines

No Admixture, Sustainable, Self-Consolidating Grout

CHECKLIST FOR STREETS, INLETS, AND STORM SEWER DESIGN

MICHIGAN DESIGN MANUAL ROAD DESIGN CHAPTER 4 INDEX DRAINAGE

3 rd PARTY MATERIALS TESTING MANUAL

DIVISION 33 - UTILITIES SECTION UTILITY PIPE BORING AND JACKING DIVISION 33 UTILITIES SECTION UTILITY PIPE BORING AND JACKING

Design Data 9. Standard Installations and Bedding Factors for the Indirect Design Method

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe

h Installation Manual

SDR26 material is to be used as a minimum on all U-M projects.

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

Concrete pipe reference manual Issue 1

Life Cycle Impact Results (per m3)

Transcription:

ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 1820 NOVEMBER 2017 MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE TABLE OF CONTENTS 1820.01 SCOPE 1820.02 REFERENCES 1820.03 DEFINITIONS - Not Used 1820.04 DESIGN AND SUBMISSION REQUIREMENTS 1820.05 MATERIALS 1820.06 EQUIPMENT - Not Used 1820.07 PRODUCTION 1820.08 QUALITY ASSURANCE - Not Used 1820.09 OWNER PURCHASE OF MATERIAL APPENDICES 1820-A Commentary 1820.01 SCOPE This specification covers the requirements for reinforced and non-reinforced non-pressure circular concrete pipe with rubber gasket joints, and for non-gasketed reinforced elliptical concrete pipe. 1820.01.01 Specification Significance and Use This specification is written as a municipal-oriented specification. Municipal-oriented specifications are developed to reflect the administration, testing, and payment policies, procedures, and practices of many municipalities in Ontario. Use of this specification or any other specification shall be according to the Contract Documents. November 2017 Page 1 of 6 OPSS.MUNI 1820

1820.01.02 Appendices Significance and Use Appendices are not for use in provincial contracts as they are developed for municipal use, and then, only when invoked by the Owner. Appendices are developed for the Owner s use only. Inclusion of an appendix as part of the Contract Documents is solely at the discretion of the Owner. Appendices are not a mandatory part of this specification and only become part of the Contract Documents as the Owner invokes them. Invoking a particular appendix does not obligate an Owner to use all available appendices. Only invoked appendices form part of the Contract Documents. The decision to use any appendix is determined by an Owner after considering their contract requirements and their administrative, payment, and testing procedures, policies, and practices. Depending on these considerations, an Owner may not wish to invoke some or any of the available appendices. 1820.02 REFERENCES When the Contract Documents indicate that municipal-oriented specifications are to be used and there is a municipal-oriented specification of the same number as those listed below, references within this specification to an OPSS shall be deemed to mean OPSS.MUNI, unless use of a provincial-oriented specification is specified in the Contract Documents. When there is not a corresponding municipaloriented specification, the references below shall be considered to be the OPSS listed, unless use of a provincial-oriented specification is specified in the Contract Documents. This specification refers to the following standards, specifications, or publications: CSA Standards A257.1-14 Non-Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe, and Fittings [Part of A257 Series-09, Standards for Concrete Pipe and Manhole Sections] A257.2-14 Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe, and Fittings [Part of A257 Series-09, Standards for Concrete Pipe and Manhole Sections] A257.3-14 Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections, and Fittings Using Rubber Gaskets [Part of A257 Series-09, Standards for Concrete Pipe and Manhole Sections] A3000-13 Cementitious Materials Compendium ASTM International C 507M-16 Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric) Plant Prequalification Program Publication Prequalification Requirements for Precast Concrete Drainage Products November 2017 Page 2 of 6 OPSS.MUNI 1820

1820.04 DESIGN AND SUBMISSION REQUIREMENTS 1820.04.01 Design Requirements 1820.04.01.01 Concrete Pipe Non-reinforced circular concrete pipe shall be according to CAN/CSA A257.1. Reinforced circular concrete pipe shall be according to CAN/CSA A257.2. Reinforced elliptical concrete pipe shall be according to ASTM C 507M. 1820.04.01.02 Joints and Gaskets Joints and gaskets for circular concrete pipe shall be according to CAN/CSA A257.3. Joints for elliptical concrete pipe shall be according to ASTM C 507M, and according to the requirements outlined in the publication, Prequalification Requirements for Precast Concrete Drainage Products. Elliptical concrete pipe produced with non-gasketed joints shall be used for storm pipe sewers only. 1820.04.01.03 Jacking Pipe Jacking pipe shall be according to CAN/CSA A257.2 with a minimum class of 65-D and a minimum concrete strength of 40MPa. 1820.04.01.04 Elliptical Reinforcing Elliptical reinforcing for circular concrete pipe is not permitted for pipes up to and including 900 mm nominal internal diameter. 1820.04.01.05 Lift Holes and Anchors Lift holes are not permitted for pipes. Lift anchors are not permitted for pipes up to and including 900 mm nominal internal diameter. 1820.05 MATERIALS 1820.05.01 Cement Cement shall be Portland cement or a commercial blend of Portland cement and blast-furnace slag or fly ash, or both. Ground granulated blast-furnace slag or fly ash may also be added separately to Portland cement. Whether added separately or in the form of blended cement, ground granulated blast-furnace slag shall constitute not more than 70% by mass of the total cementing materials and fly ash shall constitute not more than 40% by mass of the total cementing materials. Portland cement, blended cement, ground granulated blast-furnace slag, and fly ash shall be according to CAN/CSA A3000. November 2017 Page 3 of 6 OPSS.MUNI 1820

1820.07 PRODUCTION 1820.07.01 General A manufacturer producing circular concrete pipe or elliptical concrete pipe or both shall possess a current Prequalification Certificate, issued under the Plant Prequalification Program as outlined in the publication, Prequalification Requirements for Precast Concrete Drainage Products. 1820.07.02 Markings Markings for circular concrete pipe shall be according to CAN/CSA A257.2. Markings for elliptical concrete pipe shall be according to ASTM C 507M. In addition, all pipe shall be marked with the Prequalification Stamp shown in Figure 1 and as outlined in the publication, Prequalification Requirements for Precast Concrete Drainage Products. 1820.09 OWNER PURCHASE OF MATERIAL 1820.09.01 Measurement and Payment Circular concrete pipe and elliptical concrete pipe shall be measured in metres along the length of the pipe. Payment at the price specified in the purchasing order shall be for the supply of the circular concrete pipe and elliptical concrete pipe including gaskets, delivered to the destination on the date and time specified. The cost of all testing, except that performed in the Owner's laboratory, shall be included in the price. November 2017 Page 4 of 6 OPSS.MUNI 1820

Figure 1 Prequalification Stamp November 2017 Page 5 of 6 OPSS.MUNI 1820

Appendix 1820-A, November 2014 FOR USE WHILE DESIGNING MUNICIPAL CONTRACTS Note: This is a non-mandatory Commentary Appendix intended to provide information to a designer, during the design stage of a contract, on the use of the OPS specification in a municipal contract. This appendix does not form part of the standard specification. Actions and considerations discussed in this appendix are for information purposes only and do not supersede an Owner s design decisions and methodology. Designer Action/Considerations The designer should ensure that the General Conditions of Contract and the 100 Series General Specifications are included in the Contract Documents. Related Ontario Provincial Standard Drawings OPSD 802.030 Rigid Pipe Bedding, Cover, and Backfill, Type 1 or 2 Soil - Earth Excavation OPSD 802.031 Rigid Pipe Bedding, Cover, and Backfill, Type 3 Soil - Earth Excavation OPSD 802.032 Rigid Pipe Bedding, Cover, and Backfill, Type 4 Soil - Earth Excavation OPSD 802.033 Rigid Pipe Bedding, Cover, and Backfill, Rock Excavation OPSD 802.034 Rigid Pipe Bedding and Cover in Embankment, Original Ground: Earth or Rock OPSD 802.050 Horizontal Elliptical Rigid Pipe Bedding, Cover, and Backfill Type 1 or 2 Soil - Earth Excavation OPSD 802.051 Horizontal Elliptical Rigid Pipe Bedding, Cover, and Backfill Type 3 Soil - Earth Excavation OSPD 802.052 Horizontal Elliptical Rigid Pipe Bedding, Cover, and Backfill Type 4 Soil - Earth Excavation OPSD 802.053 Horizontal Elliptical Rigid Pipe Bedding, Cover, and Backfill Rock Excavation OPSD 802.054 Horizontal Elliptical Rigid Pipe Bedding and Cover in Embankment Original Ground: Earth or Rock OPSD 807.010 Height of Fill Table, Reinforced Concrete Pipe - Confined Trench, Class 50-D, 65-D, 100-D, and 140-D OPSD 807.030 Height of Fill Table, Reinforced Concrete Pipe - Embankment, Class 50-D, 65-D, 100-D, and 140-D OPSD 807.040 Height of Fill Table, Non-Reinforced Concrete Pipe, Class 3 OPSD 807.050 Height of Fill Table, Horizontal Elliptical Concrete Pipe, Class HE-A, HE-I, HE-II, HE-III, and HE-IV November 2017 Page 6 of 6 OPSS.MUNI 1820