SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

Similar documents
SJI Code of Standard Practice

CODE OF STANDARD PRACTICE

North Mountain IMS Medical Office Building

Structural Redesign Gravity System

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Structural Technical Report #2 By Robert Whitaker

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

STANDARD SPECIFICATIONS

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

SECTION PLATE CONNECTED WOOD TRUSSES

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

Project Address: Name of Person Completing Form:

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

THE SJI COMPOSITE STEEL JOIST CATALOG FIRST EDITION 2007 FOR USE BY THE DESIGN PROFESSIONAL

Tech Tips SidePlate Connections FAQ 09/30/2017

A division of Canam Group

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Smarter. Safer. Leaner.

CH. 9 WOOD CONSTRUCTION

Copyright. magazine. CFS Load Bearing Construction

LIFE SCIENCES BUILDING STRUCTURAL CONCEPTS AND EXISTING CONDITIONS

Totaling approximately 617,000

AISC Steel & Timber Research for High-Rise Residential Buildings

xiii Preface to the Fifth Edition Preface to the Second Edition Factors for Conversion to SI Units of

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

EXPERIMENTAL STUDY OF OPEN WEB STEEL JOISTS WITH CRIMPED CRITICAL WEB MEMBERS E.T.Buckley 1, D.W.Dinehart 2, P.S.Green 3, S.P.Gross 2, J.R.

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

SAFE HANDLING AND ERECTION OF STEEL JOISTS AND JOIST GIRDERS

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES

DESIGN CRITERIA. Allowable Stress Design (ASD) AISC-1999.

AIA St. Louis January 4 th, 2017 Phillip Shinn, PE Jacobs Engineering Washington University in St. Louis, Sam Fox School of Design and Visual Arts

The Ultimate Structural Engineering Software Package!

The Perfect Choice for Mezzanines in Custom Metal Buildings

FDA CDRH Laboratory Silver Spring, Maryland. Executive Summary: Timothy Mueller Structural Option Walter Schneider

Including RedForm LVL, RedForm-I65, I90 and I90H Joists. Lightweight for Fast Installation. Compatible with Standard Framing

16. Design of Pipeline Structures.

Structural Option April 7 th, 2010

one structural behavior, systems and design Course Description Course Description Syllabus & Student Understandings statics mechanics of materials

2016 Port of San Francisco Building Code

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

PREFABRICATED STEEL TRUSS SPECIFICATIONS

Executive Summary Thesis Proposal

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Kiski Area High School Allegheny Township, PA FLOOR SYSTEM ANALYSIS

Prospective Construction Systems for Mass Housing

DESIGN CALCULATIONS INSTA-FOOTING LOAD BEARING CAPACITIES ON CONCRETE SLAB. January 14, 2017 Rev -

ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK.

Corporate Headquarters

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

Steel Frame Structure

BEARING METAL STUD FRAMING

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Bjorhovde, R. Stub Girder Floor Systems Structural Engineering Handbook Ed. Chen Wai-Fah Boca Raton: CRC Press LLC, 1999

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

CVEN 483. Structural System Overview

A Composite Structural Steel and Prestressed Concrete Beam for Building Floor Systems

The designer shall also submit additional information required by the University as described and underlined below.

Types Of Roofs - Vault

Minimum Guidelines for the Design and Use of Underpins When Performing Foundation Stabilization and/or Supplementation UP-08

There are countless ways to improve constructability on your next project. Here are 50 of them. the need for it or specify it on the design drawings.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

Vibration Characteristics and Acceptability of Cold-formed Steel Joists

Tables with Allowable ASD Seismic Values For Design at R = 6.5. Special Moment Frame MF1-12

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Product Designation As specified in the AISI standard for cold formed steel framing General provisions A5.2.

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC.

Eric Alwine Structural Option George Read Hall The University of Delaware Dr. Boothby Technical Assignment #2 October 31, 2005 EXECUTIVE SUMMARY:

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

LAMINATED VENEER LUMBER

W. Mark McGinley March 3, 2016 ISEA MEETINGS 1

Global Village Rochester Institute of Technology Rochester, New York

Residential Wood Deck Design

Dead Load Weight of Roof Trusses. Dead Load Weight of Floor Trusses

Composite Beam Design Manual AISC

Nabil A. Rahman, Ph.D., P.E.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

Structural Design of Dam Sluice Gate Walkway Slabs: Retrofit and Replacement Options

Castellated and Cellular Beams Open approach to building design for improved cost and performance. 1 of 58

Floor Vibration: Causes and Control Methods. Overview Revised 2/2/2017

APPENDIX. WOOD JOIST/RAFTER MAXIMUM SPANS ( for 16 o.c. spacing) WITH SINGLE ROW OF PV PANELS AT MIDSPAN (ft.) AND PANEL SUPPORT AT 32 o.c.

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

2.2E Parallam PSL Deep Beam

LVL Product Guide 2.0E LVL 1.5E LVL

TABLE OF CONTENTS 4.5.1

Individual Truss Marking Is it a Building Code Requirement?

Design No. D925 December 10, Restrained Assembly Ratings 3/4, 1, 1-1/2, 2 or 3 Hr. (See Items 1, 6 and 10)

CIVIL BREADTH Exam Specifications

Concrete Framing systems. Design choices. Basic flavors

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

Design of Short Span Steel Bridges

Design Example 2 Reinforced Concrete Wall with Coupling Beams

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

ANALYSIS AND DESIGN OF MOMENT RESISTING MIDWALL BY THE STEEL NETWORK, INC.

North Mountain IMS Medical Office Building

Comparative Study of R.C.C and Steel Concrete Composite Structures

Transcription:

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series SUMMARY David Samuelson Steel joists are growing in recognition as being a very economical system for supporting building floors. This paper discusses the expanded load carrying capabilities of noncomposite steel joists and joist girders beyond the Steel Joist Institute s current K, LH, DLH, and Joist Girder load tables. An update is given on the work completed by the Steel Joist Institute s Composite Joist Committee which currently is preparing a Standard Specification, Recommended Code of Standard Practice, and Load Tables for composite steel joists. David Samuelson is a structural research engineer employed by Nucor Corporation in the Research and Development Department. Mr. Samuelson received a Bachelor of Science Degree in Civil Engineering from the University of Nebraska, Lincoln in 1974 and a Masters of Science degree in Civil and Environmental Engineering in 1981 from the University of Colorado, Boulder. Mr. Samuelson is a registered professional engineer in the state of Colorado. Mr. Samuelson joined Nucor Corporation in 1982 and has been employed in the Nucor Research and Development Department since that time. During the last 12 years Mr. Samuelson has been heavily involved with the coordination of research testing projects evaluating the performance of composite shortspan joists, composite longspan joists, and composite joist girders. Mr. Samuelson was involved with the development of design guidelines and load tables for Vulcraft s new VC Series composite joists. Mr. Samuelson is a member of the American Institute of Steel Construction TC5 Committee on Composite Construction and Chairman of the Steel Joist Institute s Composite Joist Committee.

SJI Updates Expanded Load Tables for Noncomposite Joists/ Joist Girders INTRODUCTION and Development of New Composite Joist Series David Samuelson Steel joists are widely utilized not only in roofs but also floor systems. The Steel Joist Institute in the near future will be publishing extended weight tables for LH Series joists and Joist Girders covering increased loads, spans, and larger chord angle sizes. An update is given on the work currently being undertaken by the Steel Joist Institute s Composite Joist Committee. Currently this committee is preparing a Standard Specification, Code of Practice, and Load Tables for SJI s new composite joist series. EXPANDED JOIST LOAD TABLES The Steel Joist Institute is looking to develop a new joist weight table providing information beyond the current K, LH, and DLH joist series. The Steel Joist Institute s (SJI) steel joist load tables were originally derived utilizing typical joist spacings and roof loadings. The first joist load table adopted by SJI on August 20, 1929 was for the SJ Series with joist depths varying from 8 16 inches and spans from 4 32 feet. Standard chords sizes were assigned a numerical value from 1 to 7. For a given joist depth, chord size, resisting moment, and maximum end reaction, the allowable uniform load was determined for spans from 4 32 feet. Maximum uniform load carrying capacities varied from 77 800 pounds per lineal foot. In 1953 SJI adopted the Longspan steel joist load tables which were formatted very similar to the current SJI Longspan LH Series steel joists. Joist depths varied from 18 48 inches and spans from 25 96 feet. For standard chord sizes varying from 02 19, uniform load capacities were shown from 154-821 pounds per lineal foot. The current SJI LH-Series Load Tables adopted on May 25, 1983 and revised May 1, 2000 have joist depths varying from 18 48 inches and spans from 25 96 feet. Standard chords vary from 02 17 with uniform load carrying capacities from 174 1068 pounds per lineal foot. K Series joists adopted by the SJI on November 4, 1985 vary in depth from 8 to 30 inches with spans from 8 to 60 feet. In the case of K Series joists, the maximum uniform load is limited to 550 pounds per lineal foot. With typical total floor loadings of 100 150 pounds per square foot, the maximum K Series joist spacings are approximately 4 feet. When steel joists were first utilized in floor systems they were typically spaced two feet on centers. A layer of wire mesh backed paper was stretched over the joists and fastened with clips to the joist top chords. Sufficient joist bridging needed to be furnished to support the wet weight of the concrete as the wire meshed paper fabric acted only as a vertical form for the concrete. In the 1960 s 0.6C steel deck was introduced replacing wire mesh backed paper systems. The 0.6 C deck was designed so that the joists could typically also be spaced at 2 foot centers. The 0.6C metal deck provided lateral support for the joists once the deck was fastened to the joists and also provided a walking surface prior to placement of the concrete slab. As the usage of metal deck expanded within the United States, deeper 1, 1.5, 2, and 3 inch steel deck profiles have become very common. Current steel deck profiles can readily accommodate joist spacings from 4 15 feet, the net result being an increase in floor loading per joist.

For example a 2 inch deep metal deck supporting a 3.5 inch normal weight concrete topping has a combined deck and slab dead load of 57 pounds / square foot. With an assumed live load of 100 psf, 24 inch deep steel joists clear spanning 40 feet with joists spaced at 10 feet centers, each joist would support the following loading: 5.5 inch deep normal wt concrete supported by 2 inch high deck: 57 psf x 10 feet = 570 plf Estimated weight of joist & bridging: 53 plf Mechanical, electrical, floor, and ceiling: 10 psf x 10 feet = 100 plf Live Loading: 100 psf x 10 feet= 1,000 plf Total Loading 1,723 plf Looking in the SJI LH Series load table for a 40 foot clear span and 24 inch deep joist, the largest joist shown is a 24LH11. The 24LH11 joist supports 768 pounds per lineal foot with the allowable uniform live load that produces an L/360 deflection being 418 pounds per lineal foot. As can be seen the load carrying capacity of the 24LH11 (768 plf) is less than half that required (1, 723 plf). Likewise the 24LH11 would have an anticipated live load deflection of L / 150 which generally would be unacceptable. In the above illustration one would have to specify a Special joist design as the required load per lineal foot exceeds the loads listed in the SJI tables. One could specify this joist by indicating the following on the floor plans 24LH SP 1723 / 1000. To provide Engineers a way to determine joist weight and anticipated deflections for joists with uniform loadings greater than shown in the SJI K, LH, and DLH joist series load tables, new joist weight and deflection tables will be prepared. It is anticipated that the new extended LH Series joist table will indicate joist weight and uniform live load that will result in a L/360 deflection. The range of parameters may extend as far as are shown below: Spans: Joist Depth: Uniform Loads: Maximum chord angle size: Bearing depths: 10 feet 200 feet 8 inches 120 inches 200-3000 lbs / foot 6 inches x 6 inches x 0.750 inches 2.5 inches, 5 inches, or 7.5 inches ADVANTAGES FOR WIDER JOIST SPACINGS Placing joists at wider spacings as shown in Figure 1 can potentially have a number of advantages including the following: Wider joist spacings reduce the number of joist lifts during construction. A reduced number of joists to connect to the structural frame / walls with their associated fewer rows of bridging speeds up joist installation. If spray applied fireproofing is utilized, fewer joists result in reduced fire protection costs. Floors with wider joist spacings tend to have increased concrete slab thicknesses. Increased floor mass tends to reduce floor vibrations. Routing of electrical conduits and piping is facilitated with joists at wider spacings.

Figure 1 Narrow floor and roof joist spacings vs. Wide floor and roof joist spacings on the right Extended Joist Girder Series The current SJI Design Guide Weight Table for Joist Girders indicates joist girder weights for joist girders spanning from 20 to 60 feet supporting concentrated loads from 4 to 20 kips. For the case of joist girders supporting floor joists or beams the concentrated loads many times exceed 20 kips. Looking at our above described floor joist spanning 40 feet and supporting 1,723 plf an interior joist girder would be required to support concentrated loads of 68.92 kips on 10 foot centers. These concentrated loads greatly exceed the 20 kip maximum shown in the SJI weight tables requiring the engineer to specify a Special joist girder. To provide greater information for the Engineer, the SJI is potentially looking to extend the joist girder tables as shown below: Spans: 20 feet 130 feet Joist Girder Depth: 16 120 inches Concentrated Loads: 4 100 kips Approximate joist spacings: 4, 5, 6, 8, 10, 12, and 15 feet Maximum chord angle: L-6 x 6 x 0.625 or L 6 x 6 x 0.750 The previous maximum chord angle which the current joist girder tables are based on was a L- 5 inch x 5 inch x 0.500 inch with a cross sectional area of 4.75 square inches. The SJI Engineering Practice Committee is currently studying whether the maximum chord angle will be L-6 x 6 x 0.625 or L- 6 x 6 x 0.750. If the decision is made to utilize a maximum chord angle size of L- 6 inch x 6 inch x 0.750 inch angle having a cross sectional area of 8.438 square inches, one can expect the new weight table to increase the load carrying capacity by a factor of approximately 1.78 (8.438 / 4.75). Currently the majority of joist manufacturers can furnish joist girders with L 6 inch x 6 inch x 0.750 inch chord angles with several manufacturers furnishing chord angles up to L 8.0 inch x 8.0 inch x 1.125 inch.

UPDATE ON WORK COMPLETED BY THE SJI COMPOSITE JOIST COMMITTEE The SJI Composite Joist Committee is nearing completion of a standard specifications for the design of composite joists by all SJI member companies. This specification currently written in a LRFD format will likely be revised to a UNIFIED format covering both LRFD and ASD consistent with the 2005 AISC Standard Specification for Structural Steel Buildings. The new SJI composite joist specification will define ASTM standards for the steel utilized in the manufacture of the composite joist chords and web sections, ASTM standards for the welded shear studs, acceptable welding electrodes, nominal stresses in the chords and webs, maximum slenderness ratios, and equations for calculating stresses in the chords, webs, and concrete slab under the design loading. Equations for determining the capacity of shear studs welded to top chord angles where the ratio, d stud / top chord angle thickness 3.0 are shown. Specifications for determining the required number of rows of either horizontal or diagonal bridging are outlined. Required minimum end anchorage for each end of a composite joist based on whether the joist is sitting on masonry, concrete, or steel are indicated. To assure that the composite joists are safely erected, a section on erection stability and handling provides guidance on the minimum number of rows of bridging required before releasing the hoisting cables. Welded shear studs are commonly utilized to develop composite action between the concrete slab and steel composite joist top chord. Suggested placement details for welded shear studs on double angle joist top chords are discussed. To supplement the Specifications, the Composite Joist Committee is preparing a Recommended Code of Standard Practice for Composite Steel Joists. The Code of Standard Practice helps to define the various roles and responsibilities of the building owner, specifying design professionals, joist manufacturer, and contractors. When field load testing is required, suggested loading procedures to be followed are suggested. Items not normally included in the estimate but which may be quoted and identified as separate items include headers, erection bolts, slab reinforcement, shear studs and / or ferrules, horizontal trusses, and moment plates. When composite steel joists are subjected to concentrated loads, suggested methods for showing supported loads are presented. Information required to be shown on the Plans and Specifications is listed. Composite joist load tables are being developed following the design procedures outlined in the SJI Composite Joist Specifications. The composite joist load tables will indicate for a given composite joist span, joist depth, and uniform loading the following items: Composite Joist weight (pounds per lineal foot) Uniform composite live load that will produce a deflection of L/360 (pounds per lineal foot) Size and quantity of welded shear studs per joist Noncomposite moment of inertia (in 4 ) Rows of bridging required Joist seat depth Composite joist spans will vary from 20 feet to 120 feet with total factored uniform loads from 300 4500 plf. The SJI Composite Joist Load Tables will provide the design professional with a tool for estimating composite joist costs for Typical floors. To supplement the Load Tables, a SJI Composite Joist Design Parameters Checklist has been developed that can be completed and sent to the joist manufacturer indicating specific joist geometry, concrete depth, deck height, design loads, and deflection requirements. Given this information the joist manufacturer can prepare an exact design and cost estimate.

COMPOSITE vs. NONCOMPOSITE JOISTS When decreased floor to floor height becomes very important, composite joists can support the same uniform load utilizing a shallower steel joist depth. With the concrete slab locked to the underlying steel joist, the compression from the composite loading is transferred from the joist top chord up into the concrete. This transfer of load into the concrete allows the joist top chord size to be significantly reduced along with a reduction in joist bottom chord size. Composite joists have composite moments of inertia that are in the range of three five times stiffer than noncomposite joists with the same size chord angles. Therefore when designing shallow floors where deflection controls the design, increased economy can be achieved with composite joists. When welded shear studs are utilized to develop composite action in a steel joist, one must have a large enough floor project to justify the mobilization of the stud welding equipment. The savings in steel weight for the composite vs. noncomposite joists must be larger than the associated cost for furnishing and installing the shear connection. Noncomposite and composite steel joists are ideally suited for use in commercial applications where large column free areas are desired. Simplified erection and connections due to standard end bearing seats result in faster construction. SJI Member companies can easily customize and optimize each joist design for the particular loading and serviceability requirements. CONCLUSIONS The Steel Joist Institute is actively involved with the development of new noncomposite LH series load tables, composite joist load tables, and expanded joist girder load tables Tailored specifically toward floor applications. When completed, these design tools will facilitate the potential increased usage of steel joists in building floor applications. Steel joist construction provides the building owner with numerous advantages including a reduced building weight and associated reduced foundation cost, a reduced construction time period, very economical cost per square foot of floor area, and an environmentally friendly material that is easily recycled.