A STRUVITE CONTROL AND PHOSPHORUS REMOVAL PROCESS FOR CENTRATE: FULL-SCALE TESTING. 850 Pembina Highway Winnipeg, MB

Similar documents
Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100

Preparing for Nutrient Removal at Your Treatment Plant

Pilot Testing Reveals Alternative Methods to Meet Wisconsin s Low Level Phosphorus Limits

EVALUATING ALTERNATIVES FOR DISPOSING OF WATER PLANT SOLIDS INTO A WASTEWATER PLANT

Third-Party Technology Verification of the Hydropath Technology at the Robert W. Hite Treatment Facility, Denver, Colorado

Struvia Technology for Phosphorus Recovery. o Re-Water Braunschweig November 2015

So You ve Removed Your Phosphorus? Now What? JTAC Luncheon April 9 th, 2014

AMMONIA REMOVAL FROM DIGESTED SLUDGE SUPERNATANT

East Coast P Removal Technology Performance Summary

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

CHEMICAL FREE PHOSPHOROUS ELIMINSTION P-UPTAKE PROCESS

Application of the AGF (Anoxic Gas Flotation) Process

ENHANCING BIOGAS PRODUCTION ON AN ANAEROBIC COGENERATION PLANT. Michael Romer. Calix Limited

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia.

4 Angles. Pilot-scale Evaluation of AirPrex for Phosphorus Management. Innovation Program Phosphorus Initiative JTAC 4/22/2017

USE OF CHEMICALS TO CONTROL ODORS AND CORROSION IN WASTEWATER SYSTEMS

Startup and Performance of the World s first Large Scale Primary Dissolved Air Floatation Clarifier ABSTRACT KEYWORDS INTRODUCTION

Review of WEFTEC 2016 Challenge & Overview of 2017 Event. Malcolm Fabiyi, PhD, MBA Spencer Snowling, PhD. P.Eng

Proposal by Russia to delete hot sub-spot Hot sub-spot name South-West Wastewater Treatment Plant

Worldwide Pollution Control Association

OPERATORS PERSPECTIVE : OPTIMISATION OF A NEW PACKAGE WATER TREATMENT PLANT. Melina Entwistle. North East Water Authority

Wastewater Treatment Processes

First Let s Define some Terms the most important terms used with these concepts are:

PANEL: Making a resource into the right source

CeraMem. Ceramic Membrane Technology. Advanced Heavy Metals Removal System WATER TECHNOLOGIES

UV DISINFECTION OF LOW TRANSMITTANCE PHARMACEUTICAL WASTEWATER

SLUDGE SETTLEABILITY CONTROL AT ELANORA WWTP RAS CHLORINATION TRIAL. Martin Hindmarsh. Allconnex Water

Process Monitoring for Biological and Chemical Nutrient Removal

WEFTEC.06. **Cobb County Water System, Marietta, Georgia

A NEW METHOD FOR EVALUATING PRIMARY CLARIFIERS Alex Ekster and Cristina Pena San Jose/Santa Clara Water Pollution Control Plant City of San Jose

TREATMENT of liquid wastes results in the production

Corrosion and Odor Control in Wastewater Systems

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

COMPARISON OF CHEMICAL AND BIOLOGICAL PHOSPHORUS REMOVAL IN WASTEWATER - A MODELLING APPROACH

Guide to Inclined Plate Settlers

Energy Optimized Resource Recovery Project Presented By: Curtis Czarnecki, P.E.

Optimization of Anaerobic Digestion with Bio- Organic Catalyst Compositions (BOCs)

Proposal by Russia to delete hot spot 18.2

Removing Heavy Metals from Wastewater

Choices to Address Filamentous Growth

An Introduction to Chemically Enhanced Primary Treatment

Livestock and poultry producers are seeking. Solid-Liquid Separation. of Animal Manure and Wastewater E

A H. Marcela Velázquez-Carrillo Consultant to Mountain Systems Inc. on the application of Proficy for Water Treatment

Advanced Wastewater Treatment Plant Plant Profile

PRODUCING STABILISED MAGNESIUM HYDROXIDE LIQUID CHEAPLY USING TREATED WASTEWATER AT YOUR STP. Brett McCasker. Wise Waste Solutions Pty Ltd.

Water Treatment Plant Startup Issues and Considerations

Engineering Report ENVIRONMENTAL ENGINEERS, SCIENTISTS AND PLANNERS

SUCCESSFUL DEWATERING OF ACID MINE DRAINAGE MATERIALS 1

Conceptual Design for a Future Wastewater Treatment Plant

Kenosha Wastewater Treatment Plant - Energy Optimized Resource Recovery Project

Sewage Sludge Treatment in Large Cities Using the Example of Berlin

The Conservation Fund Freshwater Institute, Shepherdstown, West Virginia 25443, USA PHILIP L. SIBRELL

Tampa Bay Water (TBW) is a regional

International Joint Commission Water & Wastewater Treatment Best Management Practices Forum Monday, March 26, 2012 Wayne State University, Detroit MI

Chemical Oxygen Demand Flow Rate Effect on Total COD and the Particulate/Soluble COD Ratio

Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes

Dr Martin Peter *, Joachim Scholz & Victor Ferre. Contents

ENHANCED MEMBRANE CLEANING WITH REDUCING AGENTS TO REMOVE IRON FOULING. Introduction

Lagoons Operation and Management in New Brunswick

ASA Analytics ChemScan Process Analyzers Reprint ASA Publication #194

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

Anaerobic Digester Optimization with Bio-Organic Catalyst. NYWEA 81 st Annual Meeting February 3, 2009 One Year Study November 07 - November 08

Technology Update Phosphorus Removal. Samuel Jeyanayagam, PhD, PE, BCEE Vice President/Senior Principal Technologist CH2M HILL

CENTRIFUGE DECANTER AND HOW IT WORKS

JTAC Presentation May 18, Nutrient Removal Process Fundamentals and Operation

Screw Press Dewatering Optimization. Kelly Brown, BDP Industries, Inc.

Phosphate recovery from wastewater with engineered superparamagnetic composite particles using magnetic separation

CEDAR CREEK Wastewater Treatment Facility

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

ARSENIC IN DRINKING WATER

WASTEWATER TREATMENT

Nutrient Removal Processes MARK GEHRING TECHNICAL SALES MGR., BIOLOGICAL TREATMENT

Significance of Design and Operational Variables in Chemical Phosphorus Removal

STREAMING CURRENT MONITOR FOR COAGULANT OPTIMIZATION IN WATER TREATMENT PLANTS - LAP EXPERIENCE

COMPARISON OF PROCESS ALTERNATIVES FOR ENHANCED NUTRIENT REMOVAL: PERSPECTIVES ON ENERGY REQUIREMENTS AND COSTS

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT

CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES DEPARTMENT WASTEWATER TREATMENT OPERATIONS GREENWAY POLLUTION CONTROL CENTRE 2013 ANNUAL REPORT

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2012

PAGEL S PONDEROSA DAIRY REPORT

Coagulation and Flocculation: Color Removal

EVALUATION OF A WATER TREATMENT PLANT PERFORMANCE CASE STUDY

A Case Study from EP3: Pollution Prevention Assessment from a Cattle Hide Tannery. HBI Pub. 10/31/94

BOC Hydrogen Sulfide Odor Control Reduction Program

Crystal Lake and Keller Lake Water Quality Evaluation and Ferric Chloride Treatment Project

Monitoring Industrial Wastewaters and their Effects on Wastewater Treatment Plants: Konya Example

DW de Haas #, MC Wentzel* and GA Ekama Department of Civil Engineering, University of Cape Town, Rondebosch 7700, South Africa.

FAYOUM CITY SEWAGE TREATMENT PLANT, DEVELOPMENT STAGES, CASE STUDY

Carbon Heat Energy Assessment and. (CHEApet) Tutorials: Carbon Footprint Primer

Utilizing Anaerobic Digester Capacity to Process Source Separated Organics: Two Case Studies

Unit Treatment Processes in Water and Wastewater Engineering

AMMONIA AND PHOSPHORUS REMOVAL IN WASTE WATER TREATMENT

Advanced Aerobic Digestion. ThermAer. Autothermal Thermophilic Aerobic Digestion. Biosolids Treatment. Thermal Process Systems ThermAer Process

Enhanced Nutrients Removal in Conventional Anaerobic Digestion Processes

BIOLOGICAL PHOSPHOROUS REMOVAL AN OPERATOR S GUIDE

Iron/Manganese Package Plant Pre-Engineered Ground Water Treatment. Village of Bolivar, NY

Use of Biowin for Process Troubleshooting / Design for a Unique Wastewater

REAL WORLD APPLICATIONS OF USING DYNAMIC SIMULATION SOFTWARE TO OPTIMIZE WATER TREATMENT PLANT PROCESS OPERATIONS

SECTION 14.0 BIOLOGICAL NUTRIENT REMOVAL

NEWPCC Upgrade Site Info Tour Spring 2017 April 19 th 1pm, April 24 th 1pm, April 27 th 9am

Transcription:

A STRUVITE CONTROL AND PHOSPHORUS REMOVAL PROCESS FOR CENTRATE: FULL-SCALE TESTING Simon Baker 1, Yoomin Lee 1, Wang Li 1 1 Earth Tech Canada Inc 850 Pembina Highway Winnipeg, MB ABSTRACT The North End Water Pollution Control Centre (NEWPCC) in Manitoba, Canada serves a population of approximately 380,000. The dry weather flow to the NEWPCC is approximately 175 ML/d (46 MGD). The plant uses anaerobic digestion and centrifuge dewatering in its solids treatment train. The centrate stream comprises approximately 20 percent of the plant s phosphorus load. The plant suffers from severe struvite (magnesium ammonium phosphate) deposition: centrifuges and centrate piping have to be regularly cleaned. The Province requires that the plant control the phosphorus load recycled in the centrate: the total phosphorus (TP) load must not exceed 119 kg/d, as determined by a thirty day rolling average. In order to meet the requirements of the Province, and to control struvite, a metal salt will be dosed into the digested sludge, upstream of the centrifuges. Prior to design of a metal salt dosing system, a full-scale trial was initiated. Two potential metal salts were identified; ferric chloride (FeCl 3 ) and aluminum sulphate or alum (Al 2 (SO 4 ) 3 14H 2 O). Examination of struvite crystals in the digested sludge indicated that nearly complete disappearance of crystals occurred at all dosing rates used in these trials. The trials demonstrated that alum and ferric chloride were highly effective in meeting the removal objectives and controlling struvite crystal formation in the centrate. KEYWORDS Struvite, centrate, aluminum sulphate, ferric chloride INTRODUCTION Manitoba Conservation issued a new licence in June, 2005 which provides the operating requirements of the NEWPCC in Winnipeg, Manitoba. The licence stipulates that the centrate from the sludge dewatering facility should have a TP load that does not exceed 119 kg/d, as determined by a thirty day rolling average. In order to meet the requirements of the licence, it is proposed that phosphorus be removed from the centrate stream and directed to the biosolids stream, by the dosing of a metal salt into the sludge. Two potential metal salts were identified; ferric chloride (FeCl 3 ) and aluminum sulphate or alum (Al 2 (SO 4 ) 3 14H 2 O). Struvite is magnesium ammonium phosphate (MAP) and has the chemical formula of MgNH4PO4 6H2O. Struvite is commonly found in wastewater treatment plants that have anaerobic digesters. Struvite forms when the chemical constituents reach levels of 5197

supersaturation. Struvite formation requires nucleation sites, and is particularly prevalent in areas of turbulence where CO 2 is released, causing an increase in ph. The City has experienced severe struvite formation in the dewatering facility, which has led to some operational difficulties. Struvite has been found to coat the centrifuges and the centrate piping. Since phosphate is a key constituent of struvite, removal of phosphate could reduce the potential for struvite precipitation. Therefore, the removal of phosphorus from the centrate stream, could reduce the quantity of struvite deposited in the piping and centrifuges. Due to the risk that struvite deposition in the centrate pipes could get worse with the implementation of BNR, phosphorus removal options for the centrate treatment project should consider the benefits of phosphorus removal in a manner that reduces unwanted struvite formation. In order to verify that a metal salt could remove phosphorus from the centrate, it was agreed that jar-tests would be undertaken on the liquid digested sludge. Preliminary jar-tests were undertaken using ferric chloride and alum prior to the full-scale trials. After addition of the chemical, each sample was centrifuged and filtered. Results were positive indicating that the phosphorus concentration in filtered sludge samples could be reduced by metal salt dosing. It was found that at an alum dose rate of approximately 130 mg/l (as Al), approximately 70 percent of the phosphate was removed. For ferric chloride, it was found that at a dosage of approximately 360 mg/l (as Fe), approximately 75 percent of the phosphate was removed. Although jar-tests are valuable in evaluating metal salt dosing rates they are often not directly comparable to the full-scale environment due to differing conditions (e.g. mixing intensity, reaction time and dewatering efficiency). This paper presents the results of the full-scale trials using ferric chloride and alum conducted in April and May of 2005 in order to estimate the optimal dose rates and to assess which metal salt is better suited for phosphorus removal at the NEWPCC. An additional goal was to investigate if struvite formation in the centrate could be controlled with the addition of these metal salts. EXPERIMENTAL SET-UP The full-scale trials involved the dosing of metal salts into the centrifuge feed piping. This arrangement allowed a dose-response relationship to be established relatively quickly. A solution containing 48.4 percent alum and 31.0 percent ferric chloride was used for the full-scale phosphorus removal trial. Figure 1 illustrates the dosing point for the trials. The chemicals were manufactured by Eaglebrook Inc. and supplied in 1,000 litre totes. The chemical in the tote was injected using a dosing pump skid and connecting hoses, both of which were supplied by Eaglebrook. The metal salts were injected into the discharge piping of the centrifuge sludge feed pump. To facilitate mixing of the metal salt with the sludge, an existing section of vertical steel piping was removed and replaced with a PVC in-line mixer with integral dosing point and a PVC spool piece. A miniberm secondary containment system was installed 5198

around the dosing pump skid and tote. Figure 2 illustrates the arrangement of the secondary containment system and the chemical tote. Digested Sludge Holding Tanks Ferric chloride or alum Centrifuge Centrate Dewatered biosolids cake Centrate to interceptor sewer Figure 1 - Schematic Diagram of Dosing Point In-line mixer Dosing pump skid Chemical tote Miniberm Figure 2 - Secondary Containment System and Chemical Tote 5199

TESTING PROTOCOLS Two experiments were performed. In the first experiment, alum was added to the digested sludge. In the second experiment, ferric chloride was added to the digested sludge. In each experiment, three trials were performed. Table 1 summaries the dosing rates of the metal salts utilized in the trials. Table 1 - Dosing Rates of Metal Salts Alum Concentration Trial 1 Trial 2 Trial 3 (mg/l as Al) April 25/05 May 2/05 May 6/05 Dose 1 (mg/l as Al) 57 22 37 Dose 2 (mg/l as Al) 81 40 61 Dose 3 ( mg/l as Al) 114 58 77 Dose 4 (mg/l as Al) 138 81 97 Dose 5 (mg/l as Al) 170 142 118 Ferric Concentration Trial 1 Trial 2 Trial 3 (mg/l as Fe) May 10/05 May 16/05 May 17/05 Dose 1 (mg/l as Fe) 118 127 127 Dose 2 (mg/l as Fe) 195 195 273 Dose 3 (mg/l as Fe) 293 273 390 Dose 4 (mg/l as Fe) 351 342 468 Dose 5 (mg/l as Fe) 410 439 585 Each dose rate was maintained for 30 minutes during which three sets of samples of centrate and biosolids cake were collected (at 0, 10, and 30 minutes). The collected samples were then analyzed by the City for the parameters listed in Table 2. Table 2 - Summary of Analyses Sample Sample Type Parameter Unit Grab Total suspended solids (TSS) concentration mg/l Centrate Grab Total phosphorus (TP) concentration mg/l Grab Crystal concentration No./mL Grab ph - RESULTS 5200

Alum Trials Figure 3 illustrates the results of the full-scale alum trials. It was found that as the alum dose rate increased the concentration of TP in the centrate stream decreased and tailed off at approximately 10 to 20 mg/ L TP. Figure 3 - Changes in TP Concentration in Centrate Stream Figure 4 - Percent Reduction in Crystal Concentration Figure 4 present the concentration of crystals in the centrate. The crystals were not analyzed, but it is assumed that the crystals are struvite. As noted in the figure, the impact of the addition of alum to the centrate stream on the crystal concentration was significant. For instance, a low dose 5201

of approximately 20 mg/l (as Al) was able to reduce the crystal concentration by 65 percent. At an alum dose of 60 mg/l (as Al) more than 90 percent of the crystals were removed. Figure 5 shows microscope photos of the centrate taken during Alum Trial 2. a) Alum dose rate at 0 mg/l (as Al) b) Alum dose rate at 22 mg/l (as Al) c) Alum dose rate at 142 mg/l (as Al) Figure 5 - Microscope Photos of Centrate Crystals in Alum Trial The changes in TSS concentration in the centrate stream are summarized in Figure 6. As expected, the TSS concentration was reduced with the addition of alum due to its coagulant effect and the reduction in crystal concentration of the centrate. At a dose rate of approximately 60 mg/l (as Al), the concentration of TSS started to tail-off. The ph changes in the centrate stream are summarized in Figure 7. Struvite is least soluble at a ph of approximately 10. If the ph is above or below 10, the solubility of struvite increases. In the ph range shown in the figure, struvite solubility would be expected to increase as the dose rate of alum increased. Since there is a reduction in phosphorus content of the centrate and there is an increase in phosphorus content of the biosolids, the reduction in ph is likely not the cause of the reduction in the concentration of crystals; rather the reduction in crystals is due to the formation of aluminum phosphate which is removed with the biosolids cake. 5202

Figure 6 - Changes in TSS Concentration in Centrate Figure 7 - Changes in ph in Centrate Ferric Chloride (FeCl 3 ) Trials Figure 8 illustrates the results of the full-scale trials for ferric chloride. The results of Ferric Trial 1 showed that as the ferric chloride dose rate increased the concentration of TP in the centrate stream decreased. Of note, the second and third ferric chloride trials had centrate phosphorus concentrations initially reported as <0.05 mg/l at the high dose rates. These low concentrations were likely inaccurate due to the high dilution factors involved in the analytical procedure and the low concentrations of phosphorus in the samples. The samples were re-analyzed using a more appropriate dilution factor. The revised results were confounding in that the centrate phosphorus concentration increased after the dose of 273 mg/l. 5203

Figure 8 - Changes in TP Concentration in Centrate Figure 9 presents the number of crystals (assumed to be struvite) in the centrate with the addition of ferric chloride. The addition of ferric chloride had a marked effect on the crystal concentration. For instance, more than 90 percent of the crystals were removed at a concentration of approximately 110 mg/l (as Fe). Figure 9 - Percent Reduction in Crystal Concentration 5204

The changes in TSS concentration and ph in the centrate stream are summarized in Figures 10 and 11, respectively. As expected, the TSS concentration was reduced with the addition of ferric due to its coagulant effect and the reduction in concentration of crystals in the centrate. At a dose rate of approximately 100 mg/l (as Fe), the concentration of TSS started to tail off. Figure 10 - Changes in TSS Concentration in Centrate Figure 11 - Changes in ph in Centrate As illustrated in Figure 11, the ph change in the centrate stream reduces as the concentration of ferric increases. However, as explained for the alum trials, it appears that the reduction in ph is not the cause for the reduction in concentration of crystals in the centrate. 5205

Figure 12 illustrates the Fe content in the biosolids cake. As the concentration of ferric chloride dose increased, the concentration of Fe in the biosolids cake increased in response to the addition of ferric chloride. For instance, in Ferric Chloride Trial 2, the initial Fe content was approximately 13,350 mg P/kg sludge, or 1.34 percent. When the ferric chloride dose reached 450 mg Fe/L, the Fe content increased to 30, 840 mg Fe/ kg sludge, or to 3.08 percent. Figure 12 - Changes in Fe Concentration in the Biosolids Cake Complete phosphorus mass balances were performed on the experimental data during the alum and ferric chloride full-scale trials. The results of the mass balance calculations are presented in Table 3. The overall phosphorus balance closed to 105 percent, indicating data integrity. Table 3 - Phosphorus Mass Balances INPUT OUTPUT Balance Feed Sludge TP Biosolids Cake Centrate TP Total TP % (kg/d) TP (kg/d) (kg/d) (kg/d) Alum Trial 1 277 301 21 317 116 Alum Trial 2 285 276 26 303 106 Alum Trial 3 306 279 32 313 102 Ferric Trial 1 278 250 27 279 91 Ferric Trial 2 313 299 19 319 104 Ferric Trial 3 349 319 18 337 110 Average 105 5206

DISCUSSION Based on the results obtained from the trial, it was found that the optimum dose rates for alum (as Al) and ferric chloride (as Fe), to meet the terms of the Licence, were 118 mg/l and 336 mg/l, respectively. Cost comparisons between alum and ferric chloride were made based on the dose rates. It was determined that the application of alum would be slightly cheaper than that of ferric chloride. Ferric phosphate salts are more inert and less bio-available than aluminum phosphate salts. Therefore due to the better land application properties of the iron phosphate rich biosolids, ferric chloride was selected. The optimum ferric chloride dose rate of 336 mg/l (as Fe) corresponds with a dose of 16.8 kg Fe/tonne dry solids. This dose rate was compared with other studies. For instance, work at the Southeast WPCP in San Francisco (Mamais et al., 1997) indicated that for struvite prevention, a Fe:P ratio of 2.7 was required when ferric chloride was added to lab-scale digesters. This ratio is somewhat lower than the value estimated for the NEWPCC, although the dosing location at the NEWPCC is after digestion rather than into the digesters as undertaken in the Southeast study. For complete struvite removal a ferric dose of 756 mg/l Fe (13.5 mm/l FeCl 3 ) was estimated for the Southeast facility. In practice, ferric chloride was dosed immediately upstream of the centrifuges at a dose of approximately 400 mg/l Fe (7.2 mm/l FeCl 3 ) for struvite control, rather than complete struvite prevention. This dose rate to the centrifuge feed corresponds to a dose of 17.0 kg Fe/tonne dry solids, which compares favourably with the estimated value of 16.8 kg Fe/tonne dry solids for the NEWPCC. At the Jainsville Wastewater Treatment Plant (WWTP), in Wisconsin, ferric chloride is added to the digested sludge immediately upstream of the centrifuges. The Jainsville plant has biological phosphorus removal and therefore has a digested sludge stream that is rich in phosphorus. Ferric chloride is dosed at a rate of approximately 430 mg/l Fe into the sludge. This ferric dose rate corresponds with a dose of 17.1 kg Fe/tonne dry solids, which compares well with the value estimated for the NEWPCC. CONCLUSIONS Conclusions from the trials are as follows: The dosing of alum and ferric into the digested sludge reduced the concentration of crystals in the centrate sample. The crystals are assumed to be struvite. It must be noted that the trials did not test whether the reduction in crystal concentration affected struvite deposition on piping and equipment. However, experience elsewhere indicates that ferric chloride is successfully dosed upstream of centrifuges for struvite control. The dosing of alum or ferric into the digested sludge resulted in a reduction in the phosphorus concentration of the centrate. Dose-response relationships were obtained which allowed an estimate of the future ferric and alum doses. To achieve the required reduction in TP load in the centrate, the estimated average future dose rates are 118 mg/l Al and 336 mg/l Fe. 5207

REFERENCES Mamais, P.P., Y. Cheng, J. Loiacono and D. Jenkins (1994) Determination of ferric chloride dose to control struvite precipitation in anaerobic sludge digesters. Water Environ. Res, 66(7), 912-918. 5208